TL1453C
DUAL PULSE-WIDTH-MODULATION CONTROL CIRCUIT
SLVS039A – FEBRUARY 1990 – REVISED DECEMBER 1990
2POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) 41 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Amplifier input voltage 20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Collector output voltage 51 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Collector output current 21 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA –20°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE 1: All voltage values are with respect to network ground terminal.
DISSIPATION RATING TABLE
PACKAGE TA ≤ 25°C
POWER RATING DERATING FACTOR
ABOVE TA = 25°CTA = 85°C
POWER RATING
N1000 mW 8 mW/°C520 mW
NS 725 mW 5.8 mW/°C 397 mW
recommended operating conditions
MIN MAX UNIT
Supply voltage, VCC 3.6 40 V
Amplifier input voltage, VI1.05 1.45 V
Collector output voltage, VO50 V
Collector output current 20 mA
Current into feedback terminal 45 µA
Feedback resistor, RF100 kΩ
T iming capacitor, CT150 15000 pF
T iming resistor, RT5.1 100 kΩ
Oscillator frequency 1 500 kHz
Operating free-air temperature, TA–20 85 °C
electrical characteristics over recommended operating free-air temperature range, VCC = 6 V,
f = 200 kHz (unless otherwise noted)
reference section
PARAMETER TEST CONDITIONS MIN TYP†MAX UNIT
Output voltage (pin 16) IO = 1 mA 2.4 2.5 2.6 V
p
ut voltage change with tem
p
TA = –20°C to 25°C –0.1% ±1%
u
u
v
w
u
TA = 25°C to 85°C –0.2% ±1%
Input regulation VCC = 3.6 V to 40 V 2 12.5 mV
Output regulation IO = 0.1 mA to 1 mA 1 7.5 mV
Short-circuit output current VO = 0 3 10 30 mA
†All typical values are at TA = 25°C.