TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
1/13
Version: G14
TO
-
92
SOT
-
23
-
8
SOT
-
89
General Description
The TS78L00 Series of positive voltage Regulators are inexpensive, easy-to-use devices suitable for a multitude
of applications that require a regulated supply of up to 100mA. Like their higher power TS7800 and TS78M00
Series cousins, these regulators feature internal current limiting and thermal shutdown making them remarkably
rugged. No external components are required with the TS78L00 devices in many applications.
These devices offer a substantial performance advantage over the traditional zener diode-resistor combination,
as output impedance and quiescent current are substantially reduced.
Features
Output Voltage Range 3.3 to 24V
Output current up to 100mA
No external components required
Internal thermal overload protection
Internal short-circuit current limiting
Output transistor safe-area compensation
Output voltage offered in 4% tolerance
Standard Application Circuit
A common ground is required between the input and the
output voltages. The input voltage must remain typically
2.0V above the output voltage even during the low point
on the Input ripple voltage.
XX = these two digits of the type number indicate
voltage.
* = Cin is required if regulator is located an appreciable
distance from power supply filter.
** = Co is not needed for stability; however, it does
improve transient response.
Ordering Information
Part No. Package
Packing
TS78LxxCT B0 TO-92 1kpcs / Bulk
TS78LxxCT A3 TO-92 2kpcs/ Ammo
TS78LxxACY RM
SOT-89 1kpcs / 7” Reel
TS78LxxCS RL SOP-8 2.5kpcs / 13” Reel
TS78LxxCX RF SOT-23 3kpcs / 7” Reel
Note: Refer to detail ordering information table.
Absolute Maximum Ratings
(T
A
= 25
o
C unless otherwise noted)
Parameter Symbol Limit Unit
DC Input Voltage
TS78L03
V
IN
30
V TS78L05 35
TS78L24 40
Power Dissipation P
D
Internal Limited W
Operating Junction Temperature Range T
J
0 ~ +150
o
C
Storage Temperature Range T
STG
-65~+150
o
C
Pin
Definition
:
1. Output
2. Ground
3. Input
Pin
Definition
:
1. Output 8. Input
2. Ground 7. Ground
3. Ground 6. Ground
4. N/C 5. N/C
Pin
Definition
:
1. Output
2. Input
3. Ground
Pin
Definition
:
1. Output
2. Ground
3. Input
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
2/13
Version: G14
Thermal Performance
Parameter Symbol Limit Unit
Thermal Resistance - Junction to Case
TO-92
R
ӨJC
--
o
C/W
SOT-23 120
SOT-89 15
SOP-8 20
Thermal Resistance - Junction to Ambient
TO-92
R
ӨJA
230
o
C/W
SOT-23 330
SOT-89 55
SOP-8 55
Note: Considering 6 cm
2
of copper board heat-sink
TS78L03 Electrical Characteristics
(V
IN
=8.3V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max Unit
Output voltage V
OUT
T
J
=25
o
C 3.173
3.3 3.432
V
5.8VV
IN
20V,
5mAI
OUT
100mA 3.142
3.3 3.465
Line Regulation REG
LINE
T
J
=25
o
C
5.8VVin20V
I
OUT
=40mA -- 50 150 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mA I
OUT
100mA -- 15 60
5mAI
OUT
40mA -- 5 30
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 3 6 mA
Quiescent Current Change I
Q
5.8VVin20V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 40 -- µV
Ripple Rejection Ratio RR f=120Hz, 5.8VVin20V 41 49 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 2 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -0.2 -- mV/
o
C
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible, and thermal effects must be taken into account separately.
This specification applies only for DC power dissipation permitted by absolute maximum ratings.
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
3/13
Version: G14
TS78L05 Electrical Characteristics
(V
IN
=10V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max Unit
Output voltage V
OUT
T
J
=25
o
C 4.80 5 5.20 V
7.5VVin20V,
5mAI
OUT
100mA 4.75 5 5.25
Line Regulation REG
LINE
T
J
=25
o
C
7.5VVin20V
I
OUT
=100mA -- 50 150 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mAI
OUT
100mA -- 20 60
5mAI
OUT
40mA -- 10 30
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 3 6 mA
Quiescent Current Change I
Q
7.5VVin20V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 40 -- µV
Ripple Rejection Ratio RR f=120Hz, 7.5VVin20V 41 49 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 1.7 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -0.65
-- mV/
o
C
TS78L09 Electrical Characteristics
(V
IN
=15V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max
Unit
Output voltage V
OUT
T
J
=25
o
C 8.65 9 9.36 V
11.5VVin23V,
5mAI
OUT
100mA 8.57 9 9.45
Line Regulation REG
LINE
T
J
=25
o
C
11.5VVin23V
I
OUT
=40mA -- 90 180 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mAI
OUT
100mA -- 30 90
5mAI
OUT
40mA -- 15 45
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 3 6 mA
Quiescent Current Change I
Q
11.5VVin23V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 60 -- µV
Ripple Rejection Ratio RR f=120Hz, 11.5VVin23V 37 57 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 1.7 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -0.9 -- mV/
o
C
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible, and thermal effects must be taken into account separately.
