Safety Matrix 1 Overview ___________________ Installation 2 Maintenance 3 ___________________ 4 ___________________ 8-Channel Analog Input MTA 5 ET 200M Marshalled Termination Assemblies Remote I/O Modules Manual 8-Channel Analog Input MTA ___________________ 8-Channel Analog Output MTA 6 8-Channel TC Input MTA 8 MTA 9 ___________________ 7 8-Channel RTD Input MTA ___________________ 6-Channel F Analog Input 6-Channel F Analog Input ___________________ 10 HART MTA 6-Channel F Analog Input HART MTA 11 ___________________ 16-Channel, 24 VDC Discrete Input MTA 12 ___________________ 12/24-Channel, 24 VDC F 13 Discrete Input MTA 10-Channel, 24 VDC F 14 ___________________ Discrete Output MTA 16-Channel, 24 VDC Discrete Output MTA 16-Channel, 24 VDC Discrete Output MTA 15 ___________________ 16 Failsafe 10-Channel, 24-150 ___________________ VDC/120-230 VAC Relay Output MTA 08/2016 A5E00482820-12 17 16-Channel, 24-150 VDC/120230 VAC Relay Output MTA 18 Power Monitor Board 19 8-Channel HART Analog Input MTA 20 8-Channel HART Analog Output MTA 21 16-Channel, 24 VDC Power Supply MTA 22 Previous MTA Revisions 23 Safety Information for US Customers 24 Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NURNBERG GERMANY A5E00422820-12 08/2016 Subject to change Copyright (c) Siemens AG 2016. All rights reserved Preface Purpose of this Manual This manual contains information on the use of Siemens Marshalled Termination Assemblies (MTAs) to adapt field wiring to ET200M remote I/O modules. Specifically designed for standard and failsafe I/O modules used in ET 200M assemblies, these field termination solutions support analog inputs and outputs, discrete inputs and outputs, and relay outputs. Basic Knowledge Required To understand this manual, you will require a basic knowledge of Siemens SIMATIC PCS 7 systems, S7-400H Systems, and ET200M I/O Modules. Related Manuals Additional information can be found in the following manuals: * Programmable Logic Controllers S7-300 Module Data (ET200M I/O Module Data) * Automation System S7-400H Fault Tolerant Systems * Automation Systems S7-300 Fail-Safe Signal Modules (ET200M Fail-Safe I/O Modules) * Process Control Systems PCS7 Engineering System * Process Control System PCS7 Fault Tolerant Control System * S7-300 CPU 31xC and CPU 31x: Installation, Reference order number A5E00105491-06 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 3 Preface Scope of the Manual This publication does not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to one of the support groups listed in the Product Support section of this manual. The contents of this manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements continued herein do not create new warranties or modify the existing warranty. This manual provides the following basic installation information for adapting field wiring to Siemens MTAs for interface with ET 200M remote I/O modules: 4 * MTA descriptions and diagrams * Installation requirements * Technical specifications * Maintenance information Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Preface Approvals Marshalled Termination Assembly Analog Input 8-Channel 16 bit Part Numbers 6ES7650-1AA50-2XX0 6ES7650-1AA51-2XX0 6ES7650-1AA52-2XX0 Analog Output 8-Channel 12 bit 6ES7650-1AB50-2XX0 RTD Input 8-Channel 6ES7650-1AG50-2XX0 6ES7650-1AB51-2XX0 6ES7650-1AG51-2XX0 TC Input 8-Channel 6ES7650-1AF50-2XX0 Discrete Input 16-Channel 24 VDC 6ES7650-1AC10-3XX0 F Relay Output 10-Channel 24-150 VDC 120-230 VAC 6ES7650-1AF51-2XX0 6ES7650-1AC11-3XX0 2) 6ES7650-1AM30-6XX0 6) 7) 10) 6) 7 )10) 6ES7650-1AM31-6XX0 12) Agency Approvals CE EMC in accordance with EN61000-6-2 EN61000-6-4 ATEX in accordance with EN600079-0 EN600079-15 Safety: 8) EN 61131-2:2007 FM Approved: FM3600, FM3611, FM3810 Class I, Division 2, Groups A,B,C,D; Temperature code T4A at Ta = 60C Class I, Zone 2, Group IIC; Temperature code T4 at Ta = 60C cULus - UL508, CSA C22.2 No.142 cULus haz.loc. - UL1604, CSA C22.2 No.213 11) ISA 12.12.01, CSA C22.2 No.213 Relay Output 16-Channel 24-150 VDC 120-230 VAC 6ES7650-1AM30-3XX0 6) 7) 10) F Analog Input 2) 6-Channel Failsafe 6ES7650-1AH50-5XX0 F Analog Input HART 2) 6-Channel Failsafe 6ES7650-1AH61-5XX0 ATEX in accordance with EN 60079-15 and EN 60079-0 II 3 G Ex nA II T4 Gc T/C & RTD MTA II 3 G Ex nC IIC T4 Gc All others 6ES7650-1AH62-5XX0 11) 12) RCM Mark 6ES7650-1AH51-5XX0 F Discrete Input 2) 12/24-Channel Failsafe 24 VDC 6ES7650-1AK10-7XX0 6ES7650-1AK11-7XX0 12) F Discrete Output 2) 10-Channel Failsafe 24 VDC 6ES7650-1AL11-6XX0 12) Power Monitor Board 3) 6ES7650-1BA02-0XX0 7) 5.6V Diode Board 5) 6ES7650-1AL10-6XX0 5) FET Switch Adapter 4) 5) 6) 6ES7650-1BC51-0XX0 UL60079-15 instead of UL1604 Class I, Division 2, Groups A,B,C,D; Temperature code T4 9) Not for use on MTAs with covers 10) See manual for special temperature restrictions 6ES7650-1BD50-0XX0 12) 6ES7650-1BB50-0XX0 9) 6ES7650-1BB51-0XX0 9) 6.2V Diode Board Temperature Range -25 to 60C 2) TUV (Functional Safety) IEC61508 (SIL3, Relay MTA's SIL 2) 3) Accessory TUV when used with any Failsafe MTA 4) Accessory - used with F Analog Input 5) Accessory - used with F Analog Input MTA 6ES7650-1BC50-0XX0 6ES7650-1BD51-0XX0 Discrete Output 16-Channel 24 VDC 6ES7650-1AD10-2XX0 HART Analog Input 8-Channel 6ES7650-1AA61-2XX0 7) HART Analog Output 8-Channel 6ES7650-1AB61-2XX0 7) 6ES7650-1AD11-2XX0 11) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 7) Temperature Range -25 to 70C TUV (Functional Safety, Safety of machinery) IEC61508:2010 IEC 62061 AMD 2 EN ISO 13849:2015 5 Preface Marshalled Termination Assembly Power Supply 16-Channel 24VDC Part Numbers Agency Approvals 6ES7650-1BE10-3XX0 11) Additional Support If you have questions about the use of products presented in this manual, contact your local Siemens representative: http://www.siemens.com/automation/partner A&D Technical Support Available worldwide, 24 hours a day: United States: Johnson City, TN Worldwide: Nurnberg Asia / Australia: Beijing Technical Support and Authorization Technical Support and Authorization Local time: Monday to Friday 8:00 AM to 5:00 PM Telephone:+1 (423) 262 2522 or +1 (800) 333-7421 (USA only) Fax:+1 (423) 262 2289 Support Request: Technical Support 24 hours a day, 365 days a year Phone:+49 (180) 5050-222 Fax:+49 (180) 5050-223 E-Mail: ad.support@siemens.com GMT:+1:00 Authorization Local time: Monday to Friday http://www.siemens.com/automation/ 8:00 AM to 5:00 PM support-request Phone: +49 (180) 5050-222 Local time: Monday to Friday 8:00 AM to 5:00 PM Phone:+86 10 64 75 75 75 Fax:+86 10 64 74 74 74 Mail to: ad.support.asia@siemens.com GMT:+8:00 Fax: +49 (180) 5050-223 Mail to: ad.support@siemens.com GMT: +1:00 Automation and Drives Service and Support International http://www.siemens.com/automation/service&support The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English. 6 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Preface Service & Support on the Internet In addition to our paper documentation, we also provide all of our technical information on the Internet at: http://www.siemens.com/automation/service&support Here, you will find the following information: * Newsletter providing the latest information on your products * Exactly the right documents for your needs, which you can access by performing an online search in "Service & Support" * Forum in which users and experts worldwide exchange ideas * Your local contact person, who can be accessed in our Contacts database * Information about local service, repair, and replacement parts. Much more information can be found under "Services." Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 7 Preface 8 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Contents 1 2 3 4 5 Overview 17 1.1 System Architecture........................................................................................... 17 1.2 Marshalled Termination Assemblies (MTAs) ..................................................... 18 1.3 General Construction and Dimensions .............................................................. 20 1.4 Interconnecting Cables ...................................................................................... 22 1.5 Interconnecting Cable Assemblies .................................................................... 23 Installation 27 Environmental Considerations .......................................................................................... 29 2.1 Mechanical Installation ...................................................................................... 30 2.2 Electrical Installation .......................................................................................... 30 2.2.1 Cabinet Guidelines ............................................................................................ 30 2.2.2 Wiring Guidelines ............................................................................................... 31 2.3 Installation Procedure ........................................................................................ 32 2.3.1 Without Cover and Frame.................................................................................. 32 2.3.2 With Cover and Frame....................................................................................... 32 2.4 Removal Procedure ........................................................................................... 33 2.4.1 Without Cover .................................................................................................... 33 2.4.2 With Cover ......................................................................................................... 33 Maintenance 35 3.1 Tools and Test Equipment ................................................................................. 36 3.2 Preventative Maintenance ................................................................................. 36 3.2.1 Environmental Consideration ............................................................................ 36 3.2.2 Visual Inspection ................................................................................................ 36 8-Channel Analog Input MTA 37 4.1 Description ......................................................................................................... 37 4.2 Features ............................................................................................................. 37 4.3 Operation ........................................................................................................... 38 4.4 Installation Requirements .................................................................................. 39 4.5 Maintenance ...................................................................................................... 39 4.6 8-Channel Analog Input Marshalled Termination Assembly ............................. 40 4.7 Technical Specifications .................................................................................... 42 4.8 Module Restrictions ........................................................................................... 43 4.9 Typical Transmitter Connection to Field Terminals ........................................... 43 4.10 Hardware Configuration ..................................................................................... 45 4.10.1 Addresses .......................................................................................................... 45 4.10.2 Inputs ................................................................................................................. 46 4.10.3 Redundancy ....................................................................................................... 47 4.11 Technical Specifications for 8-Channel Analog Input Module (6ES7 331-7NF000AB0) ................................................................................................................. 48 8-Channel Analog Input MTA 49 5.1 Description ......................................................................................................... 49 5.2 Features ............................................................................................................. 49 5.3 Modification vs 8-Channel Analog Input MTA 6ES7650-1AA51-2XX0 ............ 49 5.4 Operation ........................................................................................................... 50 5.5 Installation Requirements .................................................................................. 51 5.6 Maintenance ...................................................................................................... 51 5.7 8-Channel Analog Input Marshalled Termination Assembly ............................. 52 5.8 Technical Specifications .................................................................................... 54 5.9 Module Restrictions ........................................................................................... 57 5.10 Typical Transmitter Connection to Field Terminals ........................................... 57 5.11 Hardware Configuration ..................................................................................... 58 5.11.1 Addresses .......................................................................................................... 58 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 9 Contents 5.11.2 5.11.3 5.12 6 7 8 9 10 Inputs ................................................................................................................. 59 Redundancy ....................................................................................................... 60 Technical Specifications for 8-Channel Analog Input Module (6ES7 331-7NF000AB0 / 6ES7331-7NF10-0AB0) ......................................................................... 60 8-Channel Analog Output MTA 61 6.1 Description ......................................................................................................... 61 6.2 Features ............................................................................................................. 61 6.3 Operation ........................................................................................................... 62 6.4 Installation Requirements .................................................................................. 62 6.5 Maintenance ...................................................................................................... 62 6.6 8-Channel Analog Output Marshalled Termination Assembly........................... 63 6.7 Technical Specifications .................................................................................... 64 6.8 Module Restrictions ........................................................................................... 65 6.9 Typical Load Connection to Field Terminals ..................................................... 65 6.10 Hardware Configuration ..................................................................................... 66 6.10.1 Addresses .......................................................................................................... 66 6.10.2 Outputs .............................................................................................................. 67 6.10.3 Redundancy ....................................................................................................... 68 6.11 Technical Specifications for 8-Channel Analog Output Module (6ES7 3325HF00-0AB0) ..................................................................................................... 68 8-Channel RTD Input MTA 69 7.1 Description ......................................................................................................... 69 7.2 Features ............................................................................................................. 69 7.3 Operation ........................................................................................................... 69 7.4 Installation Requirements .................................................................................. 70 7.5 Maintenance ...................................................................................................... 70 7.6 8-Channel, RTD Input Marshalled Termination Assembly ................................ 71 7.7 Technical Specifications .................................................................................... 72 7.8 Module Restrictions ........................................................................................... 73 7.9 Typical R & RTD Connection to Field Terminals ............................................... 74 7.10 Hardware Configuration ..................................................................................... 75 7.10.1 Addresses .......................................................................................................... 75 7.10.2 Inputs - Part 1 ................................................................................................... 