MUR1505
THRU
MUR1560
15 Amp Super Fast
Glass Passivated
Rectifier
Features
Maximum Ratings
Operating Temperature: - 55°C to +175°C
Storage Temperature: - 55°C to +175°C
Microsemi
Catalog
Number
Device
Marking Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MUR1505 MUR1505 50V 35V 50V
MUR1510 MUR1510 100V 70V 100V
MUR1520 MUR1520 200V 140V 200V
MUR1540 MUR1540 400V 280V 400V
MUR1560 MUR1560 600V 420V 600V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 15.0A TC = 120 °C
Peak Forward Surge
Current IFSM 150A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 10uA
1000uA TJ = 25°C
TJ = 100°C
MCC
www. mccsemi.com
Glass passivated chip
Superfast switching time for hight efficiency
Low reverse leakage current
High surge capacity
1505-1520
1540-1560
A
B
C
K
J
I
G
F
E
D
N
M
L
H
PIN 1
PIN 2 CASE
PIN
12
 INCHES MM
     
A .560 .625 14.22 15.88
B .380 .420 9.65 10.67
C .100 .135 2.54 3.43
D .230 .270 5.84 6.86
E .380 .420 9.65 10.67
F ------ .250 ------ 6.35
G .500 .580 12.70 14.73
H .190 .210 4.83 5.33
I .020 .045 0.51 1.14
J .012 .025 0.30 0.64
K .139 .161 3.53 4.09
L .140 .190 3.56 4.83
M .045 .055 1.14 1.40
N .080 .115 2.03 2.92

TO-220AC
TJ = 25°C
1505-1520
1540-1560
1.25V
2.0 V
VF IFM = 15A
Trr
IF=0.5A, Ir=1.0A,
Irr=0.25A
Typical Junction
Capacitance CJ 160pF Measured at
1.0MHz, VR=4.0V
35ns
60ns
Maximum Reverse
Recovery Time
50 to 600 Volts
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
Version: 2 2002/12/30
MUR1505 thru MUR1560
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 150 175
0
0
2
4
6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
10
12
15
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2
1.8
.4 .6 1.0
1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
2.2
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
2
0 140
40
80 100
120
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
TJ=25°C
www.mccsemi.com
MCC
1505-1520
1 100
4
0
25
50
75
8
Figure 4
Maximum Non-Repetitive Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
00
100
150
200
1540-1560
Version: 2 2002/12/30