1E2A
Cylindrical Proximity Sensor
E2A
High quality for extra
long life in daily use
wide portfolio range through modular concept
designed and tested for extra long life
IP67 and IP69k for highest protection in wet
environments
continuously high quality level through specialized
manufacturin g process
DC 3-wire and DC 2-wire models
Normally open (NO), normally closed (NC) and
antivalent (NO+NC) models
up to 30mm sensing distance
Stainless steel and brass housings
Pre-wired versions with different cable materials
and diameters, M8 and M12 connector types,
pre-wired types with cable end connectors
Ordering Information
DC 3-wire models (NO + NC: DC 4-wire) *2
Size Sensing
distance Connec-
tion Body
material
Thread
length
(overall
length)
Output
confi-
guration Operation mode NO Operation mode NC
M8
Shiel-
ded 2.0 mm
Pre-wired
Stain-
less
steel*1
*1.
27 (40) PNP
E2A-S08KS02-WP-B1 2M E2A-S08KS02-WP-B2 2M
NPN
E2A-S08KS02-WP-C1 2M E2A-S08KS02-WP-C2 2M
49 (62) PNP
E2A-S08LS02-WP-B1 2M E2A-S08LS02-WP-B2 2M
NPN
E2A-S08LS02-WP-C1 2M E2A-S08LS02-WP-C2 2M
M12
connector
27 (43) PNP
E2A-S08KS02-M1-B1 E2A-S08KS02-M1-B2
NPN
E2A-S08KS02-M1-C1 E2A-S08KS02-M1-C2
49 (65) PNP
E2A-S08LS02-M1-B1 E2A-S08LS02-M1-B2
NPN
E2A-S08LS02-M1-C1 E2A-S08LS02-M1-C2
M8
connector
(3-pin)
27 (39) PNP
E2A-S08KS02-M5-B1 E2A-S08KS02-M5-B2
NPN
E2A-S08KS02-M5-C1 E2A-S08KS02-M5-C2
49 (61) PNP
E2A-S08LS02-M5-B1 E2A-S08LS02-M5-B2
NPN
E2A-S08LS02-M5-C1 E2A-S08LS02-M5-C2
M8
connector
(4-pin)
27 (39) PNP
E2A-S08KS02-M3-B1 E2A-S08KS02-M3-B2
NPN
E2A-S08KS02-M3-C1 E2A-S08KS02-M3-C2
49 (61) PNP
E2A-S08LS02-M3-B1 E2A-S08LS02-M3-B2
NPN
E2A-S08LS02-M3-C1 E2A-S08LS02-M3-C2
Non-
shiel-
ded 4.0 mm
Pre-wired 27 (40) PNP
E2A-S08KN04-WP-B1 2M E2A-S08KN04-WP-B2 2M
NPN
E2A-S08KN04-WP-C1 2M E2A-S08KN04-WP-C2 2M
49 (62) PNP
E2A-S08LN04-WP-B1 2M E2A-S08LN04-WP-B2 2M
NPN
E2A-S08LN04-WP-C1 2M E2A-S08LN04-WP-C2 2M
M12
connector
27 (43) PNP
E2A-S08KN04-M1-B1 E2A-S08KN04-M1-B2
NPN
E2A-S08KN04-M1-C1 E2A-S08KN04-M1-C2
49 (65) PNP
E2A-S08LN04-M1-B1 E2A-S08LN04-M1-B2
NPN
E2A-S08LN04-M1-C1 E2A-S08LN04-M1-C2
M8
connector
(3-pin)
27 (39) PNP
E2A-S08KN04-M5-B1 E2A-S08KN04-M5-B2
NPN
E2A-S08KN04-M5-C1 E2A-S08KN04-M5-C2
49 (61) PNP
E2A-S08LN04-M5-B1 E2A-S08LN04-M5-B2
NPN
E2A-S08LN04-M5-C1 E2A-S08LN04-M5-C2
M8
connector
(4 pin)
27 (39) PNP E2A-S08KN04-M3-B1 E2A-S08KN04-M3-B2
NPN E2A-S08KN04-M3-C1 E2A-S08KN04-M3-C2
49 (61) PNP E2A-S08LN04-M3-B1 E2A-S08LN04-M3-B2
NPN E2A-S08LN04-M3-C1 E2A-S08LN04-M3-C2
2Inductive Sensors
Size Sensing
distance Connec-
tion Body
material
Thread
length
(overall
length)
Output
confi-
guration Operation mode NO Operation mode NC Operation mode NO + NC
M12
Shiel-
ded 4.0 mm
Pre-wired Brass*3 34 (50) PNP
E2A-M1 2K S04 -W P-B 1 2M E2A-M12KS04-WP-B2 2M E2A-M12KS04-WP-B3 2M
NPN
E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M E2A-M12KS04-WP-C3 2M
56 (72) PNP
E2A-M12LS04-WP-B1 2M E2A-M12LS04-WP-B2 2M E2A-M12LS04-WP-B3 2M
NPN
E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M E2A-M12LS04-WP-C3 2M
M12
connector Brass*3 34 (48) PNP
E2A-M12KS04-M1-B1 E2A-M12KS04-M1-B2 E2A-M12KS04-M1-B3
NPN
E2A-M12KS04-M1-C1 E2A-M12KS04-M1-C2 E2A-M12KS04-M1-C3
56 (70) PNP
E2A-M12LS04-M1-B1 E2A-M12LS04-M1-B2 E2A-M12LS04-M1-B3
NPN
E2A-M12LS04-M1-C1 E2A-M12LS04-M1-C2 E2A-M12LS04-M1-C3
M8
connector
(3-pin) Brass*3 34 (48) PNP
E2A-M12KS04-M5-B1 E2A-M12KS04-M5-B2 n.a.
