–1– AECTB6E 201408-T
ORDERING INFORMATION
PRODUCT TYPES
Terminal type (Mounting hole 3mm standard type/Mounting hole 3mm without boss type/2 boss type/Side pin type)
Long Stroke and Sliding
Contact Construction
Sealed Switches
TURQUOISE STROKE
SWITCHES
Actuator
Operating
Force OF
(Max.)
Mounting hole 3mm standard type
Mounting hole
3mm without
boss type
Right 2 boss
type
Left 2 boss
type
Right side pin
type
Left side pin
type
Solder
terminal
PC
right angle
terminal
PC
left angle
terminal
PC board
terminal
Solder
terminal
Solder
terminal
Solder
terminal
Solder
terminal
Pin plunger 1.5N ASQ10410 ASQ10710 ASQ10810 ASQ11510 ASQ16410 ASQ17410 ASQ14410 ASQ15410
Leaf lever 1.7N ASQ10417 ASQ10717 ASQ10817 ASQ11517 ASQ16417 ASQ17417 ASQ14417 ASQ15417
Simulated leaf lever 1.5N ASQ10418 ASQ10718 ASQ10818 ASQ11518 ASQ16418 ASQ17418 ASQ14418 ASQ15418
(Unit: mm)
FEATURES
• For pin plunger type, it maintains a
long stroke OT (Over Travel) with over
2.2 mm on the NO side and over 2.5
mm on the NC side.
• Since contact force does not depend
on the operation stroke, the range of
possible use over the entire stroke is
greatly increased.
• High contact reliability to support
low level switching loads
• Highly effective sealing for
resistance against adverse
environments
• Silent operation with sliding contact
TYPICAL APPLICATIONS
• Automobiles (detection of door
opening and closing and shift lever
position, etc.)
• Household appliances (vacuum
cleaners, air conditioners, washing
machines, etc.)
13.3
10.1
5.4
RoHS compliant
ASQ1
Size of mounting hole
0: Mounting hole 3 mm
standard type
1: Mounting hole 3 mm
without boss type
4: Right side pin type
(solder terminal only)
5: Left side pin type
(solder terminal only)
6: Right 2 boss type
(solder terminal only)
7: Left 2 boss type
(solder terminal only)
Note: Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.
COM NO NC COM NC COM NO
Actuator
0: Pin plunger
7: Leaf lever
8: Simulated
leaf lever
Terminal
2: Wire leads right side type
(SPST-NC and
SPST-NO only)
3: Wire leads left side type
(SPST-NC and
SPST-NO only)
4: Solder
terminal
5: PC board
terminal
6: Wire leads
bottom type
7: PC board right angle
terminal
8: PC board left angle
terminal
Contact form
1: SPDT 2: SPST-NC
(wire lead type only)
3: SPST-NO
(wire lead type only)
Turquoise Stroke Switches (ASQ1)
–2– AECTB6E 201408-T
Wire leads bottom type (Mounting hole 3mm standard type)
Wire leads side type (Mounting hole 3mm standard type)
SPECIFICATIONS
Contact rating
1 mA 5 V DC to 100 mA 30 V DC
Note: Please consult us regarding 42 V DC rating.
Operation environment and conditions
Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly
depending on the load capacity. Please consult us.
Electrical characteristics
Characteristics
Note: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
Actuator Operating Force OF (Max.) Wire leads bottom type (Mounting hole 3mm standard type)
SPDT SPST-NC SPST-NO
Pin plunger 1.5N ASQ10610 ASQ10620 ASQ10630
Leaf lever 1.7N ASQ10617 ASQ10627 ASQ10637
Simulated leaf lever 1.5N ASQ10618 ASQ10628 ASQ10638
Actuator Operating Force OF (Max.)
Wire leads right side type
(Mounting hole 3mm standard type)
Wire leads left side type
(Mounting hole 3mm standard type)
SPST-NC SPST-NO SPST-NC SPST-NO
Pin plunger 1.5N ASQ10220 ASQ10230 ASQ10320 ASQ10330
Leaf lever 1.7N ASQ10227 ASQ10237 ASQ10327 ASQ10337
Simulated leaf lever 1.5N ASQ10228 ASQ10238 ASQ10328 ASQ10338
Item Specifications
Ambient and storage temperature –40°C to +85°C (no freezing and condensing)
Allowable operating speed 30 to 500 mm/sec.
