Aluminum electrolytic capacitors Snap-in capacitors Series/Type: B41252 Date: December 2010 (c) EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Snap-in capacitors B41252 Standard series 105 C General-purpose grade capacitors Applications Switch-mode power supplies in industrial and entertainment electronics Features High ripple current capability RoHS-compatible Useful life of 2000 h at 105 C Construction Aluminum case, fully insulated Snap-in solder pins to hold component in place on PC-board Minus pole marking on the insulating sleeve Case with safety vent Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 20 B41252 Standard series 105 C Specifications and characteristics in brief Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance Dissipation factor (max.) (20 C, 120 Hz) 10 ... 100 V DC 1.15 VR (at room temperature) 820 ... 56000 F 20% M VR (V DC) 10 16 25 35 50 63 80 100 tan 0.45 0.35 0.30 0.20 0.20 0.15 0.12 0.12 Leakage current Ileak (20 C, after 5 minutes) Useful life 105 C; VR; IAC,R > 2000 h Vibration resistance test Shelf life Operating temperature range Characteristics at low temperature IEC climatic category Sectional specification Requirements: C/C 20% of initial value tan 2 times initial specified limit Ileak initial specified limit To IEC 60068-2-6, test Fc: Frequency range 10 Hz ... 55 Hz, displacement amplitude 0.75 mm, acceleration max. 10 g, duration 3 x 2 h. Capacitor rigidly clamped by the aluminum case After storage for 1000 h at 105 C, the capacitors shall meet the requirement of load life test after reforming process. After test: VR to be applied for 30 minutes, 24 to 48 hours before measurement. 40 C ... +105 C Max. impedance ratio at 120 Hz VR 16 V 25 V Z -25 C / Z 20 C 4 3 Z -40 C / Z 20 C 15 10 35 V 3 8 50 ... 63 V 80 V 2 2 6 5 To IEC 60068-1: 40/105/56 (40 C/+105 C/56 days damp heat test) IEC 60384-4 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 20 B41252 Standard series 105 C Dimensional drawing Snap-in terminals, length (6.0 1) mm. Also available in a shorter version with a length of (4.5 1) mm. Snap-in capacitors are also available with 3 terminals (length (4.5 1) mm). Dimensions (mm) d +1 l 2 22 25 22 30 22 35 22 40 22 45 22 50 25.4 25 25.4 30 25.4 35 25.4 40 25.4 45 25.4 50 Dimensions (mm) d +1 l 2 30 25 30 30 30 35 30 40 30 45 30 50 35 30 35 35 35 40 35 45 35 50 Approx. weight (g) Packing units (pcs.) 13.0 15.0 20.5 23.0 25.0 29.5 13.5 19.5 25.0 28.0 31.0 39.0 200 100 100 100 100 100 100 50 50 50 50 50 Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 20 Approx. weight (g) Packing units (pcs.) 24.5 25.5 32.5 39.0 43.5 55.5 43.0 50.5 52.0 65.0 70.5 100 100 50 50 50 50 80 50 50 50 50 B41252 Standard series 105 C Overview of available types VR (V DC) 10 16 25 35 50 63 80 100 22 x 25 22 x 30 25.4 x 25 Case dimensions d x l (mm) CR (F) 820 22 x 30 22 x 35 25.4 x 25 25.4 x 30 1000 x 25 22 x 30 22 x 40 25.4 x 25 25.4 x 35 30 x 25 1200 22 1500 22 x 30 22 x 35 22 x 45 25.4 x 25 25.4 x 30 25.4 x 40 30 x 30 1800 22 x 30 22 x 40 25.4 x 45 25.4 x 25 25.4 x 35 30 x 35 30 x 25 2200 22 x 35 22 x 45 25.4 x 50 25.4 x 30 25.4 x 35 30 x 40 30 x 30 35 x 30 2700 22 x 30 22 x 40 25.4 x 45 30 25.4 x 30 30 x 35 35 30 x 25 x 45 x 35 x 35 22 x 50 25.4 x 50 30 25.4 x 40 30 x 40 35 30 x 30 35 x 30 x 50 x 40 3300 22 x 25 22 3900 22 x 30 22 x 40 25.4 x 45 30 25.4 x 35 30 x 35 35 30 x 25 x 45 35 x 35 x 45 x 50 4700 22 x 25 22 x 35 22 x 45 25.4 x 50 