Digital Fiber Sensors
E3X-DA-S
Perfection Transcended!
A Wealth of Advanced Functions
for Easy and Reliable Application
CSM_E3X-DA-S_MDA_DS_E_3_1
The industry's first Power Tuning Function in a digital sensor.
Evolution and Perfection
The next-generation platform for a wide range of sensing
2 3
Large, Easy-to-Read Displays that are clear even from a distance.
Seven convenient display formats.
Stable long-term performance achieved with
OMRON's Auto Power Control (APC) function.
A wide array of Advanced Functions for even more applications.
The same Ease-of-Use as the E3X-DA-N Amplifier.
Environmentally
Friendly design.
Improved Mobile Console.
Patent Pending
Large, Easy-to-Read Displays: Clear Even from a Distance
Incident level
Threshold level
Function Setting
Industry's largest
characters: 6 mm
(like earlier models)
Function numbers
added to function
items.
Settings are now reversible.
Seven Convenient Display Formats
An incident level/threshold display, percentage/threshold display, and large bar graph display
have been added, so you can select the best display method for the application.
Display the peak level when light was brightest and bottom level when light was
dimmest. The digital levels of high-speed objects can be read precisely.
(Refreshing the hold level was changed from a fixed time to synchronizing with
the output, so the peak and bottom hold values can be checked with certainty.)
Threshold
level
Patent Pending
Without workpiece
With workpiece
Transparent workpiece
Incident level
does not change. Incident level changes.
Detection is not possible Incident level Threshold level Incident level Threshold level Bar display
4 5
Industry's First Power Tuning Function in a Digital Sensor.
Settings can be made more simply and confident-
ly with two digital displays. For example, the
threshold value can be changed while reading the
incident level or a setting can be changed while
confirming the setting's function item number.
The displays are large and easy-to-read,
despite the small case.
High-speed mode
Short-distance mode
Standard mode
Long-distance mode
Super-long-distance mode
The best mode for each application was
selected from several power modes.
The Sensor can be used immediately without
setting the mode.
If the incident light level is too high or too low,
just press the Mode key to achieve the optimum
status.
Change the threshold level while read-
ing the incident level.
Verify the difference between the inci-
dent level and threshold level while set-
ting the threshold level.
Check the incident level intuitively. Ideal
when it is better to view an analog dis-
play instead of the actual digital level.
Incident level Peak hold
Simultaneously display the peak hold level and
present incident level. The optical axis can be
adjusted more easily and surely by checking the
peak hold level while adjusting the optical axis.
Incident Level/Threshold Display Percentage/Threshold Display Large Bar Graph Display
Detecting missing tablets
RUN mode
SET mode
Incident Level/Peak Hold Display Peak Hold/Bottom Hold Display
1350 1280
2010 2055
Incident level
Threshold level
Press
Press
Earlier Method New Method
Earlier Method New Method
Large, bright
operation indicator
(like earlier models)
Power tuning indicator added
to indicate setting status.
No power modes
Up to 1/25 reduction
Up to 5-fold increase
Detection is possible.
Press
No incident light
Incident light
No complicated mode settings.
Troublesome power adjustments have been eliminated, so it isn't necessary
to select from power mode settings, such as long-distance mode, standard
mode, and short-distance mode. When the MODE Key is pressed once, the
power tuning function shifts the power level so that the present incident level
is set to the ideal level (2000 on the digital display.)
Insufficient light or saturation at short distances can be corrected.
The power tuning range is extended to the allowable limits to eliminate prob-
lems such as insufficient light or detection failures due to saturation.
If the installation distance is too short, the incident light may saturate (i.e., to
a digital incident level of 4,000), preventing detection. The power can be
tuned down to 1/25th of the default setting for stable detection even at close
range.
Variations between different Sensors can be eliminated.
Threshold levels had to be set and maintained separately for individual Sen-
sors due to variations in the digital light levels measured by each Sensor.
With power tuning, the incident level can be fine-tuned so the same thresh-
old level can be set for each Sensor in an application. Maintenance is also
simplified because it is easier to recognize measurement levels that have
shifted during operation.
Appropriate
Appropriate
Saturated
Saturated
Incident
insufficient
Digital light levels vary due to individual
differences in the Sensors, so the
threshold levels must be set individually.
All of the Amplifiers are set to the same digi-
tal light level, so the same threshold level
can be set and maintained for the Sensors.
In addition to our unique APC circuit used in the
E3X-DA-N Amplifiers to compensate for the dete-
rioration of the LED, the E3X-DA-S uses 4-ele-
ment LEDs to counteract the deterioration of the
light-emitting elements over time and achieve the
industry's most stable long-term detection perfor-
mance.
Furthermore, the circuit is designed with excess
light capacity, so the Sensors can be used with
high stability regardless of whether the APC cir-
cuit is ON or OFF.
With the Twin-output Amplifiers, output 2 can function as an
alarm output (light level operation) to indicate when the light
level has changed due to dirt or other causes.
Time
Time
OMRON provides the industry's most stable long-term detection
by using new 4-element LEDs and an APC (Auto Power Control) circuit.
Time
Without APC circuit Without APC circuit
3-element LED and APC 4-element LED and APC
Earlier Method New Method
Time
Light Level Operation
(Normal Operation)
Judges light level changes by comparing
the incident level and threshold level.
Differential Operation
Judges light level changes by comparing the
incident level to a time-averaged incident level.
Threshold level
(absolute value)
Light level difference
(absolute value)
Incorrect operation due to light level change
The light level varies due to dirt, temperature
variations, or other environmental factors.
Detecting differences in the light level enables
setting more subtle light level differences.
Incident
level
Incident
level
Output
ON
OFF
Time
Time
2000
1000
Threshold 1
Threshold 2
The counter function can output signal after counter
counts up or down.
(Advanced External-input Models)
Counter Function
Highest Level of Stability
Stable, Long-term Performance with OMRON's APC Function Many Advanced Functions for Even More Applications
Patent Pending
Patent Pending
Incorrect operation Minute changes are
detected reliably.
Area output function can be
used for range judgement.
(Advanced Twin-output Models)
Remote input function can control the Sensor remotely.
(Advanced External-input Models)
Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times.
Operations that required multiple Sensors, such as
height measurement, can be performed with just one
Sensor. Two threshold levels can be set to easily output
within-range and out-of-range outputs.
A counter function is built-in, so the number
of workpieces can be counted without a sep-
arate counter or small PLC that used to be
required.
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter
OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation
or making settings remotely because teaching has to be performed often for frequent workpiece model
changes.
Fastest in the Industry
Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s.
A one-shot timer is supported in addition to the ON-delay and OFF-delay timers.
The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection.
Discriminating Tablet Lengths
Detecting Seals
Detecting Leads on Electronic Parts
Detecting Chip Components
6 7
This operation mode uses a special OMRON algorithm to compensate for slight light level changes
due to dirt or temperature variations and detect only the light level changes due to the workpiece.
Area output
Incident
level
Time
Counter
Time
Up Counter Down Counter
Counter
Counter
value
Time
Threshold
level
Output when count reaches SV. Output when count reaches 0.
Alarm output
threshold
Alarm output
Long-term stability
Slight light level changes can be detected with stability and
precision, eliminating the need for time-consuming manual ad-
justments for light level changes.
Compensate for the effects of contaminants and temperature variation
with differential operation mode. (Advanced Models)
Incident level
Incident level
Incident level
Incident level
Detecting marks in a dusty environment
Detecting knots in thread
This ECO label is indicated on produts
that meet the environmental standards
established by OMRON.
First in the industry
Optical
communi-
cations
Up to 10 Amplifiers
Display reset to 0.
Incident level
difference = 700
Threshold level
set to 350.
Selectable
Standard mode
Reverse mode
Environmentally friendly features are
essential in truly high-performance products.
