TWC-Y High Temperature Series COTS-Plus 200C Wet Tantalum The TWC-Y high temperature series represents a COTS-Plus version of conventional wet electrolytic tantalum capacitors that are designed for use at 200C. The majority of components listed are now capable of 500 hours of operation at extreme temperature with the applicable derated voltage. This design includes a welded tantalum can and header assembly that provides a hermetic seal to withstand harsh environments. This is a new product line so please contact the factory for availability and additional details. CASE DIMENSIONS: millimeters (inches) Standard Case Size T1 T2 T3 T4 AVX Case Size A B D E L +0.79 (0.031) -0.41 (0.016) 11.51 (0.453) 16.28 (0.641) 19.46 (0.766) 26.97 (1.062) D Basic Case 0.41 (0.016) 4.78 (0.188) 7.14 (0.281) 9.52 (0.375) 9.52 (0.375) D Insulated Case Max 5.56 (0.219) 7.92 (0.312) 10.31 (0.406) 10.31 (0.406) E 6.35 (0.250) 38.10 (1.500) 57.15 (2.250) 57.15 (2.250) 57.15 (2.250) OUTLINE DIMENSIONS E L W E F D - Terminal welded to case (T) F 6.35 (0.250) W 0.64 +0.05 (.025 +.002) T 2.380 (.094) + Case HOW TO ORDER AVX PART NUMBER: TWC B 476 * 050 C Y Z 00 00 Type Case Size Capacitance Code pF code: 1st two digits represent significant figures 3rd digit represents multiplier (number of zeros to follow) Capacitance Tolerance M = 20% K = 10% Voltage Code Insulation Sleeve C = Without Sleeve S = With Sleeve ESR C = Standard ESR Qualification Y = High Temp. Reliability Z = Non-ER Termination Finish 00 = Sn/Pb 60/40 Custom Test Options 00 = Standard Not RoHS Compliant TECHNICAL SPECIFICATIONS Technical Data: Capacitance Tolerance: Rated Voltage (VR) Category Voltage (VC) High Temp, Voltage (VT) Surge Voltage (VS) Temperature Range: 85C 125C 200C 85C Unless otherwise specified, all technical data relate 10%; 20% 6 8 10 15 25 30 4 5 7 10 15 20 3.6 4.8 6 9 12 18 6.9 9.2 11.5 17.3 28.8 34.5 -55C to +200C to an ambient temperature of +25C 50 30 30 57.5 60 40 36 69 75 50 45 86.3 100 65 60 115 OCTOBER 2013 125 85 75 144 n 95 TWC-Y High Temperature Series COTS-Plus 200C Wet Tantalum STANDARD RATINGS & PART NUMBER REFERENCE AVX Part Number Cap (F) +25C at 120Hz +TWCB147*006CYZ0000 TWCD337*006CYZ0000 TWCD567*006CYZ0000 140 330 560 +TWCB127*008CYZ0000 TWCD297*008CYZ0000 TWCD437*008CYZ0000 120 290 430 +TWCB107*010CYZ0000 TWCD257*010CYZ0000 TWCD397*010CYZ0000 100 250 390 +TWCB706*015CYZ0000 +TWCD177*015CYZ0000 TWCD277*015CYZ0000 70 170 270 TWCA686*025CYZ0000 +TWCB107*025CYZ0000 TWCD127*025CYZ0000 +TWCD187*025CYZ0000 TWCB277*025CYZ0000 68 100 120 180 270 TWCA566*030CYZ0000 +TWCB686*030CYZ0000 TWCD107*030CYZ0000 TWCD157*030CYZ0000 TWCB227*030CYZ0000 TWCE307*030CYZ0000 56 68 100 150 220 300 TWCA336*050CYZ0000 +TWCB476*050CYZ0000 TWCD606*050CYZ0000 TWCD826*050CYZ0000 TWCB127*050CYZ0000 TWCE167*050CYZ0000 33 47 60 82 120 160 TWCA276*060CYZ0000 TWCD506*060CYZ0000 TWCD686*060CYZ0000 TWCB107*060CYZ0000 TWCE147*060CYZ0000 27 50 68 100 140 TWCA226*075CYZ0000 