30 25.4 x 25 25.4 x 40 30 x 40 35 30 x 30 35 x 30 x 50 35 x 40 5600 22 x 30 22 x 35 22 x 50 30 25.4 x 30 25.4 x 40 35 30 x 25 30 x 35 x 45 35 x 35 x 45 6800 22 x 30 22 x 40 25.4 x 50 30 25.4 x 35 30 x 40 35 30 x 30 35 x 30 x 50 35 x 40 x 50 8200 22 x 25 22 x 35 22 x 50 30 25.4 x 30 25.4 x 40 35 30 x 30 Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 20 x 45 35 x 35 x 45 B41252 Standard series 105 C VR (V DC) 10 16 25 35 50 63 80 Case dimensions d x l (mm) CR (F) 10000 22 x 25 22 x 30 22 x 40 25.4 x 45 30 25.4 x 25 25.4 x 35 30 x 35 35 x 50 35 x 40 12000 22 x 30 22 x 35 22 x 45 25.4 x 50 35 25.4 x 30 25.4 x 40 30 x 40 30 x 25 30 x 30 35 x 30 x 45 15000 22 x 35 22 x 40 25.4 x 45 30 25.4 x 25 25.4 x 35 30 x 35 35 30 x 30 35 x 30 x 45 35 x 35 18000 22 x 35 22 x 45 25.4 x 50 35 25.4 x 30 25.4 x 40 30 x 40 30 x 30 35 x 35 x 40 22000 22 x 40 25.4 x 45 30 25.4 x 35 30 x 35 35 30 x 25 x 45 35 x 35 x 45 27000 22 x 50 25.4 x 50 35 25.4 x 40 30 x 40 30 x 30 35 x 30 x 45 33000 25.4 x 45 30 30 x 35 35 x 45 x 35 39000 25.4 x 50 30 30 x 40 35 35 x 30 x 50 x 40 47000 30 35 x 45 35 x 35 x 45 56000 35 x 45 Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 20 x 50 x 50 100 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 10 V DC 10000 22 x 25 12000 22 x 30 15000 22 x 35 15000 25.4 x 25 18000 22 x 35 18000 25.4 x 30 22000 22 x 40 22000 25.4 x 35 22000 30 x 25 27000 22 x 50 27000 25.4 x 40 27000 30 x 30 33000 25.4 x 45 33000 30 x 35 39000 25.4 x 50 39000 30 x 40 39000 35 x 30 47000 30 x 45 47000 35 x 35 56000 35 x 45 VR = 16 V DC 8200 22 x 25 10000 22 x 30 10000 25.4 x 25 12000 22 x 35 12000 25.4 x 30 12000 30 x 25 15000 22 x 40 15000 25.4 x 35 15000 30 x 30 18000 22 x 45 18000 25.4 x 40 18000 30 x 30 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 4.99 5.70 6.51 6.33 6.90 7.15 7.71 8.00 7.77 8.92 8.90 8.72 9.80 9.66 10.58 10.51 10.26 11.39 11.20 12.63 3.80 4.34 4.95 4.81 5.25 5.44 5.86 6.09 5.92 6.79 6.77 6.63 7.46 7.35 8.05 8.00 7.81 8.66 8.52 9.61 2.17 2.48 2.83 2.75 3.00 3.11 3.35 3.48 3.38 3.88 3.87 3.79 4.26 4.20 4.60 4.57 4.46 4.95 4.87 5.49 B41252A3109M0*# B41252A3129M0*# B41252A3159M0*# B41252B3159M0*# B41252A3189M0*# B41252B3189M0*# B41252A3229M0*# B41252B3229M0*# B41252C3229M0*# B41252A3279M0*# B41252B3279M0*# B41252C3279M0*# B41252A3339M0*# B41252B3339M0*# B41252A3399M0*# B41252B3399M0*# B41252C3399M0*# B41252A3479M0*# B41252B3479M0*# B41252A3569M0*# 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 4.92 5.70 5.89 6.44 6.67 6.83 7.29 7.57 7.77 8.05 8.40 8.21 3.75 4.34 4.48 4.90 5.08 5.20 5.55 5.76 5.92 6.13 6.39 6.25 2.14 2.48 2.56 2.80 2.90 2.97 3.17 3.29 3.38 3.50 3.65 3.57 B41252A4828M0*# B41252A4109M0*# B41252B4109M0*# B41252A4129M0*# B41252B4129M0*# B41252C4129M0*# B41252A4159M0*# B41252B4159M0*# B41252C4159M0*# B41252A4189M0*# B41252B4189M0*# B41252C4189M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 7 of 20 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 16 V DC 22000 25.4 x 45 22000 30 x 35 27000 25.4 x 50 27000 30 x 40 27000 35 x 30 33000 30 x 45 33000 35 x 35 39000 30 x 50 39000 35 x 40 47000 35 x 45 VR = 25 V DC 4700 22 x 25 5600 22 x 30 6800 22 x 30 8200 22 x 35 8200 25.4 x 30 10000 22 x 40 10000 25.4 x 35 12000 22 x 45 12000 25.4 x 40 12000 30 x 30 15000 25.4 x 45 15000 30 x 35 15000 35 x 30 18000 25.4 x 50 18000 30 x 40 18000 35 x 35 22000 30 x 45 22000 35 x 35 27000 35 x 45 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 9.27 