76 7.10.3 Inputs - Part 2 ................................................................................................... 77 7.11 Technical Specifications for 8-Channel RTD Input Module (6ES7 331-7PF000AB0 & 6ES7 331-7PF01-0AB0) ...................................................................... 77 8-Channel TC Input MTA 79 8.1 Description ......................................................................................................... 79 8.2 Features ............................................................................................................. 79 8.3 Operation ........................................................................................................... 79 8.4 Installation Requirements .................................................................................. 80 8.5 Maintenance ...................................................................................................... 80 8.6 8-Channel TC Input Marshalled Termination Assembly .................................... 81 8.7 Technical Specifications .................................................................................... 82 8.8 Module Restrictions ........................................................................................... 83 8.9 Typical Thermocouple Connection to Field Terminals ...................................... 83 8.10 Hardware Configuration ..................................................................................... 84 8.10.1 Addresses .......................................................................................................... 84 8.10.2 Inputs - Part 1 ................................................................................................... 85 8.10.3 Inputs - Part 2 ................................................................................................... 86 8.11 Technical Specifications for 8-Channel TC Input Module (6ES7 331-7PF100AB0 & 6ES7 331-7PF11-0AB0) ...................................................................... 86 6-Channel F Analog Input MTA 87 9.1 6-Channel F Analog Input MTA ......................................................................... 87 9.2 Description ......................................................................................................... 87 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Contents 9.3 9.4 9.5 9.6 9.7 9.8 9.9 9.10 9.11 9.11.1 9.11.2 9.11.3 9.11.4 9.12 10 Features ............................................................................................................. 87 Operation ........................................................................................................... 88 Installation Requirements .................................................................................. 90 Maintenance ...................................................................................................... 91 6-Channel F Analog Input Marshalled Termination Assembly .......................... 92 Technical Specifications .................................................................................... 94 Module Restrictions ........................................................................................... 95 Typical Transmitter Connection to Field Terminals ........................................... 96 Hardware Configuration ..................................................................................... 97 Addresses .......................................................................................................... 97 Inputs - Part 1 ................................................................................................... 98 Inputs - Part 2 ................................................................................................... 99 Redundancy ..................................................................................................... 100 Technical Specifications for 6-Channel F Analog Input Module (6ES7 3361HE00-0AB0) ................................................................................................... 100 9.13 Zener Diode Boards ......................................................................................... 101 9.13.1 Description ....................................................................................................... 101 9.13.2 Operation ......................................................................................................... 101 9.13.3 Installation Requirements ................................................................................ 103 9.13.4 Maintenance .................................................................................................... 103 9.14 Diode Board Assembly .................................................................................... 104 9.15 FET Switch Adapter ......................................................................................... 106 9.15.1 Description ....................................................................................................... 106 9.15.2 Operation ......................................................................................................... 106 9.15.3 Installation Requirements ................................................................................ 106 9.15.4 Maintenance .................................................................................................... 107 9.15.5 Technical Specifications .................................................................................. 110 9.16 Input Sharing ................................................................................................... 111 9.16.1 Description ....................................................................................................... 111 9.16.2 Purpose............................................................................................................ 111 9.16.3 Operation ......................................................................................................... 111 9.16.4 FAI MTA to SAI MTA Cable ............................................................................. 112 9.16.5 Hardware Configuration ................................................................................... 114 6-Channel F Analog Input HART MTA 117 10.1 Description ....................................................................................................... 117 10.2 Features ........................................................................................................... 117 10.3 Operation ......................................................................................................... 118 10.4 Installation Requirements ................................................................................ 120 10.5 Maintenance .................................................................................................... 120 10.6 6-Channel F Analog Input HART Marshalled Termination Assembly ............. 121 10.7 Technical Specifications .................................................................................. 123 10.8 Changes to the Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) ....................................................... 124 10.9 Typical Transmitter Connection to Field Terminals ......................................... 125 10.10 Hardware Configuration ................................................................................... 125 10.11 Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) ........................................................................................... 125 10.12 Zener Diode Boards ......................................................................................... 126 10.12.1 Description ....................................................................................................... 126 10.12.2 Operation ......................................................................................................... 126 10.12.3 Installation Requirements ................................................................................ 128 10.12.4 Maintenance .................................................................................................... 128 10.13 Diode Board Assembly .................................................................................... 130 10.14 Input Sharing ................................................................................................... 132 10.14.1 Description ....................................................................................................... 132 10.14.2 Purpose............................................................................................................ 132 10.14.3 Operation ......................................................................................................... 133 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 11 Contents 11 12 13 12 10.14.4 FAIH MTA to SAI MTA Cable .......................................................................... 133 10.14.5 Hardware Configuration ................................................................................... 135 6-Channel F Analog Input HART MTA 137 11.1 Description ....................................................................................................... 137 11.2 Features ........................................................................................................... 137 11.3 Modification vs 6-Channel F Analog Input MTA 6ES7650-1AH61-5XX0 ........ 137 11.4 Operation ......................................................................................................... 138 11.5 Installation Requirements ................................................................................ 141 11.6 Maintenance .................................................................................................... 141 11.6.1 Maintenance for 2-wire transducer supply....................................................... 142 11.6.2 6-Channel F Analog Input HART Marshalled Termination Assembly ............. 144 11.7 Technical Specifications .................................................................................. 146 11.8 Changes to the Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) ....................................................... 147 11.9 Typical Transmitter Connection to Field Terminals ......................................... 148 Hardware Configuration .................................................................................................. 149 11.10 Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) ........................................................................................... 149 11.11 Input Sharing ................................................................................................... 150 11.11.1 Description ....................................................................................................... 150 11.11.2 Purpose............................................................................................................ 150 11.11.3 Operation ......................................................................................................... 151 11.11.4 FAIH MTA to SAI MTA Cable .......................................................................... 151 11.11.5 Hardware Configuration ................................................................................... 153 16-Channel, 24 VDC Discrete Input MTA 156 12.1 Description ....................................................................................................... 156 12.2 Features ........................................................................................................... 156 12.3 Operation ......................................................................................................... 157 12.4 Installation Requirements ................................................................................ 157 12.5 Maintenance .................................................................................................... 157 12.6 16-Channel, 24 VDC Discrete Input Marshalled Termination Assembly......... 158 12.7 Technical Specifications .................................................................................. 159 12.8 Module Restrictions ......................................................................................... 160 12.9 Typical Transmitter Connection to Field Terminals ......................................... 161 12.10 Hardware Configuration ................................................................................... 162 12.10.1 Addresses ........................................................................................................ 162 12.10.2 Inputs ............................................................................................................... 163 12.10.3 Time-of-Day Stamp.......................................................................................... 164 12.10.4 Redundancy ..................................................................................................... 165 12.11 Technical Specifications for 16-Channel, 24 VDC Discrete Input Module (6ES7 321-7BH01-0AB0) ........................................................................................... 165 12/24-Channel, 24 VDC F Discrete Input MTA 167 13.1 Description ....................................................................................................... 167 13.2 Features ........................................................................................................... 167 13.3 Operation ......................................................................................................... 168 13.4 Installation Requirements ................................................................................ 168 13.5 Maintenance .................................................................................................... 168 13.6 Simplified diagram ........................................................................................... 169 13.7 12/24-Channel, 24 VDC F Discrete Input Marshalled Termination Assembly 171 13.8 Technical Specifications .................................................................................. 172 13.9 Technical Specifications .................................................................................. 173 13.10 Module Restrictions ......................................................................................... 174 13.11 Typical Transmitter Connection to Field Terminals ......................................... 176 13.12 Hardware Configuration ................................................................................... 177 13.12.1 Addresses ........................................................................................................ 177 13.12.2 Parameters ...................................................................................................... 178 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Contents 14 15 16 13.12.3 Module Parameters ......................................................................................... 179 13.12.4 Redundancy ..................................................................................................... 181 13.13 Technical Specifications for 12/24-Channel, 24 VDC F Discrete Input Module (6ES7 326-1BK00-0AB0 or 6ES7 326-1BK01-0AB0 or 6ES7 326-1BK02-0AB0)182 10-Channel, 24 VDC F Discrete Output MTA 183 14.1 Description ....................................................................................................... 183 14.2 Features ........................................................................................................... 183 14.3 Operation ......................................................................................................... 184 14.4 Installation Requirements ................................................................................ 184 14.5 Maintenance .................................................................................................... 185 14.6 Simplified diagram ........................................................................................... 186 14.7 10-Channel, 24 VDC F Discrete Output Marshalled Termination Assembly... 187 14.8 Technical Specifications .................................................................................. 188 14.9 Technical Specifications .................................................................................. 189 14.10 Module Restrictions ......................................................................................... 190 14.11 Typical Load Connection to Field Terminals ................................................... 192 14.12 Hardware Configuration ................................................................................... 192 14.12.1 Addresses ........................................................................................................ 