Specification
AC/DC Open Frame
Active PFC - Meets EN61000-3-2, -3
Up to 90% Efficiency
Zero Voltage Switching Technology
Small size 3.00” x 5.00” x 1.28”
100 W Convection Cooled
Single & Multiple Outputs
130 Watts
JPS130 Series
Input
AC Input Voltage 85-264 VAC
Input Frequency 47-63 Hz
DC Input Voltage 127-370 VDC
Inrush Current 30 A max at 115 VAC,
60 A max at 230 VAC
Input Current 2 A max at 115 VAC,
1 A max at 230 VAC
Power Factor 0.9 typical
Output
Output Voltage See Table
Set Point Accuracy V1 ±1%, V2 & V3 ±5%,
measured at 60% load
Output Power 130 Watts
Minimum Load No minimum load required (Note 1)
Line Regulation ±0.5%, for nominal line ±10%
Load Regulation ±1%, ±5% for all secondar y outputs
on multiple output models (Note 2)
Tolerance ±1%
Ripple & Noise ±1% max peak-peak (Note 3)
Transient Response 4% max deviation, 500 µs recovery
time for a 25% load change
Temperature 0.05%/°C
Coefficient
Hold Up Time 16 ms typical
Remote Sense Single output models only,
compensates for 0.5 V lead drop
Overvoltage 115% to 140%,
Protection recycle input to reset
Overcurrent 120% - 150%, foldback
Protection with auto recovery
General
Efficiency (Typical) Up to 90%, nominal line full load
Power Density 6.7 W/in3
MTBF 100,000 hrs min to MIL-HDBK-217F
Isolation Voltage 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Size 3.00” x 5.00” x 1.28”,
(1.35” for multi output)
Weight 300 g
Switching Frequency 120 KHz fixed ±10% for both active
PFC and main switch
Environmental
Operating 0 °C to +70 °C See Derating Curve
Temperature Full power to +50 °C
Cooling 130 W with 18 CFM airflow
100 W with convection cooling
Storage -40 °C to +85 °C
Temperature
EMC & Safety
Safety Approvals UL1950, CSA C22.2 No 234
EN60950, CE Mark LVD
Emissions EN55022 Class B and FCC 20780
Level B conducted
Immunity Meets EN61000-3-2, -3,
(EN61000-4-2,-3, -4, -6, -8)
Performance criteria A
Intelligent Design Quality Product
XPiQ inc.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
11
Mechanical Detail
Notes:
1. Dimensions in inches (mm). Tolerance is ± 1mm.
2. AC input connector (TB1): Molex 5277-02A or equivalent.
3. DC output connector (TB2): Molex 5273 or equivalent except
Model JPS130PS03 which has a 6 position terminal block.
4. TB3 : Molex 5045-02A or equivalent.
Single output units - TB3 is remote sense.
Triple output units - TB3 is 12 V, 450 mA fan output.
TB2 Models
Pins PS05 PS03, 12, 15, 24, 48 PT31 PT30
1 +V +V +5 V +3.3 V
2 +V +V +5 V +3.3 V
3 +V +V +5 V +3.3 V
4 +V RET RET RET
5 RET RET RET RET
6 RET RET RET RET
7 RET N/A RET RET
8 RET N/A +12 V +5 V
9 N/A N/A -12 V +5 V
10 N/A N/A N/A +12 V
1. 20% minimum load required on V1 to maintain stated regulation for auxiliary rails.
2. Load regulation of auxilary rails is defined over the range of 60% of rated output ±40%.
3. Ripple & noise is measured by using 15 MHz bandwidth, each output terminated with a 0.47 µF capacitor and a 47 µF electrolytic
capacitor at rated load and nominal line.
Notes
*Total height of unit 1.28” (32.4 mm) for single output models, 1.35” (34.4 mm) for triple output models.
A
B
C
A
B
C
D
D
OUTPUT VOLTAGE & CURRENT RATINGS JPS130
Output Output Output Current Ripple & Noise Model
Power Voltage Convection Cooled Max 18 CFM Pk-Pk(3) Number
100 W 3.3 V 25.0 A 30.0 A 50 mV JPS130PS03
130 W +5.0 V 20.0 A 26.0 A 50 mV JPS130PS05
130 W +12.0 V 9.0 A 10.8 A 120 mV JPS130PS12
130 W +15.0 V 7.0 A 8.7 A 120 mV JPS130PS15
130 W +24.0 V 4.5 A 5.4 A 200 mV JPS130PS24
130 W +48.0 V 2.3 A 2.7 A 200 mV JPS130PS48
+5.0 V (1) 11.5 A 15.0 A 50 mV
130 W +12.0 V (2) 3.0 A 4.0 A 100 mV JPS130PT31
-12.0 V (2) 0.5 A 0.5 A 100 mV
+3.3 V (1) 10.0 A 15.0 A 50 mV
130 W +5.0 V (2) 8.0 A 15.0 A 50 mV JPS130PT30
+12.0 V (2) 0.5 A 0.5 A 100 mV
Derating Curve
JPS130 with 18 CFM fan.
JPS130PS12, PS15, PS24, PS48 with
convection cooling & JPS130PS03 with 18 CFM fan.
JPS130PS05, PT30, PT31 with convection cooling.
JPS130PS03 with convection cooling.
12
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com