TX
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Rating
Nominal switching capacity Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Max. switching power Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
Max. switching voltage 220V DC
Max. switching current Standard contact: 2 A, AgPd contact: 1 A
Min. switching capacity (Reference value)*110µA 10mV DC
Nominal operating
power
Single side stable 140 mW (1.5 to 24 V DC), 270 mW (48 V DC)
1 coil latching 100 mW (1.5 to 24 V DC)
2 coil latching 200 mW (1.5 to 24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial) Between open contacts 1,500 V (10×160µs) (FCC Part 68)
Between contacts and coil 2,500 V (2×10µs) (Telcordia)
Temperature rise (at 20°C 68°F)Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20°C 68°F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 108 (at 180 cpm)
Electrical Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm)
Conditions Conditions for operation, transport and storage*2Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil)
[–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 2 g .071 oz
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TX2-5V, 10 pcs.
Operating speed: 180 cpm
0.2
0.3
0.4
0.5
1.0
2.0
3.0
20 30 50 100 200 300
DC resistive load
0Contact voltage, V
Switching current, A
1.0 2.0
100
50
30
20
10
0
Switching current, A
No. of operations ×104
30V DC
resistive load
0
10
100 10,0001,00010
Max.
Max.
Min.
Min.
20
30
40
50
60
70
80
90
100
No. of operations, ×104
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage
4. Electrical life (2A 30V DC resistive load)
Tested sample: TX2-5V, 6 pcs.
Operating speed: 20 cpm
Change of pick-up and drop-out voltage Change of contact resistance
5-(1). Coil temperature rise
Tested sample: TX2-5V, 6 pcs.
Point measured: Inside the coil
Ambient temperature: 25°C 77°F, 85°C 185°F
101
Max.
Min.
Min.
0
10
20
30
40
50
60
70
80
90
100
23456789
Max.
No. of operations, ×104
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage
101
Max.
Min.
0
10
20
30
40
50
60
70
80
90
100
23456789
No. of operations, ×104
Contact resistance, mΩ
10
30
60
70
100 120 150
0
20
40
50
110 130 140
2A
2A
0A
0A
+25°C
+85°C
Coil applied voltage, %
Temperature rise, °C
+77°F
+185°F
ASCTB18E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e