192 14.12.2 Outputs ............................................................................................................ 194 14.12.3 Redundancy ..................................................................................................... 195 14.13 Technical Specifications for 10-Channel, 24 VDC F Discrete Output Module (6ES7 326-2BF10-0AB0) ................................................................................. 195 16-Channel, 24 VDC Discrete Output MTA 197 15.1 Description ....................................................................................................... 197 15.2 Features ........................................................................................................... 197 15.3 Operation ......................................................................................................... 198 15.4 Installation Requirements ................................................................................ 198 15.5 198 15.6 Maintenance .................................................................................................... 199 15.7 Component Identification ................................................................................. 199 15.8 Technical Specifications .................................................................................. 200 15.9 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH010AB0) Specifications ........................................................................................ 202 15.10 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) ................................................................................ 203 15.11 Typical Load Connection to Field Terminals ................................................... 203 15.12 Hardware Configuration ................................................................................... 204 15.12.1 Addresses ........................................................................................................ 204 15.12.2 Outputs ............................................................................................................ 205 15.12.3 Redundancy ..................................................................................................... 206 16-Channel, 24 VDC Discrete Output MTA 207 16.1 Description ....................................................................................................... 207 16.2 Features ........................................................................................................... 207 16.3 Operation ......................................................................................................... 207 16.4 Installation Requirements ................................................................................ 208 16.5 Maintenance .................................................................................................... 208 16.6 Simplified diagram ........................................................................................... 210 16.7 Component Identification ................................................................................. 211 16.8 Technical Specifications .................................................................................. 213 16.9 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH100AB0) Specifications ........................................................................................ 215 16.10 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH10-0AB0) ................................................................................ 215 16.11 Typical Load Connection to Field Terminals ................................................... 216 16.12 Hardware Configuration ................................................................................... 217 16.12.1 Addresses ........................................................................................................ 217 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 13 Contents 17 18 19 20 14 16.12.2 Outputs ............................................................................................................ 218 16.12.3 Redundancy ..................................................................................................... 219 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 220 17.1 Description ....................................................................................................... 220 17.2 Features ........................................................................................................... 220 17.3 Operation ......................................................................................................... 221 17.4 Installation Requirements ................................................................................ 221 17.5 Maintenance .................................................................................................... 222 17.6 Simplified diagram ........................................................................................... 223 17.7 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly ..................................................................................... 224 17.8 Technical Specifications .................................................................................. 226 17.8.1 Technical Specifications for 6ES7650-1AM30-6XX0 ...................................... 226 17.8.2 Technical Specification for 6ES7650-1AM31-6XX0 ........................................ 227 17.9 Module Restrictions ......................................................................................... 230 17.9.1 Module Restrictions for 6ES7650-1AM30-6XX0 ............................................. 230 17.9.2 Module Restrictions for 6ES7650-1AM31-6XX0 ............................................. 231 17.10 Typical Load Connection to Field Terminals ................................................... 232 17.11 Hardware Configuration ................................................................................... 233 17.11.1 Addresses ........................................................................................................ 233 17.11.2 Outputs ............................................................................................................ 234 17.11.3 Redundancy..................................................................................................... 235 17.12 Technical Specifications for 10-Channel, 24 VDC F Discrete Output Module (6ES7 326-2BF10-0AB0) ................................................................................. 235 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 237 18.1 Description ....................................................................................................... 237 18.2 Features ........................................................................................................... 237 18.3 Operation ......................................................................................................... 238 18.4 Installation Requirements ................................................................................ 238 18.5 Maintenance .................................................................................................... 239 18.6 Component Identification ................................................................................. 240 18.7 Technical Specifications .................................................................................. 242 18.8 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH010AB0) Specifications ........................................................................................ 244 18.9 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) ................................................................................ 245 18.10 Typical Load Connection to Field Terminals ................................................... 245 18.11 Hardware Configuration ................................................................................... 246 18.11.1 Addresses ........................................................................................................ 246 18.11.2 Outputs ............................................................................................................ 247 18.11.3 Redundancy ..................................................................................................... 248 Power Monitor Board 249 19.1 Description ....................................................................................................... 249 19.2 Features ........................................................................................................... 249 19.3 Operation ......................................................................................................... 249 19.4 Power Monitor Board ....................................................................................... 250 19.5 Technical Specifications .................................................................................. 251 8-Channel HART Analog Input MTA 253 20.1 Description ....................................................................................................... 253 20.2 Features ........................................................................................................... 253 20.3 Operation ......................................................................................................... 254 20.4 Installation Requirements ................................................................................ 255 20.5 Maintenance .................................................................................................... 255 20.6 8-Channel HART Analog Input Marshalled Termination Assembly ................ 256 20.7 Technical Specifications .................................................................................. 257 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Contents 20.8 20.9 20.10 20.11 20.11.1 20.11.2 20.11.3 20.12 21 22 23 24 Changes to Module Specifications .................................................................. 259 259 Typical Wiring Schemes .................................................................................. 260 Hardware Configuration ................................................................................... 262 Addresses ........................................................................................................ 262 Inputs ............................................................................................................... 262 Redundancy ..................................................................................................... 262 Technical Specifications for 8-Channel HART Analog Input Module (6ES7 3317TF01-0AB0) ................................................................................................... 262 8-Channel HART Analog Output MTA 263 21.1 Description ....................................................................................................... 263 21.2 Features ........................................................................................................... 263 21.3 Operation ......................................................................................................... 264 21.4 Installation Requirements ................................................................................ 264 21.5 Maintenance .................................................................................................... 264 21.6 8-Channel HART Analog Output Marshalled Termination Assembly .............. 265 21.7 Technical Specifications .................................................................................. 266 21.8 Module Restrictions ......................................................................................... 267 21.9 Typical Wiring Schemes .................................................................................. 268 21.10 Hardware Configuration ................................................................................... 269 21.10.1 Addresses ........................................................................................................ 269 21.10.2 Outputs ............................................................................................................ 269 21.10.3 Redundancy ..................................................................................................... 269 21.11 Technical Specifications for 8-Channel HART Analog Output Module (6ES7 332-8TF01-0AB0) ............................................................................................ 269 16-Channel, 24 VDC Power Supply MTA 271 22.1 Description ....................................................................................................... 271 22.2 Features ........................................................................................................... 271 22.3 Operation ......................................................................................................... 271 22.4 Installation Requirements ................................................................................ 272 22.5 Maintenance .................................................................................................... 272 22.6 Simplified diagram ........................................................................................... 273 22.7 Component Identification ................................................................................. 274 22.8 Technical Specifications .................................................................................. 275 22.9 Typical Load Connection to Field Terminals ................................................... 277 22.10 Hardware Configuration ................................................................................... 277 Previous MTA Revisions 279 23.1 8 Channel Analog Input MTA .......................................................................... 279 Safety Information for US Customers 281 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 15 Contents 16 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 1 Overview 1.1 System Architecture Figure 1-1shows MTAs within the system architecture Figure 1-1 System Architecture Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 17 Overview 1.2 Marshalled Termination Assemblies (MTAs) The following table identifies the Siemens Marshalled Termination Assemblies (MTAs) discussed in this manual, including associated SIMATIC PCS 7 ET 200M I/O modules and interconnecting cables. Table 1-1 Marshalled Termination Assembly and Module Cross-Reference Marshalled Termination Assembly Part Numbers PCS 7 ET 200M Module 6ES7650-1AA50-2XX0 Analog Input 8-Channel 16 bit 6ES7331-7NF00-0AB0, E_Stand 5 or higher Yes Analog Input 8-Channel 16 bit 6ES7331-7NF00-0AB0, E_Stand 5 or higher Yes 6ES7650-1AA51-2XX0 6ES7650-1AA52-2XX0 Description Redundant Part Number 6ES7331-7NF10-0AB0, E_Stand 8 or higher 6ES7650-1AB50-2XX0 6ES7650-1AB51-2XX0 6ES7650-1AG50-2XX0 6ES7650-1AG51-2XX0 6ES7650-1AF50-2XX0 6ES7650-1AF51-2XX0 Analog Output 8-Channel 12 bit 6ES7332-5HF00-0AB0, E_Stand 3 or higher Yes RTD Input 8-Channel 6ES7331-7PF00-0AB0, E_Stand 8 or higher & No 6ES7331-7PF01-0AB0 TC Input 8-Channel 6ES7331-7PF10-0AB0, E_Stand 4 or higher & No 6ES7331-7PF11-0AB0 F Analog Input 6-Channel Failsafe 6ES7336-1HE00-0AB, E_Stand 4 or higher Yes F Analog Input HART 6-Channel Failsafe HART 6ES7336-4GE00-0AB0 Yes F Relay Output 10-Channel Failsafe 24 VDC 6ES7326-2BF10-0AB0, E_Stand 3 or higher Yes F Discrete Input 12/24-Channel Failsafe 24 VDC 6ES7326-1BK00-0AB0, & 6ES7326-1BK01-0AB0, E_Stand 1 or higher Yes Discrete Input 16-Channel 24 VDC 6ES7321-7BH01-0AB0, E_Stand 2 or higher Yes F Discrete Output 10-Channel Failsafe 24 VDC 6ES7326-2BF10-0AB0, E_Stand 3 or higher Yes 6ES7650-1AD10-2XX0 Discrete Output 16-Channel 24 VDC 6ES7322-8BH01-0AB0 E_Stand 1 or higher Yes 6ES7650-1AD11-2XX0 Discrete Output 16-Channel 6ES7322-8BH10-0AB0 Yes 6ES7322-8BH01-0AB0 E_Stand 1 or higher Yes 6ES7650-1AH50-5XX0 6ES7650-1AH51-5XX0 6ES7650-1AH61-5XX0 6ES7650-1AH62-5XX0 6ES7650-1AM30-6XX0 6ES7650-1AM31-6XX0 6ES7650-1AK10-7XX0 6ES7651-1AK11-7XX0 6ES7650-1AC10-3XX0 6ES7650-1AC11-3XX0 6ES7650-1AL10-6XX0 6ES7650-1AL11-6XX0 24 VDC 6ES7650-1AM30-3XX0 18 Relay Output 16-Channel 24 - 150 VDC 120 - 230 VAC Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Overview Table 1-1 Marshalled Termination Assembly and Module Cross-Reference Marshalled Termination Assembly Part Numbers PCS 7 ET 200M Module 6ES7650-1AA61-2XX0 HART Analog Input 8-Channel HART Analog Output 8-Channel 6ES7650-1AB61-2XX0 Description Redundant Part Number 6ES7331-7TF01-0AB0 Yes 6ES7332-8TF01-0AB0 Yes 6ES7650-1BE10-3XX0 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 19 Overview 1.3 General Construction and Dimensions Figure 1-2 shows the general construction of a Marshalled Termination Assembly (MTA). There are two basic sizes for MTAs a long version and a short version. Refer to the technical specifications for the MTAs for dimensions. Figure 1-3 shows a typical long version. Only the high voltage versions have covers. 