This specification applies only for DC power dissipation permitted by absolute maximum ratings.
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
4/13
Version: G14
TS78L12 Electrical Characteristics
(V
IN
=19V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max Unit
Output voltage V
OUT
T
J
=25
o
C 11.53
12 12.48
V
14.5VVin27V,
5mAI
OUT
100mA 11.42
12 12.60
Line Regulation REG
LINE
T
J
=25
o
C
14.5VVin27V
I
OUT
=40mA -- 120 240 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mAI
OUT
100mA -- 40 120
5mAI
OUT
40mA -- 20 60
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 3 6.5 mA
Quiescent Current Change I
Q
14.5VVin27V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 80 -- µV
Ripple Rejection Ratio RR f=120Hz, 14.5VVin27V 37 42 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 1.7 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -1.0 -- mV/
o
C
TS78L15 Electrical Characteristics
(V
IN
=23V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max Unit
Output voltage V
OUT
T
J
=25
o
C 14.42
15 15.60
V
17.5VVin30V,
5mAI
OUT
100mA 14.28
15 15.75
Line Regulation REG
LINE
T
J
=25
o
C
17.5VVin30V
I
OUT
=40mA -- 150 300 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mAI
OUT
100mA -- 50 150
5mAI
OUT
40mA -- 25 75
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 3 6.6 mA
Quiescent Current Change I
Q
17.5VVin30V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 90 -- µV
Ripple Rejection Ratio RR f=120Hz, 17.5VVin30V 34 39 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 1.7 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -1.3 -- mV/
o
C
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible, and thermal effects must be taken into account separately.
This specification applies only for DC power dissipation permitted by absolute maximum ratings.
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
5/13
Version: G14
TS78L24 Electrical Characteristics
(V
IN
=33V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF; unless otherwise specified.)
Parameter Symbol Test Condition Min Typ Max Unit
Output voltage V
OUT
T
J
=25
o
C 23.07
24 24.96
V
27VVin38V,
5mAI
OUT
100mA 22.85
24 25.20
Line Regulation REG
LINE
T
J
=25
o
C
27Vin38V
I
OUT
=40mA -- 200 400 mV
Load Regulation REG
LOAD
T
J
=25
o
C
5mAI
OUT
100mA -- 80 240
5mAI
OUT
40mA -- 40 120
Quiescent Current I
Q
I
OUT
=0, T
J
=25
o
C -- 4 7 mA
Quiescent Current Change I
Q
27VVin38V -- -- 1.5
5mAI
OUT
40mA -- -- 0.1
Output Noise Voltage V
N
10Hzf100KHz, T
J
=25
o
C -- 200 -- µV
Ripple Rejection Ratio RR f=120Hz, 27VVin38V 31 45 -- dB
Voltage Drop V
DROP
I
OUT
=100mA, T
J
=25
o
C -- 1.7 -- V
Peak Output Current Io peak T
J
=25
o
C -- 0.15 -- A
Temperature Coefficient of
Output Voltage V
OUT
/ T
J
I
OUT
=5mA, 0
o
CT
J
150
o
C -- -2.0 -- mV/
o
C
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible, and thermal effects must be taken into account separately.
This specification applies only for DC power dissipation permitted by absolute maximum ratings.
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
6/13
Version: G14
Application Information
Design Considerations
The TS78L00 Series of fixed voltage regulators are designed with Thermal Overload Protection that shuts down
the circuit when subjected to an excessive power overload condition. Internal Short Circuit protection Limits the
maximum current the circuit will pass.
In many low current applications, compensation capacitors are not required. However, it is recommended that the
regulator input be bypassed with a capacitor if the regulator is connected to the power supply filter with long wire
lengths, or if the output load capacitance is large. The input bypass capacitor should be selected to provide good
high-frequency characteristics to insure stable operation under all load conditions. A 0.33µF or larger tantalum,
mylar, or other capacitor having low internal impedance at high frequencies should be chosen. The bypass
capacitor should be mounted with the shortest possible leads directly across the regulators input terminals. Good
construction techniques should be used to minimize ground loops and lead resistance drops since the regulator
has no external sense lead. Bypassing the output is also recommended.
