SR502 THRU SR5100
CURRENT 5.0Amperes
VOLTAGE 20 to 100 Volts
Maximum Ratings and Electrical Characteristics
Notes:
(1) Pulse test: 300μS pulse width, 1% duty cycle
(2) Thermal resistance from junction to lead vrtical P.C.B. mounted, 0.375"(9.5mm) lead length
(3) Measured 1MHz and reverse voltage of 4.0 volts
(Ratings at 25 ambient temperature unless otherwise specified, single phase, half wave, resistive or inductive
load. For capacitive load, derate by 20%)
Features
Mechanical Data
· Plastic Package has Underwriters Laboratory
Flammability Classification 94V-0
· Metal silicon junction, majority carrier conduction
· Guard ring for overvoltage protection
· Low power loss, high efficiency
· High current capability, Low forward voltage drop
· High surge capability
· For use in low voltage, high frequency inverters,
free wheeling, and polarity protection applications
· High temperature soldering guaranteed :
250/10 seconds at terminals,
0.375" (9.5mm) lead length, 5lbs. (2.3Kg) tension
· Case : JEDEC DO-201AD molded plastic body
· Terminals : Plated axial leads, solderable per
MIL-STD-750, Method 2026
· Polarity : Color band denotes cathode end
· Mounting Position : Any
· Weight : 0.041 ounce, 1.15 gram
Symbols SR502 SR504 Units
Maximum repetitive peak reverse voltage V
RRM
20 30 40 Volts
Maximum RMS voltage V
RMS
0.55 0.70
Maximum DC blocking voltage V
DC
Volts
Maximum average forward rectified current
0.375"(9.5mm) lead length(see Fig. 1) I(
AV
) 5.0
Peak forward surge current 8.3ms single half
sine-wave superimposed on rated load
(JEDEC mothod at rated T
L
)
150.0 Amps
Amps
Maximum instantaneous forward voltage
at 5.0A (Note 1) V
F
2.5
Volts
T
A
=25
50
Maximum instantaneous reverse
current at rated DC blocking
voltage (Note1) T
A
=100
500
mA
Typical thermal resistnce (Note 2) 25.0 /W
Operating junction temperature range -65 to +125
I
R
I
FSM
Rθ
JA
T
J
Volts
SR503
C
J
14 21 28
20 30 40
P
FTypical junction capacitance (Note 3)
Storage temperature range
T
STG
-65 to +150
-65 to +150
0.85
SR505 SR508
50 60 80
SR506
35 42 56
50 60 80
SR5100
100
70
100
Rθ
JL
8.0
25
400
Dimensions in inches and (millimeters)
DO-201AD
1.0(25.4)
MIN.
1.0(25.4)
MIN.
0.375(9.5)
0.285(7.2)
0.042(1.1)
0.037(0.9)
DIA.
0.210(5.3)
0.188(4.8)
DIA.
FIG.1-FORWARD CURRENT DERATING CURVE
AVERAGE FORWARD CURRENT
AMPERES
LEAD TEMPERATURE (
)
0 15012010080604020
RESISTIVE OR INDUCTIVE LOAD
0.375" (9.5MM) LEAD LENGTH
0
4.0
3.0
2.0
1.0
5.0
INSTANTANEOUS FORWARD CURRENT (AMPERES)
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
PULSE WIDTH=300
1% DUTY CYCLE
0 1.41.21.00.80.60.40.2 1.6
0.01
50
10
1
0.1
FIG.3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
TJ=25
TJ=125
TJ=150
──󰼿SR502-SR504
- - - SR505-SR5100
──󰼿SR502-SR504
- - - SR505-SR5100
REVERSE VOLTAGE. VOLTS
JUNCTION CAPACITANCE(pF)
0.1 100101
100
4000
1000
FIG.5-TYPICAL JUNCTION CAPACITANCE
TJ=25
f=1.0MHz
Vsig=50mVp-p
──󰼿SR502-SR504
- - - SR505-SR5100
FIG.6-TYPICAL TRANSIENT THERMAL IMPEDANCE
T, PULSE DURATION, sec.
TRANSIENT THERMAL IMPEDANCE,/ W
0.01 1001010.1
1
100
10
0.1
FIG.4-TYPICAL REVERSE CHARACTERISTICS
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
INSTANTANEOUS REVERSE CURRENT MILL (AMPERES)
0 10080604020
TJ=75
TJ=25
TJ=125
0.001
10
1
0.1
0.01
20
──󰼿SR502-SR504
- - - SR505-SR5100
FIG.2-MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE
CURRENT(AMPERES)
NUMBER OF CYCLES AT 60Hz
1 10010
T
J
=T
J
MAX
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
0
100
75
50
25
125
150
RATINGS AND CHARACTERISTIC CURVES SR502 THRU SR5100