The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling. RoHS Lead Free and Lead-Solder-Exempt Products are Available High Power Density Industry-Standard 3" x 5" Footprint Power Factor Correction (PFC) Meets EN61000-3-2 Main Output Remote Sense Power Good signals CE Marked to Low Voltage Directive Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5 MTBF In Excess of 1Million Hours based upon field data Optional Remote On/Off with 5V Standby Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125-2003DG which need only 10 CFM for full power. Optional remote on/off with standby power is also provided (see Options). The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark. North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series MPB125-2003DG 2 MPB125-2005G 3, 4 MPB125-2012 3, 4, 5 MPB125-2015 3, 4, 5 MPB125-2024G 3, 4, 5 MPB125-2048 3, 4, 5 MPB125-3000 +3.3V MAXIMUM OUTPUT CURRENT (AMPS), 130 LFM 30A 3% 1% 3.20V to 3.40V +12V 0.5A 5% 1% 11.80V to 12.60V OUTPUT VOLTAGE [V] MODEL 6 MPB125-4250 6 MPB125-4350 6 TOTAL REGULATION [%] RIPPLE & NOISE 1 % pk-pk REGULATION RANGE +5V 25A 3% 1% 4.85V to 5.15V +12V 0.5A 5% 1% 10.80V to 12.60V +12V 10.5A 3% 1% 11.64V to 12.36V 12V 0.5A 5% 1% 11.40V to 12.60V +15V 8.3A 3% 1% 14.54V to 15.45V 12V 0.5A 5% 1% 11.40V to 12.60V +24V 5.2A 3% 1% 23.28V to 24.72V 12V 0.5A 5% 1% 11.40V to 12.60V +48V 2.6A 3% 1% 46.56V to 49.44V 12V 0.5A 5% 1% 11.40V to 12.60V +5V 16.5A 4% 1% 8 4.85V to 5.25V +12V 5A/9Apk 5% 1% 11.40V to 12.60V -12V 0.5A 5% 1% -11.40V to -12.60V +2.5V 12A 7 3% 2% 2.42V to 2.58V +5V 15A 7 4% 1% 8 4.85V to 5.25V +12V 5A/9Apk 5% 1% 11.40V to 12.60V -12V 0.5A 5% 1% -11.40V to -12.60V +3.3V 10A 7 3% 1.5% 3.20V to 3.40V 4% 8 +5V 15A 7 1% 4.85V to 5.25V +12V 5A/9Apk 5% 1% 11.40V to 12.60V -12V 0.5A 5% 1% -11.40V to -12.60V NOTES: 1 2 3 4 5 6 7 8 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. For MPB125-2003DG, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a minimum airflow of 5 CFM. Maximum forced-air output power is 125 watts with 5 CFM airflow. Maximum convection output power is 70 watts. V2 is isolated from V1 and can be used as a negative or positive output. V output's peak load maximum duration is 30 seconds. Average current must not exceed 5A. Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details. For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak. OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exempt 1 No RoHS suffix character required. RoHS compliant for all 6 substances Add "G" as the last character of the part number. Current Share (Option D) Provided on dual-output models. Up to 4 units can be connected in parallel. There are some limits for parallel operation. See MPB125 Applications Note. N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation. An external diode is required on MPB125-2003 and MPB125-2005 models for redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or -2005D which have an internal isolation diode 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series Remote On/Off Standby Output (Option R) Remote On/Off is a TTL-compatible signal. A logic "high" or open circuit turns the unit on. Reverse inhibit logic can be achieved by changing the position of the J6 connector. A logic "low" inhibits all outputs except the 5V standby. At remote off, the Power Good signal will warn the host equipment 2 milliseconds before the main output goes out of regulation. The rating of the standby output is +5V @ 0.2 Amps. Total regulation is 5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz bandwidth. NOTE: The addition of Option "R" increases the supply width from 3.0 to 3.8 inches. Consult factory for availability 1 The solder exemption refers to all the restricted materials except lead in solder. PARAMETER CONDITIONS/DESCRIPTION Input Voltage- AC Continuous input range Input Frequency MAX UNITS 90 264 VAC AC Input 47 63 Hz Brownout Protection