NPN
E2A-M12KS04-M5-C1 E2A-M12KS04-M5-C2 n.a.
56 (70) PNP
E2A-M12LS04-M5-B1 E2A-M12LS04-M5-B2 n.a.
NPN
E2A-M12LS04-M5-C1 E2A-M12LS04-M5-C2 n.a.
M8
connector
(4-pin) Brass*3 34 (48) PNP
E2A-M12KS04-M3-B1 E2A-M12KS04-M3-B2 n.a.
NPN
E2A-M12KS04-M3-C1 E2A-M12KS04-M3-C2 n.a.
56 (70) PNP
E2A-M12LS04-M3-B1 E2A-M12LS04-M3-B2 n.a.
NPN
E2A-M12LS04-M3-C1 E2A-M12LS04-M3-C2 n.a.
Non-
shiel-
ded 8.0 mm
Pre-wired Brass*3 34 (50) PNP
E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M E2A-M12KN08-WP-B3 2M
NPN
E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M E2A-M12KN08-WP-C3 2M
56 (72) PNP
E2A-M12LN08-WP-B1 2M E2A-M12LN08-WP-B2 2M E2A-M12LN08-WP-B3 2M
NPN
E2A-M12LN08-WP-C1 2M E2A-M12LN08-WP-C2 2M E2A-M12LN08-WP-C3 2M
M12
connector Brass*3 34 (48) PNP
E2A-M12KN08-M1-B1 E2A-M12KN08-M1-B2 E2A-M12KN08-M1-B3
NPN
E2A-M12KN08-M1-C1 E2A-M12KN08-M1-C2 E2A-M12KS08-M1-C3
56 (70) PNP
E2A-M12LN08-M1-B1 E2A-M12LN08-M1-B2 E2A-M12LS08-M1-B3
NPN
E2A-M12LN08-M1-C1 E2A-M12LN08-M1-C2 E2A-M12LS08-M1-C3
M8
connector
(3-pin) Brass*3 34 (48) PNP
E2A-M12KN08-M5-B1 E2A-M12KN08-M5-B2 n.a.
NPN
E2A-M12KN08-M5-C1 E2A-M12KN08-M5-C2 n.a.
56 (70) PNP
E2A-M12LN08-M5-B1 E2A-M12LN08-M5-B2 n.a.
NPN
E2A-M12LN08-M5-C1 E2A-M12LN08-M5-C2 n.a.
M8
connector
(4-pin) Brass*3 34 (48) PNP
E2A-M12KN08-M3-B1 E2A-M12KN08-M3-B2 n.a.
NPN
E2A-M12KN08-M3-C1 E2A-M12KN08-M3-C2 n.a.
56 (70) PNP
E2A-M12LN08-M3-B1 E2A-M12LN08-M3-B2 n.a.
NPN
E2A-M12LN08-M3-C1 E2A-M12LN08-M3-C2 n.a.
M18
Shiel-
ded 8.0 mm
Pre-wired Brass*3 39 (59) PNP
E2A-M1 8K S08 -W P-B 1 2M E2A-M18KS08-WP-B2 2M E2A-M18KS08-WP-B3 2M
NPN
E2A-M18KS08-WP-C1 2M E2A-M18KS08-WP-C2 2M E2A-M18KS08-WP-C3 2M
61 (81) PNP
E2A-M18LS08-WP-B 1 2M E2A-M18LS08-WP-B2 2M E2A-M18LS08-WP-B3 2M
NPN
E2A-M18LS08-WP-C 1 2M E2A-M18LS08-WP-C2 2M E2A-M18LS08-WP-C3 2M
M12
connector Brass*3 39 (53) PNP
E2A-M18KS08-M1-B1 E2A-M18KS08-M1-B2 E2A-M18KS08-M1-B3
NPN
E2A-M18KS08-M1-C1 E2A-M18KS08-M1-C2 E2A-M18KS08-M1-C3
61 (75) PNP
E2A-M18LS08-M1-B1 E2A-M18LS08-M1-B2 E2A-M18LS08-M1-B3
NPN
E2A-M18LS08-M1-C1 E2A-M18LS08-M1-C2 E2A-M18LS08-M1-C3
M8
connector
(3-pin) Brass*3 39 (53) PNP
E2A-M18KS08-M5-B1 E2A-M18KS08-M5-B2 n.a.
NPN
E2A-M18KS08-M5-C1 E2A-M18KS08-M5-C2 n.a.
61 (75) PNP
E2A-M18LS08-M5-B1 E2A-M18LS08-M5-B2 n.a.
