For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil®
shield (100% coverage), 24 AWG drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
124 7x32 TC - Tinned Copper 0.6096
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Trade Name Insulation Material Dia. (mm)
Datalene® FHDPE - Foam High Density Polyethylene 1.7272
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 4.496 mm
Pair
Pair Color Code Chart:
Number Color
1Red & Black
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +60°C
UL Temperature Rating: 60°C
Bulk Cable Weight: 23.811 Kg/Km
Max. Recommended Pulling Tension: 73.395 N
Min. Bend Radius/Minor Axis: 44.450 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG
Page 1 of 3 08-21-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1800B Multi-Conductor - Single-Pair Cable
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Other Specification: AES/EBU
Flame Test
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 1801B
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
110
Nom. Inductance:
Inductance (µH/m)
0.59058
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
39.372
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
85.306
Nominal Velocity of Propagation:
VP (%)
76
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
77.7597
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
.384 2.26389
.7056 3.05133
.768 3.14976
1.024 3.51067
1.4112 3.90439
1.536 3.97001
2.048 4.29811
2.8224 4.62621
3.072 4.75745
4.096 5.15117
5.6448 5.77456
6.144 6.00423
8.192 6.59481
Page 2 of 3 08-21-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1800B Multi-Conductor - Single-Pair Cable
11.2896 7.34944
12.288 7.5463
24.576 10.1055
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.75 Amps per conductor @ 25°C
Notes (Overall)
Notes: For cross-connect use with 1803F (et al.) Digital Audio Snake Cables. The jacket and shield are bonded so both can be
removed with automatic stripping equipment.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1800B T5XU1000 305 MT 7.711 KG GRAY T5X #24 FHDPE FS PR PVC
1800B T5X1000 305 MT 8.165 KG GRAY T5X C #24 FHDPE FS PR PVC
1800B T5X500 152 MT 4.309 KG GRAY T5X C #24 FHDPE FS PR PVC
1800B 007U1000 305 MT 7.711 KG VIOLET #24 FHDPE FS PR PVC
1800B 0071000 305 MT 8.165 KG VIOLET C #24 FHDPE FS PR PVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 07-29-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 08-21-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1800B Multi-Conductor - Single-Pair Cable