9.15 10.17 10.10 9.87 11.02 10.83 11.87 11.73 12.65 7.05 6.97 7.74 7.68 7.51 8.38 8.24 9.03 8.93 9.63 4.03 3.98 4.42 4.39 4.29 4.79 4.71 5.16 5.10 5.50 B41252A4229M0*# B41252B4229M0*# B41252A4279M0*# B41252B4279M0*# B41252C4279M0*# B41252A4339M0*# B41252B4339M0*# B41252A4399M0*# B41252B4399M0*# B41252A4479M0*# 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 3.98 4.55 4.92 5.57 5.75 6.37 6.62 7.11 7.41 7.25 8.33 8.21 8.40 9.15 9.09 9.34 10.03 9.84 11.32 3.03 3.47 3.75 4.24 4.38 4.85 5.04 5.41 5.64 5.51 6.34 6.25 6.39 6.97 6.91 7.11 7.63 7.49 8.61 1.73 1.98 2.14 2.42 2.50 2.77 2.88 3.09 3.22 3.15 3.62 3.57 3.65 3.98 3.95 4.06 4.36 4.28 4.92 B41252A5478M0*# B41252A5568M0*# B41252A5688M0*# B41252A5828M0*# B41252B5828M0*# B41252A5109M0*# B41252B5109M0*# B41252A5129M0*# B41252B5129M0*# B41252C5129M0*# B41252A5159M0*# B41252B5159M0*# B41252C5159M0*# B41252A5189M0*# B41252B5189M0*# B41252C5189M0*# B41252A5229M0*# B41252B5229M0*# B41252A5279M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 8 of 20 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 35 V DC 3300 22 x 25 3900 22 x 30 4700 22 x 35 4700 25.4 x 25 5600 22 x 35 5600 25.4 x 30 5600 30 x 25 6800 22 x 40 6800 25.4 x 35 6800 30 x 30 8200 22 x 50 8200 25.4 x 40 8200 30 x 30 10000 25.4 x 45 10000 30 x 35 12000 25.4 x 50 12000 30 x 40 12000 35 x 30 15000 30 x 45 15000 35 x 35 18000 35 x 40 22000 35 x 45 VR = 50 V DC 2700 22 x 30 3300 22 x 35 3900 22 x 40 3900 25.4 x 35 3900 30 x 25 4700 22 x 45 4700 25.4 x 40 4700 30 x 30 5600 22 x 50 5600 25.4 x 40 5600 30 x 35 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 2.90 4.32 4.92 4.81 5.27 5.45 5.59 6.00 6.23 6.42 6.95 6.95 6.79 7.89 7.77 8.69 8.63 8.44 9.64 9.48 10.40 11.39 2.21 3.29 3.75 3.66 4.01 4.15 4.25 4.57 4.74 4.88 5.29 5.29 5.16 6.00 5.92 6.62 6.56 6.42 7.33 7.21 7.91 8.66 1.26 1.88 2.14 2.09 2.29 2.37 2.43 2.61 2.71 2.79 3.02 3.02 2.95 3.43 3.38 3.78 3.75 3.67 4.19 4.12 4.52 4.95 B41252A7338M0*# B41252B7398M0*# B41252A7478M0*# B41252B7478M0*# B41252A7568M0*# B41252B7568M0*# B41252C7568M0*# B41252A7688M0*# B41252B7688M0*# B41252C7688M0*# B41252A7828M0*# B41252B7828M0*# B41252C7828M0*# B41252A7109M0*# B41252B7109M0*# B41252A7129M0*# B41252B7129M0*# B41252C7129M0*# B41252A7159M0*# B41252B7159M0*# B41252A7189M0*# B41252A7229M0*# 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 4.46 5.06 5.80 6.03 5.84 6.46 6.74 6.60 7.15 7.15 7.38 3.40 3.85 4.41 4.59 4.45 4.92 5.13 5.02 5.44 5.44 5.62 1.94 2.20 2.52 2.62 2.54 2.81 2.93 2.87 3.11 3.11 3.21 B41252A6278M0*# B41252A6338M0*# B41252A6398M0*# B41252B6398M0*# B41252C6398M0*# B41252A6478M0*# B41252B6478M0*# B41252C6478M0*# B41252A6568M0*# B41252B6568M0*# B41252C6568M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 9 of 20 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 50 V DC 6800 25.4 x 50 6800 30 x 40 6800 35 x 30 8200 30 x 45 8200 35 x 35 10000 30 x 50 10000 35 x 40 12000 35 x 45 15000 35 x 50 VR = 63 V DC 1200 22 x 25 1500 22 x 30 1500 25.4 x 25 1800 22 x 30 1800 25.4 x 25 2200 22 x 35 2200 25.4 x 30 2700 22 x 40 2700 25.4 x 30 2700 30 x 25 3300 22 x 50 3300 25.4 x 40 3300 30 x 30 3900 25.4 x 45 3900 30 x 35 4700 25.4 x 50 4700 30 x 40 4700 35 x 30 5600 30 x 45 5600 35 x 35 6800 30 x 50 6800 35 x 40 8200 35 x 45 10000 35 x 50 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 8.37 8.30 8.12 9.06 8.90 10.17 10.05 10.99 12.05 6.37 6.32 6.18 6.90 6.77 7.74 7.65 8.37 9.17 3.64 3.61 3.53 3.94 3.87 4.42 