AVX Wire-to-Wire Connectors
www.avx.com
Version 16.4
Table of Contents
NOTICE: Specifications are subject to change without notice. Contact your nearest AVX Sales Office for the latest specifications. All statements, information
and data given herein are believed to be accurate and reliable, but are presented without guarantee, warranty, or responsibility of any kind, expressed or
implied. Statements or suggestions concerning possible use of our products are made without representation or warranty that any such use is free of patent
infringement and are not recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures
may not be required. Specifications are typical and may not apply to all applications.
THRU-WIRE CONNECTORS 18-26 AWG
00-9286 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
1 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
REDUCED THRU-WIRE CONNECTOR 18-26 AWG
9686-200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-16
1 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Wire Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
JUNCTION BOX CONNECTORS 18-26 AWG
00-9286. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-20
4 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
REDUCED JUNCTION BOX CONNECTORS 18-26 AWG
9686-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-25
4 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Wire Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
WIRE INSERTION/REMOVAL PROCESS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
ADHESIVE MOUNTING TAPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
CONNECT
INTER
1
CONNECT
INTER
2
Poke-Home Thru-Wire: WTW
00-9286
Wire-to-Wire connectors have been used in the industrial market for years with traditional
2-Piece (plug and socket) connector systems which require crimp and poke wire
terminations to connect electrical or electronic components. In the general wiring market
(2-3 wires) there are a number of connector styles available, however, they are limited in
sizes, expanded wire gauges and the ability to reuse them when repair or replacement
is needed. Based on the existing success of “Poke-Home” wire-to-board connectors,
AVX has developed a new family of wire-to-wire connectors to meet the cost, flexibility
and ease-of-use targets in industrial wiring applications.
The 9286 series of Thru-Wire connectors provides a high spring force Beryllium Copper
contact system that uses simple push button activation to insert and remove individual
stripped wires in the connection process. There is a forward and aft shrouded (to prevent
accidental activation) push button for each wire connection that can be operated
individually or simultaneously with a simple plastic tool or ball point pen tip. Up to eight
wires can be electrically connected in a single connector body which will support any
combination of wire gauges from 18AWG up to 26 AWG. Wires can be removed or
replaced up to 5 times so there is no need to replace the connector in a new installation.
ELECTRICAL
• Current Rating: 8 Amps / Contact
Voltage Rating: 300 VAC
9286
Series
00
Prefix
00X
Number of Ways
06
Plating
Option
06 = Pure Tin
all over
HOW TO ORDER
9
Color Options
9 = UL White
021
Wire Size
ENVIRONMENTAL
• Operating Temperature:
-40ºC to +125ºC
MECHANICAL
• Insulator Material: Glass-Filled
Nylon 46; UL94V0
Contact Material: Beryllium Copper /
Phosphor Bronze
• Plating: Tin over Nickel
• Replacibility: 5 Cycles
FEATURES AND BENEFITS
• High spring force top contact provides a lance type retention to capture
and retain the wire
Shrouded dual push button activation for easy wire insertion/removal
Accepts 18-26AWG Solid and Stranded wires; any combination
Expanded size offering to maximize application potential; 1, 2, 3, 4, 6 & 8
positions
Optional mounting tape to secure in panel mounting applications
Molded in position numbers and schematic for easy identification
APPLICATIONS
• Industrial/Machine Control; motors, solenoids,
PLC’s, pumps, valves, sensors, fans…
• Commercial/Building; fixtures, fire, security,
surveillance, blinds, sensors, controls…
• Commercial/Industrial LED; retail, office,
manufacturing, signage, displays…
• Application notes; refer to 201-01-135
Code No of Details
Ways
001 1 Page 3
002 2 Page 4
003 3 Page 5
004 4 Page 6
006 6 Page 7
008 8 Page 8
Code Wire Max Max
Gauge Conductor Insulation
021 18 to 26 1.05mm 2.10mm
AWG Diameter Diameter
Certification: UL File #E90723
CONNECT
INTER
3
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 1 WAY POKE-HOME – THRU WIRE
NOTES:
1. 1 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
SECTION ON A-A
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
4
NOTES:
1. 2 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 2 WAY POKE-HOME – THRU WIRE
SECTION ON A-A
CONNECT
INTER
5
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 3 WAY POKE-HOME – THRU WIRE
SECTION ON A-A
NOTES:
1. 3 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
6
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 4 WAY POKE-HOME – THRU WIRE
SECTION ON A-A
NOTES:
1. 4 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
7
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 6 WAY POKE-HOME – THRU WIRE
SECTION ON A-A
NOTES:
1. 6 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
8
Poke-Home Thru-Wire: WTW
00-9286
18-26 AWG 8 WAY POKE-HOME – THRU WIRE
SECTION ON A-A
NOTES:
1. 8 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 2.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 13.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 14.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
9
042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
ELECTRICAL
• Voltage Rating: 300 VAC
Current Rating: See matrix below
ENVIRONMENTAL
• Operating Temperature:
-40ºC to +130ºC
MECHANICAL
• Insulator Material; Glass-Filled Nylon
46; UL94V0
• Fixed Contact Material; Copper Alloy
• Flexing Contact; Stainless Steel
• Fixed Contact Plating; Tin over Nickel
• Durability; 3 Cycles
FEATURES AND BENEFITS
• Simple strip and poke-home wire insertion with twist and pull
wire extraction
• High spring force stainless steel contact maximizes cost,
strength and flexibility
• Accepts 18-24 AWG solid and stranded wires
• Expanded size offering to cover multiple power and signal
applications: 1p-6p
APPLICATIONS
• Industrial Machine Controls; motors, drives, sole-
noids, sensors, fans, pumps, etc...