Max. operating cycle rate 120 cpm
Dielectric strength (Initial) Between non-continuous terminals: 600 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms,
Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA)
Insulation resistance (Initial) Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.)
Contact resistance (Initial) Max. 1 Ω (by voltage drop 0.1 A 6 to 8 V DC)
Item Specifications
Electrical
switching
life
5 V DC 1 mA (Resistive load) Min. 5 × 105Switching frequency: 20 times/min.
Conduction ratio: 1:1
Pushbutton operation speed: 100 mm/s
Pushbutton switching position: free position (FP) to operation limit position (TTP)
16 V DC 50 mA (Resistive load) Min. 5 × 105
30 V DC 100 mA (Resistive load) Min. 2 × 105
Vibration resistance
(malfunction vibration resistance)
Single amplitude: 0.75 mm
Amplitude of vibration: 10 to 55 Hz (4 minutes cycle)
Direction and time: 30 minutes each in X, Y and Z directions
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle)
Acceleration: 43.1 m/s2
Direction and time: 30 minutes each in X, Y and Z directions
Shock resistance
(malfunction shock resistance)
Shock value: 980 m/s2
Direction and time: 5 times each in X, Y and Z directions
Vibration resistance endurance Frequency of vibration: 33.3 Hz, Acceleration: 43.1 m/s2
Direction and time: 8 hours each in X, Y and Z directions
Terminal strength 6 N min. (each direction) *Terminal deformation possible.
Heat resistance 85°C 500 hours
Cold resistance –40°C 500 hours
Humidity resistance 40°C 95% RH 500 hours
Thermal shock resistance 30 min. at 85°C to 30 min at –40°C for 1,000 cycles
Unit weight Approx. 0.8 g (terminal type), Approx. 5.4 g (wire leads side type)
Protection grade IP67 (except exposed terminal part of terminal type)
Turquoise Stroke Switches (ASQ1)
–3– AECTB6E 201408-T
Protection gread
1) JIS C0920: Waterproof type
A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes
under 1 m of water (with temperature difference between water and switch no larger than 5°C).
2) IEC 60529: IP67 (waterproof type)
A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes
under 1 m of water (with temperature difference between water and switch no larger than 5°C).
3) JIS D0203: Equivalent of D2
A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes
under 10 cm of water (with temperature difference between water and switch no larger than 30°C).
Operating characteristics
Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction.
2. Indicates operation load for NO contact to achieve ON status.
3. Indicates position for NC contact to achieve OFF status.
4. Indicates position for NO contact to achieve ON status.
5. Indicates position for NC contact to achieve ON status.
6. Indicates position for NO contact to achieve OFF status.
OPERATION CONCEPT DIAGRAM
DATA
Applicable current range (Reference)
Characteristics Unit Pin plunger Leaf lever Simulated leaf lever
Operating Force (max. OF) *Note 2 N 1.5 1.7 1.5
Total travel Force (max. TF) (reference value) N (2.0) (3.1) (2.8)
Free Position (max. FP) From mounting boss and hole center line mm 9.2 11.5 14.4
From standoff 13.4 15.7 18.6
Operating Position on NC side
OP (NC) *Note 3
From mounting boss and hole center line mm 8.7±0.3 9.8±0.5 12.5±0.5
From standoff 12.9±0.3 14.0±0.5 16.7±0.5
Operating Position on NO side
OP (NO) *Note 4
From mounting boss and hole center line mm 8.4±0.3 9.3±0.5 12.0±0.5
From standoff 12.6±0.3 13.5±0.5 16.2±0.5
Release Position on NC side
RP (NC) *Note 5
From mounting boss and hole center line mm 8.8±0.3 10.1±0.5 12.9±0.5
From standoff 13.0±0.3 14.3±0.5 17.1±0.5
Release Position on NO side
RP (NO) *Note 6
From mounting boss and hole center line mm 8.5±0.3 9.6±0.5 12.4±0.5
From standoff 12.7±0.3 13.8±0.5 16.6±0.5
Over travel on NC side (min. OT (NC)) mm 2.5 3.1 3.3
Over travel on NO side (min. OT (NO)) mm 2.2 2.6 2.8
Total Travel Position (TTP)
(reference value)
From mounting boss and hole center line mm (5.9) (6.2) (8.7)
From standoff (10.1) (10.4) (12.9)
Contact form: terminal type
TF
RF
OF
Stroke
Operation load
Contact force
Range of possible use
Operation
load
NC side
NO side
RP (NC)
OP (NC)
OT (NC)
OT (NO)
TTP
OP (NO)
FP
RP (NO)
Standard (mounting boss and
hole center diameter or standoff)
0
NC side
NO side
0
(OFF)
Applicable range
100mA
1mA
0
30V5VDC
Turquoise Stroke Switches (ASQ1)
–4– AECTB6E 201408-T
DIMENSIONS
Terminal type: Mounting hole 3 mm, standard type Pin plunger
Terminal type: Leaf lever
(Unit: mm) General tolerance: ±0.25
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
1.9 dia.