Lowest AC input voltage that regulation is maintained with full rated loads 90 VAC Hold-up Time Over full AC input voltage range at full rated load 17 ms Input Current 90 VAC at full rated load 1.8 Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A. 110 VAC: Internally limited by thermistor, one cycle, 25 C 220 VAC: 23 46 Input Protection Inrush Surge Current Power Factor Circuitry Active PFC meets requirements of EN61000-3-2 Operating Frequency Switching frequency of main transformer. MIN ARMS APK 45 PARAMETER CONDITIONS/DESCRIPTION Efficiency Full Load, 230VAC. Varies with distribution of loads among outputs. (Minimum efficiency reflects that of MPB125-2003D and -2005D models.) Minimum Loads NOM V1 + V2 + V3 for MPB125-4XXX and -3000. V1 for MPB125-2XXX for full regulation on V2. All models operate at no load without any damage and meet all specs on V1 above 0 amps. kHz MIN NOM MAX UNITS 73 80 85 % 5 5 Watts Ripple and Noise Full load, 20 MHz bandwidth See Model Selection Chart Output Power (Note 1) At 5 CFM forced-air cooling. See Application Note #M3 for details. Convection: Consult Factory 125 Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on 10 Regulation Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load Transient Response Maximum deviation due to a 25% load change with unit at 75% load. All models except MPB125-2005G and -2005D Model MPB125-2005G and -2005D Turn-on Delay Time required for initial output voltage stabilization 0.2 1.5 Time required for output voltage to rise from 10% to 90% except for MPB125-2005G and -2005D MPB125-2005G and MPB125-2005D 0.2 20 Turn-on Rise Time 1 100 Watts % See Model Selection Chart 3 5 % Sec ms 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series PARAMETER Overvoltage Protection Overload Protection Remote Sense (Note 2) Dual Output Models Remote Sense (Note 2) Triple & Quad Output Models Power Good Signal Power Supply OK Signal Thermal Shutdown Isolation Diode CONDITIONS/DESCRIPTION MIN V1 of dual and triple output models; V1 & V2 outputs of 4-output models. MPB125-2003 and -2003D MPB125-4250 (V1) MPB125-4350 (V1) 5V Output of MPB125-2005 and -2005D, MPB125-3000, or MPB125-4X50 MPB125-2012 MPB125-2015 MPB125-2024 MPB125-2048 Fully protected against output short circuit or overload. Automatic recovery upon removal of overload condition. MPB125-2003, -2003D -2005, and -2005D latch OFF if overload occurs on V1 which requires an AC reset. Total (+sense and -sense) voltage compensation for cable losses on dual output models. On models MPB125-4350 remote sense is provided on the 2.5 and 3.3V outputs, respectively. MPB125-3000 does not have positive remote sense. Total voltage compensation for cable losses on +Sense. Total voltage compensation for cable losses on -Sense. AC/DC indicator - This signal indicates the status of the AC input or DC outputs. When there is sufficient AC voltage and the outputs are operating normally, an open collector signal is provided. Turn-On delay time from application of AC: Warning time before outputs go out of regulation: Warning time before outputs deviate 10% from the nominal value: Sync Current Pull-up Voltage Provided on dual-output models. Open collector signal intended to drive an LED. Closed collector occurs when the Power Good Signal is in its open collector state. Sync Current Pull-up Voltage Protected against overtemperature conditions. Unit recovers when overtemperature condition is removed. Internal isolation diode is provided on V1 for all dual-output models except the MPB125-2003 and MPB125-2005. Specify MPB125-2003D or MPB125-2005D, respectively, if an internal isolation diode is required for these models. 3.67 3.20 3.76 5.74 13.5 17.0 26.9 57.6 50 5 15 NOM MAX 4.80 4.00 4.80 7.00 16.5 19.0 31.1 62.4 UNITS VDC 500 mV 200 100 mV 500 ms 20 30 mA V 20 30 mA V NOTES: 1) For MPB125-2003, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a minimum airflow of 5 CFM. 2) -Sense must be connected to output common or load common for proper power supply operation. 