DS1085L 3.3V EconOscillator Frequency Synthesizer www.maxim-ic.com FEATURES User-Programmable Frequency Synthesizer Programmable From 4.1kHz to 66MHz Dual Synchronous Outputs 4.13MHz to 66MHz Reference Oscillator Output 4.1kHz to 66MHz Main Oscillator Output Single 3.0 to 3.6V Supply Three Resolution Options 2-Wire Serial Interface 0.75% Absolute Accuracy Nonvolatile (NV) Frequency Settings No External Timing Components Power-Down Mode OUT1 1 8 SCL OUT0 2 7 SDA VCC 3 CTRL1 GND 4 6 5 CTRL0 SO (150mil) PIN DESCRIPTION OUT1 - Main Oscillator Output OUT0 - Reference Oscillator Output - Power-Supply Voltage VCC GND - Ground CTRL1 - Control Pin for OUT1 CTRL0 - Control Pin for OUT0 SDA - 2-Wire Serial Data Input/Output SCL - 2-Wire Serial Clock ORDERING INFORMATION PIN ASSIGNMENT DS1085LZ-5 150mil SO STEP SIZE 5kHz DS1085LZ-12 150mil SO 12.5kHz 4.1kHz to 66MHz DS1085LZ-25 150mil SO 25kHz 4.1kHz to 66MHz DEVICE PACKAGE OSCILLATOR OUTPUT RANGE 4.1kHz to 66MHz DESCRIPTION The DS1085L is a dual-output frequency synthesizer requiring no external timing components for operation. It can be used as a standalone oscillator or as a dynamically programmed, processor-controlled peripheral device. An internal master oscillator can be programmed from 33MHz to 66MHz with three resolution options of 5kHz, 12.5kHz, and 25kHz. A programmable 3-bit prescaler (divide-by-1, 2, 4, or 8) permits the generation of a reference oscillator output (OUT0) from the master, ranging from 4.13MHz to 66MHz. A second independent prescaler and a 1-to-1025 divider allow the generation of a main oscillator output (OUT1) from 4.1kHz to 66MHz. The two outputs, although synchronous with the master, can be independently programmed. The combination of programmable master oscillator, prescalers, and dividers allows the generation of thousands of user-specified frequencies. All master oscillator, prescaler, and divider settings are stored in NV (EEPROM) memory, providing a default value on power-up that allows it to be used as a standalone oscillator. A 2-wire serial interface allows in-circuit, on-the-fly programming of the master oscillator, prescalers (P0 and P1), and divider (N). This allows dynamic frequency modification, if required, or, for fixed-frequency applications, the DS1085L can be used with factory- or user-programmed values. EconOscillator is a trademark of Dallas Semiconductor. 1 of 21 051606 DS1085L External control inputs, CTRL1 and CTRL0, enable or disable the two oscillator outputs. Both outputs feature a synchronous enable that ensures no output glitches when the output is enabled and a constant time interval (for a given frequency setting) from an enable signal to the first output transition. These inputs can also be configured to disable the master oscillator, putting the device into a low-power mode for power-sensitive applications. Figure 1. DS1085L BLOCK DIAGRAM 0M0 0M1 1M0 1M1 OVERVIEW A block diagram of the DS1085L is shown in Figure 1. The DS1085L consists of five major components: Internal master oscillator (33MHz to 66MHz) Master oscillator control DAC Prescalers (divide-by-1, 2, 4, or 8) Programmable divider (divide-by-1 to 1025) Control registers The internal master oscillator provides the reference clock (MCLK), which is fed to the prescalers and programmable dividers. The frequency of the oscillator can be user-programmed over a two-to-one range in increments equal to the step size, by means of a 10-bit control DAC. The master oscillator range is 33MHz to 66MHz, which is larger than the range possible with the 10-bit DAC resolution and available step sizes. Therefore, an additional register (OFFSET) is provided that can be used to select the range of frequency over which the DAC is used (see Table 1). 