FP 13.4 MAX.
OP (NC) 12.9±0.3
RP (NC) 13.0±0.3
OP (NO) 12.6±0.3
RP (NO) 12.7±0.3
TTP (10.1)
FP 9.2 MAX.
OP (NC) 8.7±0.3
RP (NC) 8.8±0.3
OP (NO) 8.4±0.3
RP (NO) 8.5±0.3
TTP (5.9)
1.2
8.4±0.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
3.2±0.1
4.1
13.3±0.15
C0.3
0.4
1.5
3.0+0.1
–0
3.0+0
–0.1 dia.
8.3±0.1 3.7 4.2
5.9
5.1
3.0+0.3
–0.2
Operating Force (max. OF) 1.5N
Free
Position
(max. FP)
From mounting boss
and hole center line 9.2mm
From standoff 13.4mm
Operating
Position on
NC side
OP (NC)
From mounting boss
and hole center line 8.7±0.3mm
From standoff 12.9±0.3mm
Operating
Position on
NO side
OP (NO)
From mounting boss
and hole center line 8.4±0.3mm
From standoff 12.6±0.3mm
Release
Position on
NC side
RP (NC)
From mounting boss
and hole center line 8.8±0.3mm
From standoff 13.0±0.3mm
Release
Position on
NO side
RP (NO)
From mounting boss
and hole center line 8.5±0.3mm
From standoff 12.7±0.3mm
Over travel on NC side
(min. OT (NC)) 2.5mm
Over travel on NO side
(min. OT (NO)) 2.2mm
CAD Data
External dimensions
Note: When switching at high speed or under shock, lever endurance may drop. Therefore,
please be sure to conduct an endurance evaluation under actual switching conditions.
1.9 dia.
FP 15.7 MAX.
FP 11.5 MAX.
14.0
(18°)
TTP (10.4)
3.3
OP (NO) 9.3±0.5
RP (NO) 9.6±0.5
OP (NC) 9.8±0.5
RP (NC) 10.1±0.5
OP (NC) 14.0±0.5
RP (NC) 14.3±0.5
OP (NO) 13.5±0.5
RP (NO) 13.8±0.5
TTP (6.2)
0.5
R1.2
C0.3
1.2
8.4±0.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
3.0+0.3
–0.2
3.0+0.1
–0
4.2
3.7
5.9
5.1
1.2
0.4
1.5
3.0+0
–0.1 dia.
8.3±0.1
3.2±0.1
0.2
Operating Force (max. OF) 1.7N
Free
Position
(max. FP)
From mounting boss
and hole center line 11.5mm
From standoff 15.7mm
Operating
Position on
NC side
OP (NC)
From mounting boss
and hole center line 9.8±0.5mm
From standoff 14.0±0.5mm
Operating
Position on
NO side
OP (NO)
From mounting boss
and hole center line 9.3±0.5mm
From standoff 13.5±0.5mm
Release
Position on
NC side
RP (NC)
From mounting boss
and hole center line 10.1±0.5mm
From standoff 14.3±0.5mm
Release
Position on
NO side
RP (NO)
From mounting boss
and hole center line 9.6±0.5mm
From standoff 13.8±0.5mm
Over travel on NC side
(min. OT (NC)) 3.1mm
Over travel on NO side
(min. OT (NO)) 2.6mm
CAD Data
Turquoise Stroke Switches (ASQ1)
–5– AECTB6E 201408-T
Terminal type: Simulated leaf lever
PC board terminal: Mounting hole 3 mm without boss type
Terminal type: Right side pin type
External dimensions
Note: When switching at high speed or under shock, lever endurance may drop. Therefore,
please be sure to conduct an endurance evaluation under actual switching conditions.