During operation
(After 30 s without
an operation)
During operation
(After 30 s without
an operation)
Lights up if an
operation is
performed.
Display not lit. Dimmed display
Cable disposal is not necessary.
Eco-mode
Simplified Connector Design
Reduced Power Wiring Saves Space
Patent Pending
Power supply pin
Optical
commun-
ications
Up to 16 Amplifiers can be connected.
Relay connectors
Relay connectors
not required.
<Using 5 Amplifiers>
Connector models
Prewired models Eliminate the installation time, cost, and
space associated with relay connectors.
Streamlined
wiring
7 cables
Japan patent number 3266198
Lights up if an
operation is
performed.
The Same Ease-of-Use as the E3X-DA-N Environmentally Friendly Design
8 9
Wiring time is significantly reduced.
Relay connectors are unnecessary, so wiring takes up less space.
Storage and maintenance are simpler because it isn't necessary to distin-
guish between master connector and slave connectors on the Amplifier.
1.
2.
3.
Zero reset
Zero reset
Zero reset
Master connector
Slave connector
Close-mounting of up to 10 Sensors
Shift
Shift
Shift
Pb
In Amplifiers with Connectors, the power supply is dis-
tributed to slave connectors through a single master
connector. This design has three major advantages.
Reversible Digital Display (Reverse Mode)
The digital display can be reversed to match the
Amplifier's mounting direction.
Zero reset function immediately
resets the digital display to 0.
The zero reset function can immediately reset the
digital display to 0 at any time. By setting the ref-
erence value to 0, the threshold value can be set
while monitoring differences in incident light lev-
els. The threshold value will also shift simultane-
ously when the zero reset button is pressed.
The E3X-DA-S uses OMRON's own
simplified wiring connectors that
were introduced with the E3X-DA-N.
Patent Pending
Japan patent number 3255229
Output lines only
Power line
Output lines only
Power line
Power is supplied
from the master
Amplifier Unit to
the slave Amplifier
Units through the
Master Connector.
15 cables
Separate power
lines and output
lines are required
for each Amplifier.
Optical communications
prevents mutual interference.
Mutual interference is prevented with optical com-
munications, so up to 10 Amplifiers can be mount-
ed together.
(The number of Amplifiers depends on the operating conditions.)
With Workpiece
Without Workpiece
1
When the digital display is viewed infre-
quently during operation, current con-
sumption can be reduced by dimming the
display or turning it OFF entirely.
The display will light up again automatical-
ly when an operation key is touched. (Eco-
mode can be set from the Mobile Console
only.)
2The digital display can be turned OFF or dimmed during operation.
The Fiber Sensor is the first in the industry
to use environmentally friendly lead-free
solder.
In addition to saving space and reducing
wiring time, the new connector design
eliminates the need to dispose of cables
together with the Amplifiers.
3
Cable disposal is not required during maintenance.
Materials containing lead have been completely eliminated.
No lead!
Group teaching
Group Power Tuning
Operation OK
Operation OK Operation OK
Operation OKLocked
Locked Locked
Locked
Locked
Application
Set for manual operation.
Set for teaching operation.
Set for teaching
+
manual operation.
Function Block
Manual setting Teaching
Function setting
Easily set
multiple Sensors.
New and Improved
Fiber Sensor and
Mobile Console.
The Age of User-
customizable Sensors.
Channel 1
Copy channel 1's
contents to all channels.
All of the group's
settings are copied.
Channel 2 Channel 5
Channel 1 All channels
10 11
Can also be used with Photoelectric Sensors with Separate Digital Amplifiers.
E3C-LDA
Photoelectric Sensor with Separate Digital Amplifier
E3X-MC-S
Mobile Console
E3X-DA-S
Digital Fiber Sensor
Manual
Manual
Teaching
Teaching +
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Further Improvements to the Mobile Console
Group Power Tuning
Improved Mode Lock Function
Retains all of the Previous Advantages of the Mobile Console.
Machine A
Machine B
Machine D
With the group power tuning function, power tuning is possible
for multiple Sensors at the same time.
Settings can be customized for different applications by locking
out unnecessary function blocks within function settings.
Settings, teaching, and fine-tuning
can be performed at the fiber tip.
The Mobile Console can be used for settings and teaching at
the tip of the fiber. Difficult adjustments can be made while
checking the workpiece position.
Even if the Amplifier and Sensor head are separated during
operation, it is still possible to flash the Sensor head and dis-
play the amplifier channels.
With Group Teaching, Teach Multiple
Amplifiers Simultaneously.
The tedious teaching that had to be performed separately for
each Amplifier can now be performed for several Amplifiers at
once using the Mobile Console.
Copying Settings within the Same Group
Settings such as mode or threshold settings in an Amplifier or
bank can be copied to all of the Amplifiers in the same group.
Copying Settings to Other Groups
The settings for a group of Amplifiers on one machine can be
copied to a group of Amplifiers on another machine.
(The settings can also be copied to and from banks.)
Authorized Distributor:
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
CSM_E3X-DA-S_MDA_DS_E_3_1
In the interest of product improvement, specifications are
subject to change without notice.
This document provides information mainly for selecting
suitable models. Please read the Instruction Sheet
carefully for information that the user must understand
and accept before purchase, including information on
warranty, limitations of liability, and precautions.
E3X-MDA
Super Dual Fiber Sensor
Bringing a new dimension to sensing…
…the 2-channel amplifier has arrived.
Authorized Distributor:
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022
Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit, Carl-Benz-Str. 4,
D-71154 Nufringen, Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, #11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Road (M),
Shanghai, 200120 China
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
In the interest of product improvement, specifications are subject to change without notice.
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including
information on warranty, limitations of liability, and precautions.
CSM_E3X-DA-S_MDA_DS_E_3_1
CSM_E3X-DA-S_MDA_DS_E_3_1
Slimmest in the industry — 5 mm per channel.
Checking alignment and mounting
of LCD substrates
Detection and front/back
discrimination of parts
Detection of bends in electronic
component leads
Patent pending
Compact PLC
or
Sensor Controller
AND/OR AND/OR
1 ch
2 ch Emitting
Receiving
Emitting
Receiving
10 mm
Two Amplifiers squeezed into a body of width
10 mm.
Remarkable space saving of approx. 50%.
Power saving of approx. 40%.
(Savings per channel compared with
existing products.)
Equipped with AND/OR control output. Patent pending
Two types of control output possible with one
Sensor (AND/OR).
Compact PLCs and Sensor Controllers no
longer required.
Flexible control with Mobile Console.
The Mobile Console, which can also be used with the E3X-DA-S,
allows handheld operation of the Fiber Head even when it is
separated from the Amplifier.
Having problems gang-mounting Fiber Sensor Amplifier Units
in tight spaces?
50 mm
100 mm
Half the Space
Incident level
Operation
indicator Channel 1
display
Channel 2
display
Incident level
Operation
indicator
A host of remarkable functions inside a compact body.
A complete lineup of Sensor Heads to handle an even wider
range of applications.
This is the platform for OMRON's sensing technology.
A lineup of Smart Sensors that use
the eddy current method
An improved lineup for smarter sensing
Refinement and a new dimension that
goes beyond superior performance.
Photoelectric Sensors with Separate
Digital Amplifiers have joined the Smart
Sensor family.
High-resolution sensing using laser
and magnetic technology
A common platform for Fiber Sensors
and Sensors with Separate Amplifiers
Laser-type Smart Sensors
ZX-L Series
Inductive Displacement
Smart Sensors
ZX-E Series
Digital Fiber Sensors
E3X-DA-S/MDA Series
Laser-type Photoelectric Sensors
with Separate Amplifiers
E3C-LDA Series
Linear Platform
ON/OFF Platform
Smart Monitor
Mobile Console
Models with Cables
Models with Green LED
Models with Blue LED
Infrared Models
An impressive lineup of Digital Amplifiers to
handle a wide variety of applications.