2 of 21 DS1085L Table 1. DEVICE COMPARISONS BY PART NUMBER PART NUMBER STEP SIZE (kHz) DAC SPAN (MHz) OFFSET SIZE (MHz) DS1085LZ-5 5 5.12 2.56 DS1085LZ-12 12.5 12.80 3.20 DS1085LZ-25 25 25.60 3.20 For further description of use of the OFFSET register see the REGISTER FUNCTIONS section. The master clock can be routed directly to the outputs (OUT0 and OUT1) or through separate prescalers (P0 and P1). In the case of OUT1, an additional programmable divider (N) can be used to generate frequencies down to 4.1kHz. The prescaler (P0) divides MCLK by 1, 2, 4, or 8 before routing MCLK to the reference output (OUT0) pin. The prescaler (P1) divides MCLK by 1, 2, 4, or 8 before routing MCLK to the programmable divider (N), and ultimately to the main output (OUT1) pin. The programmable divider (N) divides the prescaler output (P1) by any number selected between two and 1025 (10 bits) to provide the main output (OUT1), or it can be bypassed altogether by use of the DIV1 register bit. The value of N is stored in the DIV register. The control registers are user-programmable through a 2-wire serial interface to determine operating frequency (values of DAC, OFFSET, P0, P1, and N) and modes of operation. Once programmed, the register settings are nonvolatile and only need reprogramming if it is desired to reconfigure the device. PIN DESCRIPTIONS PIN NAME 1 OUT1 2 OUT0 3 4 Vcc GND 5 CTRL0 6 CTRL1 7 SDA 8 SCL FUNCTION This main oscillator output frequency is determined by the control register settings for the oscillator (DAC and OFFSET), prescaler P1 (mode bits 1M0 and 1M1), and divider N (DIV). The reference output is taken from the output of the reference select mux. Its frequency is determined by the control register settings for prescaler P0 (mode bits 0M0 and 0M1) (see Table 2). Power Supply Ground A multifunction control input pin that can be programmed to function as a mux select, ouput enable, and/or a power-down. Its function is determined by the user-programmable control register values of EN0, SEL0, and PDN0 (see Table 2). A multifunction control input pin that can be programmed to function as an output enable and/or a power-down. Its function is determined by the user-programmable control register value of PDN1 (see Table 3). I/O pin for the 2-wire serial interface used for data transfer. Input pin for the 2-wire serial interface used to synchronize data movement over the serial interface. 3 of 21 DS1085L Table 2. DEVICE MODE USING OUT0 EN0 (BIT) SEL0 (BIT) PDN0 (BIT) CTRL0 OUT0 CTRL0 DEVICE (PIN) (PIN) FUNCTION MODE 1 High-Z Power-Down* Power-Down*** 0 0 0 0 High-Z Active Mux Select 1 MCLK/M 0 1 0 Active 0 MCLK Output Enable 1 High-Z 1 0 0 Active 0 MCLK 1 High-Z Output Enable 1 1 0 Active** 0 MCLK/M Power-Down 1 High-Z Power-Down X 0 1 0 MCLK Active 1 High-Z Power-Down Power-Down X 1 1 0 MCLK/M Active * This mode is for applications where OUT0 is not used, but CTRL0 is used as a device shutdown. ** Factory default setting. ***See standby (power-down) current specification for power-down current range. Table 3. DEVICE MODE USING OUT1 PDN1 CTRL1 (BIT) (PIN) 0 0 0 1 1 0 1 1 *Factory default setting CTRL1 FUNCTION Output Enable Power-Down OUT1 (PIN) OUT CLK High-Z OUT CLK High-Z DEVICE MODE Active* Active Power-Down NOTE: Both CTRL0 and CTRL1 can be configured as power-downs. They are internally "OR" connected so either of the control pins can be used to provide a power-down function for the whole device, subject to appropriate settings of the PDN0 and PDN1 register bits (see Table 4). Table 4. SHUTDOWN CONTROL WITH PDN0 AND PDN1 PDN0 (BIT) 0 0 1 1 PDN1 (BIT) 0 1 0 1 SHUTDOWN CONTROL NONE CTRL1 CTRL0 CTRL1 OR CTRL0 4 of 21 DS1085L REGISTER FUNCTIONS The user-programmable registers can be used to determine the mode of operation (MUX), operating frequency (DAC, OFFSET, DIV), and bus settings (ADDR). The functions of the registers are described in this section, but the details of how these registers are programmed can be found in a later section. The register settings are nonvolatile, with the values being stored automatically or as required in EEPROM when the registers are programmed through the SDA and SCL pins. DAC WORD (Address 08h) MSB