MPB125 Multiple-Output AC-DC Series
© 2015 Bel Power Solutions, Inc.
866.513.2839
tech.support@psbel.com
BCD.00597_AA
Remote On/Off Standby Output
Remote On/Off is a TTL-compatible signal. A logic “high” or open circuit turns the unit on. Reverse
inhibit logic can be achieved by changing the position of the J6 connector. A logic “low” inhibits all
outputs except the 5V standby. At remote off, the Power Good signal will warn the host equipment 2
milliseconds before the main output goes out of regulation. The rating of the standby output is +5V @
0.2 Amps. Total regulation is ±5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz
bandwidth.
NOTE: The addition of Option “R” increases the supply width from 3.0 to 3.8 inches. Consult factory
for availability
1 The solder exemption refers to all the restricted materials except lead in solder.
Lowest AC input voltage that regulation is maintained with full rated loads
Over full AC input voltage range at full rated load
90 VAC at full rated load
Non-user serviceable internally located AC input line fuse, 250 VAC,
3.15A.
Internally limited by thermistor, one cycle, 25° C
Active PFC meets requirements of EN61000-3-2
Switching frequency of main transformer.
Full Load, 230VAC. Varies with distribution of loads among outputs.
(Minimum efficiency reflects that of MPB125-2003D and -2005D models.)
V1 + V2 + V3 for MPB125-4XXX and -3000.
V1 for MPB125-2XXX for full regulation on V2.
All models operate at no load without any damage and meet all specs on
V1 above 0 amps.
Full load, 20 MHz bandwidth
See Model Selection Chart
At 5 CFM forced-air cooling. See Application Note #M3 for details.
Convection: Consult Factory
Output voltage overshoot/undershoot at turn-on
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to
100% load
See Model Selection Chart
Maximum deviation due to a 25% load change with unit at 75% load.
All models except MPB125-2005G and -2005D
Model MPB125-2005G and -2005D
Time required for initial output voltage stabilization
Time required for output voltage to rise from 10% to 90% except for
MPB125-2005G and -2005D
MPB125-2005G and MPB125-2005D