• Commercial Buildings; controls, security, fire and
sensors
• Smart Grid; meters, breakers and panels
• SSL/LED; fixtures, signage and streetlights
• Application notes; refer to 201-01-172
CURRENT RATING
18AWG 20AWG 22AWG 24AWG
8A 5A 5A 3A
Wire-to-Wire (WTW) connectors have been used in the industrial market for
years with traditional 2-Piece (plug & socket) connector systems. These require
crimp and poke wire terminations to connect discrete wires together. While these
provide repeated pluggability and latching, they are often size and cost
prohibited in applications where the wires may only need to be replaced once or
twice during their life.
The reduced 9286-200 series of thru wire connectors expands on the already
proven 9286 poke-home discrete WTW family of connectors, but in a smaller
package size. The development of an active stainless steel spring contact
eliminates the need for push button activation to insert and remove wires which
offers a significant cost savings. The mechanical properties of this contact
provide maximum wire retention across a broad range of solid and stranded wire
gauges, making this connector very versatile in field installations.
9286
Series
00
Prefix
00X
Number of Ways
06
Plating Option
06 = Tin All Over
HOW TO ORDER
203
Wire Size
Code No of Details
Ways
001 1 Page 10
002 2 Page 11
003 3 Page 12
004 4 Page 13
005 5 Page 14
006 6 Page 15
Code Accepted Max
Wire Gauge Insulation
203 18 – 24 AWG 2.10mm Diameter
Solid or Stranded
X
Insulator Color
9 = White (Standard)
CONNECT
INTER
10 042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
NOTES:
1. 1 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 1 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
11
042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
NOTES:
1. 2 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 2 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
12 042216
NOTES:
1. 3 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 3 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
13
042216
NOTES:
1. 4 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 4 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
14 042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
NOTES:
1. 5 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 5 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
15
042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
NOTES:
1. 6 WAY WIRE TO WIRE POKE HOME CONNECTOR.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.10MM DIAMETER.
3. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0, COLOR SEE PAGE 9.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION
NOTES 201-01-172.
POKE HOME 6 WAY – THRU WIRE
18AWG TO 24AWG
CONNECT
INTER
16 042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
POKE HOME – THRU WIRE
WIRE TRIM
FOR FULL ASSEMBLY DETAILS REFER TO APPLICATION NOTE 201-01-172
POKE HOME – THRU WIRE
ASSEMBLY
REST POSITION OF CONTACT TIP
Insulation Diameter Wire Trim Length X
Up to 2.10 Diameter 4.00 ± 0.50
Above 2.10mm Diameter
See Application Notes 7.00 ± 0.50
201-01-172
CONNECT
INTER
17
Poke-Home Junction Box: WTW
00-9286
Wire-to-Wire connectors have been used in the industrial market for years with traditional
2-Piece (plug and socket) connector systems which require crimp and poke wire
terminations to connect electrical or electronic components. In the general wiring market
(2-3 wires) there are a number of connector styles available, however, they are limited in
sizes, expanded wire gauges and the ability to reuse them when repair or replacement
is needed. Based on the existing success of “Poke-Home” wire-to-board connectors,
AVX has developed a new family of wire-to-wire connectors to meet the cost, flexibility
and ease-of-use targets in industrial wiring applications.