NPN
E2A-M18LS08-M5-C1 E2A-M18LS08-M5-C2 n.a.
M8
connector
(4-pin) Brass*3 39 (53) PNP
E2A-M18KS08-M3-B1 E2A-M18KS08-M3-B2 n.a.
NPN
E2A-M18KS08-M3-C1 E2A-M18KS08-M3-C2 n.a.
61 (75) PNP
E2A-M18LS08-M3-B1 E2A-M18LS08-M3-B2 n.a.
NPN
E2A-M18LS08-M3-C1 E2A-M18LS08-M3-C2 n.a.
Non-
shiel-
ded 16.0 mm
Pre-wired Brass*3 39 (59) PNP
E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M E2A-M18KN16-WP-B3 2M
NPN
E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M E2A-M18KN16-WP-C3 2M
61 (81) PNP
E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M E2A-M18LN16-WP-B3 2M
NPN
E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M E2A-M18LN16-WP-C3 2M
M12
connector Brass*3 39 (53) PNP
E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2 E2A-M18KN16-M1-B3
NPN
E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2 E2A-M18KS16-M1-C3
61 (75) PNP
E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2 E2A-M18LS16-M1-B3
NPN
E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2 E2A-M18LS16-M1-C3
M8
connector
(3-pin) Brass*3 39 (53) PNP
E2A-M18KN16-M5-B1 E2A-M18KN16-M5-B2 n.a.
NPN
E2A-M18KN16-M5-C1 E2A-M18KN16-M5-C2 n.a.
61 (75) PNP
E2A-M18LN16-M5-B1 E2A-M18LN16-M5-B2 n.a.
NPN
E2A-M18LN16-M5-C1 E2A-M18LN16-M5-C2 n.a.
M8
connector
(4-pin) Brass*3 39 (53) PNP
E2A-M18KN16-M3-B1 E2A-M18KN16-M3-B2 n.a.
NPN
E2A-M18KN16-M3-C1 E2A-M18KN16-M3-C2 n.a.
61 (75) PNP
E2A-M18LN16-M3-B1 E2A-M18LN16-M3-B2 n.a.
NPN
E2A-M18LN16-M3-C1 E2A-M18LN16-M3-C2 n.a.
3E2A
*1. Material specificatio ns for stainless steel housing case: 1.4305 (W.-No. ), SUS 303 (AISI), 2346 (SS ). Please contact your OMRON representa tive for other stainless
steel materials.
*2. Please contact your OMRON representative for DC 2-wire models.
*3. Stainless steel models are also available. Please contact your OMRON representative.
Note:M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding
metal. Standard sensing models are thus available.
M30
Shiel-
ded 15.0 mm
Pre-wired Brass*3 44 (64) PNP
E2A-M3 0KS15 -WP -B1 2M E2A-M30KS15-WP-B2 2M E2A-M30KS15-WP-B3 2M
NPN
E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C 2 2M E2A-M30KS15-WP-C3 2M
66 (86) PNP
E2A-M30LS15-WP-B1 2M E2A-M30LS15-WP-B2 2M E2A-M30LS15-WP-B3 2M
NPN
E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M E2A-M30LS15-WP-C3 2M
M12
connector Brass*3 44 (58) PNP E2A-M30KS15-M1-B1 E2A-M30KS15-M1-B2
E2A-M30KS15-M1-B3
NPN E2A-M30KS15-M1-C1 E2A-M30KS15-M1-C2
E2A-M30KS15-M1-C3
66 (80) PNP E2A-M30LS15-M1-B1 E2A-M30LS15-M1-B2
E2A-M30LS15-M1-B3
NPN E2A-M30LS15-M1-C1 E2A-M30LS15-M1-C2
E2A-M30LS15-M1-C3
M8
connector
(3-pin) Brass*3 44 (58) PNP E2A-M30KS15-M5-B1 E2A-M30KS15-M5-B2 n.a.
NPN E2A-M30KS15-M5-C1 E2A-M30KS15-M5-C2 n.a.
66 (80) PNP E2A-M30LS15-M5-B1 E2A-M30LS15-M5-B2 n.a.
NPN E2A-M30LS15-M5-C1 E2A-M30LS15-M5-C2 n.a.
M8
connector
(4-pin) Brass*3 44 (58) PNP E2A-M30KS15-M3-B1 E2A-M30KS15-M3-B2
n.a.
NPN E2A-M30KS15-M3-C1 E2A-M30KS15-M3-C2
n.a.
66 (80) PNP E2A-M30LS15-M3-B1 E2A-M30LS15-M3-B2
n.a.
NPN E2A-M30LS15-M3-C1 E2A-M30LS15-M3-C2
n.a.
Non-
shiel-
ded
20.0 mm Pre-wired Brass*3
44 (64)
(See
note.)
PNP
E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M E2A-M30KN20-WP-B3 2M
NPN
E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M E2A-M30KN20-WP-C3 2M
30.0 mm 66 (86) PNP
E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2M E2A-M30LN30-WP-B3 2M
NPN
E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M E2A-M30LN30-WP-C3 2M
20.0 mm M12
connector Brass*3
44 (58)
(See
note.)