2.8
FP 14.4 MAX.
FP 18.6 MAX.
1.9dia.
15.0
R2.0
TTP (8.7)
OP (NO) 12.0±0.5
RP (NO) 12.4±0.5
OP (NC) 12.5±0.5
RP (NC) 12.9±0.5
TTP (12.9)
OP (NO) 16.2±0.5
RP (NO) 16.6±0.5
OP (NC) 16.7±0.5
RP (NC) 17.1±0.5
(18°)
3.3
0.5
R1.2
0.2
R0.5
C0.3
1.2
8.4±0.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
3.0+0
–0.1 dia.
1.5
0.4
8.3±0.1
3.0+0.3
–0.2
4.2
5.9
3.7
5.1
3.0+0.1
–0
1.2
3.2±0.1
Operating Force (max. OF) 1.5N
Free
Position
(max. FP)
From mounting boss
and hole center line 14.4mm
From standoff 18.6mm
Operating
Position on
NC side
OP (NC)
From mounting boss
and hole center line 12.5±0.5mm
From standoff 16.7±0.5mm
Operating
Position on
NO side
OP (NO)
From mounting boss
and hole center line 12.0±0.5mm
From standoff 16.2±0.5mm
Release
Position on
NC side
RP (NC)
From mounting boss
and hole center line 12.9±0.5mm
From standoff 17.1±0.5mm
Release
Position on
NO side
RP (NO)
From mounting boss
and hole center line 12.4±0.5mm
From standoff 16.6±0.5mm
Over travel on NC side
(min. OT (NC)) 3.3mm
Over travel on NO side
(min. OT (NO)) 2.8mm
CAD Data
PC board terminal
PC board pattern
0.9
5.08±0.155.08±0.15
3.0+0.3
0.2
C0.2
5.08±0.15.08±0.1
1.0+0.1
0 dia.
CAD Data
CAD Data External dimensions
8.3±0.1
C 0.2
8.3
2.6±0.05
2.2±0.05 dia.
2.6±0.05
5.0
1.9 dia.
0.4
1.5
FP 13.4 MAX.
RP (NC) 13.0±0.3
OP (NC) 12.9±0.3
RP (NO) 12.7±0.3
OP (NO) 12.6±0.3
TTP (10.1)
FP 9.2 MAX.
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
TTP (5.9)
5.1
5.94.2
3.7
0.2
+0.3
3.0
1.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
Turquoise Stroke Switches (ASQ1)
–6– AECTB6E 201408-T
Terminal type: Left side pin type
Terminal type: Right 2 boss type
Terminal type: Left 2 boss type
CAD Data External dimensions
8.3±0.1
C 0.2
8.3
2.6±0.05
2.2±0.05 dia.
2.6±0.05
5.0
1.9 dia.
0.4
1.5
FP 13.4 MAX.
RP (NC) 13.0±0.3
OP (NC) 12.9±0.3
RP (NO) 12.7±0.3
OP (NO) 12.6±0.3
TTP (10.1)
FP 9.2 MAX.
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
TTP (5.9)
5.1
5.94.2
3.7
0.2
+0.3
3.0
1.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
CAD Data External dimensions
8.3±0.1
2-3.0 dia.
C0.3
1.5
1.9 dia.
0.4
1.5
FP 13.4 MAX.
RP (NC) 13.0±0.3
OP (NC) 12.9±0.3
RP (NO) 12.7±0.3
OP (NO) 12.6±0.3
TTP (10.1)
FP 9.2 MAX.
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
TTP (5.9)
5.1
5.94.2
3.7
0.2
+0.3
3.0
1.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
0.1
+0
CAD Data External dimensions
C0.3
2-3.0 dia.
8.3±0.1
1.5
1.9 dia.
0.4
1.5
FP 13.4 MAX.
RP (NC) 13.0±0.3
OP (NC) 12.9±0.3
RP (NO) 12.7±0.3
OP (NO) 12.6±0.3
TTP (10.1)
FP 9.2 MAX.