The 9286 series of Junction Box connectors provide a high spring force Beryllium
Copper contact system that uses simple push button activation to insert and remove
individual stripped wires in the connection process. There is a forward and aft shrouded
(to prevent accidental activation) push button for each wire connection that can be
operated individually or simultaneously with a simple plastic tool or ball point pen tip. This
connector family has been designed to bring a single wire in and then have multiple
output (bus structure) wires of the same power or signal. Four, Six or Eight wires can be
electrically connected together in a single connector body which will support any
combination of wire gauges from 18AWG up to 26 AWG. Wires can be removed or
replaced up to 5 times so there is no need to replace the connector in a new installation.
ELECTRICAL
• Current Rating: 10 Amps total
Voltage Rating: 300v AC
9286
Series
00
Prefix
00X
Number of Ways
06
Plating Option
06 = Tin all over
HOW TO ORDER
121
Wire Size
ENVIRONMENTAL
• Operating Temperature:
-40ºC to +125ºC
MECHANICAL
• Insulator Material: Glass-Filled
Nylon 46; UL94V0
Contact Material: Beryllium Copper /
Phosphor Bronze
• Plating: Tin over Nickel
• Replacibility: 5 Cycles
FEATURES AND BENEFITS
• High spring force top contact provides a lance type retention to capture
and retain the wire
Shrouded dual push button activation for easy wire insertion/removal
Accepts 18-26AWG Solid and Stranded wires; any combination
Expanded size offering to maximize application potential; 4, 6 or 8
positions
Optional mounting tape to secure in panel mounting applications
Molded in position numbers and schematic for easy identification
APPLICATIONS
• Industrial/Machine Control; motors, solenoids,
PLC’s, pumps, valves, sensors, fans…
• Commercial/Building; fixtures, fire, security,
surveillance, blinds, sensors, controls…
• Commercial/Industrial LED; retail, office,
manufacturing, signage, displays…
• Application notes; refer to 201-01-135
Code No of Details
Ways
004 4 Page 18
006 6 Page 19
008 8 Page 20
Code Wire Max Max
Gauge Conductor Insulation
121 18 to 26 1.05mm 2.10mm
AWG Diameter Diameter
9
Color Options
9 = UL Red
Certification: UL File #E90723
CONNECT
INTER
18
Poke-Home Junction Box: WTW
00-9286
18-26 AWG 4 WAY POKE-HOME – JUNCTION BOX
SECTION ON A-A
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
NOTES:
1. 4 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
ALL TERMINALS INTERCONNECTED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 17.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 21.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 22.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
CONNECT
INTER
19
Poke-Home Junction Box: WTW
00-9286
18-26 AWG 6 WAY POKE-HOME – JUNCTION BOX
SECTION ON A-A
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
NOTES:
1. 6 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
ALL TERMINALS INTERCONNECTED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 17.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 21.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 22.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
CONNECT
INTER
20
Poke-Home Junction Box: WTW
00-9286
18-26 AWG 8 WAY POKE-HOME – JUNCTION BOX
NOTES:
1. 8 WAY WIRE TO WIRE “POKE-HOME” CONNECTOR, BUTTON OPERATED.
ALL TERMINALS INTERCONNECTED.
2. WIRE SIZES 18-26 AWG, MAXIMUM INSULATION DIAMETER 2.10MM.
3. SPLIT BUTTON ALLOWS THE WIRES TO BE INSERTED/WITHDRAWN INDEPENDENTLY.
4. INSULATION MATERIAL: NYLON 46, GLASS FILLED, UL94 V-0. COLOR SEE PAGE 17.
5. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
6. FOR FULL SPECIFICATION REFER TO ELCO SPECIFICATION 201-01-132.
FOR APPLICATION NOTES REFER TO ELCO SPECIFICATION 201-01-135.
7. GENERAL TOLERANCE ±0.20MM.
8. WIRE STRIP LENGTH GUIDE, SEE PAGE 21.
9. ADHESIVE STRIP FOR PANEL MOUNTING REFER TO PAGE 22.
10. FOR UL PRODUCT CODES UL REFERENCE E90723 (US AND CANADA).
SECTION ON A-A
PACKING DETAILS
Pack 400 pieces in a clear plastic bag.
CONNECT
INTER
21
042216
Reduced Junction Box Connector
18-24 AWG: WTW
9286-250
ELECTRICAL
• Voltage Rating: 300 VAC
Current Rating: See matrix below
ENVIRONMENTAL
• Operating Temperature:
-40ºC to +130ºC
MECHANICAL
Insulator Material; Glass-Filled Nylon
46; UL94V0
Fixed Contact Material; Copper Alloy
Flexing Contact; Stainless Steel
Fixed Contact Plating; Tin over Nickel
Durability; 3 Cycles
FEATURES AND BENEFITS
Simple strip and poke-home wire insertion with twist and
pull wire extraction
High spring force stainless steel contact maximizes cost,
strength and flexibility
Accepts 18-24 AWG solid and stranded wires
Expanded size offering to allow up to 8 wires to be
connected together
APPLICATIONS
Industrial Machine Controls; motors, drives,
solenoids, sensors, fans, pumps, etc...
