CV-N (ACVN)
–2– ASCTB297E 201709-T
RATING
1. Coil data
2. Specifications
Notes: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
*2. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. For details, please refer to the
“Automotive Relay Users Guide”.
*4. Please inquire our sales representative if you will be using the relay in a high temperature atmosphere.
Rated coil
voltage
Operate (Set) voltage
(at 20°C 68°F) (Initial)
Release (Reset)
voltage
(at 20°C 68°F) (Initial)
Rated operating current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Rated operating power
(at 20°C 68°F)Usable voltage range
12V DC Max. 7.0 V DC Min. 0.5 V DC
66.7 mA,
74.7 mA (with resistor
inside)
180Ω,
160.7Ω (with resistor
inside)
800 mW,
900 mW (with resistor
inside)
10 to 16V DC
Item Specifications
Contact data
Contact arrangement 1 Form A
Contact resistance (initial) Max. 15mΩ (Typ. 3mΩ) (By voltage drop 1A 6V DC)
Contact material Ag alloy
Rated switching capacity
(resistive) N.O. side: 35 A 14V DC
Max. carrying current*1N.O. side: 20 A 14V DC (at 85°C 185°F, continuous)
Min. switching load
(resistive)*21 A 14V DC (at 20°C 68°F)
Contact voltage drop (initial) N.O. side: Max. 0.5 V (By voltage drop 14 V DC 35 A)
Insulated resistance (initial) Min. 20 MΩ (at 500V DC, Measurement at same location as “Dielectric strength” section.)
Dielectric
strength (initial)
Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
Time
characteristics
(initial)
Operate (Set) time
(at rated coil voltage) Max. 10ms (at 20°C 68°F, without contact bounce time)
Release (Reset) time
(at rated coil voltage) Max. 10ms (at 20°C 68°F, without contact bounce time) (Without diode)
Shock
resistance
Functional Min. 100 m/s2 {approx. 10G} (Half-wave pulse of sine wave: 11ms; detection time: 10μs)
Destructive Min. 1,000 m/s2 {approx. 100G} (Half-wave pulse of sine wave: 6ms)
Vibration
resistance
Functional 10 to 100 Hz, Min. 44.1 m/s2 {approx. 4.5G} (Detection time: 10μs)
Destructive 10 to 500 Hz, Min. 44.1 m/s2 {approx. 4.5G}, Time of vibration for each direction; X, Y, Z direction: 4 hours
Expected life
Mechanical Min. 106 (at 120 cpm)
Electrical
<Resistive load>
Min. 105 at rated switching capacity, operating frequency: 2s ON, 2s OFF
<Motor load>
Min. 3 × 105 at inrush 84 A, steady 18 A, 14 V DC, Operating frequency: 2s ON, 5s OFF
<Lamp load>
Min. 2 × 105 at inrush 84 A, steady 12 A, 14 V DC, Operating frequency: 1s ON, 14s OFF
Conditions Conditions for usage,
transport and storage*3Ambient temperature: –40 to +85°C –40 to +185°F*4, Humidity: 5 to 85% R.H. (Please avoid icing or condensation)
Weight Approx. 12 g .42 oz