20 FRAME MOUNTING SCREWS COVER RETAINING TABS 4 PLACES COVER POWER CONNECTORS BREAK AWAY TABS FOR THE GROUND STUD, THE POWER TERMINALS AND THE OPTIONAL POWER MONITOR BOARD ARE LOCATED ON THIS FACE. OPTIONAL POWER MONITOR BOARD FRAME FRAME TABS NOTE: COVER AND FRAME ARE ONLY APPLICABLE TO HIGH VOLTAGE MTAS FIELD CONNECTORS TERMINATION BOARD ASSEMBLY HOUSING LATCH LATCH SPRING Figure 1-2 General Construction Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Overview Figure 1-3 Dimensions in inches [mm] Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 21 Overview 1.4 Interconnecting Cables Each MTA requires one of five types of interconnecting cable, available in standard lengths of 3 and 8 meters. See the table below. Table 1-2 Interconnecting Cables MTA Interconnecting Cable Description Order Number Analog Input Siemens 40-pin to D25F for connecting 6ES7331-7NF00-0AB0 8-Channel (6ES7650-1AA52-2XX0) 6ES7922-3BD00-0BA0 (3M Length) 6ES7922-3BJ00-0BA0 (8M Length) for connecting 6ES7331-7NF10-0AB0 6ES7922-3BD00-0BB0 (3M Length) 6ES7922-3BJ00-0BB0 (8M Length) Analog Input 8-Channel Analog Output 8-Channel RTD Input 8-Channel TC Input 8-Channel F Discrete Input 12/24-Channel Failsafe 24 VDC Siemens 40-pin to D50F 6ES7922-3BD00-0AS0 (3M Length) 6ES7922-3BJ00-0AS0 (8M Length) Siemens 20-pin to D50F 6ES7922-3BD00-0AU0 (3M Cable) 6ES7922-3BJ00-0AU0 (8M Cable) F Relay Output 10-Channel 24-150 VDC / 120-230 VAC Relay Output 16-Channel 24 - 150 VDC 120 - 230 VAC F Analog Input 1) 6-Channel F Analog Input HART2) 6-Channel Discrete Input 16-Channel 24 VDC Siemens 20-pin to D25F F Discrete Output 10-Channel Failsafe 24 VDC Siemens 40-pin to D25F 6ES7922-3BD00-0AN0 (3M Length) 6ES7922-3BJ00-0AN0 (8M Length) Discrete Output 16-Channel 24 VDC Siemens 40-pin to D25M 6ES7922-3BD00-0AT0 (3M Cable) 6ES7922-3BJ00-0AT0 (8M Cable) HART Analog Input 8-Channel Siemens 20-pin to D25F 6ES7922-3BD01-0AM0 (3M Cable) 6ES7922-3BJ01-0AM0 (8M Cable) 1) For use with 6ES7 336-1HE00-0AB, E-Stand 4 or higher only. 2) For use with 6ES7 336-4GE00-0AB0 only. 22 6ES7922-3BD00-0AM0 (3M Length) 6ES7922-3BJ00-0AM0 (8M Length) Or 6ES7922-3BD01-0AM0 (3M Cable) 6ES7922-3BJ01-0AM0 (8M Cable) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Overview ! 1.5 Caution It is possible to short-circuit the power pins on the MTA with the shield of the D50 or D25 on the interconnecting cable. Use care when disconnecting the MTA end of the interconnecting cable from a powered MTA. When removing the interconnecting cable, use the following techniques in this order whenever possible: * Remove power from the MTA. * Remove the PCS 7 end of the interconnecting cable. * Remove the MTA end of the interconnecting cable. Interconnecting Cable Assemblies Four interconnecting cables support all the termination assemblies and their respective I/O modules. (See Figures 1-2 through 1-5) Note Interconnecting cables are intended for stationary installations only. Siemens 40 pin to Female Sub-D 50 The most common interconnecting cable uses a 40 pin Siemens ET200M I/O connector wired to a D50 female connector. See Figure 1-4 Figure 1-4 Interconnecting Cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ00-0AS0) Key to numbered items in Figure 1-4 Item Part Name 1 50-pin Female Sub-D connector 2 40-pin Siemens connector (6ES7 392-1AM00-0AA0) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 23 Overview Siemens 20 pin to Female Sub-D 25 A second interconnecting cable uses a 20 pin Siemens ET200M I/O connector wired to a D25 female connector. See Figure 1-5 Figure 1-5 Interconnecting Cable (6ES7922-3BD01-0AM0 or 6ES7922-3BJ01-0AM0) and (6ES7922-3BD01-0AM0 or 6ES7922-3BJ01-0AM0) Key to numbered items in Figure 1-5 Item Part Name 1 25-pin Female Sub-D connector 2 20-pin Siemens connector (6ES7 392-1AJ00-0AA0) Siemens 40 pin to Female Sub-D 25 A third interconnecting cable uses a 40 pin Siemens ET200M I/O connector wired to a D25 female connector. See Figure 1-6 Figure 1-6 Interconnecting Cable (6ES7922-3BD00-0AN0 or 6ES7922-3BJ00-0AN0, 6ES7922-3BD00-0BA0 or 6ES7922-3BJ00-0BB0 and 6ES7922-3BD00-0BB0 or 6ES7922-3BJ00-0BB0 ) Key to numbered items in Figure 1-6 Item 24 Part Name 1 25-pin Female Sub-D connector 2 40-pin Siemens connector (6ES7 392-1AM00-0AA0) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Overview Siemens 40 pin to Male Sub-D 25 A fourth interconnecting cable uses a 40 pin Siemens ET200M I/O connector wired to a D25 male connector. See Figure 1-7. Figure 1-7 I Interconnecting Cable (6ES7922-3BD00-0AT0 or 6ES7922-3BJ00-0AT0) Key to numbered items in Figure 1-7 Item Part Name 1 25-pin Male Sub-D connector 2 40-pin Siemens connector (6ES7 392-1AM00-0AA0) Siemens 20 pin to Female Sub-D 50 A fifth interconnecting cable uses a 20 pin Siemens ET200M I/O connector wired to a D50 female connector. See Figure 1-8. Figure 1-8 Interconnecting Cable (6ES7922-3BD00-0AU0 or 6ES7922-3BJ00-0AU0) Key to numbered items in Figure 1-8 Item Part Name 1 50-pin Female Sub-D connector 2 20-pin Siemens connector (6ES7 392-1AJ00-0AA0) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 25 2 Installation This section describes installation of the ET200M Marshalled Termination Assemblies. Topics include: installation considerations and mechanical and electrical installation. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D OR nonhazardous locations only. Combinations of equipment in your system are subject to investigation by the local Authority having jurisdiction at the time of installation. Installations shall comply with the latest edition of the manufacturer's instruction manual. Note * The installation shall comply with the relevant requirements of the National Electrical Code(R) (ANSI/NFPA 70) and all other applicable construction and electrical codes. * For Class I, Div 2 locations, power, input and output (I/O) wiring must be in accordance with Class I, Div. 2 wiring methods per Article 501-10B of the National Electrical Code. * Refer to Use of subassemblies/modules in a Zone 2 Hazardous Area Product Information document (19692172) for information on installations in hazardous locations. * Tampering and replacement with non-factory components may adversely affect the safe use of the system. Refer to the Preface for Agency Approvals as necessary. Use of the equipment in a manner not specified by the manufacturer may impair the protection provided by the equipment. ! Warning Electrical shock hazard * An electrical shock hazard exists for Relay Output MTAs only when connected to loads with voltage > 30V rms and 42.4V peak or 60V dc * Remove power from all wires and terminals before working on equipment. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 27 Installation ! ! 28 Warning Explosion hazard * Do not connect or disconnect equipment unless power has been removed or the area is known to be non-hazardous. * Insertion or withdrawal of removable electrical connectors or modules is to be accomplished only when the area is known to be free of flammable vapors. * Observe all pertinent regulations regarding installation in hazardous area * WARNING - EXPLOSION HAZARD - Do not disconnect while circuit is live unless area is known to be non-hazardous. * WARNING - EXPLOSION HAZARD - Substitution of components may impair suitability for Class I, Division 2 * This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only * WARNING: Explosion Hazard. Do not remove or replace fuses unless power has been disconnected or the area is known to be free of ignitable concentrations of flammable gases or vapors. Caution Electrostatic discharge can damage or cause the failure of semiconductor devices such as integrated circuits and transistors. The symbol at right may appear on a circuit board or other electronic assembly to indicate that special handling precautions are needed. * A properly grounded conductive wrist strap must be worn whenever an electronics module or circuit board is handled or touched. A service kit with a wrist strap and static dissipative mat is available from Siemens (PN15545-110). Equivalent kits are available from both mail order and local electronic supply companies. * Electronic assemblies must be stored in anti-static protective bags when not installed in equipment. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Installation Environmental Considerations Operate the ET200M MTAs within their environmental specifications to help ensure reliable, trouble-free operation with minimum down time. Refer to the Technical Specifications sections for each MTA's operating temperatures limits, operating humidity, and maximum moisture content. Temperature Keep the air surrounding an operating system below 60C (140F). Check air temperature periodically to ensure that this specification is not being exceeded. ! Caution Exceeding the specified operating temperature limits can adversely affect performance and may cause damage to the MTA. Forced air ventilation is possible when MTAs are mounted in a partially or completely enclosed panel or cabinet (for example, NEMA 1). When clean air is present, exhaust fans are often mounted across the top of a panel and louvers formed in the panel bottom. Air is then drawn upward between the station cases. When air contains particulate matter, fans and filters are generally located at the panel bottom and louvers at the top. Filtered air is now forced upward between the station cases. Filters must be serviced periodically. Only high quality, quiet running fans should be used. Also, the fans should not generate electrical noise which could interfere with electronic instruments. A sealed cabinet (e.g. NEMA 12 or 4X) containing equipment that does not generate significant heat should contain a recirculating fan for forcing air flow around equipment and throughout the cabinet preventing hot spots from developing. Forced air conditioning may be required in very high density panels or consoles. Periodically change or clean air filters. Contaminants The MTA is open to permit circulation of clean cooling air. Liquids and corrosive gases must not be allowed to enter the case. Whether the MTA is in a control room or field mounted it must be protected from rain, air conditioning condensate, and plant and process related fluids and gases. Extended exposure to contaminants can result in malfunctions. Industrial environments often contain airborne particulate contaminants. Particulate matter, usually dust and dirt, is abrasive and can cause intermittent connections. A layer of dust on circuit boards can interfere with component heat dissipation and can absorb other airborne contaminants. Extended exposure to these contaminants may result in malfunctions. Although ET200M MTAs have a protective coating, the following steps can reduce contaminant related equipment malfunctions: 1. Identify contaminants and implement methods to reduce their presence. 2. Install protective housing for field mounted units. 3. When cleaning equipment and surrounding area, especially the floor, either vacuum away all dust and dirt or use a dampened rag or mop. Sweeping or dry dusting recirculates dust and dirt. 4. Clean or replace all air conditioning filters, room air filters, and equipment filters regularly. 5. Inform all personnel with access to the equipment of the need for cleanliness. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 29 Installation 2.1 Mechanical Installation The MTA housing is designed to be used with 35mm x 15mm Top Hat style DIN rail. 2.2 Electrical Installation These sections contain electrical connection details for wiring an ET200M MTA. The Cabinet Guidelines provide required restrictions for installation inside a cabinet and the Wiring Guidelines contains specific information about connector identification, wire size, wire selection, and wire routing. 2.2.1 Cabinet Guidelines Installing the MTAs into a cabinet will protect them from stray signals and the environment. There are, however, certain safety agency restrictions that need to be observed. 30 * The MTA shall be installed in compliance with the enclosure, mounting, and spacing, and segregation requirement of the ultimate application. * MTA's must be installed in an enclosure or cabinet that provides a degree of protection IP54 or better * Cabinet or enclosure shall provide sufficient protection from Impact (IEC6007915, clause 26.3.3.1) * Enclosure or cabinet must be of metal or meet the requirements of IEC6007915 for plastic enclosures * Enclosure or cabinet shall protect MTAs from corrosion * Enclosure or cabinet shall provide suitable earthing facility in accordance with IEC60079-15 clause 6 * Enclosure or cabinet shall provide suitable cable or conduit entries in accordance with IEC60079-15 clause 6 * Provision must be made to prevent transient disturbances that would exceed 33 V * Enclosure shall be marked "Do not remove fuses when energized" and "Do not separate connections when energized" in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Installation 2.2.2 Wiring Guidelines Electrical Connections - Power, I/O, and network connections to a system are completed through removable connectors. For the analog I/O, Discrete Output 16 Channel and Relay Output 16 Channel MTAs the interconnection cable shield must be connected to ground at the I/O module. In environment with great EMC-load the connection made by the connectors may not be sufficient. In this case, after removing the insulation the shield of the cable should be clamped direct to ground. Analog I/O MTAs include analog input, analog output, RTD input, TC input and failsafe analog input MTAs. To ground the shield, the outer insulation must be removed to expose a section of the shield. A shield contact element is installed below the I/O module and the exposed shield placed inside the shield contact element. See S7-300 CPU 31xC and CPU 31x: Installation. Reference order number A5E00105491-06. Connectors - Power terminals are identified by a letter: L+ and M. The ground connection is made to a Shield stud near the power connector. Signal I/O terminals are identified by function (CH+, PWR), channel number (CH0-CH7) and polarity (+/-). 2 Power and signal connectors will accept a maximum of #12 AWG / 3.3mm wire; 2 however, #14 AWG / 2.08mm is specified throughout this manual for ease of use. Power Monitor wiring is smaller and will accept a maximum of #16 AWG wire. Wire Selection - Stranded wire is recommended for most connections, however, solid wire is typically used for thermocouple extension wire. Carefully select wire size, conductor material, and insulation. Some selection considerations are: * Current and voltage to be carried * Total length of each wire run * Whether wire will be bundled or run singly * Indoor or outdoor installation * Temperature extremes (Use supply wires suitable for 5C (10F) above ambient temperature.) * Exposure to sunlight * Vibration * Types of contaminates Note It is recommended that crimp on ferrules with insulating collars be used to terminate stranded field wiring. Wire Routing and Conduit - DC wiring should be separated from AC wiring and away from AC powered pushbuttons, alarms, annunciators, motors, solenoids, and similar devices. Conduit and raceways are commonly used for routing panel wiring. Wiring not installed in conduit or raceway should be clamped or supported approximately every 12 inches (300 mm). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 31 Installation 2.3 Installation Procedure 2.3.1 Without Cover and Frame Step 2.3.2 Action 1 Mount the MTA to the DIN rail (Recommend 35mm x 15mm Top Hat style) 2 For EMC Compliance connect the MTA Shield stud to earth ground. 3 Plug the interconnecting cable into the PCS7 I/O Modules 4 For analog I/O Modules: Install shield connecting element, strip a section of outer insulation from interconnecting cable and place in shield connecting element 5 Plug the interconnecting cable into the D25 or D50 on the MTA 6 Plug the Field terminal connectors into the MTA 7 Plug the IO power connector into the MTA 8 Apply power With Cover and Frame Refer to Figures 1-2 and 2-1 Step 32 Action 1 Mount the MTA to the DIN rail (Recommend 35mm x 15mm Top Hat style) 2 Remove cover using screw driver to disengage the cover retaining tabs from cover. 3 For EMC Compliance remove the Shield Stud Break-Away Tabs (Fig 1-2) on the frame adjacent to the shield stud to connect the MTA Shield stud to earth ground. 4 Plug the interconnecting cable into the PCS7 I/O Modules. 5 For analog I/O Modules: Install shield connecting element, strip a section of outer insulation from interconnecting cable and place in shield connecting element. 6 Plug the interconnecting cable into the D25 or D50 on the MTA. Remove the Module 2 Break-Away Connector Cover (Fig 2-1) to access the connector for module 2 for redundant configurations. 