Commercial Buildings; controls, security,
fire and sensors
Smart Grid; meters, breakers and panels
SSL/LED; fixtures, signage and streetlights
Application notes; refer to 201-01-172
CURRENT RATING
18AWG 20AWG 22AWG 24AWG
9A 8A 7A 3A
Wire-to-Wire (WTW) connectors have been used in the industrial market for
years with traditional 2-Piece (plug & socket) connector systems. These require
crimp and poke wire terminations to connect discrete wires together. While these
provide repeated pluggability and latching, they are often size and cost
prohibited in applications where the wires may only need to be replaced once or
twice during their life.
The reduced 9286-250 series of junction connectors expands on the already
proven 9286 poke-home discrete WTW family of connectors, but in a smaller
package size. Junction box connectors electrically connect each of the inserted
wires together, similar to a branch or splitter application but with multiple
outputs. The development of an active stainless steel spring contact eliminates
the need for push button activation to insert and remove wires which offers a
significant cost savings. The mechanical properties of this contact provide
maximum wire retention across a broad range of solid and stranded wire
gauges, making this connector very versatile in field installations.
9286
Series
00
Prefix
00X
Number of Ways
06
Plating Option
06 = Tin All Over
HOW TO ORDER
253
Wire Size
Code No of Details
Ways
004 4 Page 22
006 6 Page 23
008 8 Page 24
Code Accepted Max
Wire Gauge Insulation
253 18 – 24 AWG 2.10mm Diameter
Solid or Stranded
X
Insulator Color
Standard
9 = Red
Specal Order Only
0 = Black
2 = Brown
3 = Blue
4 = Yellow
6 = Green
7 = Orange
CONNECT
INTER
22 042216
Reduced Junction Box Connector
18-24 AWG: WTW
9286-250
NOTES:
1. 4 WAY WIRE TO WIRE POKE HOME CONNECTOR, JUNCTION BOX, ALL WIRES CONNECTED.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.100MM DIAMETER.
3. INSULATION MATERIAL: NYLON 6, GLASS FILLED, UL94 V-0, COLOR REFER TO PAGE 21.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION NOTES 201-01-172.
POKE HOME 4 WAY
18AWG TO 24AWG (ALL WIRES CONNECTED)
CONNECT
INTER
23
042216
Reduced Junction Box Connector
18-24 AWG: WTW
9286-250
POKE HOME 6 WAY
18AWG TO 24AWG (ALL WIRES CONNECTED)
NOTES:
1. 6 WAY WIRE TO WIRE POKE HOME CONNECTOR, JUNCTION BOX, ALL WIRES CONNECTED.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.100MM DIAMETER.
3. INSULATION MATERIAL: NYLON 6, GLASS FILLED, UL94 V-0, COLOR REFER TO PAGE 21.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION NOTES 201-01-172.
CONNECT
INTER
24 042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
POKE HOME 8 WAY
18AWG TO 24AWG (ALL WIRES CONNECTED)
NOTES:
1. 8 WAY WIRE TO WIRE POKE HOME CONNECTOR, JUNCTION BOX, ALL WIRES CONNECTED.
2. WIRE CONDUCTOR SIZES 18-24AWG (SOLID OR STRANDED).
MAXIMUM INSULATION 2.100MM DIAMETER.
3. INSULATION MATERIAL: NYLON 6, GLASS FILLED, UL94 V-0, COLOR REFER TO PAGE 21.
4. CONTACT MATERIAL: FIXED CONTACT: TIN PLATED COPPER ALLOY.
FLEXING CONTACT: STAINLESS STEEL.
5. PACKING IN BAGS, 1000 PIECES PER BAG.
6. FOR FURTHER DETAILS REFER TO SPECIFICATION 201-01-171 AND APPLICATION NOTES 201-01-172.
CONNECT
INTER
25
042216
Reduced Thru Wire Connector
18-24 AWG: WTW
9286-200
POKE HOME – JUNCTION BOX
WIRE TRIM
FOR FULL ASSEMBLY DETAILS REFER TO APPLICATION NOTE 201-01-172
POKE HOME – THRU WIRE
ASSEMBLY
REST POSITION OF CONTACT TIP
Insulation Diameter Wire Trim Length X
Up to 2.10 Diameter 4.00 ± 0.50
Above 2.10mm Diameter
See Application Notes 7.00 ± 0.50
201-01-172
CONNECT
INTER
26
CONNECT
INTER
Poke-Home Junction Box: WTW
00-9286
POKE-HOME BUTTON ACTIVATION TOOL
NOTES:
1. TOOL IS DOUBLE ENDED, END 1 ACTIVATES SINGLE BUTTON.
END 2 FOR SIMULTANEOUS BUTTON ACTIVATION.
