B43858 High Ripple Capability Specifications and characteristics in brief Rated voltage Surge voltage Rated capacitance Capacitance tolerance Useful life 40 C, U R 105 C, U R ; Iacmax Failure rate UR US CR C/C Voltage endurance test 160 ... 450 1.1 . UR 2.2 ... 330 20 (M) Vdc > 400 000 (1.6 . Iacmax, 105C) > 5 000 100 fit -9 ( 100 . 10 /h) 5000, 105C (at U R) h F % h Evaluation criteria: 25 % of initial measured value C/C Tan 2 times initial specified value IL initial specified value 40/105/56 - UR 250V Climatic category in accordance with IEC 60068 Standards 25/105/56 - UR IEC 60384 - 4 Vibration resistance 350V in accordance with IEC 68068 - 2, test Fc: Displacement amplitude 0.75 mm, frequency range 10 ... 2000 Hz, acceleration max. 10g, duration 3 x 2 h B43888 High Ripple Capability and Long Life Specifications and characteristics in brief Rated voltage Surge voltage Rated capacitance Capacitance tolerance Useful life 105C, UR; Iacmax 105C, U; Iac Failure rate Voltage endurance test Climatic category in accordance with IEC 60068 Standards Vibration resistance 10 UR US CR C/C 160 ... 450 1.1 . UR 6.8 ... 100 20 (M) Vdc 8 0 00 for d = 10mm 10 000 for 12,5 mm 100 fit -9 ( 1 fit = 10 /h) 8 000, 105C for d = 10mm at UR 10 000, 105C for d = 12.5mm at UR h F % h Evaluation criteria: 25 % of initial measured value C/C Tan 2 times initial specified value IL initial specified value 40/105/56 - UR 250V 25/105/56 - UR IEC 60384-4 350V in accordance with IEC 68068 -2, test Fc: Displacement amplitude 0.75 mm, frequency range 10 ... 2000 Hz, acceleration max. 10 g, duration 3 x 2 h EPCOS do Brasil Ltda.