7 Plug the Field terminal connectors into the MTA. 8 Remove the Power Connection Break Away Tabs (Fig 2-1) on the frame adjacent to the power connection and plug the IO power connector into the MTA. 9 If the Power Monitor Board is used, remove the Power Monitor Break-Away Tabs (Fig 2-1) on the frame adjacent to the Power Monitor Board connector and connect to the Power Monitor Board. 10 Snap cover into place 11 Apply power Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Installation 2.4 Removal Procedure Should it be necessary to remove or replace a termination assembly, follow the procedures outlined below. 2.4.1 Without Cover Step 2.4.2 Action 1 Remove power and signals from the MTA 2 Remove ground connection to MTA shield stud if applied 3 Unplug the interconnecting cable into the D25 or D50 on the MTA 4 Unplug the field terminal connectors into the MTA 5 Unplug the IO power connector into the MTA 6 If the Power Monitor Board is used, remove the connection to the Power Monitor Board or remove the Power Monitor Board for use on a replacement MTA. 7 Remove MTA from DIN rail using screwdriver to release the latch. 8 Follow the installation procedure in section 2.3 to install a replacement MTA. With Cover Refer to Figure 1.2 Step Action 1 Remove power and signals from the MTA 2 Remove cover using screw driver to disengage the cover retaining tabs from cover. 3 Remove ground connection to MTA shield stud if applied 4 Unplug the interconnecting cable into the D25 or D50 on the MTA 5 Unplug the field terminal connectors into the MTA 6 Unplug the IO power connector into the MTA 7 Remove MTA from DIN rail using screwdrivers to release the latches. Latches are accessed through slots in frame. 8 Follow the installation procedure in section 2.3 to install a replacement MTA. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 33 Installation 34 SHIELD STUD BREAK AWAY TABS POWER CONNECTION BREAK AWAY TABS POWER MONITOR BREAK AWAY TABS MODULE 2 BREAK AWAY CONNECTOR COVER Figure 2-1 Break-Away Connector Cover and Tabs Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 3 Maintenance MTA maintenance requirements are minimal. Activities such as cleaning and visual inspections should be performed at regular intervals. The severity of the system's operating environment will determine the frequency of maintenance. Additional topics including troubleshooting, assembly replacement, and software compatibility are also covered. Before servicing or calibration the equipment, note the following: ! * Maintenance should be performed only by qualified personnel. Failure to properly maintain the equipment can result in death, serious injury, or product failure. This manual should be carefully reviewed, understood, and followed. * The steps in the Preventive Maintenance section should be performed regularly. * The procedures in this section do not represent an exhaustive survey of maintenance steps necessary to ensure safe operation of the equipment. Particular applications may require further procedures. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the local Siemens sales office. * The use of unauthorized parts in the repair of the equipment or tampering by unqualified personnel will result in dangerous conditions that can cause death, serious injury, or equipment damage. Follow all safety instructions contained herein. Warning Explosion hazard Can cause death or injury Substitution of components may impair suitability for Class I, Division 2. See Section 2, Installation, before performing any maintenance and observe all warnings Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 35 Maintenance 3.1 Tools and Test Equipment The following tools and equipment are necessary for servicing: * Common hand tools for servicing electronic equipment * Digital Multimeter (DMM) - - * 3.2 Voltmeter Section: o Accuracy +/-0.01% of reading o Resolution 1.0 mV input o Impedance 10 M Ammeter section: o Accuracy +/- 0.1% of reading o Resolution 100 A Maintenance Kit, containing wrist strap and conductive mat. Preventative Maintenance The objective for establishing a preventive maintenance program is to provide maximum operating efficiency. Every preventive maintenance operation should assist in realizing this objective. Unless a preventive measure reduces a station's down time, it is unnecessary. 3.2.1 Environmental Consideration The system has been designed to operate within specified environmental parameters (temperature and humidity). 3.2.2 Visual Inspection As part of a periodic maintenance program, the system should be visually inspected. When viewing the MTA, scan for abnormalities such as loose, broken or stressed cables. Look for damaged circuitry and heat stressed parts. Check for excessive dirt or dust build-up which may impede air flow and inhibit proper heat dissipation. 36 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 4 8-Channel Analog Input MTA Part No. 4.1 6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0 Description This section contains installation information and requirements for Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AA51-2XX0 or 6ES76501AA50-2XX0), which connects to the Siemens ET 200M 8-Channel Analog Input Module (6ES7 331-7NF00-0AB0, E-Stand 5 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 4.2 Features This MTA has the following features: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * LED indication of power supply to the field device on an individual channel basis * Per channel fusing of field power * Dual connectors for redundant I/O Module operation * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 37 8-Channel Analog Input MTA 4.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has circuitry to detect the presence of voltage over 15 VDC and turn on the LED indicator. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA power from either input source. The output from CR106 is sent to the channel fuses. This module does not require any power from the I/O power supply and therefore no module power circuitry is required. Each channel has an LED to indicate the presence of power and the fuse status. If there is no power or the fuse is open, then the LED remains dark. If there is power and the fuse is good then the LED is illuminated. The MTA has two types of jumpers for customer use: * I - V jumpers are a header and shunt type that determines the connection to the input signal. * Isolation jumpers are wires that can be cut to isolate the input channel from power return. See Section 4.10, Hardware Configuration. Field Terminals, Channel + (Ix+), Channel - (Ix-), Sensor power (PWRx) and Shield (SHx), connect to the field devices. PWRx is the +24 VDC power feed and is fused (.5A) on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The channel inputs from the MTA connect to the I/O modules inputs via J1 and J2. Redundant operation uses two modules with one each connected to J1 and J2, while non-redundant systems have one module connected to either J1 or J2. 38 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 4.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ000AS0), supporting eight analog input channels, connects the analog input termination assembly to the 8-channel analog input module (6ES7 331-7NF000AB0, E-Stand 5 or higher). See Figure 4-1. It may be necessary to modify the printed circuit board as follows: * For channels measuring voltage, move the I - V jumper for that channel to the V side. * For channels measuring current, move the I - V jumper for that channel to the I side * To separate channel input low from power supply common, cut and remove the jumper associated with that channel, W8 for CH0 through W15 for CH7. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumpers, W100 and W101, for the associated cable. 4.5 Maintenance Under normal operation, the A/B Power LED and all the Channel Fuse LEDs are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Channel Fuse LED is off, check the channel fuse and replace if necessary. See Section 3, Maintenance, before performing any maintenance and observe all warnings. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 39 INPUT C CR106 I V CH0 HART- W0 W8 1.5A MAX F0 CH0 FUSE CH0 HART+ PWR0 I0+ R1 Analog Input 6ES7650-1AA51-2XX0 R100 R101 ZR100 CR104 J3 I V CH1 HART- W1 W9 1.5A MAX F1 CH1 FUSE CH1 HART+ I0- SH0PWR1 I1+ R2 A POWER R9 HART CURRENT INPUT VOLTAGE 2 WIRE 4 WIRE INPUT INT PWR EXT PWR NC PWRx NC POSITIVE POWER + POSITIVE NEGATIVE POSITIVE POSITIVE Ix+ NEGATIVE & NEGATIVE IxNC NEGATIVE POWER W0-W7 V I I I NONNONNONW8-W15 ISOLATED ISOLATED ISOLATED ISOLATED ISOLATED x = CHANNEL # ISOLATED = CUT W8-W15 M A SHIELD R3 1.5A MAX F2 CH2 FUSE CH2 HART+ I W2 V CH2 HART- W10 J2 J1 I1- SH1PWR2 I2+ R1 0 ZR101 R4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 2 1.5A MAX F3 CH3 FUSE CH3 HART+ I W3 V CH3 HART- W11 CH4 HART- I W4 I3- SH3 PWR4 I4+ 1.5A MAX F4 CH4 FUSE CH4 HART+ W12 I4- SH4PWR5 I5+ 1.5A MAX F5 CH5 FUSE I W5 V CH5 HART- W13 CH5 HART+ 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 I2- SH2PWR3 I3+ R1 1 CR105 R1 2 L+ A 40 M B 13 L+ B 1 R5 2 R1 3 11 R6 9 1.5A MAX F6 CH6 FUSE I W6 V CH6 HART- W14 CH6 HART+ W101 W100 I5- SH5PWR6 I6+ R1 4 6 1.5A MAX F7 CH7 FUSE I W7 V CH7 HART- W15 CH7 HART+ I6- SH6PWR7 I7+ R1 5 7 1C1 0 4 R8 8 0C1 0 10 R7 5 I7- SH7 R1 6 4.6 B POWER 8-Channel Analog Input MTA 8-Channel Analog Input Marshalled Termination Assembly The figure below shows the basic parts of the 8-Channel Analog Input MTA. Figure 4-1 8-Channel Analog Input Marshalled Termination Assembly (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0) 32 CH7 SHIELD 31 CH7 I30 CH7 I+ 29 CH7 POWER 28 CH6 SHIELD 27 CH6 I26 CH6 I+ 25 CH6 POWER 24 CH5 SHIELD 23 CH5 I22 CH5 I+ 21 CH5 POWER 20 CH4 SHIELD 19 CH4 I18 CH4 I+ 17 CH4 POWER 16 CH3 SHIELD 15 CH3 I14 CH3 I+ 13 CH3 POWER 12 CH2 SHIELD 11 CH2 I10 CH2 I+ 9 CH2 POWER 8 CH1 SHIELD 7 CH1 I6 CH1 I+ 5 CH1 POWER 4 CH0 SHIELD 3 CH0 I2 CH0 I+ 1 CH0 POWER 3 12 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA Key to numbered items in Figure 4-1: Item Description 1 Input power connections 2 Input Power Indicators 3 Field Connections 4 I/O Module Connections ( J1 & J2 ) 5 Shield disconnect jumper (W100 & W101) 6 Field power fuses 7 Field power indication ( 1 of 8 ) 8 Input Isolation Jumpers ( W8 - W15) 9 HART connectivity 10 Input Mode Jumper ( I - V ) 11 250 resistors ( R9-R16 ) 12 Input Connection Chart 13 Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 41 8-Channel Analog Input MTA 4.7 Technical Specifications Technical Specifications for 8-Channel Analog Input MTA (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) Inrush 8.238 A maximum (Includes 8.16 A for transmitter inrush) Normal 0.265 A maximum Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel - Normal 0.5 A Fast blow (Littelfuse P/N: 273.500) (Siemens Spare P/N: A5E01568880) Individual channel - Optional 1.5 A Fast blow (Littelfuse P/N: 273 01.5) (Siemens Spare P/N: A5E01568886) Max total channel current: 8.16 Amps Module NA Indicators Input Power Green LED on when input power available Module Power NA Channel Power Green LED on when sensor power available Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com 42 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 4.8 Module Restrictions Restrictions for 8-Channel Analog Input MTA (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0) I/O Module Restrictions MTA None SAI Module None Voltage +/-5 V, 1 - 5 V, & +/-10 V Current 0 - 20 mA, +/- 20 mA, & 4 - 20 mA Module Accuracy Voltage Input (MTA I/V set to V) See Module Specs Current Input (MTA I/V set to I) See Module Specs 4.9 Typical Transmitter Connection to Field Terminals Figure 4-2 Analog Input Current Input Connection Examples (MTA I/V Jumper set to I) TB1 +Sig 2 WIRE TRANSMITTER -Sig TB1 +V 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 TB1 +V +Sig ISOLATED 4 WIRE TRANSMITTER -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 -V 1 PWR0 2 I0+ 3 I0- +Sig 4 SH0 NON-ISOLATED 4 WIRE TRANSMITTER -Sig 5 PWR1 6 I1+ 7 I1- 8 SH1 -V Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 43 8-Channel Analog Input MTA Figure 4-3 Analog Input Voltage Input Connection Example (MTA I/V Jumper set to V) TB1 +Sig Voltage Source 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 -Sig 44 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 4.10 Hardware Configuration Use the I - V jumpers to select voltage or current input signals. Configure the AI8 module to match the input signal type. See Figure 4-1, Item 8, for the location of the isolation jumper and Item 10, for the location of the I - V Jumper. 4.10.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 4-4 shows addresses and process image for a redundant configuration. Figure 4-4 8-Channel Analog Input Hardware Configuration: Address Setup for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 45 8-Channel Analog Input MTA 4.10.2 Inputs Select appropriate module hardware configuration settings. Select Measuring Type and Measuring Range settings to match the input signal connected to the channel inputs. Measurement of signals less than 0 volts or 0 mA requires that the channel isolation jumper be cut. Figure 4-5 shows the all the diagnostic boxes checked. Figure 4-5 8-Channel Analog Input Hardware Configuration: Inputs Setup Note 46 * Use the AI8 MTA I - V jumpers to select voltage or current input signals. * Configure the AI8 module to match the input signal type. * See Figure 4-1, Item 10, for the location of the I - V Jumper. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 4.10.3 Redundancy Figure 4-6 shows the redundant configuration. For non-redundant operation, in the Redundancy box, select None. All other parameters should be set to user preferences. Figure 4-6 8-Channel Analog Input Hardware Configuration: Redundancy Selection Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 47 8-Channel Analog Input MTA 4.11 Technical Specifications for 8-Channel Analog Input Module (6ES7 331-7NF00-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). 48 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 5 8-Channel Analog Input MTA Part No. 5.1 6ES7650-1AA52-2XX0 Description This section contains installation information and requirements for Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AA52-2XX0) which connects to the Siemens ET 200M 8-Channel Analog Input Module (6ES7 331-7NF00-0AB0, E-Stand 5 or higher) or the Siemens ET 200M 8-Channel Analog Input Module (6ES7 331-7NF10-0AB0; E-Stand 8 or higher). 5.2 Features This MTA has the following features: 5.3 * Redundant power connections * LED indication of redundant power supply condition * LED indication of reverse polarity * LED indication of module power supply fuse status * Power monitor output * short circuit proofed 2-wire transducer supply per channel * Dual connectors for redundant I/O Module operation * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Connectivity for HART Handheld Terminal (HHT) per channel * Parameterization of current/ voltage and 2-wire/4-wire by jumper Modification vs 8-Channel Analog Input MTA 6ES7650-1AA51-2XX0 * connects AI8x16bit 6ES7 331-7NF00-0AB0 and 6ES7 331-7NF10-0AB0 * electronically short circuit proofed 2-wire transducer supply * no power supply support for 4-wire transducer * Power Monitor System onboard * one piece connectors * short version housing Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 49 8-Channel Analog Input MTA 5.4 Operation Power is supplied via two power connectors marked L/A+, M/A, and L/B+, M/B. Each has a circuitry to detect the presence of voltage over 15 VDC and turn on the LED indicator (green). The case of polarity reversal of the power supply is indicated by the LEDs illuminating red. The LEDs are marked A POWER and B POWER. Incoming power from A and B is diode OR'd to provide the MTA power from either input source. The 6ES7331-7NF00-0AB0 module does not require any power compared to the 6ES7331-7NF10-0AB0 module. For this purpose the output from the diodes is sent to the I/O-Module power supply. An onboard Power Monitor System (PMS) is used to provide an isolated dry contact when redundant power is supplied to MTAs. Only when power is supplied to both power inputs the output contacts 1 and 2 are closed. The Power Monitor System is designed to detect only the presence or absence of power. It is not designed to detect supply voltage which is outside the specification threshold. The MTA has three types of jumpers for customer use: * I - V jumpers are a header and shunt type that determines the connection to the input signal. * 2 - 4 jumpers are a header and shunt type that determines the connection to the input signal. * Isolation jumpers MODULE 1, MODULE 2 are wires that can be used to cut the shield connection between the MTA and the I/O Modules. Field Terminals, Channel + (Ix+), Channel - (Ix-), Sensor power (PWx) and Shield (SHx), connect to the field devices. PWx is the +24 VDC power feed and the current is limited (max. 40mA) electronically on a channel by channel basis. The channel inputs from the MTA connect to the I/O modules inputs via the connectors Module1 and Module2. Redundant operation uses two modules with one each connected to Module1 and Module2, while non-redundant systems have one module connected to either Module1 or Module2. 