55M1421 Issue 3 7th September 2009 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only TWO CONDUCTOR CABLE, MODIFIED FLUOROPOLYMER INSULATED, SHIELDED AND JACKETED, 450 VOLT, 150C, LIGHTWEIGHT The complete requirements for procuring the wire described herein shall consist of this document. Shield Tin Coated Copper Coverage 85% minimum Component wire 55M0411 Jacket Radiation Crosslinked Modified ETFE C7 Part Description C8 Wire Size 55M1421-30-*/*-* 55M1421-28-*/*-* 55M1421-26-*/*-* 55M1421-24-*/*-* 55M1421-22-*/*-* 55M1421-20-*/*-* 30 28 26 24 22 20 C9 C10 C11 C12 C13 C14 Shield Jacket Thickness Overall Diameter Maximum Size (mm) (mm) Weight (mm) (kg/km) Min. Nom. Nom. Max.. 0.08 0.10 0.15 1.67 1.79 5.58 0.08 0.10 0.15 1.83 1.95 6.85 0.08 0.10 0.15 2.03 2.17 8.80 0.08 0.10 0.15 2.28 2.44 11.40 0.10 0.15 0.20 2.74 2.92 16.59 0.10 0.15 0.20 3.20 3.41 23.60 COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code designator in accordance with IEC 60304. e.g. 55M1421-24-2/6-9, core red/ blue, jacket white Unless otherwise specified by the purchaser component colours to be: red, blue with white jacket. PERFORMANCE REQUIREMENTS: To be tested to and meet the requirements of the issue in effect of Raychem Specification WCD 32/1 and Raychem Specification 55A as applicable. ADDITIONAL REQUIREMENTS: Jacket APPROVAL: Electronic sign off - no signature will appear. Elongation - 50% minimum Tensile Strength - 35 N/ mm minmum Accelerated Ageing - 2.5 kV wet dielectric test (c)2009 Tyco Electronics Corporation. All International Rights Reserved.