Standard Models
Models with Connectors
Equipped with OMRON's own easy-wiring connector.
External-input Models
The Sensor can be controlled externally. Equipped with counting function.
(E3X-MC11-S)
(E3X-DA11-S)
(E3X-DA6-S)
(Representative model:
E3X-DAG6-S)
(Representative model:E3X-DAB6-S)
(Representative model:E3X-DAH6-S)
(Representative model:E3X-MDA6)
(Representative model: E3X-DA6TW-S)
The Digital Amplifiers achieve a maximum response time of 48 µs.
Twin-output Models
Two threshold values can be set. Judgement and self-diagnosis
output available.
Advanced Models
Available Soon
Mark-detecting Models and Infrared Models
2-channel Models
Mobile Console
(Representative model:
E3X-DA6RM-S)
A wide variety of color variations available. Equipped
with APC circuit for more stable detection.
NEW Two Amplifiers squeezed into a single, compact Unit.
AND/OR output available.
Maximize Fiber Amplifier potential using remote setting,
copying, and other functionality.
New Models That Counteract the Decline
in Operating Rates Caused by Dust and Dirt
A unique OMRON algorithm has been used that can determine whether
changes have been caused by dust and dirt or by differences in
workpieces.
The threshold value is automatically adjusted by the Sensor according
to changes to increase equipment operating rates by reducing sensing
errors. This is particularly true in applications requiring high-precision
detection.
OMRON's many years of accumulated sensing technology and high-
speed digital processing techniques merge to meet onsite needs. Our
goal is high-performance sensing that provides easy, reliable application.
Active Threshold Control (ATC)
Automatically adjusts the threshold value.
ATC Error Output (Selectable Function)
Provides an error output when ATC does not adjust
the threshold value.
Alarm Output (Selectable Function)
Provides an alarm when maintenance is required.
Digital Laser Sensors
E3C-LDA@AT
Digital Fiber Sensors
E3X-DA@AT- S
Glass substrate detection though
view ports
Chip component detection
Fixed Threshold Value (Previous Models)
2000
Digital incident
level
ON
Output OFF
ON
Output OFF
Active Threshold Control (ATC Models)
2000 10%
The value of the threshold is
adjusted every 30 s (see note) to prevent sensing errors.
A relative value
is set for the threshold.
Time
1800
Time
An absolute value
is set for the threshold.
Adjustment is required for sensing errors.
The monitoring range is set in the Sensor according to the thresh-
old value. The threshold value is adjusted according to changes
within this range.
Advanced ATC Models
Sensing Engine
The Engine for High-performance
Sensing
Intelligently Solve Problems Onsite with
ATC Function
Automatic Compensation for
External Changes
Active Threshold Control (ATC)
Easy-to-read Displays Even at a Distance
Intelligent Display
Fine Sensing
High Performance
Easy Operation
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution),
high-speed response of 48 µs (Fiber Sensors)
Technology
Digital incident
level
Consistent Emitter Power
Auto Power Control (APC)
Eliminates the Need for Distance Mode Settings
Power Tuning
CSM_E3X-DA-S_MDA_DS_E_3_1
Ordering Information
Ratings and Specifications
NPN output PNP output
E3X-DA41AT-S
E3X-DA41AT-S
E3X-DA8AT-S
E3C-LDA41AT
E3X-DA11AT-S
E3X-DA11AT-S
E3X-DA6AT-S
E3C-LDA11AT
E3X-DA8AT-S E3C-LDA8AT
E3X-DA6AT-S E3C-LDA6AT
Pre-wired Models AT C
ATC error output
Alarm output
AT C
ATC error output
Alarm output
Connector Models
Type
Digital Fiber Sensor
Separate Digital Amplifier Laser Sensors
Appearance Model
E3C-LDA41AT
E3C-LDA8AT
E3C-LDA11AT
E3C-LDA6AT
Pre-wired Models
Connector Models
Type Appearance
Functions
Item
Type
Model Digital Fiber Sensors Separate Digital Amplifier Laser Sensors
NPN output
PNP output
Response
time
Functions
Operate or Reset: 80 µs Operate or Reset: 100 µs
Operate or Reset: 250 µs
Operate or Reset: 1 ms
Operate or Reset: 4 ms
Active threshold control (used for output 1)
The signal that is output can be selected (used for output 2): ATC error output
The operation when power is turned ON can be selected: No operation, PT, or PT + ATC
Super-high-speed mode
High-speed mode
Standard mode
High-resolution mode
AT C
I/O settings
Startup operation
Basic performance is the same as the Advanced Twin-output Sensors. Refer to E3C-LDA Datasheet (E338) and E3X-DA-S Datasheet (E336) for details.
Only differences from the Advanced Twin-output Sensors have been given above.
Model
PNP outputNPN output
Functions
Operate or Reset: 250 µs
Note:
Authorized Distributor:
Note: Specifications subject to change without notice.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
CSM_E3X-DA-S_MDA_DS_E_3_1
New Models That Eliminate Worries about
Digital Sensor Setting Mistakes
One-key, one-operation concept for easy operation.
Threshold value setting with direct operation performed
while monitoring the detection status.
Lock function to prevent operating errors through
unintentional operation.
Technology
Digital Fiber Sensors
E3X-DA@SE-S
Easy and Reliable Digital Sensors
with the Same Detection Performance
as Previous Models
Limited-function Models: Simple and Easy
Some people think that digital sensors with their advanced performance
are difficult to use, so we went back to the drawing board to rethink per-
formance and functions.
Without changing basic functions like APC and digital displays, OMRON
created a Digital Fiber Sensor that can be used as easily as the familiar
sensors with sensitivity adjustment knobs.
OMRON's many years of accumulated sensing technology and high-
speed digital processing techniques merge to meet onsite needs.
Our goal is high-performance sensing that provides easy, reliable
application.
Incident level Threshold value
KEY LOCK Switch
OPERATION MODE Selector
Threshold adjustment
Threshold Teaching
With/Without Workpiece: Teaching is performed in two states.
Automatic: Teaching is performed by passing a workpiece.
UP/DOWN Key
TEACH Key
The Engine for High-performance
Sensing
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution)
Sensing Engine
Consistent Emitter Power
Auto Power Control (APC)
Easy-to-read Displays Even at a Distance
Intelligent Display
Fine Sensing
High Performance
Easy Operation
The Simplest Digital Fiber Sensor
One Key, One Operation
Simple and easy direct operation
CSM_E3X-DA-S_MDA_DS_E_3_1
Ordering Information
Ratings and Specifications
NPN
out
p
u
t
PNP
out
p
u
t
E3
X-DA41
S
E-
S
E3X-DA41
S
E-
S
E
3X-DA8SE-S
E
3X-DA8
S
E-
S
E3
X-DA11
S
E-
S
E3X-DA11
S
E-
S
E
3X-DA6SE-
S
E
3X-DA6
S
E-
S
re-wired Models
Connector Models
Ty
pe
A
ppearance
M
o
del
I
t
em
T
yp
e
M
o
del
Di
g
ital Fiber
S
enso
r
NPN out
p
ut
PNP
out
p
ut
Light source
(
wavelength
)
Power supply volta
ge
Power consumption
C
ontrol outpu
t
P
rot
ec
t
i
on
ci
r
cui
t
s
R
es
p
onse t
i
m
e
Sensitivity setting
Fu
n
c
t
i
on
s
A
uto
p
ower
control
M
utual interference
p
reventio
n
I
ndicator
s
Di
g
i
ta
l
di
sp
l
ay
s
Red LED
(
650 nm
)
1
2 to 24 VD
C
±
10%, ri
pp
le
(p
-
p)
: 10% max
.