d9 d8 d7 d6 d5 d4 First Data Byte d3 LSB d2 MSB d1 d0 X X X X Second Data Byte LSB X X X = Don't care. The DAC word (d0-d9) controls the frequency of the master oscillator. The resolution of this register depends on the step size of the device. The absolute frequency of the device also depends on the value of the OFFSET register (see Tables 5 and 6). Table 5. DEVICE DEFAULT SETTINGS DS1085LZ-5 Frequency 48.58MHz DAC 500 Offset OS DS1085LZ-12 Frequency DAC Offset 52.3MHz 600 OS DS1085LZ-25 Frequency DAC 50.9MHz 500 Offset OS For any given value of OFFSET the master oscillator frequency can be derived as follows: Frequency = Min Frequency + DAC x Step Size where: Min frequency is the lowest frequency shown in Table 6 for the corresponding offset. DAC is the value of the DAC register (0-1023). Step size is the step size of the device (5kHz, 12.5kHz, or 25kHz). OS is the decimal, integer value of the 5 MSBs of the RANGE register. OFFSET BYTE (Address MSB X X X = Don't care. 0Eh) X O4 O3 O2 O1 LSB O0 The OFFSET byte (O0-O4) determines the range of frequencies that can be obtained within the absolute minimum and maximum range of the oscillator. Correct operation of the device is not guaranteed for values of OFFSET not shown in Table 6. 5 of 21 DS1085L Table 6. FREQUENCY vs. OFFSET OFFSET OS - 10 OS - 9 OS - 8 OS - 7 OS - 6 OS - 5 OS - 4 OS - 3 OS - 2 OS - 1 OS* OS + 1 OS + 2 OS + 3 OS + 4 OS + 5 OS + 6 DS1085LZ-5 FREQUENCY RANGE -- -- -- -- 30.7 to 35.8 33.3 to 38.4 35.8 to 41.0 38.4 to 43.5 41.0 to 46.1 43.5 to 48.6 46.1 to 51.2 48.6 to 53.8 51.2 to 56.3 53.8 to 58.9 56.3 to 61.4 58.9 to 64.0 61.4 to 66.6 DS1085LZ-12 FREQUENCY RANGE -- -- -- -- 25.6 to 38.4 28.8 to 41.6 32.0 to 44.8 35.2 to 48.0 38.4 to 51.2 41.6 to 54.4 44.8 to 57.6 48.0 to 60.8 51.2 to 64.0 54.4 to 67.2 57.6 to 70.4 60.8 to 73.6 64.0 to 76.8 DS1085LZ-25 FREQUENCY RANGE -- -- -- -- 19.2 to 44.8 22.4 to 48.0 25.6 to 51.2 28.8 to 54.4 32.0 to 57.6 35.2 to 60.8 38.4 to 64.0 41.6 to 67.2 44.8 to 70.4 48.0 to 73.6 51.2 to 76.8 54.4 to 80.0 57.6 to 83.2 *OS is the OFFSET default setting. OS is the integer value of the five MSBs of RANGE register. These ranges include values outside the oscillator range of 33MHz to 66MHz. When using these ranges, values of DAC must be chosen to keep the oscillator within range. Correct operation of the device is not guaranteed outside the range 33MHz to 66MHz. MUX WORD (Address 02h) The MUX word controls several functions. Its bits are organized as follows: MSB LSB MSB NAME * PDN1 PDN0 SEL0 EN0 0M1 0M0 1M1 1M0 Default 0 0 0 1 1 0 0 0 0 Setting * This bit must be set to zero. X = Don't care. 6 of 21 LSB DIV1 - - - - - - 0 X X X X X X DS1085L The functions of the individual bits are described in the following paragraphs. DIV1 (Default Setting = 0) This bit allows the output of the prescaler P1 to be routed directly to the OUT1 pin (DIV1 = 1). In this condition, the N divider is bypassed so the programmed value of N is ignored. If DIV1 = 0, the N divider functions normally. EN0 (Default Setting = 1) If EN0 = 1 and PDN0 = 0, the CTRL0 functions as an output enable for OUT0, the frequency of the output being determined by the SEL0 bit. If PDN0 = 1, the EN0 bit is ignored, CTRL0 functions as a power-down, and OUT0 is always enabled on power-up, its frequency determined by the SEL0 bit. If EN0 = 0, the function of CTRL0 is determined by the SEL0 and PDN0 bits (see Table 2). SEL0 (Default Setting = 1) If SEL0 = 1 and EN0 = PDN0 = 0, the CTRL0 pin determines whether the prescaler is bypassed, controlling the output frequency. If CTRL0 = 0, the output frequency equals MCLK. If CTRL0 = 1, the output frequency equals MCLK/M. If either EN0 or PDN0 = 1, the CTRL0 pin functions as an output enable or power-down and the SEL0 bit determines whether the prescaler is bypassed, thus controlling the output frequency. If SEL0 = 0, the output is MCLK, the master clock frequency. If SEL0 = 1, the output is the output frequency of the M prescaler (see Table 2). PDN0 (Default Setting = 0) If PDN0 = 1, the CTRL0 performs a power-down function, regardless of the setting of the other bits. If PDN0 = 0, the function of CTRL0 is determined by the values of EN0 and SEL0 (see Table 2). 