TL-TTL-T
2
Specifications
JRATINGS/CHARACTERISTICS
Part number TL-T2E1, TL-T2E2,
TL-T2F1, TL-T2F2
TL-T2Y1, TL-T2Y2 TL-T5ME1, TL-T5ME2,
TL-T5MF1, TL-T5MF2
TL-T5MY1, TL-T5MY2
Supply voltage (operating voltage range) E and F models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max.
Y models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption E and F models: 15 mA max. at 24 VDC
Leakage current Y models: 2.5 mA max. at 200 VAC
Sensing object Magnetic metal (The sensing distance decreases with non-magnetic metal.)
Sensing distance 2mm±10% (0.08 ±10%) 5mm±10% (0.19 ±10%)
Sensing distance (standard object) 0 to 1.6 mm (iron, 12 x 12 x 1 mm)
0 to 0.06 in (iron 0.47, 47 x 0.04 in)
0to4mm(iron,15x15x1mm)
0to0.157in(iron0.59x0.59x0.39in)
Differential travel 10% max. of sensing distance
Response frequency E and F models: 800 Hz,
Y models: 20 Hz
E and F models: 250 Hz,
Y models: 20 Hz
Operating status (with sensing object
approaching)
E1 models: L output signal with load ON
E2 models: H output signal with load OFF
F1 models: H output signal with load ON
Y1 models: Load ON
Y2 models: Load OFF
Control output Type E1: NPN-NO Y1: SCR-NO
E2: NPN-NC Y2: SCR-NC
F1: PNP-NO
F2: PNP-NC
Switching
capacity
E and F models: 100 mA max. at 12 VDC and 200 mA max. at 24 VDC
Y models: 10 to 200 mA
Circuit protection E and F models: Reverse connection protection and surge absorber
Y models: Surge absorber
Indicator Operation indicator (red LED)
Ambient temperature Operating -- 2 5 °Cto70°C(--13°F to 158°F)withnoicing
Ambient humidity Operating 35% to 95%
Temperature influence ±10% max. of sensing distance at 23°C (73.4°F) in the temperature range of
-- 2 5 °Cto70°C(--13°F to 158°F)
Voltage influence E and F models: ±2.5% max. of sensing distance within a range of ±15% of the rated power
supply voltage
Y models: ±2.5% max. of sensing distance within a range of ±10% of the rated power supply
voltage
Residual voltage E and F models: 1.0 V max. with a load current of 100 mA and a cord length of 2 m
Y models: Refer to Residual Load Voltage (Typical) on page 4.
Insulation resistance 50 MΩmin. (at 500 VDC) between case and current carry parts
Dielectric strength DC switching models: 1,000 VAC, 50/60 Hz for 1 min between case and current carry
parts
AC switching models: 2,000 VAC, 50/60 Hz for 1 min between case and current carry
parts
Vibration resistance 10 to 55 Hz, 1.5-mm (0.06 in)double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 500 m/s2(1640 ft/s2) approx. 50G for 10 times each in X, Y, and Z directions
Enclosure rating IEC IP67
Weight (with 2-m cord) Approx. 70 g (2.47 oz)
Material Case Heat-resistant ABS resin
Sensing
surface
Heat-resistant ABS resin