PNP E2A-M30KN20-M1-B1 E2A-M30KN20-M1-B2
E2A-M30KN20-M1-B3
NPN E2A-M30KN20-M1-C1 E2A-M30KN20-M1-C2
E2A-M30KN20-M1-C3
30.0 mm 66 (80) PNP E2A-M30LN30-M1-B1 E2A-M30LN30-M1-B2
E2A-M30LN30-M1-B3
NPN E2A-M30LN30-M1-C1 E2A-M30LN30-M1-C2
E2A-M30LN30-M1-C3
20.0 mm M8
connector
(3-pin) Brass*3
44 (58)
(See
note.)
PNP E2A-M30KN20-M5-B1 E2A-M30KN20-M5-B2
n.a.
NPN E2A-M30KN20-M5-C1 E2A-M30KN20-M5-C2
n.a.
30.0 mm 66 (80) PNP E2A-M30LN30-M5-B1 E2A-M30LN30-M5-B2
n.a.
NPN E2A-M30LN30-M5-C1 E2A-M30LN30-M5-C2
n.a.
20.0 mm M8
connector
(4-pin) Brass*3
44 (58)
(See
note.)
PNP E2A-M30KN20-M3-B1 E2A-M30KN20-M3-B2
n.a.
NPN E2A-M30KN20-M3-C1 E2A-M30KN20-M3-C2
n.a.
30.0 mm 66 (80) PNP E2A-M30LN30-M3-B1 E2A-M30LN30-M3-B2
n.a.
NPN E2A-M30LN30-M3-C1 E2A-M30LN30-M3-C2
n.a.
Size Sensing
distance Connec-
tion Body
material
Thread
length
(overall
length)
Output
confi-
guration Operation mode NO Operation mode NC Operation mode NO + NC
4Inductive Sensors
Connectivity
The E2A sensors are available with the f ollowing connectors and cable materials:
Pre-wired models
Standard cable lengths are 2m and 5m.
For other cable lengths please contact your OMRON
representative.
Standard cable material: PVC (dia 4mm) -WP
Other available cable materials and sizes:
- PVC (dia 6mm) -WS
- PUR/PVC – PUR jacket (dia 4mm) -WA
- PUR/PVC – PUR jacket (dia 6mm) -WB
- PVC robotic cable (dia 4mm) -WR
Pre-wired models with cable end connectors
All pre-wired models can be fitted with cable and connectors .
Standard cable end connectors:
- M12 M1J
- M8 (4 pin) M3J
- M8 (3 pin) M5J
Other cable end connectors are available on request.
Connector models
Standard connectors: M12, M8 (4 or 3 pin) -M1, -M3, -M5
5E2A
Model Number Legend
Example: E2A-M12LS04-M1-B1 Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
E2A-S08KN04-WP-B1 5M Standard, M8 stainless steel, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO,
cable length=5 m
1. Basic name
E2A
2. Sensing technology
Blank: Standard double distance
3. Housing shape and material
M: Cylindrical, metric threaded, brass
S: Cylindrical, metric threaded, stainless steel
4. Housing size
08: 8 mm
12: 12 mm
18: 18 mm
30: 30 mm
5. Barrel length
K: Standard length
L: Long body
6. Shield
S: Shielded
N: Non-shielded
7. Sensing distance
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
8. Kind of connection
WP: pre-wired, PVC, dia 4mm (standard)
WS: pre-wired, PVC, dia 6mm
WR: pre-wired, PVC, robotic cable, dia 4mm
WA: pre-wired, PUR/PVC (PUR jacket), dia 4mm
WB: pre-wired, PUR/PVC (PUR jacket), dia 6mm
M1: M12 connector (4 pin) *
M3: M8 connector (4 pin)
M5: M8 connector (3 pin)
M1J pre-wired with M12 cable end connector (4 pin)
M3J pre-wired with M8 cable end connector (4 pin)
M5J pre-wired with M8 cable end connector (3 pin)
9. Power source and output
B: DC, 3-wire, PNP open collector
C: DC, 3-wire, NPN open collector
D: DC, 2-wire
E: DC, 3-wire, NPN voltage output
F: DC, 3-wire, PNP voltage output
10.Operation mode
1: Normally open (NO)
2: Normally closed (NC)
3: Antivalent (NO+NC)
11.Specials (e.g., cable material, oscillating frequency)
12.Cable length
Blank: Connector type
Numeral: Cable length
Note: *In case of DC 2-wire models the M12 connector identifier is '- M1G'
2 3 4 5 6 7 8 9 10 111 12
E2A@-@@@@@-@-@@-@@
6Inductive Sensors
Specifications
DC 3-wire Models / DC 4-wire (NO+NC)
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between 40°C and 25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and Canada: use class 2 circuit only.
