1
HAS SERIES - 30 WATT
REV. 12/01
• Industry Standard
Half-Brick
• Low-Cost Design
• 100°C Baseplate
Operation
• Open-Frame Packaging
• 24V and 48V Input
Versions
• Input Pi Filter
• Optional Enable Logic
• 1500V Isolation
FEATURES
HAS DC/DC converters provide up to 30 watts of
output power in an industry-standard package and
footprint. With a maximum case temperature of
100°C, the HAS is well suited for the most
demanding telecom, networking, and industrial
applications. The HAS features 1500 VDC isolation,
short circuit, and overtemperature protection, as well
as six-sided shielding. The HAS series is available
with optional enable and voltage trim pins. Please see
the IAD series for dual output applications.
DESCRIPTION
TECHNICAL SPECIFICATIONS
Voltage Range
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 36 - 75 VDC
Reflected Ripple 50 mA
Input
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated 0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 0.2% Vout
Remote Sense Headroom 0.5 VDC
Minimum Output Current 10 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 µs
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Hiccup
Current Limit Threshold Range, % of Iout Rated 110 - 140%
OVP Trip Range 115 - 140% Vout Nom.
Remote Shutdown Reference Vin Negative
Shutdown Pin Current, Sourced At Off 10 mA Max.
Output
General
Turn-On Time 10 mS
Remote Shutdown Positive/Negative Logic
Switching Frequency 250 kHz
Isolation
Input - Output 1500 VDC
Input - Case 1050 VDC
Output - Case 500 VDC
Temperature Coefficient 0.03%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF(Bellcore TR-NWT-000332) 2.5 X 106hrs
Safety UL, cUL, TUV
Weight (Approx.) 1.4 oz
50
55
60
65
70
75
80
85
90
95
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
HAS030ZH-A
HAS030ZG-A
HAS030ZJ-A
HAS030YG-A
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
EFF. (18v)
EFF. (24v)
EFF. (36v)
Efficiency vs. Load (48V Input)
Efficiency vs. Load (24V Input)
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
2
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
HAS030YG-A 24 18-36 2.2 5 6.0 100 83%
HAS030YH-A 24 18-36 2.2 12 2.5 150 87%
HAS030YJ-A 24 18-36 2.2 15 2.0 150 86%
HAS030ZE-AT 48 36-75 1.0 3.3 6.0 100 81%
HAS030ZG-A 48 36-75 1.3 5 6.0 100 83%
HAS030ZH-A 48 36-75 1.3 12 2.5 150 88%
HAS030ZJ-A 48 36-75 1.3 15 2.0 150 88%
NOTES:
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
HAS SERIES - 30 WATT
MODELS - (See the last page of section for options.)
MECHANICAL DRAWING










 
 




 
   !"

# $%




Thermal Impedance
Natural Convection 7.9 °C/W
100 LFM 6.8 °C/W
200 LFM 4.9 °C/W
300 LFM 3.6 °C/W
400 LFM 3.0 °C/W
Tolerances
Note:
Thermal impedance data is
dependent on many environmental
factors. The exact thermal
performance should be validated
for specific application.
1-V
in
2 Case
3 On/Off
4+V
in
5-V
out
6 -Sense
7 Trim
8 +Sense
9+V
out
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless
otherwise specified.)
Pin Function
3
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y Encapsulated EWS, IWS, OWS
Pin Length and Heatsink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Units (Except SMS)
0.150" (3.8mm) Pin Length 9 All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink 1H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink 1V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink 2V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink 3V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
OPTIONS