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
TTP (5.9)
5.1
5.94.2
3.7
0.2
+0.3
3.0
1.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
0.1
+0
Turquoise Stroke Switches (ASQ1)
–7– AECTB6E 201408-T
Angle terminal type: Mounting hole 3 mm, standard type (Right type)
Angle terminal type: Mounting hole 3 mm, standard type (Left type)
C 0.2
5.08±0.15
5.08±0.15
0.9
2.0
3.95±0.15
FP 9.2 MAX.
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
TTP (5.9)
5.1
5.94.2
3.7
8.4±0.2
5.4
2.7
3.0 dia.
8.3±0.1
3.2±0.1
0
+0.1
3.0
13.3±0.15
NCCOM NO
6.0±0.3
0.4
3.1±0.4
4.1
C0.3
1.9 dia.
5.4±0.15
0.1
+0
CAD Data External dimensions
C 0.2
3.0 dia.
5.08±0.15
5.08±0.15
COM 0.9 NO NC
13.3±0.15
5.4
2.7
3.2±0.1
1.9 dia.
5.4±0.15
8.4±0.2
RP (NO) 8.5±0.3
OP (NO) 8.4±0.3
RP (NC) 8.8±0.3
OP (NC) 8.7±0.3
FP 9.2 MAX.
TTP (5.9)
8.3±0.1
2.0
3.95±0.15
3.1±0.4
4.1
0.4
4.2 5.9
5.1
3.00
+0.1
3.7
6.0±0.3
C0.3
0.1
+0
CAD Data External dimensions
Turquoise Stroke Switches (ASQ1)
–8– AECTB6E 201408-T
Wire leads bottom type: Mounting hole 3 mm, standard type
Wire leads right side type: Mounting hole 3 mm, standard type
Wire leads left side type: Mounting hole 3 mm, standard type
4.2
5.2
3.6
2.6
0.3
0.3
4.53 4.53
3.2
R 0.3
R 0.2
1.9 dia.
1.4 dia.
Wire lead thickness
Wire lead color
:
:
:
:
0.3mm2
COM
NC
NO
····
·······
·······
Black
Red
White
8.4±0.2
5.4±0.15
C 0.3
3.0+0
0.1 dia.
TTP (5.9)
OP (NO) 8.4±0.3
OP (NC) 8.7±0.3
FP 9.2 MAX.
5.9
3.7
4.3
2.2
300±10
5.0±2
8.3±0.1
5.1
3.2±0.1
2.7
5.4
13.3±0.15
3.0+0.1
0
CAD Data External dimensions
3.0+0
0.1 dia.
R 2.0
1.9 dia.
8.4±0.2
5.4±0.15
C 0.3
R 0.5
R 0.5
R 0.5
TTP (5.9)
OP (NO) 8.4±0.3
OP (NC) 8.7±0.3
FP 9.2 MAX.
5.9
3.7
1.0
1.4 dia.
4.5
5.2
4.3
300±102.4
5.0±2
8.3±0.1
5.1
3.2±0.1
2.7
5.4
13.3±0.15
3.0+0.1
0
Wire lead thickness
Wire lead color
:
:
:
:
0.3mm2
COM
NC
NO
····
·······
·······
Black
Red
White
0.3
CAD Data External dimensions
1.9 dia.
8.4±0.2
5.4±0.15
C 0.3
R 0.5
R 0.5
TTP (5.9)
OP (NO) 8.4±0.3
OP (NC) 8.7±0.3
FP 9.2 MAX.
5.9
3.7
1.4 dia.
4.5
5.2
5.0±2
4.3
8.3±0.1
5.1
1.0
3.2±0.1
2.7
5.4
13.3±0.15
3.0+0.1
0
300±10 2.4
R 0.5
3.0+0
0.1 dia.
Wire lead thickness
Wire lead color
:
:
:
:
0.3mm2
COM
NC
NO
····
·······
·······
Black
Red
White
R 2.0
0.3
CAD Data External dimensions
Turquoise Stroke Switches (ASQ1)
–9– AECTB6E 201408-T
CAUTIONS FOR USE
Soldering conditions
The application of excessive heat upon
the switch when soldering can cause
degradation of switch operation.
Therefore, be sure to keep within the
conditions given below.