4. -B3/ -C3 NO+NC models are available in M12, M18 and M30 housings with M12 connectors, pre-wired and with cable end connectors.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-S08@S02-@@-B1
E2A-S08@S02-@@-C1 E2A-S08@N04-@@-B1
E2A-S08@N04-@@-C1
E2A-M12
@
S04-
@@
-B
@
E2A-M12
@
S04-
@@
-C
@
E2A-S12
@
S04-
@@
-B
@
E2A-S12
@
S04-
@@
-C
@
E2A-M12
@
N08-
@@
-B
@
E2A-M12
@
N08-
@@
-C
@
E2A-S12
@
N08-
@@
-B
@
E2A-S12
@
N08-
@@
-C
@
Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm 12×12×1 mm 24×24×1 mm
Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.) 200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts. (See note 4.)
Protection circuit Power source circuit reverse polarity protection,
Surge suppressor, Short-circuit protection Output reverse polarity protection, Power source
circuit reverse polarity protection, Surge suppres-
sor, Short-circuit protection
Ambient air temperature Operating: 40°C to 70°C, Storage: 40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.) ±10% max. of sensing distance at 23°C within temperature range of 25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of 40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See note 3.) IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 65 g Approx. 85 g
Connector model M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g Approx. 35 g
Material
Case Stainless steel Brass-nickel plated or stainless steel
Sensing surface PBT
Cable Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless
steel for steel models
7E2A
DC 3-wire Models / DC 4-wire (NO+NC)
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between 40°C and 25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded Non-shielded
Item
E2A-M18@S08-@@-B@
E2A-M18@S08-@@-C@
E2A-S18@S08-@@-B@
E2A-S18@S08-@@-C@
E2A-M18@N16-@@-B@
E2A-M18@N16-@@-C@
E2A-S18@N16-@@-B@
E2A-S18@N16-@@-C@
E2A-M30@S15-@@-B@
E2A-M30@S15-@@-C@
E2A-S30@S15-@@-B@
E2A-S30@S15-@@-C@
E2A-M30KN20-@@-B@
E2A-M30KN20-@@-C@
E2A-S30KN20-@@-B@
E2A-S30KN20-@@-C@
E2A-M30LN30-@@-B@
E2A-M30LN30-@@-C@
E2A-S30LN30-@@-B@
E2A-S30LN30-@@-C@
Sensing distance 8 mm±10% 16 mm±10% 15 mm±10% 20 mm±10% 30 mm±10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37) 24×24×1 mm 48×48×1 mm 45×45×1 mm 60×60×1 mm 90×90×1 mm
Response frequency
(See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz 100 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption
(DC 3-wire) 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.) 200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object
approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts.
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operating: 40°C to 70°C, Storage: 40°C to 85°C (with no icing or condensation)
Temperature influence
(See note 2.) ±10% max. of sensing distance at 23°C within temperature range of 25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of 40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See
note 3.) IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors.
Weight
(pak-
kaged)
Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g
Connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g
Material
Case Brass-nickel plated or stainless steel
Sensing surface PBT
Cable Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut brass-nickel plated for brass models stainless steel for steel models
8Inductive Sensors
DC 2-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between 40°C and 25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item E2A-S08@S02-D@E2A-S08@N04-D@
E2A-M12
@
S04-D
@
E2A-S12
@
S04-D
@
E2A-M12
@
N08-D
@
E2A-S12
@
N08-D
@
Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target 8×8×1 mm 12×12×1 mm 12×12×1 mm 24×24×1 mm
Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Leakage current 0.8 mA max.
Output type DC 2 wire type
Control
output
Load current
(See note 2.) 3 to 100 mA
Residual voltage 3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator (see timing chart) NO type: Operation indicator (Yellow), Setting indicator (Red)
NC type: Operation indicator (Yellow)
Operation mode -D1 models: NO
-D2 models: NC
Protection circuit Surget suppressor, Short circuit protection
Ambient temperature Operating: 40°C to 70°C, Storage: 40°C to 85°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of 25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of 40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See note 3.) IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 65 g Approx. 85 g
Connector model M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g Approx. 35 g
Material
Case Stainless steel Brass-nickel plated or stainless steel
Sensing surface PBT
Cable Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless
steel for steel models
9E2A
DC 2-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-M18@S08-D@
E2A-S18@S08-D@ E2A-M18@N16-D@
E2A-S18@N16-D@
E2A-M30
@
S15-D
@
E2A-S30
@
S15-D
@
E2A-M30
@
N30-D
@
E2A-M30
@
N20-D
@
E2A-S30
@
N30-D
@
E2A-S30
@
N20-D
@
Sensing distance 8 mm ± 10% 16 mm ± 10% 15 mm ± 10% Short body: 20 m ± 10%
Long body: 30 m± 10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm Short body: 0 to 16 mm
Long body: 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target 24x24x1 mm 48x48x1 mm 45x45x1 mm
Short body: 60x60x1 mm
Long body: 90x90x1mm
Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Leakage current 0.8 mA max.