960 mW max. (Power suppl
y
: 24 V,
C
urrent consumption: 40 mA max.)
L
oad power supply: 26.4 VDC max., Open-collector output, Load current: 50 mA max. (Residual volta
g
e: 1 V max.)
Power supply reverse polarity protection, Output short-circuit protection
O
perate or Reset: 1 ms
Teachin
g
or manual adjustmen
t
High-speed control method for emission current
Optical communications s
y
nc, possible for up to 10 Units
O
peration indicator (oran
g
e)
Twin di
g
ital displays (incident level + threshold
)
Basic
p
erformance is the same as the E3X-DA-S Series. Refer to the E3X-DA-S Datasheet
(
E336
)
for details.
N
ote:
Authorized Distributor:
Note: Specifications subject to change without notice.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
CSM_E3X-DA-S_MDA_DS_E_3_1
1
CSM_E3X-DA-S_MDA_DS_E_3_1
Digital Fiber Sensors
E3X-DA-S/MDA
OMRON’s Next-generation Platform
for a Wide Range of Detection
Features a Power Tuning function that optimizes light reception at
the press of a button.
Combines newly de veloped 4-element LEDs with an APC circuit to
ensure stable, long-term LED performa nce.
Utilizes OMRON’s innovative wire-saving connector.
2-channel models achiev e the thinnest profile in the industry, at only
5 mm per channel.
2-channel models also offer AND/OR control output.
Be sure to read Safety Precautions on
page 15.
Features
Equipped with an Industry’s First Power Tuning (Optimum Light Setting) Function
The E3X-DA-S/MDA features a Power Tuning function that optimizes
power at the press of a button.
This function easily but securely resolves saturation due to short
sensing distances or insufficient incident light due to long sensing
distances.
In addition, the response speed does not change as mode selection
has tuned the power.
Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit
Achieves Long-term Reliable Detection at the Highest Level in the Industry
The long-term reliable detection at the highest level in the industry is
achieved with the innovative APC circuit whose performance is
proved by E3X-DA-N series and the newly developed high-power
LEDs (4-element type) to ensure super stable, long-term LED
performance.
Stable performance is always available without the ON/OFF setting of
an APC circuit.
OMRON’s Innovative Wire-saving Connector Inherited from the E3X-DA-N
The amplifier units with connectors sup ply the power to slave
connectors via a master connector. This offers three following
advantages.
Selected from various
power mode according to applications
Up to approx. 1/25 times
Up to approx.
5 times
Incident
level Low
Appropriate
Incident level
Threshold
Saturation
Saturation
High-speed mode
Short-range mode
Standard mode
Long-range mode
Super-long-range mode
Appropriate
Modeless
Press
Available without mode setting.
Press the MODE key once to
adjust high or low incident levels
to be appropriate.
Conventional New proposal
Conventional Newly developed
Time
No APC circuit No APC circuit
3-element LEDs + APC
4-element LEDs + APC
Incident level
Incident level
Time
Long-term
stability
1. Greatly reduced wiring work
2. Improved space usability due to the unnecessity of relay
connectors
3. Simple stock management due to the unnecessity of
distinction between master and slave for amplifiers
Wire-saving Connector Model
Reduced Wiring and Space Requirements for Power Lines
Optical
communications
Power supply pin
Relay connector
Relay connector installation work, cost and space are saved.
No relay connector required
Amplifier units with connectors
Amplifier units with cables
<When using 5 amplifier units>
The power is
supplied from a
master unit to
slave units via a
master connector.
Power and output
lines are required
respectively.
Up to 16 amplifier units connectable
Master connector
Slave connector
Only output lines
Power line
Output lines
Power lines
Clear 7 lines
15 lines
E3X-DA-S/MDA
2
Industry Leading Two Amplifiers Loaded in a Small Body
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of th e energy can be
saved.
(compared to the value per channel of the former
model)
Simpler Digital Fiber Sensors
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the se nse as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
High-speed and High-resolution Analog Output Supports Wide Variety of Applications
Analog Control Output
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
High-speed and High Resolution
Detection modes can be switched in accordance with applications.
High-speed response of 80 µs (super-high-speed mode) supports the
positioning controls that require high-speed control.
Area Output Function Area Judgment Is
Possible
Only one sensor is enough for area judgment for height or others that
has required multiple sensors.
Setting two threshold values allows easy output inside and outside
range.
Remote Input Function Sensors Controlled from Outside
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites
OMRON’s unique algorithm is equipped to
distinguish dust or dirt and the change of
workpieces. Automatic correction of threshold
values by sensors in accordance with changes
prevents malfunctions and improves the
operating rates of machines. The ATC function
is especially effective for the applications that
require high-resolution detection.
Models available for a wide variety of applications at manufacturing sites
. . . . 2-channel models
Liquid crystal board installation and alignment check
20mm 10mm
2-channel models
E3X-MDA
Current value Threshold value
Key lock switch
Operation mode
selection switch
Threshold value adjustment
Threshold value teaching
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
UP/DOWN keys
TEACH key
. . . . Simple & Easy Single-function Models
. . . .Advanced Analog
Output Models
ON/OFF
Analog
Sheet Displacement
. . . .Advanced, Twin-output Models Area Output Tablet length detection
2000
1000
Threshold
value 1
Threshold
value 2
Output
ON
OFF
Incident
level
Time
Sticker detection
. . . .Advanced, External-
input Models
. . . .Advanced ATC Models
Fixed Threshold Value Method (Conventional Models)
2000
Incident level
(digital value)
Incident level
(digital value)
ON
Output OFF
ON
Output OFF
Corrected Threshold Value Method (ATC Models)
2000 10%
Threshold value is corrected every 30 seconds
*
Malfunctions are prevented
Threshold value
set as a relative
value
Time
1800
Time
Threshold value
set as an
absolute value
Malfunction Adjustment is required
* Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.
E3X-DA-S/MDA
3
Ordering Information
Amplifier Units
Amplifier Units with Cables (2 m) [Refer to Dimensions on page 17.]
Amplifier Units with Connectors
Ratings and Specifications
Item Appearance Functions Model
NPN output PNP output
Single-function models --- E3X-DA11SE-S 2M E3X-DA41SE-S 2M
Standard models
Timer, Response speed change
E3X-DA11-S 2M E3X-DA41-S 2M
Mark-detecting models
(multiple color light sources)
Green LED E3X-DAG11-S 2M E3X-DAG41-S 2M
Blue LED E3X-DAB11-S 2M E3X-DAB41-S 2M
Infrared LED E3X-DAH11-S 2M E3X-DAH41-S 2M
Advanced m od e l s
External-input
models Remote setting, counter, differential oper-
ation E3X-DA11RM-S 2M E3X-DA41RM-S 2M
Twin-output
models Area output, self-diagnosis, differential
operation E3X-DA11TW-S 2M E3X-DA41TW-S 2M
ATC function
models ATC (Threshold value automatic correc-
tion) E3X-DA11AT-S 2M E3X-DA41AT-S 2M
Analog output
models Analog output models E3X-DA11AN-S 2M E3X-DA41AN-S 2M
2-channel models AND/OR output E3X-MDA11 2M E3X-MDA41 2M
Item Appearance Functions Model
NPN output PNP output
Single-function models --- E3X-DA6SE-S E3X-DA8SE-S
Standard models
Timer, Response speed change
E3X-DA6-S E3X-DA8-S
Mark-detecting models
(multiple color light sources)
Green LED E3X-DAG6-S E3X-DAG8-S
Blue LED E3X-DAB6-S E3X-DAB8-S
Infrared LED E3X-DAH6-S E3X-DAH8-S
Advanced m od e l s
External-input
models Remote setting, counter, differential op-
eration E3X-DA6RM-S E3X-DA8RM-S
Twin-output
models Area output, self-diagnosis, differentia l
operation E3X-DA6TW-S E3X-DA8TW-S
ATC function
models ATC (Threshold value automatic correc-
tion) E3X-DA6AT-S E3X-DA8AT-S
2-channel models AND/OR output E3X-MDA6 E3X-MDA8
Light source Response
time
Control output/input Functions
ON/OFF
output Input Analog
output Power
tuning Timer Interfer-
ence pre-
vention
Differen-
tial detec-
tion counter ATC
Single-function models Red LED 1 ms Only
main --- --- --- --- --- --- ---
Standard models 50 µs to
4ms
Mark-
detecting
models
E3X-DA@G-S Green LED 50 µs to
4ms Only
main --- --- --- --- ---3X-DA@B-S Blue LED
E3X-DA@H-S Infrared LED
Ad-
vanced
models
Twin-output
models
Red LED
50 µs to
4ms Only
main
(1 line)
--- ---
External-input
models 80 µs to
4ms Main +
sub
(2 lines) --- ---
ATC function
models 130 µs to
4ms
Analog output 80 µs to
4ms Only
main
(1 line) --- ---
2-channel models Red LED 130 µs to
4ms
Main +
main
(2 inde-
pendent
lines)
--- --- --- --- ---
E3X-DA-S/MDA
4
Amplifier Unit Connectors (Order Separately)
Note: Protector seals are provided as accesso r ie s . [Refer to Dimensions on page 19.]