FIGURE 1 – Current Regulator
The TS78L00 regulators can also be used as a current
source when connected as above. In order to minimize
dissipation the TS78L05 is chosen in this application.
Resistor R determines the current as follows:
I
IB
=3.8mA over lined and load changes
For example, a 100mA current source would require R to
be a 50. 1/2W resistor and the output voltage compliance
would be the input voltage less 7V.
FIGURE 2 – ±
±±
±15V Tracking Voltage Regulator
FIGURE 3 – ±
±±
±15V Tracking Voltage Regulator
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
7/13
Version: G14
Ordering information
Voltage TO-92 SOT-89 SOP-8 SOT-23
3.3V TS78L03CT B0
TS78L03CT A3 TS78L03ACY RM TS78L03CS RL TS78L03CX RF
5V TS78L05CT B0
TS78L05CT A3 TS78L05ACY RM TS78L05CS RL TS78L05CX RF
9V TS78L09CT B0
TS78L09CT A3 TS78L09ACY RM TS78L09CS RL TS78L09CX RF
12V TS78L12CT B0
TS78L12CT A3 TS78L12ACY RM TS78L12CS RL
15V TS78L15CT B0
TS78L15CT A3 TS78L15ACY RM TS78L15CS RL
24V TS78L24CS RL
Packing code information
Packing B0: 1kpcs / Bulk
A3: 2kpcs / Ammo 1kpcs / 7" Reel 2.5kpcs / 13" Reel 3kpcs / 7"Reel
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
8/13
Version: G14
TO-92 Mechanical Drawing
Unit: Millimeters
Marking Diagram
XX
= Output Voltage
(03=3.3V, 05=5V, 09=9V, 12=12V, 15=15V)
Y
= Year Code
M
= Month Code
(A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep,
J=Oct, K=Nov, L=Dec)
L
= Lot Code
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
9/13
Version: G14
SOT-89 Mechanical Drawing
Unit: Millimeters
Marking Diagram
XX
= Output Voltage
(03=3.3V, 05=5V, 09=9V, 12=12V, 15=15V)
Y
= Year Code
M
= Month Code
(A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep,
J=Oct, K=Nov, L=Dec)
L
= Lot Code
A
= TS78LxxACY
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
10/13
Version: G14
SOP-8 Mechanical Drawing
Unit: Millimeters
Marking Diagram
XX
= Output Voltage
(03=3.3V, 05=5V, 09=9V, 12=12V, 15=15V, 24=24V)
Y
= Year Code
M
= Month Code
(A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep,
J=Oct, K=Nov, L=Dec)
L
= Lot Code
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
11/13
Version: G14
SOT-23 Mechanical Drawing
Unit: Millimeters
Marking Diagram
L
3
= Device Voltage Code
(L3=3.3V, L5=5V, L9=9V)
Y
= Year Code
M
= Month Code
(A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep,
J=Oct, K=Nov, L=Dec)
L
= Lot Code
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
12/13
Version: G14
TO-92 Ammo Pack Mechanical Drawing
Tape Dimension
Item Description Symbol Dimension
Base of Package to Lead Bend b 3.0 (typ.)
Component Height Ha 23.57 (typ.)
Lead Clinch Height H0 16.0 ±0.5
Component Base Height H1 19.0 ±0.5
Component Top to Lead Bend H2 8.0 (max)
Component Alignment (side / side) Pd 1.02 (max)
Component Alignment (front / back) Hd 0.79 (max)
Feed Hole Pitch P0 12.7 ±0.3
Hole Center to Component Center P1 6.25 ±0.4
Lead Spread F1 2.5 ±0.3
Lead Thickness d 0.46 (typ.)
Cut Lead Length L 10.9 (max)
Taped Lead Length L1 5.31 (typ.)
Taped Lead Thickness t 0.81 ±0.2
Carrier Tape Thickness t1 0.5 ±0.2
Carrier Tape Width W 18.0 ±0.5
Hold – down Tape Width W0 0.5 ±0.2
Hold – down Tape position W1 9.0 ±0.7
Feed Hole Position W2 6.0 ±0.2
Sprocket Hole Diameter D0 4.0 ±0.2
Lead Spring Out S 0.1 (max)
Note: All dimensions are in millimeter.
TS78L00 Series
3-Terminal 100mA Positive Voltage Regulator
13/13
Version: G14
Notice
Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf,
assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, to
any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of
sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty,
relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose,
merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify TSC for any damages resulting from such improper use or sale.