Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para -
me ters, test conditions and
processing information only
to be used together with the
'Definitions' section in the
cat -
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
1
SCHRACK
Interface Plug-in Relay XT
n1 pole 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts
nDC- or AC coil, sensitive coil 400 mW
nReinforced insulation, protection class II (VDE 0700)
n4 kV / 8 mm coil-contact
nManual test tab, optionally lockable1)
nVersion with mechanical and/or electrical indicator
optionally available
nSuitable for use in Tyco standard RT sockets
nRecycleable packaging
Applications
Panel boards, mechanical engineering
F0289-B
Approvals
VREG.-Nr. B758, ZE214025
Technical data of approved types on request
Contact data 1-pole 2-pole
Contact configuration 1 CO 2 CO
Contact set single contact
Type of interruption micro disconnection
Rated voltage / max. switching voltage AC 240 / 400 VAC
Rated current 16 A 8 A
Limiting continuous current 16 A 8 A, UL: 10 A
Maximum breaking capacity AC 4000 VA 2000 VA
Limiting making capacity,max 4 s, df 10% 30 A 15 A
Contact material AgNi 90/10
Rated frequency of operation with / without load 6 / 600 min-1
Operate- / release time DC coil max 8 / 6 ms max 10 / 5 ms
Bounce time DC coil, NO / NC contact max 4 / 6 ms max 4 / 9 ms
Contact ratings
Type ContactLoad Ambient Cycles
temp. [°C]
IEC 61810
XT3 CO 16 A, 250 VAC, cosϕ=1 70°C 30x103
XT3 NO 16 A, 250 VAC, cosϕ=1 70°C 50x103
XT4 CO 8 A, 250 VAC, cosϕ=1 70°C 50x103
XT4 DC-coil NO 8 A, 250 VAC, cosϕ=1 70°C 100x103
UL 508
XT3 CO 16 A, 250 VAC, general purpose 70°C 30x103
XT4 CO 10 A, 250 VAC, general purpose 70°C 20x103
XT4 CO 8 A, 250 VAC, general purpose 70°C 30x103
Coil data
Rated coil voltage range DC coil 6...110 VDC
AC coil 24...230 VAC
Operative range to IEC 61810 2
Coil insulation system according UL1446 class F
1) Locking function description
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go
straight into the locked position.
Delivery status is with testing possibility only, to reach locking position please remove the locking
plastic pip according drawing.