Mobile Console (Order Separately) [Refer to Dimensions on page 20.]
Note: Use the E3X-MC11-SV2 Mobile Consol e for the E3X-DA-S/MDA-series Amplifier Units.
The E3X-MC11-SV2 is an upgraded versi on of the E3X-MC11-S that is fully interchangeable with the older model.
Accessories (Order Separately)
Mounting Bracket [Refer to E39-L/F39-L/E39-S/E39-R.] End Plate [Refer to PFP-
@
.]
Item Appearance Cable
length No. of con-
ductors Model
Master Connector
2 m
3E3X-CN11
4E3X-CN21
Slave Connector 1E3X-CN12
2E3X-CN22
Appearance Model Remarks
E3X-MC11-SV2
(model number of set)
Mobile Console with Head,
Cable, and AC adapter pro-
vided as accessories
E3X-MC11-C1-SV2 Mobile Console
E3X-MC11-H1 Head
E39-Z12-1 Cable (1.5 m)
Combining Amplifier Units and Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
When Using 5 Amplifier Units
Amplifier Unit Applicable Connector (Order Separa tely)
Model NPN output PNP output Master Connector Slave Connector
Single-fun ction models E3X-DA6SE-S E3X-DA8SE-S
+ E3X-CN11 E3X-CN12
Standard models E3X-DA6-S E3X-DA8-S
Mark-detecting models
(multiple color light
sources)
E3X-DAG6-S E3X-DAG8-S
E3X-DAB6-S E3X-DAB8-S
E3X-DAH6-S E3X-DAH8-S
Advanced models E3X-DA6TW-S E3X-DA8TW-S
E3X-CN21 E3X-CN22
E3X-DA6RM-S E3X-DA8RM-S
E3X-DA6AT-S E3X-DA8AT-S
2-channel models E3X-MDA6 E3X-MDA8
Amplifier Units (5 Units) + 1 Master Connector + 4 Slave Connectors
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
E3X-DA-S/MDA
5
Ratings and Specifications Refer to pages 17 to 20 for dimensions.
Amplifier Units
*1. Communications are disabled if the detection mode is selected duri ng super-high-speed mode, and the communications functions for mutual interf erence prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*3. Mutual interference prevention can be used for only up to 6 Unit s if power tuning is enabled.
Type Single-function
models Standard
models Mark-detecting models (multiple color light sources)
Green LED Blue LED Infrared LED
Item Model E3X-DA@SE-S E3X-DA@-S E3X-DAG@-S E3X-DAB@-S E3X-DAH@-S
Light source (wavelength) Red LED (635 nm) Green LED (525 nm) Blue LED (470 nm) Infrared LED
(870nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Protection circuits Reverse polarity for power supply connection, output short-circuit
Re-
sponse
time
Super-high-
speed mode --- Operate: 48 µs, reset: 50 µs *1, *2
High-speed
mode --- Operate/reset: 250 µs
Standard mode Operate or reset: 1 ms
High-resolution
mode --- Operate or reset: 4 ms
Sensitivity setting Teaching or manual method
Func-
tions
Power tuning --- Light emission power and reception gain, digital control method
Timer function --- Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
control (APC) High-speed control method for emission current
Zero-reset --- Negative values can be displayed. (Threshold value is shifted.)
Initial reset Settings can be returned to defaults as required.
Mutual interfer-
ence prevention Possible for up to 10 Units *3
Display Operation indicator
(orange) Operation indicator (orange), Power Tuning indicator (orange)
Digital display incident level +
threshold Select from incident level + threshold or other 6 patterns
Display orientation --- Switching between normal/reversed display is possible.
Ambient illumination
(Receiver side) Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature range Operating:Groups of 1 to 2 Amplifiers: 25°C to 55°C
Groups of 3 to 10 Amplifiers: 25°C to 50°C
Groups of 11 to 16 Amplifiers: 25°C to 45°C
Storage: 30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired or amplifier unit connector
Weight (packed state) Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction manual
E3X-DA-S/MDA
6
*1. Input Specifications
*2. Communications are disabled if the dete ction mode is selected du ring super-high-speed mode, and t he communications functions for mut ual interference prevention
and the Mobile Console will not function.
*3. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*4. When counter is enabled: 80 µs for operate and reset respectively.
*5. When differential output is selected for the output setting, the second channel output is 200 µs for operation and reset respecti vely.
*6. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*7. Mutual interference prevention can be used for up to 5 Units (10 channels) if powe r tuning is enabled.
Type Advanced models 2-channel models
External input mod-
els Twin output mod-
els ATC function mod-
els Analog output mod-
els
Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@
Light source (wavelength) Red LED (635 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Con-
trol
output
ON/OFF output Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Analog output ---
Control output
Voltage output: 1 to
5VDC
(Connection load
10 k min.)
Temperature charac-
teristics
0.3%F.S./°C
Response speed/re-
peat accuracy
Super-high-speed
mode:
80 µs/1.5%F.S.
High-speed mode:
250 µs/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
---
Remote control input No-voltage input (contact/non-contact) *1
Protection circuits Reverse polarity for power supply connection, output short-circuit
Re-
sponse
time
Super-high-
speed mode Operate: 48 µs,
reset: 50 µs *2, *3, *4Operate or reset:
80 µs *2Operate or reset:
130 µs *2Operate or reset:
80 µs *2Operate or reset:
130 µs *2, *5
High-speed
mode Operate or reset: 250 µsOperate or reset:
450 µs
Standard mode Operate or reset: 1ms
High-resolution
mode Operate or reset: 4ms
Sensitivity setting Teaching or manual method
Func-
tions
Power tuning Light emission power and reception gain, digital control method
Differential de-
tection
Switchable between single edge and double edge detection mode
Single edge: Can be set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms. ---
Timer function Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1 s-increments)
Automatic pow-
er control (APC) High-speed control method for emission current
Zero-reset Negative values can be displayed. (Threshold value is shifted.)
Initial reset Settings can be returned to defaults as required.
Mutual interfer-
ence prevention Possible for up to 10 Units *6Possible for up to 9
Units (18 channels) *7
Counter
Switchable between
up counter and down
counter.