TWCD566*075CYZ0000 TWCB826*075CYZ0000 TWCE117*075CYZ0000 22 56 82 110 +TWCB226*100CYZ0000 TWCE127*100CYZ0000 22 120 +TWCB276*125CYZ0000 TWCE826*125CYZ0000 27 82 DC Rated Voltage (V) at +85C DC Leakage (A) +85C & +125C +25C 6 VDC at 85C 1 2 2 8 VDC at 85C 8 1 8 2 8 2 10 VDC at 85C 10 1 10 2 10 2 15 VDC at 85C 15 1 15 2 15 2 25 VDC at 85C 25 2 25 1 25 2 25 2 25 3 30 VDC at 85C 30 2 30 1 30 2 30 2 30 3 30 8 50 VDC at 85C 50 2 50 1 50 2 50 2 50 4 50 8 60V VDC at 85C 60 3 60 2 60 2 60 4 60 8 75V VDC at 85C 75 3 75 2 75 4 75 9 100 VDC at 85C 100 1 100 12 125 VDC at 85C 125 5 125 12 6 6 6 Note: AVX reserves the right to supply higher voltage rating in the same case size to the same reliability standards. 96 n OCTOBER 2013 Maximum Capacitance Change (%) -55C +85C +125C 4 VDC at 125C 3.6 VDC at 200C 3 1.99 -40 7.9 1.45 -44 13 1.3 -64 5 VDC at 125C 4.8 VDC at 200C 2 2.21 -44 6 1.56 -64 14 1.42 -64 7 VDC at 125C 6 VDC at 200C 4 1.99 -36 10 1.59 -40 16 1.5 -64 10 VDC at 125C 9 VDC at 200C 4 2.46 -28 10 1.95 -32 16 1.57 -56 15 VDC at 125C 15 VDC at 200C 9 4.29 -50 10 1.99 -28 6 2.32 -32 18 1.92 -48 16 2.70 -62 20 VDC at 125C 18 VDC at 200C 9 5.21 -48 8 2.54 -24 12 2.26 -28 18 2.03 -48 16 2.53 -60 32 1.37 -60 30 VDC at 125C 30 VDC at 200C 9 4.95 -39 9 3.11 -28 12 2.65 -16 16 2.43 -32 24 2.49 -42 32 1.41 -50 40 VDC at 125C 36 VDC at 200C 12 5.01 -34 12 2.65 -16 16 2.54 -32 20 2.52 -36 32 1.52 -40 50 VDC at 125C 45 VDC at 200C 12 5.13 -29 17 2.61 -28 24 2.46 -30 36 1.45 -35 65 VDC at 125C 60 VDC at 200C 9 4.52 -16 48 2.76 -35 85 VDC at 125C 75 VDC at 200C 24 3.54 -18 48 2.82 -30 All technical data relates to an ambient temperature of +25C. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V. DCL is measured at rated voltage after 5 minutes. +Ratings currently qualified to 300 hours of operation at 200C with 60% rated voltage. ESR Max (Ohms) at 120Hz Case Size Standard AVX 14 14 17.5 16 16 20 T2 T3 T3 B D D 17.5 17.5 17.5 20 20 20 T2 T3 T3 B D D 14 14 17.5 16 16 20 T2 T3 T3 B D D 14 14 17.5 16 16 20 T2 T3 T3 B D D 12 13 13 13 13 15 15 15 15 16 T1 T2 T2 T3 T3 A B B D D 12 13 10.5 13 13 25 15 15 12 15 16 25 T1 T2 T3 T3 T2 T4 A B D D B E 10 13 10.5 13 12 25 12 15 12 15 15 25 T1 T2 T3 T3 T2 T4 A B D D B E 10 10.5 10.5 12 20 12 12 12 15 20 T1 T3 T3 T2 T4 A D D B E 10 10.5 12 20 12 15 15 20 T1 T3 T2 T4 A D B E 8 15 8 17 T2 T4 B E 12 15 15 17 T2 T4 B E 200C LIFE TEST: These components are capable of 500 hours of operation at 200C with the applicable 60% derated voltage, with the exception of those ratings indicated in the table as having only 300 hour qualifications. These ratings will be extended to 500 hour capability after completion of further testing. Following the life test components which are stabilized at 25C 5C shall exhibit: Leakage less than 200% the original requirement or 10uA (whichever is greater) ESR not greater than 200% the original requirement Capacitance increase less than 10% or decrease less than 20% the initial measurement