Specification Control Drawing
TWO CONDUCTOR CABLE, MODIFIED FLUOROPOLYMER INSULATED, SHIELDED AND JACKETED,
450 VOLT, 150°C, LIGHTWEIGHT
Tin Coated Copper
Coverage 85% minimum
55M0411 Radiation Crosslinked
Modified ETFE
Wire Shield Jacket Thickness Overall Diameter Maximum
Size Size (mm) (mm) Weight
(mm) Min. Nom. Nom. Max.. (kg/km)
30 0.08 0.10 0.15 1.67 1.79 5.58
28 0.08 0.10 0.15 1.83 1.95 6.85
26 0.08 0.10 0.15 2.03 2.17 8.80
24 0.08 0.10 0.15 2.28 2.44 11.40
22 0.10 0.15 0.20 2.74 2.92 16.59
20 0.10 0.15 0.20 3.20 3.41 23.60
COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code
designator in accordance with IEC 60304.
e.g. 55M1421-24-2/6-9, core red/ blue, jacket white
Unless otherwise specified by the purchaser component colours
to be: red, blue with white jacket.
PERFORMANCE To be tested to and meet the requirements of the issue in effect of
REQUIREMENTS: Raychem Specification WCD 32/1 and Raychem Specification 55A as applicable.
ADDITIONAL Jacket Elongation - 50% minimum
REQUIREMENTS: Tensile Strength - 35 N/ mm² minmum
Accelerated Ageing - 2.5 kV wet dielectric test
APPROVAL: Electronic sign off - no signature will appear.
©2009 Tyco Electronics Corporation. All International Rights Reserved.
C7
Page 1 of 2
Page 2 is for internal use only
Issue 3
7th September 2009
The complete requirements for procuring the wire described herein shall consist of this document.
Part
Description
55M1421-22-*/*-*
55M1421-20-*/*-*
55M1421-30-*/*-*
55M1421-28-*/*-*
55M1421-26-*/*-*
55M1421-24-*/*-*