Set count:
0 to 9,999,999
---
Contact input (relay or switch) Non-contact input (transistor)
NPN ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc. ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
PNP ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V. ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
E3X-DA-S/MDA
7
Type Advanced models 2-channel models
External input
models Twin-output mod-
els ATC function mod-
els Analog output
models
Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@
Func-
tions I/O setting
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
Analog output set-
ting (offset voltage
adjustable)
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Display
Operation indicator
(orange), Power
Tuning indicator (or-
ange)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Operation indicator
(orange),
Power Tuning indi-
cator (orange)
Operation indicator
for channel 1 (or-
ange), Operation in-
dicator for channel 2
(orange)
Digital display Select from incident
level + threshold or
other 7 patterns Select from incident level + threshold or other 6 patterns
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
Display orientation Switching between normal/reversed display is possible.
Ambient illumination
(Receiver side) Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature range
Operating: Groups of 1 to 2 Amplifiers: 25°C to 55°C
Groups of 3 to 10 Amplifiers: 25°C to 50°C
Groups of 11 to 16 Amplifiers: 25°C to 45°C
Storage: 30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired or amplifier unit connector
Weight (packed state) Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction manual
Amplifier Unit Connectors
Item Model E3X-CN11/21/22 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact re sistance 20 m max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent Connec-
tor. It does not include the conductor resistance of the cable.)
No. of insertions Destructio n: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Mate-
rials Housing Polyb u tylene terephthala te (PB T )
Contacts Phosphor bronze/gold-plated nickel
Weight
(packed state) Approx. 55 g Approx. 25 g
Mobile Console
Item Model E3X-MC11-SV2
Applicable
Sensors
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Power supply
voltage Charged with AC adapter
Connection
method Connected via adapter
Weight
(packed state) Approx. 580 g (Console
only: 120 g)
Refer to Instruction Manual provided with
the Mobile Console for details.
E3X-DA-S/MDA
8
Sensing Distance
Through-beam Models (Unit: mm)
*1. The optical fiber for t he E32-T17L is 10 m long on each side, so the value is 20,000 mm
*2. The optical fiber is 2 m long on each side, so the sensing di stance is 4,000 mm.
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Standard
models
Flexible
(new
standard)
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R) 700 530 350 140 450 350 230 140
E32-T14LR/E32-T15YR/E32-T15ZR 270 210 130 50 170 130 85 50
E32-T21R/E32-T22R/E32-T222R/
E32-T25XR/E32-TC200FR(F4R) 160 130 75 30 100 75 50 30
E32-T24R/E32-T25YR/E32-T25ZR 60 50 25 10 35 27 18 10
Standard
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4) 1,000 760 500 200 650 500 330 200
E32-T14L/E32-T15Y/E32-T15Z 600 460 300 120 390 300 200 120
E32-TC200A 900 680 450 180 580 450 300 180
E32-TC200E/E32-T22/E32-T222/
E32-T25X/E32-TC200F(F4) 270 220 125 50 170 130 85 50
E32-T24/E32-T25Y/E32-T25Z 160 130 75 30 100 70 45 30
Break-
resistant
E32-T11/E32-T12B/E32-T15XB 900 680 450 180 580 450 300 180
E32-T21/E32-T221B/E32-T22B 240 200 110 45 150 110 70 45
E32-T25XB 180 150 85 35 125 95 60 35
Fluorine
coating E32-T11U 900 680 450 180 580 450 300 180
Special-
beam
models
Long-
distance,
high power
E32-T17L
20,000*1 20,000*1
10,000 4,000 13,000 10,000 6,500 4,000
E32-TC200 + E39-F1
4,000*24,000*2
2,600 1,500 4,000 3,700 2,400 1,500
E32-T11R + E39-F1
4,000*2
3,700 2,400 970 3,100 2,400 1,600 970
E32-T11 + E39-F1
4,000*2
3,600 2,300 930 3,000 2,300 1,500 930
E32-T14
4,000*2
3,400 2,250 900 2,900 2,200 1,450 900
E32-T11L/E32-T12L 1,700 1,330 870 350 1,100 870 580 350
E32-T11L + E39-F2 910 800 500 180 600 520 340 180
E32-T11R + E39-F2 520 400 250 100 330 260 170 100
E32-T11 + E39-F2 820 660 430 160 530 430 280 160
E32-T21L/E32-T22L 540 440 250 100 340 260 170 100
Ultracom-
pact,
ultrafine
sleeve
E32-T223R 160 130 75 30 110 85 55 30
E32-T33-S5 53 44 25 10 35 28 18 10
E32-T333-S5 1210648654
E32-T334-S5 65324322
Fine beam E32-T22S 2,500 1,900 1,250 500 1,600 1,250 830 500
E32-T24S 1,750 1,300 870 350 1,100 870 580 350
Area sensing
E32-T16PR 1,100 840 560 220 730 560 370 220
E32-T16P 1,500 1,100 750 300 970 750 500 300
E32-T16JR 980 750 480 190 600 480 320 190
E32-T16J 1,300 1,000 650 260 800 650 430 260
E32-T16WR 1,700 1,300 850 340 1,100 860 570 340
E32-T16W 2,300 1,800 1,150 450 1,400 1,100 730 450
E32-T16 3,700 2,800 1,850 740 2,400 1,800 1,200 740
E32-M21 750 610 350 140 470 360 240 140
E3X-DA-S/MDA
9
* The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm.
Reflective Models (Unit: mm)
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Environ-
ment
resistant
models
Heat-
resistant
E32-T51 1,000 760 500 200 650 500 330 200
E32-T54 300 230 150 60 190 150 100 60
E32-T81R-S 360 280 180 70 230 180 120 70
E32-T61-S + E39-F2 600 450 300 120 390 300 200 120
E32-T61-S + E39-F1 4,000 3,400 2,200 900 3,000 2,200 1,450 900
E32-T84S-S 1,750 1,300 870 350 1,100 870 570 350
E32-T61-S 600 450 300 120 390 300 200 120
Chemical
resistant
E32-T11F 2,500 2,000 1,300 520 1,600 1,300 850 520
E32-T12F 4,000*3,000 2,000 800 2,600 2,000 1,300 800
E32-T14F 500 400 250 100 320 250 160 100
E32-T51F 1,800 1,400 900 350 1,190 920 600 350
E32-T81F-S 920 700 460 190 600 460 300 190
Vacuum
resistant
E32-T51V 260 200 130 50 170 130 85 50
E32-T51V + E39-F1V 1,350 1,000 680 260 850 650 430 260
E32-T54V 210 130 100 35 110 85 55 35
E32-T54V + E39-F1V 660 500 330 180 420 320 210 180
E32-T84SV 630 480 320 130 410 310 200 130
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Standard
models
Flexible
(new stan-
dard)
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R) 300 170 120 50 170 120 80 50
E32-D14LR 80 45 30 14 45 33 22 14
E32-D15YR/E32-D15ZR 70 40 26 12 40 29 19 12
E32-D211R/E32-D21R/E32-D22R/
E32-D25XR/E32-DC200FR(F4R) 50 30 20 8 30 22 14 8
E32-D24R 26 15 10 4 15 10 6 4
E32-D25YR/E32-D25ZR 14852853.32
Standard
E32-DC200/E32-D15X/
E32-DC200B(B4) 500 300 200 90 300 210 130 90
E32-D12 400 230 160 70 230 160 100 70
E32-D14L 200 110 80 36 110 80 50 36
E32-D15Y/E32-D15Z 170 100 65 30 100 70 45 30
E32-D211/E32-DC200E/E32-D22/
E32-D25X/E32-DC200F(F4) 130 80 50 22 80 55 35 22
E32-D24 50 30 20 8 30 22 14 8
E32-D25Y/E32-D25Z 35 20 12 6 20 14 9 6
Break-
resistant
E32-D11/E32-D15XB 300 170 120 50 170 125 80 50
E32-D21B/E32-D221B 110 70 45 20 70 50 30 20
E32-D21/E32-D22B 50 30 20 8 30 22 14 8
E32-D25XB 85 50 30 15 50 35 23 15
Fluorine
coating E32-D11U 300 170 120 50 170 125 80 50
E3X-DA-S/MDA
10
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Special-
beam
models
Long
distance,
high power
E32-D16 40 to
1,000 40
to
700 40 to
450 40
to
240 40
to
600 40
to
490 40 to
300 40
to
240
E32-D11L 650 400 260 110 400 270 180 110
E32-D21L/E32-D22L 210 130 80 35 130 85 55 35
Ultracom-
pact, ultrafine
sleeve
E32-D33 25 16 10 4 16 10 6 4
E32-D331 5320.8321.30.8
Coaxial/small
spot
E32-CC200R 250 150 100 45 150 105 65 45
E32-CC200 500 300 200 90 300 210 140 90
E32-D32L 250 150 100 45 150 100 65 45
E32-C31/E32-D32 120 75 50 22 75 50 30 22
E32-C42 + E39-F3A Spot diameter variable in the range 0.1 to 0.6 mm at distances in the
range 6 to 15 mm.