0M0, 0M1, 1M0, 1M1 (Default Setting = 0) These bits set the prescaler's (P0 and P1) divisor (M) to 1, 2, 4, or 8 (see Table 7a and 7b). 7 of 21 DS1085L Table 7a. PRESCALER P0 DIVISOR M SETTINGS 0M1 0M0 PRESCALER P0 DIVISOR "M" 0 0 1* 0 1 2 1 0 4 1 1 8 *Factory Default Setting Table 7b. PRESCALER P1 DIVISOR M SETTINGS 1M1 1M0 PRESCALER P1 DIVISOR "M" 0 0 1* 0 1 2 1 0 4 1 1 8 *Factory Default Setting NOTE: When EN0 = SEL0 = PDN0 = 0, CTRL0 also functions as a power-down. This is a special case for situations when OUT0 is not used. Under these conditions all the circuitry associated with OUT0 is powered down. OUT0 is powered down (see Table 2). PDN1 (Default Setting = 0) If PDN1 = 1, CTRL1 functions as a power-down (see Table 3). * If PDN1 = 0, CTRL1 functions as an output enable for OUT1 (see Table 3). NOTES FOR OUTPUT ENABLE AND POWER-DOWN: 1) 2) 3) 4) 5) Both enables are "smart" and wait for the output to be low before going High-Z. A power-down sequence first disables both outputs before powering down the device. On power-up, the outputs are disabled until the clock has stabilized (~8000 cycles). In power-down mode the device cannot be programmed. A power-down command must persist for at least two cycles of the lowest output frequency plus 10s. DIV WORD (N) (Address 01h) MSB N9 N8 N7 N6 N5 N4 First Data Byte LSB N3 N2 MSB N1 N0 X = Don't care. 8 of 21 X X X X Second Data Byte X LSB X DS1085L N The DIV word sets the programmable divider. These 10 bits (N0-N9) determine the value of the programmable divider (N). The range of divisor values is from two to 1025, and is equal to the programmed value of N plus 2 (see Table 8). Table 8. PROGRAMMABLE DIVISOR N VALUES BIT VALUE 00000000 00XXXXXX 00000000 01XXXXXX -- -- -- -- 11111111 11XXXXXX * Factory Default Setting DIVISOR (N) 2* 3 -- -- -- -- 1025 ADDR BYTE (Address 0Dh) MSB -- X NAME Factory Default X = Don't care. -- X -- X -- X WC 0 A2 0 A1 0 LSB A0 0 A0, A1, A2 (Default Setting = 000) These device select bits determine the 2-wire address of the device. WC (Default Setting = 0) This bit determines when/if the EEPROM is written to after register contents have been changed. If WC = 0, EEPROM is written automatically after a write register command. If WC = 1, EEPROM is only written when the "WRITE" command is issued. In applications where the register contents are frequently rewritten, WC should be set to 1; otherwise, it is necessary to wait for an EEPROM write cycle to complete (up to 10ms) between writing to the registers. Regardless of the value of the WC bit, when the ADDR register (A0, A1, A2) is written, the current value in all registers (DAC, OFFSET, DIV, MUX, and ADDR) are immediately to the EEPROM. RANGE REGISTER (Address 37h) MSB OS5 OS4 OS3 OS2 OS1 X X X X X X X X X X The first five bits of the RANGE register contain the default OFFSET value. The decimal value of the RANGE register is the value OS that is referred to in Table 6. The RANGE register is read-only. 9 of 21 LSB X DS1085L COMMAND SET Data and control information is read from and written to the DS1085L in the format shown in Figure 3. To write to the DS1085L, the master issues the slave address of the DS1085L and the R/ W bit is set to 0. After receiving an acknowledge, the bus master provides a command protocol. After receiving this protocol, the DS1085L issues an acknowledge, and then the master can send data to the DS1085L. If the DS1085L is to be read, the master must send the command protocol as before, and then issue a repeat START condition and then the control byte again, this time with the R/ W bit set to 1 to allow reading of the data from the DS1085L. The command set for the DS1085L is listed as follows: Access DAC [08h] If R/ W is 