H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTIPLE OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP101 SERIES FEATURES: ACCOMMODATE UNIVERSAL AC SOURCES PCB VERSION FORMAT MEET IEC1000-3-2 HARMONIC CORRECTION MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB. 22 & FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M connector & GND tag. Input Frequency: 47-63Hz. Inrush Current: Typ. 29A@230Vac. Input Current: Typ. 1.3A @115Vac, 0.65A @230Vac. Dielectric Withstand: Meet IEC950. EMI: Meet CISPR EN55022 B & FCC Class B. Hold-up Time: Typ. 18-25mS @ 115Vac & 230Vac. Power Factor & Harmonic Correction: Meet IEC1000-3-2, PF typ. 0.97-0.99 @ full load. Power OK: Installed in VO1 & VO2. Over Temperature Protection (OTP): By NTC at quad output only. Earth Leakage: Less than 0.75mA @230Vac. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: V-M connector. Output Wattage: Typ. 100 Watts. Line Regulation: Typ. 0.1%. Load Regulation: Main VO1 typ. 1-2%. Aux. VO2 typ. 1-2% (Magnetic Amp.). Aux. VO3 typ. 1-2% (Magnetic Amp.). Aux. VO4 typ. 2-3% (P.R.). Noise & Ripple: Typ. 1% peak to peak. OVP: Built-in at main VO1 & Aux.VO2 & VO3 (latch). Remote Sensing: Available at VO1 & VO2. Adjustability: Available at VO1,VO2 & VO3. Over Current Protection: Built-in at all output. Overload Protection (OLP): Fully protected against output overload and short circuit at any output. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 75-80%. Switching Frequency: PFC ckt. 75K Hz. PWM ckt. 170-180K Hz. Circuit Topology: Fixed frequency forward circuit. Transient Response: Output voltage returns in less than 0.3mS following a 25% load change. Safety Standard: IEC950/UL1950 Class I. Operating Temperature: 0 to +50C under forced air flow for full load. Storage Temperature: -20 to +85C. Temperature Coefficient: 0.04% /C. Cooling: At least 30 cfm direct forward air flow is required to achieve full rating power. Construction: PCB format. Power Density: 5.6 Watts / Cubic Inch. -49- In application OUTPUT VOLTAGE / CURRENT RATINGS CHART DUAL OUTPUT (Under forced air flow) SINGLE OUTPUT (Under forced air flow) MODEL NO. HVP101-S033200 HVP101-S050160 HVP101-S120085 HVP101-S150068 HVP101-S240042 HVP101-S280036 HVP101-S360028 HVP101-S480021 MAIN VO1 @# Typ. Peak Volt. 20.0A 3.3V 25.0A 16.0A 5.0V 20.0A 8.5A 12.0V 9.0A 6.8A 15.0V 7.0A 4.2A 24.0V 6.0A 3.6A 28.0V 5.0A 2.8A 36.0V 4.0A 2.1A 48.0V 3.0A MODEL NO. HVP101-D050E HVP101-D050I HVP101-D050K HVP101-D050D HVP101-D033I HVP101-D033K MAIN VO1 Typ. 12.0A 12.0A 12.0A 12.0A 15.0A 15.0A AUX. VO2 # Typ. Volt. 6.0A +5.0V 4.0A +12.0V 3.0A +15.0V 8.0A +3.3V 4.0A +12.0V 3.0A +15.0V @# Volt. +5.0V +5.0V +5.0V +5.0V +3.3V +3.3V QUAD OUTPUT (Under forced air flow) MODEL NO. HVP101-Q050DII HVP101-Q050DIE HVP101-Q050MII HVP101-Q050KIE HVP101-Q050KII MAIN VO1 @# Typ. Volt 12.0A +5.0V 12.0A +5.0V 10.0A +5.0V 10.0A +5.0V 8.0A +5.0V AUX. VO2 Typ. 6.0A 7.0A 1.5A 2.5A 2.5A @# Volt + 3.3V + 3.3V +24.0V +15.0V +15.0V AUX. VO3 Typ. 1.5A 1.5A 1.5A 1.5A 2.0A AUX. VO4 Typ. Volt 0.5A -12V 0.5A - 5V 0.2A -12V 0.4A - 5V 0.2A -12V @ Volt +12V +12V +12V +12V +12V Symbol: "" OVP built-in. "@" Adjustable. "#" Remote sense. "" Installed with Post Regulator. "" Installed with magnetic amplifier. Remark: Peak output, less than 60 Sec. with 10% duty cycle. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 368.0g(12.97 Oz.) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS AC INPUT ASSIGNMENT CONNECTOR & PIN # L N P1-3 P1-1 SINGLE OUTPUT GND VO1 Tab P2-6,7,8, 9,10,11 DC COM P2-1,2, 3,4,5 DUAL OUTPUT +VO1# P.OK VO1 VO2 P2-13 P2-14 P2-9, 10,11 P2-6, 7,8 DC DC +VO1 # +VO2 # P.OK VO1 VO2 COM COM P2-1,2, P2-1,2, P2-5,6 P2-13 P2-12 P2-14 P2-9,10 3,4 3,4 7,8 Mating connector: Molex 5195 or 5239 series. -50- QUAD OUTPUT VO3 VO4 P2-11 P2-12 VO1+ # VO2+ # P3-3 P3-4 VO1,2- # P. OK P3-1 P3-2