Manual soldering: use soldering irons
(max. 350°C, within 3 seconds at each
terminal) capable of temperature
adjustment. This is to prevent
deterioration due to soldering heat. Care
should be taken not to apply force to the
terminals during soldering.
(More than one second interval is
required to apply heat at each terminal.)
Mounting
Please avoid use in which load would be
applied to the sides (hatch part (both
sides) shown below) of the switch in the
direction indicated by the arrows. This
could cause erroneous operation. Also,
when using a metal installation board,
please make allowance for burr direction
designation and burr suppressing, etc.,
so that the burr side will not be on the
switch installation side.
1) To secure the switch, please use an
M3 small screw on a flat surface and
tighten using a maximum torque of 0.29
N·m. It is recommended that both flat
metal washer and spring washers be
used with the screws and adhesive be
applied to lock the screws to prevent
loosening of the screws. Please make
sure not to apply adhesive onto the
moving parts.
2) Be sure to maintain adequate
insulating clearance between each
terminal and ground.
3) Although it is possible to directly
operate the pin plunger type from the
lateral direction, please consult us if
doing so.
4) After mounting please make sure no
tensile load will be applied to the switch
terminals.
5) Range of possible use: Please set the
operation position to within the ranges in
the following table so that there is
sufficient insulation distance and to
maintain contact reliability.
6) PC board terminal type should be
used if the products are to be soldered on
the PC board. Solder terminal type is not
for soldering on PC board.
Cautions regarding the circuit
1) In order to prevent malfunction in set
devices caused by bounce and chattering
during the ON-OFF switch operation,
please verify the validity of the circuit
under actual operating conditions and
temperature range.
2) When switching inductive loads
(relays, solenoids, buzzers, etc.), an arc
absorbing circuit is recommended to
protect the contacts.
Please verify under actual
conditions.
Please be sure to conduct quality
verification under actual operating
conditions in order to increase reliability
during actual use.
Selection of switch
Please make your selection so that there
will be no problems even if the operating
characteristics vary up to ±20% from the
standard values.
Oil-proof and chemical-proof
characteristics
The rubber cap swells when exposed to
oil and chemicals. The extent of swelling
will vary widely depending on the type
and amount of oil and chemicals.
Check with the actual oil or chemicals
used. In particular, be aware that solvents
such as freon, chlorine, and toluene
cannot be used.
Environment
1) Although continuous operation of the
switch is possible within the range of
ambient temperature (humidity), as the
humidity range differs depending on the
ambient temperature, the humidity range
indicated below should be used.
Continuous use near the limit of the
range should be avoided.
2) This humidity range does not
guarantee permanent performance.
Other
1) Please remember that this switch
cannot be used under water. Also, please
be warned that switching and sudden
temperature changes with the presence
of water droplets can cause seepage into
the switch.
2) Keep away from environments where
silicon based adhesives, oil or grease are
present as faulty contacts may result
from silicon oxide. Do not use in areas
where flammable or explosive gases from
gasoline and thinner, etc., may be
present.
3) When using the lever type, please be
careful not to apply unreasonable load
from the reverse or lateral directions of
operation.
4) Do not exceed the total travel position
(TTP) and press the actuator. This could
cause operation failure. Also, when
switching at high speed or under shock
even within the operation limit, the
working life may decrease. Therefore,
please be sure to verify the quality under
actual conditions of use.
5) Please make considerations so that
the switch does not become the stopper
for the moving part.
6) Please do not pull wire leads
constantly.
Actuator
Plunger/lever free
From mounting
boss and hole
center line
From standoff
Pin plunger >9.2 mm >13.4 mm
Leaf lever >10.7 mm >14.9 mm
Simulated
leaf lever >13.5 mm >17.7 mm
Actuator
Plunger/Lever pushed
From mounting
boss and hole
center line
From standoff
Pin plunger 7.8 to 5.9 mm 12.0 to 10.1 mm
Leaf lever 8.4 to 6.2 mm 12.6 to 10.4 mm
Simulated
leaf lever 11.1 to 8.7 mm 15.3 to 12.9 mm
Acceptable range
(Avoid
condensation when
used at temperatures
higher than 0°C)
(Avoid freezing when
used at temperatures
lower than 0°C)
95
50
5
–40 0 +85
Temperature, °C
Humidity, %R.H.