Output type DC 2 wire type
Control
output
Load current
(See note 2.) 3 to 100 mA
Residual voltage 3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator (see timing chart) NO type: Operation indicator (Yellow), Setting indicator (Red)
NC type: Operation indicator (Yellow)
Operation mode -D1 models: NO
-D2 models: NC
Protection circuit Surget suppressor, Short circuit protection
Ambient temperature Operating: 40°C to 70°C, Storage: 40°C to 85°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of 25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of 40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See note 3.) IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 160 g Approx. 280 g short body: 280 g
long body: 370 g
Connector model Approx. 70 g Approx. 200 g short body: 200 g
long body: 260 g
Material
Case Brass-nickel plated or stainless steel
Sensing surface PBT
Cable Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut brass-nickel plated for brass models stainless steel for steel models
10 Inductive Sensors
Engineering Data
Operating Range (Typical)
Influence of Sensing Object Size and Materials
Shielded Models
Distance Y (mm)
X
Y
18
16
14
12
10
8
6
4
2
0
30 20 10 0 10 20 30
E2A-M30@S15
Sensing distance X (mm)
E2A-M18@S08
E2A-M12@S04
E2A-S08@S02/
E2A-M08@S02
Shielded Models
X
Y
35
30
25
20
15
10
5
0
50 40 30 20 10 0 10 20 30 40 50
Non-shielded Models
Distance Y (mm)
Sensing distance X (mm)
E2A-M30LN30
E2A-M18@N16
E2A-M12@N08
E2A-S08
@
N04/
E2A-M08
@
N04
E2A-M30KN20
0 5 10 15 20 25
Side length of sensing object d (mm)
Iron
@d
t = 1 mm
X
0.5
1.0
1.5
2.0
2.5 5.0
4.0
3.0
2.0
1.0
0
@d
t = 1 mm
X
5101520253035 0
1.0
2.0
3.0
4.0
5.0
7.0
8.0
6.0
10 20 30 40 50 60
@d
t = 1 mm
X
0
4
8
12
16
20
10 20 30 40 50 60 70 80
@d
t = 1 mm
X
Sensing distance X (mm)
Stainless steel (SUS303)
Aluminum
Side length of sensing object d (mm)
Brass
Iron
Sensing distance X (mm)
Stainless steel
(SUS303)
Aluminum
Copper
Side length of sensing object d (mm)
Brass
Iron
Sensing distance X (mm)
Copper
Stainless steel (SUS303)
Aluminum
E2A-S08@S02 E2A-M12@S04/ E2A-S12@S04 E2A-M18@S08/E2A-S18@S08
E2A-M30@S15/ E2A-S30@S15
Side length of sensing object d (mm)
Sensing distance X (mm)
Iron
Stainless steel (SUS303)
Brass
Copper
Brass
Copper
Aluminum
11E2A
Non-shielded Models
5.0
4.0
3.0
2.0
1.0
0 10 20 30 40 50
@d
t = 1 mm
X
10
8
6
4
2
0
@d
t = 1 mm
X
10 20 30 40 50
20
16
12
8
4
0
@d
t = 1 mm
X
20 40 60 80
0
5
10
15
20
25
35
30
20 40 60 80 100
@d
t = 1 mm
X
E2A-S08@N04
Side length of sensing object d (mm)
Sensing distance X (mm)
Iron
Brass
Copper
Stainless steel (SUS303)
E2A-M12@N08/E2A-S12@N08
Side length of sensing object d (mm)
Sensing distance X (mm)
Iron
Brass
Aluminum
Stainless steel (SUS303)
Copper
E2A-M18@N16/E2A-S18@N16
Side length of sensing object d (mm)
Sensing distance X (mm)
Iron
Copper
Brass
Aluminum
E2A-M30LN30/E2A-S30LN30
Side length of sensing object d (mm)
Sensing distance X (mm)
Iron
Copper
Brass
Aluminum
Stainless steel (SUS303)
Stainless steel (SUS303)
Aluminum
Side length of sensing object d (mm)
Sensing distance X (mm)
25
20
15
10
5
0 20 40 60 80 100
t = 1 mm
@d
X
Copper
Brass
Iron
Aluminum
Stainless steel (SUS303)
E2A-M30KN20/E2A-S30KN20
12 Inductive Sensors
Operation
DC 3-wire models
PNP Output
Operation mode Model Timing chart Output circuit
NO E2A-@-@-B1
NC E2A-@-@-B2
NO + NC E2A-@-@-B3
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
243
14
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 connector
(3 pin)
Pin Arrangement
M8 Connector
(4 pin)
Pin Arrangement
(See note 2.)
Note 2: Pin 2 of the M12 connector and M8 connector is not
used.
Proximity
Sensor
main
circuits
1243
(%) 100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
24
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
3
14
M8 connector
(3 pin)
Pin Arrangement
Note 2: Pin 4 of the M12 connector and M8 connector is not
used.
Proximity
Sensor
main
circuits
(M8 connector: )
M8 Connector
(4 pin)
Pin Arrangement
(See note 2.)
1243
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
NO output
NC output
ON
OFF
Brown +V
3
1
24
M12 Connector
Pin Arrangement
Black NO output
White
Load
Proximity
Sensor
main
circuits
Blue
2
3
Load
NC output
4
1
0 V
13E2A
DC 3-wire models
NPN Output
Operation mode Model Timing chart Output circuit
NO E2A-@-@-C1
NC E2A-@-@-C2
NO + NC E2A-@-@-C3
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
Note 2: Pin 2 of the M12 connector and M8 connector is not
used.
Proximity
Sensor
main
circuits
3
1
24
M12 Connector
Pin Arrangement
(See note 2.)