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series PARAMETER CONDITIONS/DESCRIPTION Agency Approvals Approved to latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1. MIN Dielectric Withstand Voltage Input to Chassis Input to Output (Tested by manufacturer only) Electromagnetic Interference NOM MAX UNITS 2121 4242 VDC VDC EN55022 Conducted B Class ESD Susceptibility Per EN61000-4-2, Level 4 8 kV Flicker Per EN61000-3-3 Radiated Susceptibility Per EN61000-4-3 EFT/Burst Per EN61000-4-4 Input Transient Protection Per EN61000-4-5, Level 3, 2 kV (Line-to-Ground) minimum, 1 kV (Line-to-Line) minimum. RF Immunity Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sine wave) 3 V/m Magnetic Fields Per EN61000-4-8 1 A/m Voltage Dips Per EN61000-4-11 Insulation Resistance Input to output. 10 M Leakage Current Per EN60950 (264 VAC) PARAMETER Altitude Operating Temperature 3 1 CONDITIONS/DESCRIPTION MIN Operating Non-Operating Derate linearly from 50 to 70C to 50% power at 70C. At 100% load: MPB125 models will operate at -20C, but will not meet all specifications. Storage Temperature Forced-Air Cooling 1) Forced-air cooling of 5 CFM is required for full output power except for MPB125-2003 and -2003D. Air velocity is measured with power supply mounted on 0.375" (9.5mm) standoffs. Airflow direction is from the input section to the output section. See Application Note #M3 for details. Temperature Coefficient Included in total regulation of outputs Relative Humidity Non-Condensing Shock Vibration V/m kV NOM 1.0 mA MAX UNITS 10K 50K ASL Feet 0 50 C -40 85 C 95 %RH 5 Operating: 11 3ms, 3 axes, Half Sine Non-operating: 11 3ms, 3 axes, Half Sine Operating: Random vibration, 5-500 Hz, 10 minutes each axis. Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis 15 40 2.4 6.0 Gpk GRMS NOTES: 1 For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a minimum airflow of 5 CFM. 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series Figure 1 - Mechanical Drawing (-2012, -2015, -2024, & -2048 Models) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 J4 Housing Pins Housing Pins Housing Pins Housing Pins MPB125-2012, -2015, -2024, -2048 09-50-8031 08-52-0113 09-50-8061 08-52-0113 22-01-3067 08-50-0114 22-01-3027 08-50-0114 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series Figure 2 - Mechanical Drawing (-2003, -2003D, -2005, and -2005D Models) 0.19" PRINTED CIRCUIT BOARD (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 J4 Housing Pins Housing Pins Housing Pins Housing Pins MPB125-2005 09-50-8031 08-52-0113 09-50-8103 08-52-0113 22-01-3057 08-50-0114 22-01-3027 08-50-0114 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series Figure 3 - Mechanical Drawing (-3000, -4250, & -4350 Models) J1 - AC INPUT CONNECTOR 0.19" PRINTED CIRCUIT BOARD (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 Housing Pins Housing Pins Housing Pins MPB125-3000, -4250, -4350 09-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series MPB125 Series "R" Option Figure 4 - Mechanical Drawing (-2012R, -2015R, -2024R, & -2048R Models) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 J4 J5 Housing Pins Housing Pins Housing Pins Housing Pins Housing Pins MPB125-2012, -2015, -2024, -2048 09-50-8033 08-52-0113 09-50-8063 08-52-0113 22-01-3067 08-50-0114 22-01-3027 08-50-0114 22-01-3037 08-50-0114 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA MPB125 Multiple-Output AC-DC Series MPB125 Series "R" Option Mechanical Drawing (-3000R, -4250R, & -4350R Models) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. MPB125-3000R, -4250R, -4350R J1 J2 J3 J5 Housing Pins Housing Pins Housing Pins Housing Pins 09-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114 22-01-3037 08-50-0114 NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00597_AA