SIMATIC RTLS Localization systems SIMATIC RTLS4030G Device manual 10/2018 C79000-G8976-C515-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Agilion products Note the following: WARNING Agilion products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Agilion. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. SIMATIC RTLS4030G 2 Device manual, 10/2018, C79000-G8976-C515-01 Agilion GmbH Blankenauer Strae 74 09113 Chemnitz Germany Tel.: +49 - (0)371 - 45 00 48-0 Fax.: +49 - (0)371 - 45 00 48-11 www.agilion.de service@agilion.de Management: Andreas Werner Johannes Waldhor Sven Sieber HR B 21249 Chemnitz USt.-IdNr.: DE236591552 SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 3 Table of contents English 1 Overview ................................................................................................................................................. 6 1.1 General ...................................................................................................................................................... 6 1.2 Delivery contents ....................................................................................................................................... 6 1.3 Power supply ............................................................................................................................................. 6 1.4 Application field ......................................................................................................................................... 6 2 Layout and connections ........................................................................................................................... 7 2.1 Dimensions ................................................................................................................................................ 7 2.2 Connections and displays ......................................................................................................................... 7 2.2.1 Possible states of the LEDs ...................................................................................................................... 8 2.3 Pin allocation ............................................................................................................................................. 9 2.3.1 Power, digital output - plug-in connector .................................................................................................. 9 2.3.2 Ethernet socket RJ45 ................................................................................................................................ 9 2.3.2.1 Connection socket Amphenol LTW RCP-5SPFFH-TCU7001 .................................................................. 9 3 Installation, initial start-up, safety ........................................................................................................... 10 3.1 General information ................................................................................................................................. 10 3.2 Installation ............................................................................................................................................... 10 3.3 Connecting the cables ............................................................................................................................. 10 3.3.1 Power supply ........................................................................................................................................... 11 3.3.2 Ethernet ................................................................................................................................................... 11 3.4 Operation ................................................................................................................................................. 11 3.5 Cleaning and maintenance...................................................................................................................... 11 4 Troubleshooting ..................................................................................................................................... 12 4.1 5 General errors ......................................................................................................................................... 12 Technical data ....................................................................................................................................... 12 5.1 Connectors and power supply ................................................................................................................. 12 5.2 Ethernet ................................................................................................................................................... 12 5.3 Radio ....................................................................................................................................................... 13 5.4 Environment ............................................................................................................................................ 13 SIMATIC RTLS4030G 4 Device manual, 10/2018, C79000-G8976-C515-01 6 Approvals .............................................................................................................................................. 14 6.1 EU declaration of conformity ................................................................................................................... 14 6.2 RoHS ....................................................................................................................................................... 14 6.3 RED ......................................................................................................................................................... 15 6.3.1 Protection of health and safety ............................................................................................................... 15 6.4 Recycling and disposal ............................................................................................................................ 