50 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 5.5 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings Two interconnecting cable types (for Module 6ES7331-7NF00-0AB0: 6ES79223BD00-0BA0 (3m), 6ES7922-3BJ00-0BA0 (8m); for Module 6ES7331-7NF100AB0: 6ES7922-3BD00-0BB0 (3m), 6ES7922-3BJ00-0BB0 (8m)) , supporting eight analog input channels, connects the analog input termination assembly to the 8channel analog input module (6ES7 331-7NF00-0AB0, E-Stand 5 or higher) or to the 8-channel analog input module (6ES7331-7NF10-0AB0). See Figure 5-1. It may be necessary to modify the printed circuit board as follows: * For channels measuring voltage, move the I - V jumper for that channel to the V side and the 2 - 4 jumper for that channel to 4 side. * For channels measuring current, move the I - V jumper for that channel to the I side and the 2 - 4 jumper to 2 for using 2 wire transducer or 4 for using 4 wire transducer. * For channels which are connected to a non isolated 4-wire transducer, set the I - V jumper to I and the 2 - 4 jumper to 2. (see Figure 5-3) Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumpers, Module1 and Module2, for the associated cable. 5.6 Maintenance Under normal operation, the A/B Power LED and the fuse status LEDs, are on. If all are off, check the power supply to the MTA. If the module fuses status LEDs are off, check the fuses Module1 and Module2 of the MTA and replace them if necessary. See Section 3, Maintenance, before performing any maintenance and observe all warnings. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 51 8-Channel Analog Input MTA 5.7 8-Channel Analog Input Marshalled Termination Assembly The figure below shows the basic parts of the 8-Channel Analog Input MTA. Figure 5-1 8-Channel Analog Input Marshalled Termination Assembly (6ES7650-1AA52-2XX0) 12 7 3 9 4 2 10 6 1 6 CH7 CH6 CH7 CH6 CH7 CH6 CH7 CH6 SHIELD SHIELD III+ I+ POWER POWER CH5 CH4 CH5 CH4 CH5 CH4 CH5 CH4 SHIELD SHIELD III+ I+ POWER POWER CH3 CH2 CH3 CH2 CH3 CH2 CH3 CH2 SHIELD SHIELD III+ I+ POWER POWER CH1 CH0 CH1 CH0 CH1 CH0 CH1 CH0 SHIELD SHIELD III+ I+ POWER POWER 5 8 52 11 13 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA Key to numbered items in Figure 5-1: Item Description 1 Input power connections (L/A+, M/A, L/B+, M/B) 2 Output Power Monitoring System (1, 2) 3 I/O Module Connections (MODULE1, MODULE2) 4 Module fuses (MODULE1, MODULE2) 5 Shield Ground Stud for connecting to earth ground (SHIELD) 6 Input Power Indicators (A POWER, B POWER) 7 Shield disconnect jumper (MODULE 1, MODULE 2) 8 250 resistors 9 Module fuse indicators 10 HART connectivity (+, -) 11 Input mode jumper (I - V) 12 Transducer mode jumper (2 - 4) 13 Field connections Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 53 8-Channel Analog Input MTA 5.8 Technical Specifications Technical Specifications for 8-Channel Analog Input MTA 6ES7650-1AA52-2XX0 in use with I/O modules 6ES7331-7NF00-0AB0 and cables 6ES7 392-3Bx00-0BA0 Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep or shallow; with panel mounted DIN rail only deep) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings, all channels 20mA) < 0.2 A Power Dissipation (typical) 1W Permissible potential difference Between the channels AC 35V / DC 50V Fuse Ratings / Current Limiting Module 0.5 A (Bussmann P/N: GMA-0.5-R) (Siemens Spare P/N: A5E00755625) Power output for 2-wire transducer supply Supply current for each channel typ. 20 mA Short circuit current 25 ... 42 mA Load capability > 750 Open loop voltage L+ Short circuit protection electronically; individual for each channel Power Monitoring System - Optorelay Output Contact Ratings Threshold voltage ca. 15 V Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit proofed Indicators Input Power Green LED on when input power available, red LED on if power supply is reversed Module Fuse OK Green LED on when module power available Field Terminals Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental 54 Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA Technical Specifications for 8-Channel Analog Input MTA 6ES7650-1AA52-2XX0 in use with I/O modules 6ES7331-7NF00-0AB0 and cables 6ES7 392-3Bx00-0BA0 Module Accuracy o * Basic error limit (25 C) voltage mode current mode 0,05% 0,15% Operational error limit (overall temperature range; U_cm = 0V) voltage mode current mode 0,1% 0,4% Operational error limit (overall temperature range; U_cm = 50V) voltage mode current mode 0,7% 1,0% * * Approvals MTA Agency Approvals See Preface section, Approvals Table (in User's Manual) Technical Specifications for 8-Channel Analog Input MTA 6ES7650-1AA52-2XX0 in use with I/O modules 6ES7331-7NF10-0AB0 and cables 6ES7 392-3Bx00-0BB0 Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep or shallow; with panel mounted DIN rail only deep) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels 20mA) < 0,5 A Power Dissipation (typical) 1W Permissible potential difference Between the channels AC 60V / DC 75V Fuse Ratings / Current Limiting Module 0.5 A (Bussmann P/N: GMA-0.5-R) (Siemens Spare P/N: A5E00755625) Power output for 2-wire transducer supply Supply current for each channel typ. 20 mA Short circuit current 25 ... 42 mA Load capability > 750 Open loop voltage L+ Short circuit protection electronically; individual for each channel Power Monitoring System - Optorelay Output Contact Ratings Threshold voltage ca. 15 V Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit proofed Indicators Input Power Green LED on when input power available, red LED on if power supply is reversed Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 55 8-Channel Analog Input MTA Technical Specifications for 8-Channel Analog Input MTA 6ES7650-1AA52-2XX0 in use with I/O modules 6ES7331-7NF10-0AB0 and cables 6ES7 392-3Bx00-0BB0 Module Fuse OK Green LED on when module power available Field Terminals Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Technical Specifications for 8-Channel Analog Input MTA 6ES7650-1AA52-2XX0 in use with I/O modules 6ES7331-7NF10-0AB0 and cables 6ES7 392-3Bx00-0BB0 Module Accuracy o * Basic error limit (25 C) voltage mode current mode 0,05% 0,15% Operational error limit (overall temperature range) voltage mode current mode 0,1% 0,2% * Approvals MTA Agency Approvals See Preface section, Approvals Table (in User's Manual) Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com 56 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 5.9 Module Restrictions Restrictions for 8-Channel Analog Input MTA (6ES7650-1AA52-2XX0) I/O Module Restrictions MTA None 8AI Module None 5.10 Voltage +/-5 V, 1 - 5 V, +/-10 V Current 0 - 20 mA, +/- 20 mA, 4 - 20 mA Typical Transmitter Connection to Field Terminals Figure 5-2 Analog Input Current Input Connection Examples (MTA I/V Jumper set to I and 2/4 Jumper set to 2 or 4 depending on transmitter type) +V +Sig PW0 PW0 I0+ 2-Wire Transmitter I0- Isolated 4-Wire Transmitter +Sig I0+ I0- -Sig SH0 SH0 -Sig -V Figure 5-3 Analog Input Voltage Input Connection Example (MTA I/V Jumper set to V and 2/4 Jumper set to 4) ZZ PW0 +Sig Voltage Source I0+ I0- -Sig SH0 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 57 8-Channel Analog Input MTA 5.11 Hardware Configuration Use the I - V jumpers to select voltage or current input signals and the 2 - 4 jumpers to select the transducer type. For voltage mode jumper 2 - 4 has to be set to 4. Configure the AI8 module to match the input signal type. See Figure 4-1 5-1 for the location of the I - V jumper and Item 12, for the location of the 2 - 4 Jumper. 5.11.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 5-4 shows addresses and process image for a redundant configuration. Figure 5-4 8-Channel Analog Input Hardware Configuration: Address Setup for Redundant Operation 58 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Input MTA 5.11.2 Inputs Select appropriate module hardware configuration settings. Select Measuring Type and Measuring Range settings to match the input signal connected to the channel inputs. Figure 5-5 shows the all the diagnostic boxes checked. Figure 5-5 8-Channel Analog Input Hardware Configuration: Inputs Setup Note * Use the AI8 MTA I - V jumpers to select voltage or current input signals. * Use the AI8 MTA 2 - 4 jumpers to select 2-wire or 4-wire mode. * Configure the AI8 module to match the input signal type. * See Figure 4-1, Item 11, for the location of the I - V Jumper and item 12 for the location if the 2 - 4 jumper. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 59 8-Channel Analog Input MTA 5.11.3 Redundancy Figure 4-65-6 shows the redundant configuration. For non-redundant operation, in the Redundancy box, select None. All other parameters should be set to user preferences. Figure 5-6 8-Channel Analog Input Hardware Configuration: Redundancy Selection 5.12 Technical Specifications for 8-Channel Analog Input Module (6ES7 331-7NF00-0AB0 / 6ES7331-7NF10-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). 60 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Output MTA 6 8-Channel Analog Output MTA Part No. 6ES7650-1AB51-2XX0 or 6ES7650-1AB50-2XX0 6.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AB51-2XX0 or 6ES7650-1AB50-2XX0), designed to interface with the Siemens ET 200M 8Channel Analog Output Module (6ES7 332-5HF00-0AB0, E-Stand 3 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. Note Drive capability for the analog output module is limited to less than 600 . 6.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication for each power supply * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 61 8-Channel Analog Output MTA 6.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has circuitry to detect the presence of voltage over 15 VDC and turn on the LED indicator. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses. Module Fuse 1 (F100) supplies the I/O module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O module plugged into J2. The channels do not require power from the I/O power supply and therefore no channel power circuitry is required. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is the current output source and CHx- is the current output sink. The I/O module outputs from J1 and J2 are diode OR'd, via CR1CR16, before connecting to CHx+ of the Field terminals. Redundant operation uses two modules with one each connected to J1 and J2, while non-redundant systems have one module connected to either J1 or J2. The field termination connector is removable for ease of wiring maintenance and is retained by friction. 6.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ000AS0), supporting eight analog output channels, interconnects the analog output termination assembly to the 8-channel analog output module (6ES7 332-5HF000AB0, E-Stand 3 or higher). See Figure 2-11. It may be necessary to modify the printed circuit board as follows: To separate channel input low from power supply common, cut and remove the jumper W200. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable. 6.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED and Module 1/2 Fuse LED are on. If both are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If Module 1/2 Fuse LED is off, check the module fuse and replace if necessary. 62 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Output MTA 6.6 8-Channel Analog Output Marshalled Termination Assembly Figure 6-1 below shows the basic parts of the 8-Channel Analog Output MTA. Figure 6-1 8-Channel Analog Output Marshalled Termination Assembly CH4+CH4- SH4 CH5+CH5- SH5 CH6+CH6- SH6 CH7+CH7- SH7 CH0+CH0- SH0 CH1+CH1- SH1 CH2+CH2- SH2 CH3+CH3- SH3 CH7 HART+ CH6 HART+ CH5 HART+ CH1 HART+ CH0 HART+ CH2 HART+ CR7 CR3 CR1 CR5 CH3 HART+ COM HART- CH4 HART+ CR16 CH7 A CH7 B CR15 CR13 CR11 CR9 CR14 CR12 CH6 A CH6 B CH5 A CH5 B CR10 CR8 CH3 A CH3 B CR4 CR2 CR6 CH1 A CH1 B CH0 A CH0 B F100 1.0A Analog Output 6ES7650-1AB51-2XX0 F101 1.0A MODULE 1 M A M B RC601 SHIELD CH2 A CH2 B MODULE 2 J3 ZR100 R100 R101 A POWER ZR101 CR104 CR105 L+ B 1 24 CH7 SHIELD 23 CH722 CH7+ 21 CH6 SHIELD 20 CH619 CH6+ 18 CH5 SHIELD 17 CH516 CH5+ 15 CH4 SHIELD 14 CH413 CH4+ 12 CH3 SHIELD 11 CH310 CH3+ 9 CH2 SHIELD 8 CH27 CH2+ 6 CH1 SHIELD 5 CH14 CH1+ 3 CH0 SHIELD 2 CH01 CH0+ 2R1 0 B POWER L+ A 2 3R1 0 7 CH4 A CH4 B W200 CUT FOR ISOLATION 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 J2 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 2 1 J1 10 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 9 0C1 0 4 1C1 0 8 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 W100 5 W101 (6ES7650-1AB51-2XX0 or 6ES7650-1AB50-2XX0) 11 6 3 Key to numbered items in Figure 6-1: Item 1 2 3 4 5 6 7 8 9 10 11 Description Input power connections Input power indicators Field wiring connections I/O module connections ( J1 & J2 ) Shield disconnect jumper ( W100 & W101 ) Module power fuses Module power indicators Output isolation jumper ( W200 ) Hart connectivity ( 1 of 8 ) I/O Module Output Test Points ( 2 of 16) Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 63 8-Channel Analog Output MTA 6.7 Technical Specifications Technical Specifications for 8-Channel Analog Output MTA (6ES7650-1AB51-2XX0 or 6ES7650-1AB50-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) 0.870 A Maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel NA Module Power 1.0A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568882) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power NA Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com 64 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Output MTA 6.8 Module Restrictions Restrictions for 8-Channel Analog Output MTA (6ES7650-1AB51-2XX0 or 6ES7650-1AB50-2XX0) I/O Module Restrictions MTA Design There is no Channel to Channel Isolation MTA Design Series diodes lower the output compliance load to less than 600 MTA Design Short Circuit to M not detected MTA Design SAO must be configured for Current Mode MTA Design Output Range: only 4-20mA & 0-20mA 1 Module Accuracy Current Output 6.9 See Module Specs Typical Load Connection to Field Terminals Figure 6-2 Connecting an Analog Output to Field Terminals TB1 + 4 - 20 mA LOAD - 1 1 CH0+ 2 CH0- 3 SH 0 4 CH1+ 5 CH1- 6 SH 1 7 CH2+ 8 CH2- 9 SH 2 10 CH3+ 11 CH3- 12 SH 3 Minimum 0, 22 mA cutoff current Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 65 8-Channel Analog Output MTA 6.10 Hardware Configuration The Standard Analog Output MTA has no jumpers that affect the Module Hardware Configuration; however, the MTA design restricts the Module output to the current mode only. Note Redundant Operation. If a redundant Analog Output Module loses power (F10x opens) or is removed from service, then the output current will drop to 50% of its value for several controller cycles. 6.10.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 6-3 shows an analog input configured for redundant operation. Figure 6-3 8-Channel Analog Output Hardware Configuration: Address Setup for Redundant Operation 66 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel Analog Output MTA 6.10.2 Outputs For normal operation set Type of Output to current (I). The +/- 20 mA output range is not possible due to the MTA Design. All other Module hardware configuration choices under the Outputs tab are left to the user. Figure 6-4 shows the Type of Output set to I and all the diagnostic options are checked. Figure 6-4 8-Channel Analog Output Hardware Configuration: Outputs set for Current Mode operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 67 8-Channel Analog Output MTA 6.10.3 Redundancy Figure 6-5 shows redundant configuration. For non-redundant operation the value of the Redundancy field should be None. All other parameters should be set to user preferences. Figure 6-5 8-Channel Analog Output Hardware Configuration: Redundancy Selection 6.11 Technical Specifications for 8-Channel Analog Output Module (6ES7 332-5HF00-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). 68 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 7 8-Channel RTD Input MTA Part No. 6ES7650-1AG51-2XX0 or 6ES7650-1AG50-2XX0 7.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AG51-2XX0 or 6ES7650-1AG50-2XX0), designed to interface with the Siemens ET 200M 8channel RTD Input Module (6ES7 331-7PF00-0AB0, E-Stand 8 or higher, & 6ES7 331-7PF01-0AB0). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 7.2 Features The following features have been incorporated into this MTA: 7.3 * LED indication of power supply condition * Module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input terminations are pluggable for easy maintenance Operation Power is supplied via the removable power connector that is retained by screws and marked L+, M. The Module 1 LED indicates the presence of voltage and F100 supplies power to the module connected to J1. The Power Monitor board option is not available on this MTA. Incoming power is sent to the module via the power fuse. Field Terminals, Mx+, Mx-, Ix+, Ix- and SHx connect to the field devices. The four field connections allow 4-wire, 3-wire, and 2-wire RTDs to be used with Mx+ and Mx-, the measurement connections, and Ix+ and Ix-, the current conducting connections. The SHx is the field cable shield connection. The field termination connections are not removable so that measurement errors can be reduced. The four channel connections connect to the I/O module input via J1. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 69 8-Channel RTD Input MTA 7.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ000AS0), supporting eight RTD input channels, interconnects the RTD input termination assembly to the 8-channel RTD input module (6ES7 331-7PF00-0AB0, E-Stand 8 or higher & 6ES7 331-7PF01-0AB0). See Figure 2-16. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100. 7.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the I/O Power LED is on. If it is off, check the I/O Module Fuse and the power supply to the MTA. 70 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel RTD Input MTA 7.6 8-Channel, RTD Input Marshalled Termination Assembly Figure 7-1 shows the basic parts of the 8-Channel RTD Input MTA. Figure 7-1 8-Channel RTD Input Marshalled Termination Assembly (6ES7650-1AG51-2XX0 or 6ES7650-1AG50-2XX0) 0C1 0 W100 4 1C1 0 7 Unused channels should short + to - J1 RTD Input 6ES7650-1AG51-2XX0 SHIELD M F100 0.5A L+ 1 MODULE 1 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1 5 2R1 0 6 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 3 1.20 CH6 SHIELD 1.19 CH6 I1.18 CH6 I+ 1.17 CH6 M1.16 CH6 M+ 1.15 CH4 SHIELD 1.14 CH4 I1.13 CH4 I+ 1.12 CH4 M1.11 CH4 M+ 1.10 CH2 SHIELD 1.9 CH2 I1.8 CH2 I+ 1.7 CH2 M1.6 CH2 M+ 1.5 CH0 SHIELD 1.4 CH0 I1.3 CH0 I+ 1.2 CH0 M1.1 CH0 M+ 2.20 CH7 SHIELD 2.19 CH7 I2.18 CH7 I+ 2.17 CH7 M2.16 CH7 M+ 2.15 CH5 SHIELD 2.14 CH5 I2.13 CH5 I+ 2.12 CH5 M2.11 CH5 M+ 2.10 CH3 SHIELD 2.9 CH3 I2.8 CH3 I+ 2.7 CH3 M2.6 CH3 M+ 2.5 CH1 SHIELD 2.4 CH1 I2.3 CH1 I+ 2.2 CH1 M2.1 CH1 M+ 2 Key to numbered items in Figure 7-1: Item Description 1 Input power connection 2 Field wiring connections 3 I/O Module connection 4 Shield disconnect jumper ( W100 ) 5 I/O module power fuse 6 I/O module power indicator 7 Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 71 8-Channel RTD Input MTA 7.7 Technical Specifications Technical Specifications for 8-Channel RTD Input MTA (6ES7650-1AG51-2XX0 or 6ES7650-1AG50-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) 0.243 A maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes TB100 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel NA Module Power 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Indicators Input Power NA Module Power Green LED on when input power available Channel Power NA Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com 72 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel RTD Input MTA 7.8 Module Restrictions Restrictions for 8-Channel RTD Input MTA (6ES7650-1AG51-2XX0 or 6ES7650-1AG50-2XX0) I/O Module Restrictions MTA Design None Module Accuracy RTD Inputs See Module Specs Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 73 8-Channel RTD Input MTA 7.9 Typical R & RTD Connection to Field Terminals Note * When connecting an RTD in 2-wire Mode there will be no resistance error correction of the field wiring. * The 3 wire connection method produces a constant offset. The temperature reading for a Platinum 100 RTD will read under by about 1C for the 3m cable and 3C for the 8m cable." * For optimum accuracy 4 wire connections are recommended.. Figure 7-2 R & RTD Connection to Field Terminals TB1 RTD 1 M0+ 2 M0- 3 I0+ 4 I0- 5 SH0 4 WIRE RTD TB1 RTD 1 M0+ 2 M0- 3 I0+ 4 I0- 5 SH0 1 M0+ 2 M0- 3 I0+ 4 I0- 5 SH0 3 WIRE RTD TB1 RTD 2 WIRE RTD 74 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel RTD Input MTA 7.10 Hardware Configuration Neither the 8-Channel RTD Module nor the MTA supports redundant operation 7.10.1 Addresses Figure 7-3 shows Input address and process image set to a user's preferences. Figure 7-3 8-Channel RTD Input Hardware Configuration: Address Setup Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 75 8-Channel RTD Input MTA 7.10.2 Inputs - Part 1 Input parameters should be set to the user preferences that are consistent with the input device being used. Figure 7-4 shows some of the various configuration options for the Interrupts, Diagnostics, and Measuring parameters. Figure 7-4 8-Channel RTD Input Hardware Configuration: Inputs - Part 1 Parameters 76 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel RTD Input MTA 7.10.3 Inputs - Part 2 Input parameters should be set to the user preferences that are consistent with the input device being used. Figure 7-5 shows Temperature Unit set to degrees Celsius but degrees Fahrenheit is also possible. All settings should be set to user preferences. Figure 7-5 8-Channel RTD Input Hardware Configuration: Inputs - Part 2 Parameters 7.11 Technical Specifications for 8-Channel RTD Input Module (6ES7 331-7PF00-0AB0 & 6ES7 331-7PF01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 77 8-Channel RTD Input MTA 78 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8 8-Channel TC Input MTA Part No. 6ES7650-1AF51-2XX0 or 6ES7650-1AF50-2XX0 8.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AF51-2XX0 or 6ES7650-1AF50-2XX0), designed to interface with the Siemens ET 200M 8Channel TC Input Module (6ES7 331-7PF10-0AB0, E-Stand 4 or higher, & 6ES7 331-7PF11-0AB0). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 8.2 Features The following features have been incorporated into this MTA: 8.3 * Built in Reference Junction Sensor * LED indication of power supply condition * Module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input terminations are pluggable for easy maintenance Operation Power is supplied via the removable power connector that is retained by screws and marked L+, M. The Module 1 LED indicates the presence of voltage and F100 supplies power to the module connected to J1. The Power Monitor board option is not available on this MTA. Incoming power is sent to the module via the power fuse. Field Terminals, TCx+, TCx-, and SHx connect to the field devices. The TCx+ and TCx- field connections allow many types of thermocouples to be used with this MTA. The SHx is the field cable shield connection. The field termination connections are not removable so that measurement errors can be reduced. The channel connections connect to the I/O module input via J1. The MTA also contains an RTD for use as a reference junction sensor. It is thermally coupled to the field terminals and is used by the Module for reference. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 79 8-Channel TC Input MTA 8.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ000AS0), supporting eight Thermocouple input channels, interconnects the Thermocouple input termination assembly to the 8-channel Thermocouple input module (6ES7 331-7PF10-0AB0, E-Stand 4 or higher & 6ES7 331-7PF11-0AB0). See Figure 8-1. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100. 8.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the I/O Power LED is on. If it is off, check the I/O Module Fuse and the power supply to the MTA. 80 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel TC Input MTA 8.6 8-Channel TC Input Marshalled Termination Assembly Figure 8-1 8-Channel TC Input Marshalled Termination Assembly (6ES7650-1AF51-2XX0 or 6ES7650-1AF50-2XX0) 0C1 0 W100 4 1C1 0 SHIELD RT1 Unused channels should short + to F100 0.5A M 8 Thermocouple Input 6ES7650-1AF51-2XX0 J1 MODULE 1 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 L+ 1 1 5 2R1 0 6 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 3 1.12 CH6 SHIELD 1.11 CH6 TC1.10 CH6 TC+ 1.9 CH4 SHIELD 1.8 CH4 TC1.7 CH4 TC+ 1.6 CH2 SHIELD 1.5 CH2 TC1.4 CH2 TC+ 1.3 CH0 SHIELD 1.2 CH0 TC1.1 CH0 TC+ 2.12 CH7 SHIELD 2.11 CH7 TC2.10 CH7 TC+ 2.9 CH5 SHIELD 2.8 CH5 TC2.7 CH5 TC+ 2.6 CH3 SHIELD 2.5 CH3 TC2.4 CH3 TC+ 2.3 CH1 SHIELD 2.2 CH1 TC2.1 CH1 TC+ 7 2 Key to numbered items in Figure 8-1 Item Description 1 Input power connection 2 Field wiring connections 3 I/O Module connection 4 Shield disconnect jumper ( W100 ) 5 I/O module power fuse 6 I/O module power indicator 7 Reference Junction Sensor (PT100) 8 Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 81 8-Channel TC Input MTA 8.7 Technical Specifications Technical Specifications for 8-Channel TC Input MTA (6ES7650-1AF51-2XX0 or 6ES7650-1AF50-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting Din Rail 35mm (deep top hat style) Power Input Voltage Input for Single Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) 0.243 A maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes TB100 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel NA Module Power 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Indicators Input Power NA Module Power Green LED on when input power available Channel Power NA Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com See the Section 8.10, Hardware Configuration, for more information. 82 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel TC Input MTA 8.8 Module Restrictions Restrictions for 8-Channel TC Input MTA (6ES7650-1AF51-2XX0 or 6ES7650-1AF50-2XX0) I/O Module Restrictions MTA Design External Junction Compensation only Module Accuracy External Compensation Accuracy 8.9 +/-0.3C or 0.6% of terminal temperature Typical Thermocouple Connection to Field Terminals Figure 8-2 Typical Thermocouple Connection to Field Terminals THERMOCOUPLE TB1 1 TC+0 2 TC-0 3 SH0 4 TC+1 5 TC-1 6 SH1 7 TC+2 8 TC-2 9 SH2 10 TC+3 11 TC-3 12 SH3 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 83 8-Channel TC Input MTA 8.10 Hardware Configuration Neither the 8-Channel Thermocouple Module nor the MTA supports redundant operation. 8.10.1 Addresses Input address and process image should be set to the user preferences. Figure 8-3 8-Channel TC Input Hardware Configuration: Address Setup 84 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel TC Input MTA 8.10.2 Inputs - Part 1 Under the Inputs - Part 1 tab the Measuring Type field must be set to TC-EL (External Compensation) or deactivated. The other settings are user preferences. Figure 8-4 shows all the TC Measuring Ranges as Type J but they can be any type or mixed as described in the TC module manual. All other settings are user preferences. Figure 8-4 8-Channel TC Input Hardware Configuration: Inputs - Part 1 Parameters Note Under the Inputs - Part 1 tab, the Measuring Type field must be set to TC-EL (External Compensation) or deactivated. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 85 8-Channel TC Input MTA 8.10.3 Inputs - Part 2 Figure 8-5 shows the Temperature Unit set to degrees Fahrenheit, but degrees Celsius is also possible. All settings should reflect user preferences. Figure 8-5 8-Channel TC Input Hardware Configuration: Inputs - Part 2 Parameters 8.11 Technical Specifications for 8-Channel TC Input Module (6ES7 331-7PF10-0AB0 & 6ES7 331-7PF11-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). 86 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 9 6-Channel F Analog Input MTA 9.1 6-Channel F Analog Input MTA Part No. 6ES7650-1AH51-5XX0 or 6ES7650-1AH50-5XX0 9.2 Description This section contains installation information and requirements for the Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AH51-5XX0 or 6ES76501AH50-5XX0), designed to interface with the Siemens ET 200M 6-Channel F Analog Input Module (6ES7 336-1HE00-0AB0, E-Stand 6 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 9.3 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * LED indication of power supply to the field device on an individual channel basis * Per channel fusing of field power * Dual connectors for redundant I/O Module operation * Diode boards and FET Switch Adapters are pluggable for maintenance * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 87 6-Channel F Analog Input MTA 9.4 Operation The Fail-Safe Analog Input MTA consists of the * Main board * Two diode boards * FET Switch Adapters The diode board marked 1 (MLFB 6ES7650-1BC51-0XX0 or 6ES7650-1BC500XX0 ) uses 6.2 VDC zener diodes. The diode board marked 2 (MLFB 6ES76501BB51-0XX0 or 6ES7650-1BB50-0XX0) uses 5.6 VDC zener diodes. The FET Switch Adapters are required to make proper operation possible under all circumstances. The two diode boards make maintenance of redundant modules possible. The diode boards plug in to the main board and can be removed for testing and maintenance without affecting operation of the input module. The FET Switch Adapters disconnect the input signals from the FAI module in the event of an I/O power failure or FAI power failure. Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module Fuse 1 (F100) supplies the I/O Module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O Module plugged into J2. Each channel has an LED to indicate the presence of power and the fuse status. If there is no power or the fuse is open, then the LED remains off. If there is power and the fuse is good, then the LED is illuminated. Since the modules can only be used with current inputs when in safety mode, there is no provision on the MTA to allow voltage input operation. Field Terminals, Channel + (Ix+), Channel - (Ix-), Sensor power (PWRx) and Shield (SHx), connect to the field devices. PWRx is the +24 VDC power feed and is fused on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. For redundant I/O Modules, the Ix- connects to the I/O modules input via J1 and J2. If both modules are present, then the diodes on boards 1 and 2 are passive, but ensure that if either module is removed for maintenance, the input signals to the remaining module are not interrupted. Redundant operation uses the MTA, two zener diode boards, two FET switch adapters, and two FAI modules. A simplified diagram of redundant use of the FAI module and MTA is shown in Figure 9-1 88 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA For a non-redundant I/O module, the Ix- connects to the I/O module input via the diodes on Diode Board 1. The diodes on Diode Board 1 conduct the signal to the non-redundant module plugged into J2. In this case the diodes on board 2 are passive. Non-redundant modules should be plugged into J2 to insure the best common-mode rejection. Non-redundant operation uses the MTA, two Zener Diode Boards, one FET Switch Adapter, and the FAI module. A simplified diagram of Non-redundant use of the FAI module and MTA is shown in Figure 9-2. Note Use of the FAI MTA for non-redundant operation requires that the FAI I/O to MTA cable be installed into J2 on the MTA. Figure 9-1 Redundant FAI Interface FAI MTA 1 1 2 6.2 V 1 J1 2 FET SWITCH 1 - 215 OHM FET SWITCH 2 CURRENT SOURCE 1 2 + FET SWITCH BOARD 2 FET SWITCH MANA FAI MODULE A J2 1 215 OHM 5.6 V 2 FET SWITCH 2 2 1 1 1 FET SWITCH BOARD 2 FET SWITCH 1 1 FET SWITCH Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 2 MANA FAI MODULE B 89 6-Channel F Analog Input MTA Figure 9-2 Non-Redundant FAI Interface CURRENT SOURCE 6.2 V J1 2 + 1 FAI MTA - J2 1 215 OHM 5.6 V 2 FET SWITCH 2 2 1 1 FAI MODULE 1 FET SWITCH BOARD 2 FET SWITCH 1 1 9.5 FET SWITCH 2 MANA Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 or 6ES7922-3BJ000AS0), supporting six analog input channels, interconnects the analog input termination assembly to the 6-channel analog input module (6ES7 336-1HE000AB0, E-Stand 4 or higher). See Figure 2-28. It may be necessary to modify the printed circuit board as follows: To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable. Note * * 90 To separate channel input low from power supply common, cut and remove the jumper W200. This will provide isolation between the all the inputs and power return. W200 should never be cut when an FAI module is connected to J1 on the MTA. Doing so will cause the input to exceed the common mode specification and will generate a common-mode diagnostic error. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.6 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED, the Module 1/2 Fuse LED, and all the Channel Fuse LEDs are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check and replace the module fuse. If the Channel Fuse LED is off, check the channel fuse and replace as necessary. Periodically the diode boards should be tested to verify that the zener diodes will operate correctly. Testing consists of connecting a DC power supply with a currentlimiting series resistor across each diode. The power supply should provide <=20 mA at 15 to 24 VDC. The voltage measured across the zener diodes on the #1 board should be the device's nominal specification of 6.2 VDC and on the #2 board should be the device's nominal specification of 5.6 VDC. The FET Switch Adapter should also be tested to insure it is operating properly. Testing consists of turning on the FET Switches, verifying that they conduct, then turning off the FET Switches and verifying that they do not conduct. Note Correct power down and power up of the FAI module and FET switches is crucial to the proper operation of the system. The proven procedure for removal and reinstallation of the FAI module is as follows: 1. Remove the MTA-I/O cable connector from the FAI module. 