E32-D32 + E39-F3A Spot diameter variable in the range 0.5 to 1mm at distances in the range
6 to 15 mm.
E32-C41 + E39-F3A-5 0.1-mm dia. spot at a distance of 7 mm.
E32-C31 + E39-F3A-5 0.5-mm dia. spot at a distance of 7 mm.
E32-C41 + E39-F3B 0.2-mm dia. spot at a distance of 17 mm.
E32-C31 + E39-F3B 0.5-mm dia. spot at a distance of 17 mm.
E32-C31 + E39-F3C Spot diameter of 4 mm max. at distances in the range 0 to 20 mm.
Area sensing E32-D36P1 250 150 100 45 150 100 65 45
Retroireflec-
tive
E32-R21 + E39-R3 (provided) 10 to 250
E32-R16 + E39-R1 (provided) 150 to 1,500
Convergent-
reflective
E32-L25/E32-L25A 3.3
E32-L24S 0 to 4
E32-L24L 2 to 6 (center 4)
E32-L25L 5.4 to 9 (center 7.2)
E32-L86 4 to 10
Environ-
ment-
resistant
models
Heat-
resistant
E32-D51 400 230 160 72 230 165 110 72
E32-D81R-S
E32-D61-S 150 90 60 27 90 63 40 27
E32-D73-S 100 60 40 18 60 40 25 18
Chemical-
resistant
E32-D12F 160 95 65 30 95 70 45 30
E32-D14F 70 40 30 10 40 28 18 10
E3X-DA-S/MDA
11
Application-specific Models (Unit: mm)
* The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm.
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Applica-
tion-
specific
models
Label
detection
E32-G14 10
E32-T14 4,000*3,400 2,250 900 2,900 2,200 1,450 900
Liquid-level
detection
E32-L25T Applicable tube: Transparent tube with a diameter in the range 8 to 10
mm and a recommended wall thickness of 1 mm
E32-D36T Applicable tube: Transparent tube (no restriction on diameter)
E32-A01 Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm
and a recommended wall thickness of 1 mm
E32-A02 Applicable tube: Transparent tube with a diameter in the range 6 to 13
mm and a recommended wall thickness of 1 mm
E32-D82F1(F2) Liquid-contact model
Glass-
substrate
alignment
E32-L16-N 0 to 15 0 to 12 0 to 15 0 to 12
E32-A08 10 to 20 --- 10 to 20 ---
E32-A07E1(E2) 15 to 25 --- 15 to 25 ---
E32-L66 5 to 18 5 to 16 --- 5 to 18 5 to 14 ---
Glass-
substrate
Mapping
E32-A09/E32-A09H 15 to 38 --- 15 to 38 ---
E32-A09H2 20 to 30 --- 20 to 30 ---
Wafer
mapping
E32-A03/E32-A03-1 1,150 890 600 250 750 580 380 250
E32-T24S 1,750 1,300 870 350 1,100 870 580 350
E32-A04/E32-A04-1 460 340 225 100 300 220 145 100
E3X-DA-S/MDA
12
Green, Blue, and Infrared Light Sources (Unit: mm)
Model E3X-DAG@-S/DAB@-S E3X-DAH@-S
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Through-
beam
models
Standard
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R) 65 50 35 30 280 190 130 55
E32-T14LR/E32-T15YR/E32-T15ZR 25 20 22 12 100 75 80 21
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4) 100 75 50 45 400 280 180 80
E32-T14L/E32-T15Y/E32-T15Z 50 40 30 25 240 160 110 45
Special beam E32-T11L/E32-T12L 150 120 85 75 700 490 320 140
Reflective
models
Standard
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R) 17 14 10 8 120 90 60 21
E32-D14LR 4.4 3.5 2.5 2.2 32 24 16 5.5
E32-D15YR/E32-D15ZR 4.2 3.3 2.2 2.1 28 20 13 5
E32-DC200/E32-D15X/
E32-DC200B(B4) 32 25 16 16 200 150 100 35
E32-D14L 11 9 6 5.5 80 60 40 14
E32-D15Y/E32-D15Z 10 85.5 565503311
Special beam
E32-D11L 44 35 22 22 260 190 130 45
E32-CC200R 15 12 8 7.5 100 75 50 17
E32-CC200 32 25 16 16 200 150 100 35
E32-D32L 15 12 8 7.5 100 75 50 17
E32-C31/E32-D32 7.5 6 4 3.5 50 37 25 8.5
Applica-
tion-
specific
models
Label
detection
E32-T14 320 260 220 160 1,800 1,200 820 360
E32-G14 10 10
Refer to E32 Series for details on Fiber Units.
E3X-DA-S/MDA
13
Output Circuit Diagrams
NPN Output
Note: 1. The ON/OFF regions when areas settings are used with the E3X-
DA@TW-S are as follows:
LIGHT ON: ON when the incident level is betwee n the thresholds for
channels 1 and 2.
DARK ON: OFF when the incident level is between th e thresholds for
channels 1 and 2.
2. Timing Charts for Timer Function Settings (T: Set Time)
3. Control Output (AND, OR, Sync) and Timing Chart for Timer Set tings
(T: Set Time)
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA11-S
E3X-DA6-S
E3X-DAG11-S
E3X-DAG6-S
E3X-DAB11-S
E3X-DAB6-S
E3X-DA11SE-S
E3X-DA6SE-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA11TW-S
E3X-DA6TW-S
E3X-MDA11
E3X-MDA6
E3X-DA11AT-S
E3X-DA6AT-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA11RM-S
E3X-DA6RM-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA11AN-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
Load
Brown
Black
Blue
Control output
Display
Power
tuning
indicator
(orange)
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
12 to
24 VDC
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
CH1/
CH2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
Output
transistor
Load
(relay)
(Between brown and black leads)
Load
Load
Brown
Black
Orange
Blue
Display Operation indicator
(orange)
ch 1
Operation indicator
(orange) ch 2
Photo-
electric
Sensor
main
circuit
Control
output 1
Control
output 2
12 to
24 VDC
CH1/
CH2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
Output
transistor
Load
(relay)
(Between brown and black leads)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
Brown
Control output
Black
Orange
Blue
Load
Display
Photo-
electric
Sensor
main
circuit
12 to
24 VDC
Operation indicator
(orange)
External
input
Power
tuning
indicator
(orange)
g
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
Analog
output
models
12 to
24 VDC
10kmin
Display
Power
tuning
indicator
(orange)
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
Brown
Black
Orange
Blue
Load
Load
Control output
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
ON delay OFF delay One-shot
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
CH1
CH2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OUT
(sync)
OUT
(OR)
OUT
(AND)
T
CH1
CH2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
One-shot
(AND)
OFF delay
(AND)
ON delay
(AND)
T
T
T
E3X-DA-S/MDA
14
PNP Output
Note: The ON/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
Model Opera-
tion mode Timing chart Operation
selector Output circuit
E3X-DA41-S
E3X-DA8-S
E3X-DAG41-S
E3X-DAG8-S
E3X-DAB41-S
E3X-DAB8-S
E3X-DA41SE-S
E3X-DA8SE-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA41TW-S
E3X-DA8TW-S
E3X-MDA41
E3X-MDA8
E3X-DA41AT-S
E3X-DA8AT-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA41RM-S
E3X-DA8RM-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA41AN-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Load
Brown
Black
Blue
Display
Power
tuning
indicator
(orange)
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
12 to
24 VDC
Control
output
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
CH1/
CH2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Load
Load
Brown
Black
Orange
Blue
Display Operation indicator
(orange)
ch 1
Operation indicator
(orange) ch 2
Photo-
electric
Sensor
main
circuit
Control
output 1
Control
output 2
12 to
24 VDC
CH1/
CH2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Brown
Orange
Black
Blue Load
Display
Photo-
electric
Sensor
main
circuit
12 to
24 VDC
Power
tuning
indicator
(orange)
Operation indicator
(orange)
External
input
Control
output
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
10kmin
Analog
output models
Load Load
Control
output
12 to
24 VDC
Display
Power
tuning
indicator
(orange) Photo-
electric
Sensor
main
circuit
Operation indicator (orange) Brown
Orange
Black
Blue
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
E3X-DA-S/MDA
15
Nomenclature
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
Mounting
Connecting and Disconnecting Connecto rs
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Attach the protector seals (provided as accessories) to the sides of
master and slave connectors that are not connected.