3
14
M8 connector
(3 pin)
Pin Arrangement
M8 Connector
(4 pin)
Pin Arrangement
(See note 2.)
1243
(%) 100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
Note 2: Pin 4 of the M12 connector and M8 connector is not
used.
Proximity
Sensor
main
circuits
(M8 connector: )
3
1
24
M12 Connector
Pin Arrangement
(See note 2.)
3
14
M8 connector
(3 pin)
Pin Arrangement
M8 Connector
(4 pin)
Pin Arrangement
(See note 2.)
1243
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
NO output
NC output
ON
OFF
Brown +V
3
1
24
M12 Connector
Pin Arrangement
Black
White
Proximity
Sensor
main
circuits
Blue
2
3
Load
NC output
4
1
0 V
Load
NO output
14 Inductive Sensors
DC 2-wire models
Output Circuit Diagrams (Ope ration)
Operation mode Model Timing chart Output circuit
NO E2A-@-D1
NC E2A-@-D2
Sensing
object
(%) 100 80 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
ON
OFF
Yellow indicator
Red indicator
Control output
Load Brown
Blue
+V
0 V
Load can be connected to +V or 0V side.
3
1
24
M12 Connector
Pin Arrangement
(%) 100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Load Brown
Blue
+V
0 V
Load can be connected to +V or 0V side.
3
1
24
M12 Connector
Pin Arrangement
15E2A
Dimensions
Note:All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded) Pre-wired Models (Non-shielded)
3 5
27 40
13
M8×1(See note 1.)
E2A-S08KS02-WP-@@
3
40
5
27
13 6
M8×1
5.8 dia.
E2A-S08KN04-WP-@@
4
50.3
7
34
17
M12×1Two, clamping nuts
E2A-M12KS04-WP-@@/E2A-S12KS04-WP-@ E2A-M12KN08-WP-@@/E2A-S12KN08-WP-@
47
34 50.3
17 7
9.2 dia.
M12×1
M18×1
410
39 59.5
24
E2A-M18KS08-WP-@@/E2A-S18KS08-WP-@ E2A-M18KN16-WP-@@/E2A-S18KN16-WP-@
10
39 59.5
24 10 4
15.1 dia.
M18×1
E2A-M30KS15-WP-@@/E2A-S30KS15-WP-@
510
64.5
44
36
M30×1.5
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer
Indicator (See note 2.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.) M30×1.5
(See note 1.)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)
26.4 dia.
36 5
44
15 10
64.5
E2A-M30KN20-WP-@@/E2A-S30KN20-WP-@
2. Operation indicator (yellow)
3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer
16 Inductive Sensors
M12×1
17
72.3
56
7
4
M12×1
17
72.3
56
747
9.2 dia.
M18×1
24
81.5
61 10
410
61 81.5
24 10 4
15.1 dia.
M18×1
510
86.5
66
36
M30×1.5 M30×1.5
26.4 dia.
10
566 86.5
36
(See note 1.) (See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
E2A-M12LS04-WP-@@/E2A-S12LS04-WP-@
E2A-M18LS08-WP-@@/E2A-S18LS08-WP-@
E2A-M12LN08-WP-@@/E2A-S12LN08-WP-@
E2A-M18LN16-WP-@@/E2A-S18LN16-WP-@
E2A-M30LN30-WP-@@/E2A-S30LN30-WP-@
E2A-M30LS15-WP-@@/E2A-S30LS15-WP-@
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Two, clamping nuts Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Mounting Hole Cutout Dimensions
F
External diameter
of Proximity Sensor Dimension F (mm)
M18
M30
M8
M12
8.5 dia.+0.5
0
12.5 dia.+0.5
0
18.5 dia.+0.5
0
30.5 dia.+0.5
0
3 5
49 62
13
M8×1(See note 1.)
E2A-S08LS02-WP-@@
3
62
5
49
13 6
M8×1
5.8 dia.
E2A-S08LN04-WP-@@
(See note 1.)
Two, clamping nuts Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
Two, clamping nuts Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm
2
; insulator diameter: 1.3 mm); standard length: 2 m
2.
Operation indicator (yellow)
17E2A
M12 Connector Models (Shielded) M 12 Connector Models (Non-shielded)
E2A-S08KS02-M1-@@
E2A-M12KS04-M1-@@/E2A-S12KS04-M1-@ E2A-M12KN08-M1-@@/E2A-S12KN08-M1-@
27 43
35
13
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08KN04-M1-@@
6 dia.
35
27 43
6
13
M8×1
M12×1
E2A-M18KS08-M1-@@/E2A-S18KS08-M1-@ E2A-M18KN16-M1-@@/E2A-S18KN16-M1-@
7
434 48
17
M12×1
M12×1
9.4 dia.
4
34
48
77
17
M12×1
M12×1
10
24 439 53
M18×1
M12×124 10
4
39 53
10
15.3 dia.
M18×1
M12×1
E2A-M30KS15-M1-@@/E2A-S30KS15-M1-@
44
5
58
36 10
M30×1.5
M12×1
Note 1: Operation indicator (yellow LED, 4×90°)
Note 2: for NO+NC (-B3 / -C3) models the total
length is 4 mm longer
Note 1: Operation indicator (yellow LED, 4×90°)
Note 2: for NO+NC (-B3 / -C3) models the total
length is 4 mm longer
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
26.6 dia.
