Bussmann(R) LOW-PEAK(R) LP-CC Time-Delay Fuses Class CC - 600 Volt, TM to 30 Amps Dimensional Data 1.5" (0.031) (38.1mm) .41" (0.005) (10.3mm) Catalog Symbol: LP-CC Time-Delay, Current-Limiting Ampere Rating: TM to 30A AC Voltage Rating: 600V (or less) Interrupting Rating: 200,000A RMS Sym. Agency Information: UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273 CSA Certified, C22.2 No. 248.4, Class 1422-02, File 53787 DC Voltage Rating: 300Vdc (or less) TM-2 /A and 20-30A, 20,000 AIR, UL 198L 150Vdc or less 3-15A, 20,000 AIR, UL 198L Catalog Numbers LP-CC-TM LP-CC-1TM LP-CC-3 LP-CC-6 LP-CC-12 LP-CC-fl LP-CC-1fl LP-CC-3 LP-CC-6 LP-CC-15 LP-CC- LP-CC-1 LP-CC-3TM LP-CC-7 LP-CC-20 LP-CC-1 LP-CC-2 LP-CC-4 LP-CC-7TM LP-CC-25 LP-CC-1* LP-CC-2 LP-CC-4TM LP-CC-8 LP-CC-30 LP-CC-1 LP-CC-2TM LP-CC-5 LP-CC-9 -- LP-CC-1 LP-CC-2 LP-CC-5fl LP-CC-10 -- Carton Quantity and Weight Ampere Ratings Weight* Carton Qty. Lbs. Kg. 10 .193 .088 0-30 *Weight per carton. Recommended fuseblocks/fuseholders for Class CC 600V fuses See Data Sheets listed below * Open fuseblocks - 1105 * Finger-safe fuseholders - 1109, 1102, 1103, 1151 * Panel-mount fuseholders - 2114, 2113 * In-line fuseholders - 2126 General Information: LP-CC LOW-PEAK YellowTM Fuse * A superior all-purpose, space-saving branch circuit fuse that meets most protection requirements up to 30A. * Very compact; physical size is only TM 1TM (10.3mm 38.1mm) with rejection tip. * The unique yellow color makes it easy to tell that the correct fuse type is installed. * Faster response to damaging short-circuit currents and higher interrupting rating than mechanical overcurrent protective devices. 200,000A Interrupting Rating * Maximum interrupting rating for available fault current in today's large capacity systems. * Helps ensure that future growth will not obsolete the system. Dual Characteristics * Time-delay to avoid unwanted fuse openings from surge currents. * Fast speed of response under short-circuit conditions for a high degree of current-limitation. * ADVANTAGE: The LOW-PEAK (R) fuse can be sized close to full load ratings for maximum overload and short-circuit protection. * ADVANTAGE: Can be used where either a time-delay or a fast-acting fuse is needed, making selection easier and reducing spare fuse inventories for substantial cost reduction. Superior Motor Protection * For protection of small horsepower motor circuits. * Proper sizing can provide Type "2" coordinated protection for NEMA and IEC motor controllers. * Motors receive maximum protection against burnout from overloads and single phasing. Current-Limiting Effects Prospective Short- *Let-Through Current (Apparent RMS Symmetrical) Circuit Current 1A 2A 15A 20A 25A 30A 1,000 100 135 240 305 380 435 3,000 140 210 350 440 575 580 5,000 165 255 420 570 690 710 10,000 210 340 540 700 870 1,000 20,000 260 435 680 870 1,090 1,305 30,000 290 525 800 1,030 1,300 1,520 40,000 315 610 870 1,150 1,390 1,700 50,000 340 650 915 1,215 1,520 1,820 60,000 350 735 1,050 1,300 1,650 1,980 80,000 390 785 1,130 1,500 1,780 2,180 100,000 420 830 1,210 1,600 2,000 2,400 200,000 525 1,100 1,600 2,000 2,520 3,050 *RMS Symmetrical Amperes Short-Circuit NOTE: To calculate Ip (Ipeak) multiply IRMS value 2.3. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 10-2-02 SB02295 Form No. LP-CC Page 1 of 2 Data Sheet: 1023 Bussmann(R) LOW-PEAK(R) LP-CC AMPERE RATING 2-8/10 300 1-1/4 200 100 80 60 50 40 30 2,000 800 1,000 400 500 600 300 200 80 100 20 1,000 CURRENT IN AMPERES 100 10 1 PROSPECTIVE SHORT-CIRCUIT CURRENT-SYMMETRICAL RMS AMPS .4 .01 AMPERE RATING 600 500 400 10 .1 30 25 20 15 1,000 800 40 50 60 1 2,000 30 10 3,000 20 100 TIME IN SECONDS 4,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 200 10 3 3TM 4 4TM 6 8 10 12 15 20 25 30 TM fl 1 1 Time-Delay Fuses Class CC - 600 Volt, TM to 30 Amps The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10-2-02 SB02295 Form No. LP-CC Page 2 of 2 Data Sheet: 1023