0, this command writes to the DAC register. After issuing this command, the next data byte values are written into the DAC register. If R/ W is 1, the next data bytes read are the values stored in the DAC register. This is a 2-byte transfer, the first byte contains the eight MSBs, and the second byte contains the two LSBs in the most significant positions of the data byte. The remaining six bits are ignored and can be written with any value (if read, these bits are 0). Access OFFSET [0Eh] If R/ W is 0, this command writes to the OFFSET register. After issuing this command, the next data byte value is written into the OFFSET register. If R/ W is 1, the next data byte read is the value stored in the OFFSET register. This is a single-byte transfer of which only the five LSBs (last five bits) are used. The remaining three bits can be written with any value to complete the data byte (if read, these bits are 1). Access DIV [01h] If R/ W is 0, this command writes to the DIV register. After issuing this command, the next data byte values are written into the DIV register. If R/ W is 1, the next data bytes read are the values stored in the DIV register. This register has a 10-bit value. The upper eight bits are sent first, followed by a second byte that contains the two LSBs of the register value in the most significant positions of the data byte. The remaining six bits are ignored and can be set to any value (if read, these bits are 0). Access MUX [02h] If R/ W is 0, this command writes to the MUX register. After issuing this command, the next data byte values are written into the MUX register. If R/ W is 1, the next data bytes read are the values stored in the MUX register. This register has a 10-bit value. The upper eight bits are sent first, followed by a second byte that contains the two LSBs of the register value in the most significant positions of the data byte. The remaining six bits are ignored and can be set to any value (if read, these bits are 0). Access ADDR [0Dh] If R/ W is 0, this command writes to the ADDR register. After issuing this command, the next data byte value is written into the ADDR register. If R/ W is 1, the next data byte read is the value stored in the ADDR register. This is a single-byte transfer. This register has a 5-bit value, the first three bits of a write can be any value followed by the five active bits (if read, the first three bits are 0). 10 of 21 DS1085L Access RANGE [37h] If R/ W is 1, the next data bytes read are the values stored in the RANGE register. This register has a 14bit value. The upper eight bits are sent first, followed by a second byte that contains the five LSBs of the register value in the most significant positions of the data byte. The upper five MSB's of the first byte contain the OS value for the frequency adjust Table 6. The register is read-only. Write E2 [3Fh] If WC = 0, the EEPROM is automatically written to at the end of each write command. This is a DEFAULT condition. In this case the command "WRITE E2" is not needed. If WC = 1, the EEPROM is written when the "WRITE E2" command is issued. On receipt of the "WRITE E2" command, the contents of the DAC, OFFSET, ADDR, DIV and MUX registers are written into the EEPROM, thus locking in the register settings. EXCEPTION: The DAC, OFFSET, ADDR, DIV, and MUX registers are always automatically written to EEPROM after a write to the ADDR register regardless of the value of the WC bit. 11 of 21 DS1085L 2-WIRE SERIAL DATA BUS The DS1085L communicates through a 2-wire serial interface. A device that sends data onto the bus is defined as a transmitter, and a device receiving data as a receiver. The device that controls the message is called a "master." The devices that are controlled by the master are "slaves." A master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions must control the bus. The DS1085L operates as a slave on the 2-wire bus. Connections to the bus are made through the open-drain I/O lines SDA and SCL. The following bus protocol has been defined (see Figure 2): Data transfer can be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data line while the clock line is high are interpreted as control signals. Accordingly, the following bus conditions have been defined: Bus not busy: Both data and clock lines remain HIGH. Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a START condition. Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH, defines the STOP condition. Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data bytes transferred between START and STOP conditions is not limited, and is determined by the master device. The information is transferred byte-wise and each receiver acknowledges with a ninth bit. Within the bus specifications a regular mode (100kHz clock rate) and a fast mode (400kHz clock rate) are defined. The DS1085L works in both modes. Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the byte has been received. The master device must generate an extra clock pulse that is associated with this acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable LOW during the HIGH period of the acknowledge-related clock pulse. Of course, setup and hold times must be taken into account. When the DS1085L EEPROM is being written to, it is not able to perform additional responses. In this case, the slave DS1085L sends a not acknowledge to any data transfer request made by the master. It resumes normal operation when the EEPROM operation is complete. 12 of 21 DS1085L A master must signal an end of data to the slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data line HIGH to enable the master to generate the STOP condition. Figure 2. DATA TRANSFER ON 2-WIRE SERIAL BUS Figures 2, 3, and 4 detail how data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/W bit, two types of data transfer are possible: 1) Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the master is the slave address. Next follows a number of data bytes. The slave returns an acknowledge bit after each received byte. 2) Data transfer from a slave transmitter to a master receiver. The first byte (the slave address) is transmitted by the master. The slave then returns an acknowledge bit. Next follows a number of data bytes transmitted by the slave to the master. The master returns an acknowledge bit after all received bytes other than the last byte. At the end of the last received byte, a not acknowledge is returned. The master device generates all of the serial clock pulses and the START and STOP conditions. A transfer is ended with a STOP condition or with a repeated START condition. Since a repeated START condition is also the beginning of the next serial transfer, the bus is not released. The DS1085L can operate in the following two modes: 1) Slave receiver mode: Serial data and clock are received through SDA and SCL. After each byte is received, an acknowledge bit is transmitted. START and STOP conditions are recognized as the beginning and end of a serial transfer. Address recognition is performed by hardware after reception of the slave address and direction bit. 2) Slave transmitter mode: The first byte is received and handled as in the slave receiver mode. However, in this mode, the direction bit indicates that the transfer direction is reversed. Serial data is transmitted on SDA by the DS1085L while the serial clock is input on SCL. START and STOP conditions are recognized as the beginning and end of a serial transfer. 