M12×1
Note: Operation indicator (yellow LED, 4×90°)
515
36 44 10
58
M30×1.5 Indicator (See note.)
Two, clamping nuts
E2A-M30KN20-M1-@@/E2A-S30KN20-M1-@
18 Inductive Sensors
M8 Connector Models (Shielded) M8 Connector Models (Non-sh i elded)
Note: Please contact your OMRON sales representative for dimension drawings not listed here.
7
456 70
17
M12×1
M12×1
9.2 dia.
4
56 70
77
17
M12×1
M12×1
10
24 461 75
M18×1
M12×1
24 10
4
61 75
10
15.1 dia.
M18×1
M12×1
66
5
80
36 10
M30×1.5
M12×1
10
5
15 66 80
36
26.6 dia.
M30×1.5
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M12LS04-M1-@@
E2A-S12LS04-M1-@
E2A-M18LS08-M1-@@
E2A-S18LS08-M1-@
E2A-M30LS15-M1-@@
E2A-S30LS15-M1-@
E2A-M12LN08-M1-@@
E2A-S12LN08-M1-@
E2A-M18LN16-M1-@@
E2A-S18LN16-M1-@
E2A-M30LN30-M1-@@
E2A-S30LN30-M1-@
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts Indicator (See note.)
E2A-S08LS02-M1-@@
49 65
35
13
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LN04-M1-@@
6 dia.
35
49 65
6
13
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
Two, clamping nuts Indicator (See note.) Indicator (See note.)
M8×1
M8×1
E2A-S08KS02-M5-@@/E2A-S08KS02-M3-@ E2A-S08KN04-M5-@@/E2A-S08KN04-M3-@
5.8 dia.
3
6
13 5
27 39
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°)Note: Operation indicator (yellow LED, 4×90°)
3
13 27 5
39
Two, clamping nuts Two, clamping nuts
M8×1
M8×1
E2A-S08LS02-M5-@@/E2A-S08LS02-M3-@ E2A-S08LN04-M5-@@/E2A-S08LN04-M3-@
5.8 dia.
3
6
13 5
49 61
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°)Note: Operation indicator (yellow LED, 4×90°)
3
13 49 5
61
19E2A
Precautions
Safety Precautions
Power Supply
Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the E2A may be damaged.
The E2A’s shor t-circuit protection function will be valid if the polar ity
of the supply voltage imposed is correct and within the rated voltage
range.
Wiring
Be sure to wire the E2A and load correctly, otherwise it may be dam-
aged.
Connection with No Load
Be sure to inser t loads when wiring. Ma ke sure to connect a proper
load to the E2A in operation, otherwise it may damage internal ele-
ments.
Do not expose the product to flammable or explo-
sive gases.
Do not disassemble, repair, or modify the product.
Correct Us e
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms (160ms for
NO+NC -B3 / -C3 types) after power is supplied. If power supplies
are connected to the Proximity Sensor and load respectiv ely, be sure
to supply power to the Proximity Sensor before supplying power to
the load.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clear-
ances given in the following table are maintained.
(Unit: mm)
Note 1. In the case of using the supplied nuts.
If true flash mounting is necessary, apply a free zone of
1.5 mm.
2. In the case of using the supplied nuts.
If true flush mounting is necessary, apply a free zone of
4 mm.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power sup-
ply has an insulated transf ormer. Do not use a DC power supply with
an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
(Unit: mm)
Type
Dimension
M8 M12 M18 M30
Short
barrel Long
barrel
Shielded
l00
0
(See note 1.) 0
(See note 2.)
m 4.5 12 24 45
d --- --- 27 45
D001.5 4
n121827 45
Non-
shielded
l1215223040
m 8 20 48 70 90
d 24 40 70 90 120
D121522 3040
n 24 40 70 90 120
l
mn
mDd dia.
l
Type
Dimension
M8 M12 M18 M30
Short
barrel Long
barrel
Shielded A 203060110
B 15203570
Non-shiel-
ded A 80 120 200 300 300
B 60 100 120 200 300
20 Inductive Sensors
Wiring
High-tensi on Lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal cond uit to pre-
vent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Maintenance and Inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, lo oseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environ-
mental conditions.
5. Check for proper lighting of indicators (for models with a set indi-
cator.)
Never disassemble or repair the Sensor.
Environment
Water Resistivity
The Proximity Sensors are tested intensiv ely on w ater resistance, but
in order to ensure maximum performance and life expectancy avoid
immersion in water and provide protection from rain or snow.
Operating Environment
Ensure storage and operation of the Proximity Sensor within the
given specifications.
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
<SUITABILITY FOR USE>
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the
customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
<CHANGE IN SPECIFICATIONS>
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON
representative at any time to confirm actual specifications of purchased product.
Type Torque
M8 Stainless steel type 9 Nm
Brass type 4 Nm
M12 30 Nm
M18 70 Nm
M30 180 Nm
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D03E-EN-02A