4.37 4.78 5.24 B41252A6688M0*# B41252B6688M0*# B41252C6688M0*# B41252A6828M0*# B41252B6828M0*# B41252A6109M0*# B41252B6109M0*# B41252A6129M0*# B41252A6159M0*# 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 3.15 3.45 3.54 3.77 3.89 4.28 4.42 4.99 4.90 5.01 5.82 5.82 5.70 6.62 6.53 7.36 7.29 7.13 8.07 7.96 9.02 8.92 9.71 10.90 2.40 2.63 2.70 2.87 2.96 3.26 3.36 3.80 3.73 3.82 4.43 4.43 4.34 5.04 4.97 5.60 5.55 5.43 6.14 6.06 6.86 6.79 7.39 8.30 1.37 1.50 1.54 1.64 1.69 1.86 1.92 2.17 2.13 2.18 2.53 2.53 2.48 2.88 2.84 3.20 3.17 3.10 3.51 3.46 3.92 3.88 4.22 4.74 B41252A8128M0*# B41252A8158M0*# B41252B8158M0*# B41252A8188M0*# B41252B8188M0*# B41252A8228M0*# B41252B8228M0*# B41252A8278M0*# B41252B8278M0*# B41252C8278M0*# B41252A8338M0*# B41252B8338M0*# B41252C8338M0*# B41252A8398M0*# B41252B8398M0*# B41252A8478M0*# B41252B8478M0*# B41252C8478M0*# B41252A8568M0*# B41252B8568M0*# B41252A8688M0*# B41252B8688M0*# B41252A8828M0*# B41252A8109M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 10 of 20 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 80 V DC 820 22 x 25 1000 22 x 30 1000 25.4 x 25 1200 22 x 30 1200 25.4 x 25 1500 22 x 35 1500 25.4 x 30 1800 22 x 40 1800 25.4 x 35 1800 30 x 25 2200 22 x 45 2200 25.4 x 35 2200 30 x 30 2700 25.4 x 45 2700 30 x 35 3300 25.4 x 50 3300 30 x 40 3300 35 x 30 3900 30 x 45 3900 35 x 35 4700 30 x 50 4700 35 x 40 5600 35 x 45 6800 35 x 50 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 3.15 3.73 3.84 3.84 3.96 4.55 4.72 5.24 5.45 5.29 5.77 5.73 5.89 6.97 6.88 7.66 7.59 7.43 8.63 8.49 9.43 9.34 10.21 11.27 2.40 2.84 2.92 2.92 3.01 3.47 3.59 3.99 4.15 4.03 4.39 4.36 4.48 5.30 5.23 5.83 5.78 5.65 6.56 6.46 7.18 7.11 7.77 8.58 1.37 1.62 1.67 1.67 1.72 1.98 2.05 2.28 2.37 2.30 2.51 2.49 2.56 3.03 2.99 3.33 3.30 3.23 3.75 3.69 4.10 4.06 4.44 4.90 B41252A0827M0*# B41252A0108M0*# B41252B0108M0*# B41252A0128M0*# B41252B0128M0*# B41252A0158M0*# B41252B0158M0*# B41252A0188M0*# B41252B0188M0*# B41252C0188M0*# B41252A0228M0*# B41252B0228M0*# B41252C0228M0*# B41252A0278M0*# B41252B0278M0*# B41252A0338M0*# B41252B0338M0*# B41252C0338M0*# B41252A0398M0*# B41252B0398M0*# B41252A0478M0*# B41252B0478M0*# B41252A0568M0*# B41252A0688M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 11 of 20 B41252 Standard series 105 C Technical data and ordering codes CR 120 Hz 20 C F Case dimensions dxl mm VR = 100 V DC 820 22 x 30 820 25.4 x 25 1000 22 x 35 1000 25.4 x 30 1200 22 x 40 1200 25.4 x 35 1200 30 x 25 1500 22 x 45 1500 25.4 x 40 1500 30 x 30 1800 25.4 x 45 1800 30 x 35 2200 25.4 x 50 2200 30 x 40 2200 35 x 30 2700 30 x 45 2700 35 x 35 3300 30 x 50 3300 35 x 40 3900 35 x 45 4700 35 x 50 tan max 120 Hz 20 C IAC,max 120 Hz 60 C A IAC,max 120 Hz 85 C A IAC,R 120 Hz 105 C A Ordering code (composition see below) 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 3.36 3.47 3.93 4.07 4.28 4.46 4.32 5.01 5.24 5.13 6.00 5.91 6.56 6.51 6.35 7.52 7.41 8.26 8.17 9.27 10.12 2.56 2.64 2.99 3.10 3.26 3.40 3.29 3.82 3.99 3.90 4.57 4.50 4.99 4.95 4.83 5.72 5.64 6.28 6.21 7.05 7.70 1.46 1.51 1.71 1.77 1.86 1.94 1.88 2.18 2.28 2.23 2.61 2.57 2.85 2.83 2.76 3.27 3.22 3.59 3.55 4.03 4.40 B41252A9827M0*# B41252B9827M0*# B41252A9108M0*# B41252B9108M0*# B41252A9128M0*# B41252B9128M0*# B41252C9128M0*# B41252A9158M0*# B41252B9158M0*# B41252C9158M0*# B41252A9188M0*# B41252B9188M0*# B41252A9228M0*# B41252B9228M0*# B41252C9228M0*# B41252A9278M0*# B41252B9278M0*# B41252A9338M0*# B41252B9338M0*# B41252A9398M0*# B41252A9478M0*# Composition