16 SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 5 1 Overview 1.1 General The gateway SIMATIC RTLS4030G represents, like the SIMATIC RTLS4030A, a basing point for the localization within the Wireless Location System (WLS). The gateway can be connected to the local IT-infrastructure via Ethernet. Through this connection the nodes (anchors and gateways) will exchange the localization data gathered as well as customer specific data between the localization network and the localization server. It is suggested to deploy several gateways for larger localization networks in order to raise the number of locatable transponders and to enhance the availability of the position information. 1.2 Delivery contents 1 SIMATIC RTLS4030G (article number 6GT2701-5DB03) Accessories (not included in scope of delivery) * 1 power cable (Bulgin 400 Series Buccaneer(R) PX0410/03S), 3-pin, 5 m (article number 6GT2791-2AH50) * Bayonet connector (Amphenol RCP-00BMMS-TLM7001) made of plastic for RJ45 connector for cable mounting (IP65) at gateway (article number 6GT2790-0CB00) * Holder for ceiling suspension of anchor/gateway (article number 6GT2790-0BE20) * Holder for corner/mast mounting of anchor/gateway (article number 6GT2790-0BE30) 1.3 Power supply The device can be operated with 8 to 30 V direct current (DC) voltage. CAUTION The power supply for the device should not exceed the following values: U < 30 V; I < 3.3A; P < 100 W The device can be supplied via power connector or Ethernet (PoE), not both at the same time. The device is a class 0 PoE-Device. 1.4 Application field The device has been designed for operation in humid environments. For that reason it is absolutely necessary that all connections are made using waterproof plugs according to the technical specifications described below and to prevent the ingression of moisture into the device by using the appropriate sealing caps. SIMATIC RTLS4030G 6 Device manual, 10/2018, C79000-G8976-C515-01 2 Layout and connections 2.1 Dimensions Power Radio Network Power Venting Ethernet 2.2 Connections and displays Connection Description Power Electricity supply Ethernet RJ45 Ethernet with PoE, Amphenol LTW RCP-00AMMA-TLM7001 Display Description Power LED (green/red) LED signaling electricity supply Radio LED (yellow) Network LED (blue) LED signaling the activity of the WLS (sending and receiving radio signals) LED signaling connection to the local IT-network SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 7 2.2.1 Possible states of the LEDs Power LED status display (green/red) Description On (green) Power supply via cord Flashes red every second Undervoltage Radio LED status display (yellow) Description Off Device's WLS radio disabled Flashes Device's WLS radio active Network LED status display (blue) Description On Network connection established via LAN (Ethernet) Flashes every second Off Network connection established but no connection to the WLS server No network connection established SIMATIC RTLS4030G 8 Device manual, 10/2018, C79000-G8976-C515-01 2.3 Pin allocation 2.3.1 Power, digital output - plug-in connector GND Power 3-pole connector Buccaneer(R) PX0412/03P Pins: SA3350/1 Sealing cap: PX0480 Digital output Pin Description 1 - Power (red) 8 ... 30 V DC 2 - GND (black) GND (0 V) 3 - Digital output (brown) Switched input voltage, maximum current (I) 200 mA 2.3.2 Ethernet socket RJ45 The device may only be connected to the Ethernet using the connectors depicted below. Make sure the twist-lock plugs are locked accurately when connecting the Ethernet cable. 2.3.2.1 Connection socket Amphenol LTW RCP-5SPFFH-TCU7001 Matching plug: RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 9 3 Installation, initial start-up, safety 3.1 General information * The devices can only be used in combination with the WLS. * Buildup, installation as well as the use of the tools and clients of the localization system are described in the corresponding guides and manuals. 3.2 Installation * Carefully read all items listed in section 3 (Installation, initial start-up, safety) before installing the devices in order to safeguard correct installation and operation. * The device is destined for fixed installation onto walls or ceilings. * The installation has to be carried out by appropriately qualified and trained personnel and according to the installation guide. * Follow the references concerning the surrounding conditions when installing and operating the devices. * Make sure that all screws are screwed tightly to the wall/ceiling and that they are able to carry the weight of device and wiring. * The ambient temperature must not exceed 50 C. Avoid installing devices at locations exposed to direct sunlight. * The installation of the devices has to be carried out according to the applicable provisions for the installation of electrical systems and utilities. The devices have to be fitted accessible (to open the housing cover) for later maintenance. 3.3 Connecting the cables * Make sure the twist-lock plugs are locked into place correctly to prevent the ingression of moisture. * Make sure that any wiring has been carried out correctly before the start-up of the device. * Use solely wiring as described in the manual, enclosed with the device or specified accordingly. Agilion GmbH is not liable for any damages or impairment of functionality resulting from the use of other cables. Note Insofar as any connectors are not in use, they have to be sealed with the appropriate caps. The caps are attached to the device. SIMATIC RTLS4030G 10 Device manual, 10/2018, C79000-G8976-C515-01 3.3.1 Power supply * When connecting the power supply to the power connector, all LEDs flash for an instant. The power LED is on, if power is supplied (cf. states of the LEDs 2.2.1). * The device can be powered via Ethernet cable. In this case the power supply connector should be sealed to avoid ingress of moisture. * Do not supply the device by power input and PoE at the same time. * Check whether the nominal voltage of the power supply is in accordance with the values stated in section "Technical data" (cf. 5). CAUTION The power supply for the device should not exceed the following values: U < 30 V; I < 3.3A; P < 100 W 3.3.2 Ethernet * Mind the relevant general conditions and their legal basis when installing and connecting the Ethernet line. * Connect the Ethernet cable to the appropriate socket. Assemble the Ethernet cable into the RJ45 jack beforehand. * To supply the device Power over Ethernet (PoE) an appropriate infrastructure such as PoEIniector or PoE-Switch is necessary. 