CL-CU series
Compact Time Delay Relay
Delay on operate timing mode
Fixed, knob or resistor adjustable types
10A output relay with DPDT contacts
Variety of mounting options
Various models time from 0.1 to 120 sec.
No timing cycle interrupt transfer (CL only)
File E22575
File LR15734
Environmental Data
Temperature Range: Storage: -55°C to +85°C.
Operating: -10°C to +55°C.
Mechanical Data
Termination: 0.187 in. (4.75mm) quick-connect.
Enclosure: Yellow plastic case (see outline drawings for various options).
Knob adjustable types have dial scale for reference only.
Sockets: Solder, printed circuit and screw terminal sockets available.
Weight: 3.5 oz. (99g) approximately.
CL Ordering Information – Boldface items listed below are normally maintained in stock for immediate delivery.
Voltage Time Adjustment Wiring Dia. Part Number
24VAC 0.1 to 10 Sec. Knob 1 CLB-51-30010
24VAC 0.1 to 10 Sec. Resistor 2 CLF-42-30010
0.1 to 10 Sec. CLB-51-70010
120VAC 0.3 to 30 Sec. Knob 1 CLB-51-70030
1.2 to 120 Sec. CLB-51-70120
120VAC 3 Sec. Fixed 1 CLA-41-70003
30 Sec. CLA-41-70030
0.1 to 10 Sec. CLF-41-70010
120VAC 0.1 to 10 Sec. Resistor 2 CLF-42-70010
1.2 to 120 Sec. CLF-41-70120
Voltage Time Adjustment Wiring Dia. Part Number
12VDC 0.1 to 10 Sec. Knob 1 CLD-51-20010
12VDC 10 Sec. Fixed 1 CLC-41-20010
12VDC 1.2 to 120 Sec. Resistor 2 CLH-41-20120
24VDC 5 Sec. Fixed 1 CLC-41-30005
0.1 to 10 Sec. CLH-41-30010
24VDC 0.3 to 30 Sec. Resistor 2 CLH-41-30030
0.1 to 10 Sec. CLH-45-30010
41 style models (e.g. CLA-41-70010) have plain case.
42 style models (e.g. CLF-42-70010) have bracket mount case.
45 style models (e.g. CLH-45-30010) have bracket mount case with test button.
51 style models (e.g. CLB-51-30010) have plain case with knob.
CU Timing Specifications
Timing Ranges: From 1.0 to 10 sec. through 1.0 to 120 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types:–0, +20% of max. specified at high end of timing
range; min. specified, or less, at low end.
Fixed Types: ±5%.
Res. Adj. Types: ±10% at high end of timing range; min. specified, or
less, at low end.
Repeatability (for AC units add ±1 cycle 60 Hz.): ±3%.
Release Time: 150 ms, typ.; 225 ms, max.
Recycle Time: 150 ms, typ.; 225 ms, max.
Note: On CU types the switching contact may momentarily transfer if the timing interval is
interrupted. CL types have no timing cycle interrupt transfer.
Input Voltages & Limits @ 25°C
Voltage Nominal Minimum Maximum
Type Voltage Voltage Voltage
AC 24 20 28
120 105 130
DC 12 11 13
24 20 32
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
1/3 HP @ 120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Input Data @ 25°C
Voltage: 24 & 120VAC and 12 & 24VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Timing Mode
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
TIME
INPUT
VOLTAGE ON
OFF
N.O. RELAY
CONTACTS ON
OFF
CL Timing Specifications
Timing Ranges: From 0.1 to 1.0 sec. through 1.2 to 120 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types:0, +20% of max. specified at high end of timing
range; min. specified, or less, at low end.
Fixed Types: ±5%.
Res. Adj. Types: ±10% at high end of timing range; min. specified, or
less, at low end.
Repeatability (for AC units add ±1 cycle 60 Hz.): ±3%.
Release Time: 100 ms, typ.; 150 ms, max.
Recycle Time: 100 ms, typ.; 150 ms, max.
Specifications and availability subject to change without notice.
13C2580 Printed in U.S.A. IH/4-00
Tyco Electronics Corporation - P&B, Winston-Salem, NC 27102
Technical Support Center: 1-800-522-6752, www.pandbrelays.com
CU Ordering Information – Boldface items listed below are normally maintained in stock for immediate delivery.
Wiring Diagrams – Bottom Views
Outline Dimensions
Voltage Time Adjustment Wiring Dia. Part Number
1 to 10 Sec. CUF-41-70010
1 to 10 Sec. CUF-42-70010
120VAC 1 to 30 Sec. Resistor 2 CUF-41-70030
1 to 120 Sec. CUF-41-70120
1 to 120 Sec. CUF-42-70120
1 to 10 Sec. CUH-41-30010
1 to 10 Sec. CUH-42-30010
24VDC 1 to 120 Sec. Resistor 2 CUH-41-30120
1 to 120 Sec. CUH-42-30120
41 style models (e.g. CUA-41-70010) have plain case.
42 style models (e.g. CUA-42-70010) have bracket mount case.
51 style models (e.g. CUB-51-70010) have plain case with knob.
Voltage Time Adjustment Wiring Dia. Part Number
24VAC 10 Sec. Fixed 1 CUA-41-30010
1 to 10 Sec. CUF-41-30010
24VAC 1 to 10 Sec. Resistor 2 CUF-42-30010
1 to 10 Sec. CUB-51-70010
120VAC 1 to 30 Sec. Knob 1 CUB-51-70030
1 to 60 Sec. CUB-51-70060
1 to 120 Sec. CUB-51-70120
1 Sec. CUA-41-70001
3 Sec. CUA-41-70003
3 Sec. CUA-42-70003
120VAC 5 Sec. Fixed 1 CUA-41-70005
10 Sec. CUA-41-70010
10 Sec. CUA-42-70010
30 Sec. CUA-42-70030
120 Sec. CUA-41-70120
123
456
789
AB
51 Style
.125
(3.18)
.078
(1.98)
.187 ± .002
(4.75 ± .05)
.250
(6.35)
HEADER .281 REF.
(7.14)
THICKNESS 0.20
(.51)
Terminal Dimensions
.187" (4.74mm)
Quick Connect/Solder
1.906 MAX.
(48.41)
.281 REF.
(7.14)
2.500
(63.50)
.312 TYP.
(7.92)
1.531 MAX.
(38.89)
.645 TYP.
(15.88) .375
(9.53)
1.906 MAX.
(48.41)
2.90 MAX.
(73.66)
.437
(11.10)
.078 R TYP.
(1.98) .75 ± .015
(19.05 ± .38)
1.406 MAX.
(35.71)
.07
(1.78)
.06
(1.52)
.625 MAX.
(15.88)
2.156 MAX.
(15.46)
.281 REF.
(7.14)
42 & 45 Style
41 Style
1.531 MAX.
(38.89)
1.406 MAX.
(35.71)
SEATED HEIGHT ABOVE
CHASSIS MOUNTED
IN SOCKET : (57.2mm)
+-
13
46
79
AB79
AB
2
5
INPUT
(DC POLARITY INDICATED) **
+-
Fig. 1 Fig. 2
1
4
3
6
INPUT
(DC DC POLARITY INDICATED) **
External Resistor Selection Chart
See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook.
** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to + and low side to “–”.