13 of 21 DS1085L SLAVE ADDRESS A control byte is the first byte received following the START condition from the master device. The control byte consists of a 4-bit control code; for the DS1085L, this is set as 1011 binary for read and write operations. The next three bits of the control byte are the device select bits (A2, A1, A0). The address bits to which the DS1085L responds are factory set to 000, but can be altered by writing new values to the ADDR register. After the new address is written, the DS1085L responds only to the new address bit values. The master uses this to select which of eight devices are to be accessed. The set bits are in effect the three least significant bits of the slave address. The last bit of the control byte (R/W) defines the operation to be performed. When set to a 1, a read operation is selected; when set to a 0, a write operation is selected. Following the START condition, the DS1085L monitors the SDA bus checking the device type identifier being transmitted. Upon receiving the 1011 code and appropriate device select bits, the slave device outputs an acknowledge signal on the SDA line. Figure 3. TIMING DIAGRAM 14 of 21 DS1085L Figure 4. 2-WIRE SERIAL COMMUNICATION WITH DS1085L 15 of 21 DS1085L ABSOLUTE MAXIMUM RATINGS* Voltage on Any Pin Relative to Ground Operating Temperature Range Storage Temperature Range Soldering Temperature -0.5V to +6.0V 0C to +70C -55C to +125C See IPC/JEDEC J-STD-020A * This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability. DC ELECTRICAL CHARACTERISTICS PARAMETER Supply Voltage High-Level Output Voltage (OUT1, OUT0) Low-Level Output Voltage (OUT1, OUT0) High-Level Input Voltage (CTRL1, CTRL0, SDA, SCL) Low-Level Input Voltage (CTRL1, CTRL0, SDA, SCL) High-Level Input Current (CTRL1, CTRL0, SDA, SCL) Low-Level Input Current (CTRL1, CTRL0, SDA, SCL) SYMBOL VCC (VCC = 3.3V 10%, TA = 0C to +70C.) CONDITION VOH IOH = -4mA, Vcc = Min VOL IOL = 4mA MIN 3.0 TYP 3.3 MAX 3.6 2.4 UNITS V V 0.4 V VIH 0.7 x VCC VCC + 0.3 V VIL -0.3 0.3 x VCC V 1 A IIH VCC = 3.6V IIL VIL = 0 Supply Current (Active) ICC Standby Current (Power-Down) ICCQ CL = 15pF (both outputs, at default frequency) Power-down mode 16 of 21 -1 A 15 mA 1.5 mA NOTES 1 DS1085L MASTER OSCILLATOR CHARACTERISTICS (VCC = 3.3V 10%, TA = 0C to +70C.) PARAMETER Master Oscillator Range SYMBOL fOSC Default Master Oscillator Frequency f0 Master Oscillator Frequency Tolerance Df0 f0 Voltage Frequency Variation Temperature Frequency Variation Integral Nonlinearity of Frequency DAC DfV f0 DfT f0 INL CONDITION -5 version -12 version -25 version VCC = 3.3V, TA = +25C SYMBOL TYP MAX 66 48.58 52.3 50.9 +0.75 DAC step size Overvoltage range, TA = +25C Default freq. -0.75 +0.75 -1.0 +1.0 DAC step size Overtemperature range, Vcc = 3.3V Default freq. 66MHz 33MHz DAC range Entire range -1.0 +1.0 -0.75 +0.75 -0.75 -1.5 -0.3 -0.4 UNITS MHz NOTES 7 MHz -0.75 Default frequency AC ELECTRICAL CHARACTERISTICS PARAMETER Frequency Stable After DIV Change Frequency Stable After DAC or OFFSET Change Power-Up Time Enable of OUT0/1 After Exiting Power-Down Mode OUT0/1 High-Z After Entering Power-Down Mode Load Capacitance Output Duty Cycle (OUT0, OUT1) MIN 33 +0.75 +1.5 +0.3 +0.4 % 2, 17 % 3 % % % 4, 5 6 (VCC = 3.3V 10%, TA = 0C to +70C.) CONDITION MIN MAX UNITS 1 Period 0.2 1 ms 8 0.1 0.5 ms 9 tstab 500 s tstab 1 ms 50 pF 60 % tpor + tstab CL TYP 15 40 17 of 21 NOTES 10 DS1085L AC ELECTRICAL CHARACTERISTICS: 2-WIRE INTERFACE (VCC = 3.3V 10%, TA = 0C to +70C.) PARAMETER SCL Clock Frequency Bus Free Time Between a STOP and START Condition Hold Time (Repeated) START Condition SYMBOL fSCL tBUF tHD:STA LOW Period of SCL tLOW HIGH Period of SCL tHIGH Setup Time for a Repeated START tSU:STA Data Hold Time tHD:DAT Data Setup Time tSU:DAT Rise Time of Both SDA and SCL Signals Fall Time of Both SDA and SCL Signals Setup Time for STOP Capacitive Load for Each Bus Line NV Write-Cycle Time tR tF tSU:STO CONDITION Fast mode Standard mode Fast mode MIN Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode 4.7 0.6 4.0 1.3 4.7 0.6 4.0 0.6 4.7 0 0 100 250 TYP MAX UNITS NOTES 400 14 kHz 100 1.3 20 + 0.1CB 20 + 0.1CB ms ms 11 ms ms ms 0.9 300 1000 300 1000 0.6 4.0 ms 12, 13 ns 14 ns 15 ns 15 ms CB 400 pF 15 tWR 10 ms 16 NOTES: 1) All voltages are referenced to ground. 2) This is the absolute accuracy of the output frequency at the default settings. 