2. WIRE WHEN TRIMMED TO BE STRAIGHT WITH NO BURRS.
3. FOR FULL ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-135.
4. SUPPLIED IN PACKS OF 100 PIECES.
SINGLE BUTTON OPERATION
TRIMMED WIRE
SIMULTANIOUS BUTTON OPERATION
9286 BUTTON ACTIVATION TOOL
06-9286-7001-01-000
CONNECT
INTER
27
CONNECT
INTER
Poke-Home Junction Box: WTW
00-9286
08-9286-400X-00-000 ADHESIVE MOUNTING TAPE
ACCESSORY NOT SUPPLIED WITH CONNECTORS
Matching Connectors
Part Number Dimension “A” 00-9286-00X-021-X06 00-9286-00X-121-X06
Thru Wire Junction Box
80-9286-4001-00-000 4.00 1 Way N/A
80-9286-4002-00-000 8.00 2 Way 4 Way
80-9286-4003-00-000 12.00 3 and 4 Way 6 and 8 Way
80-9286-4006-00-000 24.00 6 and 8 Way N/A
NOTES:
1. DOUBLE SIDED FOAM FILLED ADHESIVE TAPE.
2. WIDTH FOR 1 WAY, 2 WAY, 3 WAY AND 6 WAY CONNECTORS, FOR LENGTH SEE TABLE.
3. USED FOR ADHERE A 9286 CONNECTOR TO A FLAT SURFACE.
4. SOME SURFACES MAY REQUIRE THE USE OF A CLEANING SOLVENT TO ACHIEVE BEST RESULTS.
5. SUPPLIED CUT TO SIZE ON A REEL ON AN OVERSIZE BACKING STRIP PARTS 400 PER REEL.
S-WTW0M416-C
A KYOCERA GROUP COMPANY
http://www.avx.com
Contact:
AVX Greenville, SC
Tel: 864-967-2150
AVX Limited, England
Tel: +44-1252-770000
AVX S.A.S., France
Tel: +33-1-69-18-46-00
AVX GmbH, Germany
Tel: +49-0811-95949-0
AVX SRL, Italy
Tel: +39-02-614-571
AVX Czech Republic
Tel: +420-57-57-57-521
AVX/ELCO UK
Tel: +44-1638-675000
ELCO Europe GmbH
Tel: +49-2741-299-0
AVX S.A., Spain
Tel: +34-91-63-97-197
AVX Benelux
Tel: +31-187-489-337
AVX/Kyocera (S) Pte Ltd.,
Singapore
Tel: +65-6286-7555
AVX/Kyocera, Asia, Ltd.,
Hong Kong
Tel: +852-2363-3303
AVX/Kyocera Yuhan Hoesa,
South Korea
Tel: +82-2785-6504
AVX/Kyocera HK Ltd.,
Taiwan
Tel: +886-2-2656-0258
AVX/Kyocera (M) Sdn Bhd,
Malaysia
Tel: +60-4228-1190
AVX/Kyocera International
Trading Co. Ltd.,
Shanghai
Tel: +86-21-3255 1933
AVX/Kyocera Asia Ltd.,
Shenzen
Tel: +86-755-3336-0615
AVX/Kyocera International
Trading Co. Ltd.,
Beijing
Tel: +86-10-6588-3528
AVX/Kyocera India
Liaison Office
Tel: +91-80-6450-0715
AMERICAS EUROPE ASIA-PACIFIC
KED Hong Kong Ltd.
Tel: +852-2305-1080/1223
KED Hong Kong Ltd.
Shenzen
Tel: +86-755-3398-9600
KED Company Ltd.
Shanghai
Tel: +86-21-3255-1833
KED Hong Kong Ltd.
Beijing
Tel: +86-10-5869-4655
KED Taiwan Ltd.
Tel: +886-2-2950-0268
KED Korea Yuhan Hoesa,
South Korea
Tel: +82-2-783-3604/6126
KED (S) Pte Ltd.
Singapore
Tel: +65-6509-0328
Kyocera Corporation
Japan
Tel: +81-75-604-3449
ASIA-KED
(KYOCERA Electronic Devices)