3.4 Operation * The device is not designed for use in EX-zones. * Operation of the system in accordance with regulation EN 60950-1 is only safeguarded insofar as the case-cover is mounted (cooling, fire protection, disturbance suppression). * Break the circuit connecting the device in case of emergencies (e.g. damaged housing, intrusion of liquids or foreign objects) and notify the service immediately. 3.5 Cleaning and maintenance * The device may only be opened by appropriately trained and qualified personnel. * Repairs may exclusively be carried out by authorized service points. * Unauthorized opening and improper repairs of the device can cause substantial dangers for the user. * Agilion GmbH's warranty and liability are void in case of unauthorized opening of the device. * Never use abrasive, alkaline or aggressive cleaning agents or auxiliary devices when cleaning the housing. SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 11 4 Troubleshooting 4.1 General errors Fault detection Cause of error Troubleshooting Wireless module does not Module is not connected or power Check module's power supply react, all LEDs are off supply is not switched on. Power LED (red) flashes Undervoltage Check power supply Radio LED (yellow) is off No connection to the WLS Activate localization network Network LED (blue) is off No network connection established Check local IT network, check (LAN) firewall every second 5 Technical data 5.1 Connectors and power supply Connectors and power supply Voltage 8 ... 30 V DC, nominal 24 V DC Power consumption 9W Power connector 3-pole plug-in connector with screw terminal Bulgin Buccaneer(R) PX0412/03P Ethernet RJ45 Ethernet via connector socket Amphenol LTW RCP-5SPFFHTCU7001 Matching plug: Amphenol LTW PCP-00AMMA-TLM7001 5.2 Ethernet Ethernet Ethernet 10/100MBit auto-detect Duplex mode Half- or full-duplex DHCP Yes PoE IEEE 802.3af class 0, power level 0.44 ... 12.94 W SIMATIC RTLS4030G 12 Device manual, 10/2018, C79000-G8976-C515-01 5.3 Radio Radio - PULSE Wireless technology IEEE 802.15.4-2011 UWB Operating frequency 3100 MHz ... 4800 MHz 6000 MHz ...7000 MHz Output power 0.037 mW (-41.3 dBm/MHz) Antennas UWB-Antenna Built-in Radio - PHASE Wireless technology IEEE 802.15.4 Operating frequency 2.40 ... 2.48 GHz ISM-Band Bandwidth 2 MHz; Data transmission at 802.15.4 , channels selectable Output power 100 mW Antennas 2.4 GHz Antenna Built-in 5.4 Environment Environment and dimensions Case Plastic housing (ASA+PC), IP65, UV-resistant Installation Fixed installation onto walls or ceilings Dimension 180 x 180 x 48 mm Weight Approx. 650 g Temperature range -15 ... +50 C SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 13 6 Approvals 6.1 EU declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Agilion GmbH Blankenauer Strae 74 09113 Chemnitz Bundesrepublik Deutschland You can find the current EU declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/cert) The products described in this document meet the requirements of the following EC directives: * RoHS directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 01/07/2011, pages 88-110 * Radio equipment directive 2014/53/EU (RED, Radio Equipment Directive) Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment; official journal of the EU L153, 22/05/2014, pages 62-106 6.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU for the restriction of the use of certain hazardous substances in electrical and electronic equipment. Applied standard: * EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances SIMATIC RTLS4030G 14 Device manual, 10/2018, C79000-G8976-C515-01 6.3 RED 6.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) protection of health and safety * EN 62368-1 Information technology equipment - Safety - Part 1: General requirements * EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. Art. 3 (1) b) EMC: * ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements * ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for Broadband Data Transmission Systems * ETSI EN 301 489-33 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 33: Specific conditions for Ultra-WideBand (UWB) devices * EN 50121-3-2 Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus * EN 55011 Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics Limits and methods of measurement * EN 55032 Class A, Class B Electromagnetic compatibility of multimedia equipment - Emission requirements * EN 55035 Electromagnetic compatibility of multimedia equipment - Immunity requirements * EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 15 * EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments * EN 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments * EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments Art. 3 (2) Efficient use of the radio spectrum * ETSI EN 300 328 Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU * ETSI EN 302 065-2 Short Range Devices (SRD) using Ultra Wide Band technology (UWB); Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: Requirements for UWB location tracking Note The specified approvals apply only when the corresponding mark is printed on the device. 6.4 Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations. SIMATIC RTLS4030G 16 Device manual, 10/2018, C79000-G8976-C515-01 Important information for use in the USA: * This equipment may only be operated indoors. Operation outdoors is in violation of 47 U.S.C. 301 and could subject the operator to serious legal penalties. * This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. * This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. * Changes modifications or made to this equipment not expressly approved by Agilion GmbH may void the FCC authorization to operate this equipment. * This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 17 Appendix 1 - Quick installation guide 3x 1x 1x 1x 3x 130 3x 142 1 3x 4 130 2 5mm 3 142 5 7 6 not included in Anchor black = GND red = Power brown = digital out 20170315-Drilling template MESH SIMATIC RTLS4030G 18 Device manual, 10/2018, C79000-G8976-C515-01 Drilling template on a scale of 1:1 All dimensions in millimeters SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01 19