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
WARNING
UP
DOWN
MODE
Lock lever
Locks the fiber.
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
Channel Selector
Use to switch between channels
1 and 2.
Mode Selector
Use to select SET or RUN mode.
Operation indicator for
channel 2 (orange)
ON when output is ON.
OFF when output is OFF.
Operation indicator for
channel 1 (orange)
ON when output is ON.
OFF when output is OFF.
Lock lever
Locks the fiber.
UP
DOWN
MODE
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Power Tuning Indicator
ON: Power tuning is set.
Mode Selector
Use to select SET or RUN mode.
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Precautions for Correct Use
Insert
Seal
Seal
Note: 1. The specifications for ambient t emperature will vary a ccording to the
number of Amplifie r Units used togeth er. For details, r efer to Ratings
and Specifications.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
Remove
Lever
Press down
Click into place
E3X-DA-S/MDA
16
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Fibers with E39-F9 Attachment
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
Adjusting
Mutual Interference Protection Function
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e.,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series
Amplifier Units.
End Plate
20 mm
9 mm
Insertion position
Locked Unlocked
Protective cover
Lock button
Fiber insertion mark
Fiber
Fiber Unit
9 mm
13 mm
Note: 1. To maintain the fiber properties, confirm that the lock is released
before removing the fibers.
2. Be sure to lock or unlock the lock button within an ambient
temperature range bet ween 10°C and 40°C.
9 mm
13 mm
Locked Unlocked
Protective cover
E3X-DA-S/MDA
17
Dimensions
Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Main display Sub-display Vinyl-insulated round cable
Standard length: 2 m*
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
*Cable Specifications
CH1
CH2
Operation indicator
Amplifier Units wit h Cables
E3X-DA11-S
E3X-DA41-S
E3X-DAG11-S
E3X-DAG41-S
E3X-DAB11-S
E3X-DAB41-S
E3X-DA11RM-S
E3X-DA41RM-S
E3X-DA11TW-S
E3X-DA41TW-S
E3X-DA11SE-S
E3X-DA41SE-S
E3X-DA11AT-S
E3X-DA41AT-S
E3X-DA11AN-S
E3X-DA41AN-S
E3X-MDA11
E3X-MDA41
Four, 2.4 dia.
4.5
10
7
5.65
4.5
3.4
4.3 70
32
12.5
9.9
16
34.8
28.1
18.7
44.3 Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2 dia. holes
Hole for optical communications
10
Two, 2.4 dia.
4.5
5.65
3.9 × 3
=11.7
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
3.4 4.4
1628.1
16
A *
Two, M3
* The Mounting Bracket can also
be used on this side.
With Mounting Bracket Attached
Mounting Holes
(E3X-DA@-S) (E3X-MDA@)
(E3X-DA@-S) (E3X-MDA@)
E3X-DA11-S
-DA41-S
-DAG11-S
-DAG41-S
-DAB11-S
-DAB41-S
4-dia., 3-conducto r (C onductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
E3X-DA11TW-S
-DA41TW-S
-DA11RM-S
-DA41RM-S
4-dia., 4-conducto r (C onductor
cross section: 0.2 mm2, insulator
diameter, 1.1 mm)
E3X-MDA11
-MDA41
4-dia., 2-conducto r (C onductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
E3X-DA-S/MDA
18
7
4.5
10
5.65
4.5
Four, 2.4 dia.
3.4
3.9 × 3
=11.75
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
A *1
4.3 70 8.1
32
12.95
9.9
16
34.8
28.1
18.7
44.3 Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2-dia. holes
3.4 4.4
16
Two, M3
10
Two, 2.4 dia.
4.5
5.65
Connector
Dia. A*2
*1 The Mounting Bracket can also be
used on this side.
*2 Cable Diameters
1628.1
Hole for optical communications
CH1
CH2
Main display Sub-display
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Operation indicator
Amplifier Units wit h
C
onnectors
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
E3X-DAG8-S
E3X-DAB6-S
E3X-DAB8-S
E3X-DA6RM-S
E3X-DA8RM-S
E3X-DA6TW-S
E3X-DA8TW-S
E3X-DA6SE-S
E3X-DA8SE-S
E3X-DA6AT-S
E3X-DA8AT-S
E3X-MDA6
E3X-MDA8
(E3X-DA@-S) (E3X-MDA@)
With Mounting Bracket Attached
Mounting Holes
(E3X-DA@-S) (E3X-MDA@)
E3X-CN22
(2 conductors)
E3X-CN21
(4 conductors)
E3X-CN11
(3 conductors)
4.0-mm
dia.
E3X-CN12
(1 conductor) 2.6-mm
dia.
E3X-DA-S/MDA
19
Amplifier Unit Connectors
Master Connectors
E3X-CN11
E3X-CN21
14.4
2.6
6
2.9
10
0.8 8.4
6.8
10.7
50+5
0
30±2
4 dia.
10±2
4
15.1
6
2,000+50
0
*
*E3X-CN11: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave Connectors
E3X-CN12
E3X-CN22
14.4
2.6
3
6
2.9
10
0.8 8.4
6.8
10.7
2,000+50
0
50+5
0
30±2
E3X-CN12: 2.6 dia.
E3X-CN22: 4 dia.
10±2
4
15.1
6
*
*E3X-CN12: 2.6-dia. vinyl-insulated round cable with 1 conductor (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-DA-S/MDA
20
Mobile Console
E3X-MC11-SV2
20
28.8
13.2
31.2
9.9
27.7
17.3
1.2 5.1 12.3
36.7
51.3
5.6
24.3
30.3
M5 ball plunger
31.8 16.3
13.1
(38.2)
10
Communications jack
Optical communica-
tions position
Mobile Console HeadMobile Console
136
50
52.8
22
Optical communications connection indicato
r
Menu indicators
AC adapter jack Communications jack
Channel indicator
Main display
Sub-display
RIGHT key
ESC/PWR key
Operation keys
ENT key
LEFT key
UP key
Sensor
operation
indicator
DOWN
key
Battery
indicators
Channel
buttons
Refer to E32 Series for details on Fiber Units.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.