3) This is the percent frequency change that is observed in output frequency with changes in voltage from nominal voltage at a temperature of TA = +25C. 4) This is the percentage frequency change from the +25C frequency due to temperature at a nominal voltage of 3.3V. 5) The maximum temperature change varies with the master frequency setting. The minimum occurs at the default master frequency (fdefault). The maximums occur at the extremes of the master oscillator frequency range (33MHz or 66MHz) (see Figure 5). 6) The integral nonlinearity of the frequency adjust DAC is a measure of the deviation from a straight line drawn between the two endpoints of a range. 18 of 21 DS1085L 7) DAC and OFFSET register settings must be configured to maintain the clock frequency within this range. Correct operation of the device is not guaranteed if these limits are exceeded. 8) Frequency settles faster for small charges in value. During a change, the frequency changes smoothly from the original value to the new value. 9) This indicates the time taken between power-up and the outputs becoming active. An on-chip delay is intentionally introduced to allow the oscillator to stabilize. tstab is equivalent to approximately 8000 clock cycles and hence depends on the programmed clock frequency. 10) Output voltage swings can be impaired at high frequencies combined with high-output loading. 11) After this period, the first clock pulse is generated. 12) A device must internally provide a hold time of at least 300ns for the SDA signal (referred to the VIH MIN of the SCL signal) in order to bridge the undefined region of the falling edge of SCL. 13) The maximum tHD:DAT need only be met if the device does not stretch the LOW period (tLOW ) of the SCL signal. 14) A fast mode device can be used in a standard mode system, but the requirement tSU:DAT > 250ns must then be met. This is automatically the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line at least tR MAX + tSU:DAT = 1000ns + 250ns = 1250ns before the SCL line is released. 15) CB--total capacitance of one bus line in picofarads; timing referenced to 0.9VCC and 0.1VCC. 16) EEPROM write begins after a STOP condition occurs. 17) Typical frequency shift due to aging is 0.5%. Aging stressing includes Level 1 moisture reflow preconditioning (24hr +125C bake, 168hr 85C/85%RH moisture soak, and 3 solder reflow passes +240 +0/-5C peak) followed by 1000hr max VCC biased 125C HTOL, 1000 temperature cycles at -55C to +125C, 96hr 130C/85%RH/5.5V HAST and 168hr 121C/2 ATM Steam/Unbiased Autoclave. Figure 5. MASTER FREQUENCY TEMPERATURE VARIATION MASTER FREQUENCY TEMPERATURE VARIATION 2.00 FREQUENCY % CHANGE FROM 25C 1.50 1.00 0.50 0.00 -0.50 -1.00 -1.50 -2.00 33 41.25 49.5 57.75 MAST ER OSCILLAT OR FREQUENCY (MHz) 19 of 21 66 DS1085L TYPICAL OPERATING CHARACTERISTICS (VCC = 3.3V 10%, TA = 0C to +70C.) SUPPLY CURRENT vs. TEMPERATURE SUPPLY CURRENT vs. VOLTAGE 20 14.0 18 12.0 16 CURRENT (mA) CURRENT (mA) 14 12 10 8 10.0 8.0 6.0 DS1085L-05 6 4.0 DS1085L-12 4 2.0 DS1085L-25 DS1085L-12 2 0.0 2.75 0 0 10 20 30 40 50 60 70 3.00 3.25 3.50 VOLTAGE (V) T EMPERAT URE (C) SUPPLY CURRENT vs. DIVISOR SUPPLY CURRENT vs. DIVISOR 12 14 12 11 10 DS1085L-05 6 4 2.75V 3.3V 2 70C 10 8 CURRENT (mA) CURRENT (mA) DS1085L-05 0C 9 8 3.6V 0 0 200 400 600 800 7 1000 DIVISOR (N) 6 0 200 400 600 DIVISOR (N) 20 of 21 800 1000 DS1085L TYPICAL OPERATING CHARACTERISTICS (continued) (VCC = 3.3V 10%, TA = 0C to +70C.) SUPPLY CURRENT vs. DIVISOR SUPPLY CURRENT vs. DAC SETTING AND OFFSET 10 9 14 8 12 7 CURRENT (mA) CURRENT (mA) 10 8 6 OS 4 5 4 DS1085L-25 3 OS+1 DS1085L-12 DS1085L-05 2 OS-1 2 6 1 0 0 200 400 600 800 0 1000 0 DAC SETTING 200 400 600 800 1000 DIVISOR (N) FREQUENCY % CHANGE vs. SUPPLY VOLTAGE FREQUENCY % CHANGE vs. TEMPERATURE DS1085L-12 1.5 DS1085L-05 FREQUENCY % CHANGE FROM 25C FREQUENCY % CHANGE FROM 3.0V 1.0 2.0 1.0 0.5 0.0 0.6 0.4 0.2 0.0 -0.2 -0.5 -0.4 -1.0 -0.6 -1.5 -2.0 2.70 0.8 -0.8 -1.0 2.95 3.20 3.45 0 VOLTAGE (V) 10 20 30 40 50 TEMPERATURE (C) 21 of 21 60 70