How to Order
P265 Pressure Transducer
Pressure Range
Reference
0 - 15 PSI
0 - 20 PSI
0 - 30 PSI
0 - 50 PSI
0 - 75 PSI
0 -100 PSI
0 - 150 PSI
0 - 200 PSI
0 - 300 PSI
0 - 500 PSI
0 - 750 PSI
0 - 1000 PSI
A
G
S
Absolute
Gage
Sealed Gage
Seal Material
Nitrile
Neoprene
Fluorocarbon
Fluorosilicone
Ethylene Propylene
-40 to + 121° C
-34 to + 107° C
-20 to + 125° C
-40 to + 125° C
-40 to + 121° C
B
C
D
E
F
Pressure Connection
1/4 - 18 NPT (External Threads)
3/8 - 24 UNF-2A (Male)
3/8 - 24 UNF-2B (Female)
1/8 - 27 NPT
1
2
3
4
Example: P265 - 500 - S - F - 1 - A
Description: P265 Pressure Transmitter, 0 - 500 PSIS (Sealed Gage),
with Ethylene Propylene Seal Material, 1/4 - 18 NPT
Pressure Connection, and Mating Connector
P265 - 500 - S - F - 1 - A
Electrical Connection
With Mating Connector, w/12”, 18 AWG Leads
12”, 18 AWG Leads
Metri-Pack 150 Series Connector
A
B
C
15
20
30
50
75
100
150
200
300
500
750
1000
© 2013 Kavlico. All rights reserved.
Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Kavlico reserve the right to
modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the
appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion,
use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Before installation and operation, ensure that the appropriate pressure sensor has
been selected in terms of pressure range, design and specific measuring conditions.
Non-compliance can result in serious injury and/or damage to the equipment.
Technical Specifications
Note: Performance Specifications with 5v ± 0.002 Vdc supply at 25°C
Pressure Ranges:
Proof Pressure:
Burst Pressure:
Supply Voltage:
Supply Current:
Response Time:
Output Voltage
Zero/Null Pressure:
Full Pressure:
Ratiometricity:
Total Error Band:
Output Impedance:
Operating Temperature:
Storage Temperature:
Service Life:
Vibration:
Shock:
Ingress Protection:
Stability:
Weight:
Electrical Termination:
Pressure Connection:
Output Load:
Over-Voltage Protection:
Reverse Polarity Protection:
Main Housing Material:
0 – 15 PSI through 0 – 1,000 PSI
Absolute, Gage or Sealed Gage
5x (FSO) (15 through 75 PSI)
3x (FSO) (100 through 500 PSI)
2x (FSO) (750 and 1,000 PSI)
1,000 (15 through 75 PSI)
2,000 PSI (100 through 1,000 PSI)
4.50 Vdc to 5.50 Vdc
5 mA (Max)
15ms Max to 63% of F.S. Pressure
with Step Change on Input
0.50 ±0.08 Vdc
4.50 ±0.08 Vdc
±0.5% of Span
2.0% of Span (-20˚C to +100˚C)
< 100 Ω
-40°C to +125°C
(Seal Material Dependant)
-40°C to +135°C
10 Million Full Pressure Cycles
10G P-P Sinusoidal, from 10-2000Hz
75 G ½ Sine Wave
IP67
±0.5% of Full Span over 1-Year
100 grams (Max)
Packard Electric Metri-Pack 150 Series
See “How to Order”
>25k Ω
16 Vdc
-5 Vdc
316 Stainless Steel