of ordering code * = Insulation feature 0 = PVC insulation 6 = PET insulation Please read Cautions and warnings and Important notes at the end of this document. #= Terminal style 0 = snap-in standard terminals (6.0 1 mm) 2 = snap-in 3 terminals (4.5 1 mm) 7 = snap-in short terminals (4.5 1 mm) Page 12 of 20 B41252 Standard series 105 C Useful life depending on ambient temperature TA under ripple current operating conditions1) Frequency factor of permissible ripple current IAC versus frequency f Frequency characteristics of ESR Typical behavior 1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs. Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 20 B41252 Standard series 105 C Impedance Z versus frequency f Typical behavior at 20 C Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 20 B41252 Standard series 105 C Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling aluminum electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water. Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 20 B41252 Standard series 105 C Product safety The table below summarizes the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Polarity Make sure that polar capacitors are connected with the right polarity. Reverse voltage Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperature. Upper category temperature Maintenance Mounting position of screwterminal capacitors Mounting of single-ended capacitors Robustness of terminals Soldering Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down. Reference chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance" 11.1. "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering" Please read Cautions and warnings and Important notes at the end of this document. Page 16 of 20 B41252 Standard series 105 C Topic Soldering, cleaning agents Passive flammability Active flammability Safety information Reference chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves Please read Cautions and warnings and Important notes at the end of this document. Page 17 of 20 Reference chapter "Capacitors with screw terminals" "Screw terminals accessories" B41252 Standard series 105 C Symbols and terms Symbol English German C CR CS CS,T Cf d dmax ESL ESR ESRf Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) Kapazitat Nennkapazitat Serienkapazitat Serienkapazitat bei Temperatur T Kapazitat bei Frequenz f Gehausedurchmesser, Nennma Maximaler Gehausedurchmesser Eigeninduktivitat Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T T TA TC TB t t tb Please read Cautions and warnings and Important notes at the end of this document. Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulassiger Wechselstrom Nennwechselstrom Nennwechselstromstrom fur Bodenkuhlung Reststrom Betriebsreststrom Gehauselange, Nennma Maximale Gehauselange (ohne Anschlusse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehausetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit) Page 18 of 20 B41252 Standard series 105 C Symbol V VF Vop VR VS XC XL Z ZT tan 0 r English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 f German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitatszahl Kreisfrequenz; 2 f Note All dimensions are given in mm. Please read Cautions and warnings and Important notes at the end of this document. Page 19 of 20 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 20 of 20