2. Remove the FAI module from the backplane. 3. Perform FAI module maintenance as required. 4. Reinstall the FAI module into the backplane. 5. Reinstall the MTA-I/O cable connector onto the FAI module. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 91 15 F100 0.5A SHIELD CR106 MODULE 1 M A 1 F101 0.5A A POWER 1 7 W200 CUT FOR ISOLATION P1 ZR3 PWR0 I0+ I0- SH0PWR1 I1+ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1 F2 I2- SH2PWR3 I3+ ZR5 ZR6 J2 W101 W100 J1 2 I4- SH4PWR5 I5+ I5- SH5 1.5A R6 CH5 FUSE 1.5A F5 R5 CH4 FUSE W5 DISCONNECT W4 F4 2 CH5 CONNECTHART+ P2 DISCONNECT CH4 CONNECTHART+ ZR1 ZR4 6ES7650-1BB50-0XX0 I3- SH3 PWR4 I4+ 1.5A R4 CH3 FUSE 1.5A F3 R3 CH2 FUSE W3 DISCONNECT W2 ZR3 ZR2 CH3 CONNECTHART+ P1 DISCONNECT CH2 CONNECTHART+ P2 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 I1- SH1 PWR2 I2+ 1.5A R2 CH1 FUSE 1.5A F1 R1 CH0 FUSE DISCONNECT DISCONNECT 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 CH1 CONNECTHART+ W1 W0 F0 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ZR5 ZR6 ZR1 ZR4 6ES7650-1BC50-0XX0 ZR2 CH0 CONNECTHART+ J3 13 F Analog Input 6ES7650-1AH51-5XX0 MODULE 2 R100 R101 ZR100 CR104 1C1 0 4 ZR101 CR105 14 3R1 0 5 0C1 0 COM HART- 9.7 2R1 0 L+ A M B 92 L+ B 2 B POWER 6-Channel F Analog Input MTA 6-Channel F Analog Input Marshalled Termination Assembly Figure 9-3 shows the basic parts of the 6-Channel F Analog Input MTA. Figure 9-3 6-Channel F Analog Input Marshalled Termination Assembly (6ES7650-1AH51-5XX0 or 6ES7650-1AH50-5XX0) 11 24 CH5 SHIELD 23 CH5 I22 CH5 I+ 21 CH5 POWER 20 CH4 SHIELD 19 CH4 I18 CH4 I+ 17 CH4 POWER 16 CH3 SHIELD 15 CH3 I14 CH3 I+ 13 CH3 POWER 12 CH2 SHIELD 11 CH2 I10 CH2 I+ 9 CH2 POWER 8 CH1 SHIELD 7 CH1 I6 CH1 I+ 5 CH1 POWER 4 CH0 SHIELD 3 CH0 I2 CH0 I+ 1 CH0 POWER 9 3 8 10 6 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Key to numbered items in Figure 9-3: Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Description Input power connections Input power indicators Field wiring connections I/O module connections Shield disconnect jumper ( W100 & W101 ) Module power fuses Module power fuse indicators Channel power fuse ( 1 of 6 ) Channel power fuse indicator ( 1 of 6 ) Input isolation Jumper ( W200 ) HART connectivity terminals Channel Input Disconnect Jumper ( W0 - W5 ) 6.2V Zener Diode Boards (1) 5.6V Zener Diode Boards (2) Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 93 6-Channel F Analog Input MTA 9.8 Technical Specifications Technical Specifications for 6-Channel F Analog Input MTA (6ES7650-1AH51-5XX0 or 6ES7650-1AH50-5XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) Inrush 9.368 A maximum (Includes 9.000 A for transmitter inrush) Normal 0.5 A maximum Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel 1.5 A Fast blow (Littelfuse P/N: 273 01.5) (Siemens Spare P/N: A5E01568886) Module Power 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power Green LED on when sensor power available Field Terminal Block Wire Sizes TB1 - TB3 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Max achievable Safety Integrity Level in safety mode In Accordance with IEC 61508 SIL 3 Fail-safe performance characteristics 94 Low demand mode (average probability of failure on demand) per channel PFDavg <1E-4 @60C High demand / continuous mode ( probability of a dangerous failure per hour per channel) PFH < 1E-9 Proof-test interval 20 years Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com Note When using a 1.5A channel fuse it is possible that one or more of the zener diodes on the two Zener Diode Boards may be damaged in the event of a short circuit in the field. It is recommended that the diode boards be tested or replaced in the event a 1.5A channel fuse opens. 9.9 Module Restrictions Restrictions for 6-Channel F Analog Input MTA (6ES7650-1AH51-5XX0 or 6ES7650-1AH50-5XX0) I/O Module Restrictions MTA Design Only 1 transmitter can be connected to a channel. MTA Design Current Input Range 0 - 20 mA & 4 - 20 mA Voltage Input Range None. Voltage Mode not available MTA Design: Module Vs is used to supply the FET Switch Adapter. FET Switch Adapter current consumption = 25 mA MTA Design - Redundant Operation Max Input Signal Input Current = 20.0 mA MTA Design - Redundant Operation Isolation Jumper, W200, must be connected MTA Design Worst case FAI MTA input channel voltage 4 drop = 11.4 V 2 3 Module Accuracy Current Input The MTA and an 8 meter cable add 0.3% to the error limit specification of the module for channels 0 - 3. The 3 meter cable adds 0.1%. To improve the accuracy with the MTA, use the following configuration: Module Parameter- Type of Sensor Interconnection: 2 Sensors (There is actually only one sensor connected.) Channel Parameter- Unit Value: MIN (Unit Value refers to the value returned by the F-AI module to the CPU.) 2 Maximum channel input current without generating a diagnostic error 3 See Section 8.5 4 This is calculated with an input current of 20 mA Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 95 6-Channel F Analog Input MTA 9.10 Typical Transmitter Connection to Field Terminals Figure 9-4 Transmitter Connection to Field Terminals TB1 +Sig 2 WIRE TRANSMITTER -Sig 1 TB1 PWR0 2 I0+ 3 I0- +V 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 +Sig ISOLATED 4 WIRE TRANSMITTER -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 -V TB1 +V +Sig NON-ISOLATED 4 WIRE TRANSMITTER -V 96 -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.11 Hardware Configuration Under normal operation the hardware configuration can be set up as shown in Figure 9-5 through Figure 9-8. 9.11.1 Addresses Figure 9-5 shows redundant operation, in which the Process Image blocks should be changed from the default. Non-redundant operation does not require such a change. Figure 9-5 6-Channel F Analog Input Hardware Configuration: Address Setup for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 97 6-Channel F Analog Input MTA 9.11.2 Inputs - Part 1 Figure 9-6 shows the all the diagnostic boxes checked. The Measurement type can be either 2WMT, 4WMT, or Deactivated. Figure 9-6 6-Channel F Analog Input Hardware Configuration: Inputs - Part 1 Parameters 98 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.11.3 Inputs - Part 2 Figure 9-7 shows the Safety Mode option selected. Single sensor input is shown although two sensors can be chosen. The Monitoring Time may need to be adjusted. Figure 9-7 6-Channel F Analog Input Hardware Configuration: Inputs - Part 2 Parameters Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 99 6-Channel F Analog Input MTA 9.11.4 Redundancy Figure 9-8 shows the redundant configuration. For non-redundant operation the Redundancy box should be set to None. Figure 9-8 6-Channel F Analog Input Hardware Configuration: Redundancy Setup 9.12 Technical Specifications for 6-Channel F Analog Input Module (6ES7 336-1HE00-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). 100 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.13 Zener Diode Boards Part No. 6ES7650-1BB51-0XX0 or 6ES7650-1BB50-0XX0 and 6ES7650-1BC510XX0 or 6ES7650-1BC50-0XX0 9.13.1 Description This section contains installation information and requirements for the two Siemens Zener Diode Boards. The 6.2 VDC (6ES7650-1BC51-0XX0 or 6ES7650-1BC500XX0 ) and the 5.6 VDC (6ES7650-1BB51-0XX0 or 6ES7650-1BB50-0XX0) are used on the ET200M Marshalled Termination Assembly (MTA) (6ES7650-1AH515XX0 or 6ES7650-1AH50-5XX0) designed to interface with the Siemens ET 200M 6-Channel F Analog Input Module (6ES7 336-1HE00-0AB0, E-Stand 4 or higher). Note: The two part numbers for the 5.6 V Diode Board are interchangeable. The two part numbers for the 6.2 V Diode Board are also interchangeable. Do not interchange 5.6 V Diode Boards with 6.2 V Diode Boards. 9.13.2 Operation The 6.2 VDC and the 5.6 VDC Zener Diode Board allows proper operation of the 6 Channel Failsafe Analog Input Module with the MTA. Because the FAI may only be used in current mode when used in the Safety mode, diodes are placed in parallel with the module inputs. One diode spans one channel on one module; therefore, one diode board handles one module. The diodes are normally not conducting but when a module or the interconnecting cable is removed, the diodes conduct and keep the current constant for the other module. In a redundant system none of the diodes normally conducts, but in a non-redundant system one set is always conducting. Figure 9-9 shows a simplified schematic. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 101 6-Channel F Analog Input MTA Figure 9-9 Diode Board Interfaces 6ES7 650-1AH50-5XX0 PWR0 CHANNEL FUSE 2 1 1 L+ R 22 M CHANNEL POWER TP? HART+ 1 2 WIRE TRANSMITTER SW 2 MODULE A 2 J1 L+B 1 IO+ 1 I0R+ 1 DISCONNECT 3 I0R+ ZENER 1 6.2 V V0+ 1 DIODE BOARD 1 I0+ I0- 2 MANA M 1 W200 ISOLATION 1 MODULE B 2 J2 L+B 3 I0R+ I0R+ I0- TP? HART- I0+ V0+ 1 DIODE BOARD 2 1 ZENER 1 5.6 V I0MANA M 102 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.13.3 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings The 6.2 VDC Zener Diode Board, marked 1 is plugged into J100 and J101 on the FAI MTA. It is mechanically held down by two captive screws and standoffs. See Figure 9-11. The 5.6 VDC Zener Diode Board, marked 2 is plugged into J200 and J201 on the FAI MTA. It is mechanically held down by two captive screws and standoffs. See Figure 9-12. 9.13.4 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the diodes on the diode board do not conduct. Periodic maintenance of the FAI modules requires that the diode boards operate correctly, so the diode boards should be tested before one of the redundant modules is removed from service. Figure 9-10 5.6V Diode Board Test Setup CHANNEL FUSE 2 1 L+ 24VDC POWER SUPPLY 1 FIELD TERMINAL CONNECTIONS 1K RESISTOR VOLTMETER FROM TO CH 0 PWR0 I0+ I0+ I0- CH 1 PWR1 I1+ I1+ I1- PWR2 I2+ I2+ I2- PWR3 I3+ I3+ I3- CH 4 PWR4 I4+ I4+ I4- CH 5 PWR5 I5+ I5+ I5- CHANNEL POWER R1 1000 Ohms 1 Watt TP? HART+ IO+ SW 2 1 MODULE A 2 J1 L+A I0R+ 1 DISCONNECT 3 CH 2 CH 3 M 1 TO 22 FROM R 1 CHANNEL 6ES7 650-1AH50-5XX0 PWR0 + ZENER BOARD O - 10 V VOLTMETER MANA M 6.2V ZENER MAXIMUM 6.16 V 6.82 V NOMINAL 5.6 V 6.2 V MINIMUM 5.14 V 5.58 V 2 5.6V ZENER I0- - W200 ISOLATION 1 TEST LIMITS 1 ZENER 1 5.6 v / 6.2 V JUMPER BOARD 2 I0- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 103 6-Channel F Analog Input MTA 9.14 Diode Board Assembly The two figures below show the basic parts of the diode boards. Figure 9-11 6.2V Diode Board Assembly 2 3 ZR3 ZR6 ZR5 ZR2 P1 ZR1 ZR4 6ES7650-1BC50-0XX0 P2 1 1 Key to numbered items in Figure 9-11: Item 1 2 3 104 Description P1 P2 6.2V Zener Diode ( 1 of 6 ) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Figure 9-12 5.6V Diode Board Assembly 2 ZR3 ZR6 ZR2 ZR5 ZR1 ZR4 6ES7650-1BB50-0XX0 P1 1 P2 2 3 Key to numbered items in Figure 9-12: Item 1 2 3 Description P1 P2 5.6V Zener Diode ( 1 of 6 ) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 105 6-Channel F Analog Input MTA 9.15 FET Switch Adapter Part No. 6ES7650-1BD51-0XX0 or 6ES7650-1BD50-0XX0 9.15.1 Description This section contains installation information and requirements for the Siemens FET Switch Adapter. The FET Switch Adapter (6ES7650-1BD51-0XX0 or 6ES7650-1BD50-0XX0) is used on the ET200M Marshalled Termination Assembly (MTA) (6ES7650-1AH51-5XX0 or 6ES7650-1AH50-5XX0), which interfaces with the Siemens ET 200M 6-Channel F Analog Input Module (6ES7 336-1HE00-0AB0, E-Stand 4 or higher). Note: The two part numbers are interchangeable. 9.15.2 Operation The FET Switch Adapter contains optically coupled electronic switches powered by the FAI modules VS supply. These switches break the input signal path and Mana when power is lost on the FAI module or if the power supply in the FAI module fails. See Figure 9-16. This opening in the input signal path accomplishes two things: 9.15.3 * First, if the power fails, all the electronics in the module are removed from the circuit so that they cannot affect the other, still active, module. * Second, when power is restored and the switches close, the FAI module reintegrates correctly into the configuration without causing bumps or process fluctuations. Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings The FET Switch Adapter is installed between J1 on the MTA and the interconnecting cable to the FAI Module. It should be screwed down to prevent vibration or stress from disconnecting it from the MTA. 106 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.15.4 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation the switches in the FET Switch Adapter are energized and will conduct the input signal from the MTA to the FAI module input circuitry. Periodic maintenance of the FAI modules requires that the FET Switch Adapter operate correctly, so it should be tested when the FAI module is removed from service. Figure 9-13 through Figure 9-16 show the FET Switch Adapter test setups. Figure 9-13 5.6V FET Switch adapter Opto LED Test Setup 6ES7 650-1AH50-5XX0 PWR0 CHANNEL FUSE 2 1 L+ 1 24VDC POWER SUPPLY R 22 M CHANNEL POWER 1 TP? HART+ MODULE A 1 2 J1 L+A P1 FET Switch J1 Board 1 VS SW 2 1 IO+ I0R+ 1 + P1 9 26 FET SWITCH 1 2 SW2 1 2 0 - 50 mA AMMETER SPST 19 - DISCONNECT TEST LIMITS REMOVED OPTO LED I0MANA FET SWITCH 1 2 FET SWITCH 1 2 FET OFF < 30 mA 0.0 mA 27 12 21 2 M FET ON COM HART- 1 1 W200 ISOLATION JUMPER BOARD 2 I0- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 107 6-Channel F Analog Input MTA Figure 9-14 FET Switch Adapter FET ON Test Setup 6ES7 650-1AH50-5XX0 PWR0 CHANNEL FUSE 2 1 L+ 1 24VDC POWER SUPPLY R 22 M CHANNEL POWER TP? HART+ 1 R1 1000 Ohms 1 Watt MODULE A 1 2 J1 L+A P1 SW1 shown in "OFF" position FET SWITCH shown in "OFF" position FET Switch J1 Board 1 P1 SW1 9 1 SW 2 1 IO+ I0R+ 1 FET SWITCH 1 2 SPST 26 19 2 DISCONNECT R7 1000 Ohms 1 Watt + REMOVED 0 - 1 V VOLTMETER I0- - MANA + FET SWITCH 1 2 27 FET SWITCH 1 2 12 M 0 - 1 V VOLTMETER 21 - 2 W200 ISOLATION 1 COM HART- 1 TEST LIMITS CH Mana JUMPER BOARD 2 FET ON <0.70 Volts <0.35 Volts FET OFF < 1.0 uA < 2.0 uA I0- FIELD TERMINAL CONNECTIONS CHANNEL 1K RESISTOR VOLTMETER P1 CONNECTIONS CHANNEL WIRE TO FROM TO CH 0 PWR0 I0+ I0+ I0- CH 0 19 27 CH 1 PWR1 I1+ I1+ I1- CH 1 20 28 CH 2 PWR2 I2+ I2+ I2- CH 2 38 46 CH 3 PWR3 I3+ I3+ I3- CH 3 23 47 CH 4 PWR4 I4+ I4+ I4- CH 4 40 15 CH 5 PWR5 I5+ I5+ I5- CH 5 8 32 26 R7b R7a 12 R7a VM+ Mana FROM COM HART- 108 TO FROM VM- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Figure 9-15 FET Switch Adapter FET OFF Test Setup 6ES7 650-1AH50-5XX0 PWR0 CHANNEL FUSE 1 2 L+ 1 24VDC POWER SUPPLY R R1 1000 Ohms 1 Watt 22 M + CHANNEL POWER 1 TP? HART+ 1 0 - 50 uA AMMETER MODULE A 2 J1 P1 L+A SW1 shown in "OFF" position FET SWITCH shown in "OFF" position FET Switch J1 Board 1 P1 9 SW1 26 IO+ SW I0R+ 1 2 FET SWITCH 1 1 - 19 2 DISCONNECT 1 2 SPST R7 1000 Ohms 1 Watt + REMOVED 0 - 50 uA AMMETER I0MANA FET SWITCH 1 2 27 FET SWITCH 1 2 12 - 21 2 M COM HART- 1 W200 ISOLATION 1 TEST LIMITS CH Mana JUMPER BOARD 2 FET ON <0.70 Volts <0.35 Volts FET OFF < 1.0 uA < 2.0 uA I0- FIELD TERMINAL CONNECTIONS CHANNEL 1K RESISTOR AMMETER FROM TO CH 0 PWR0 AM+ R1 I0+ CH 1 PWR1 AM+ R2 CH 2 PWR2 AM+ CH 3 PWR3 CH 4 CH 5 P1 CONNECTIONS CHANNEL WIRE FROM TO CH 0 19 27 I1+ CH 1 20 28 R3 I2+ CH 2 38 46 AM+ R4 I3+ CH 3 23 47 PWR4 AM+ R5 I4+ CH 4 40 15 PWR5 AM+ R6 I5+ CH 5 8 32 9 R7a R7b AM+ 12 AM- FROM TO Mana Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 109 6-Channel F Analog Input MTA Figure 9-16 FET Switch Adapter Assembly J1 (FEMALE DB50) P1 (MALE DB50) 6ES7650-1BD50-0XX0 REV 0 (WW/YY) 9.15.5 Technical Specifications Technical Specifications for FET Switch Adapter (6ES7650-1BD51-0XX0 or 6ES7650-1BD50-0XX0) Dimensions L x W x D - inches 2.5 x 2.75 x 0.75 L x W x D - mm 63.5 x 69.9 x 50.8 x 20 Power Use FAI Vs 25 mA Environmental 110 Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA 9.16 Input Sharing 9.16.1 Description This section contains information and requirements for input sharing between a Failsafe Analog Input module (6ES7 336-1HE00-0AB0, E-Stand 4 or higher) and a Standard Analog Input Module (6ES7 331-7NF00-0AB0, E-Stand 5 or higher), using the Siemens FAI Marshalled Termination Assembly (MTA) (6ES76501AH51-5XX0 or 6ES7650-1AH50-5XX0) and the Siemens AI Marshalled Termination Assembly (MTA) (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0). 9.16.2 Purpose Input sharing allows the transmitter signal to be distributed to both the Fail-Safe Analog Input Module and the Standard Analog Input Module. Both systems will then receive the same input data. See Section 9.16.4. 9.16.3 Operation The signal source is connected to the FAI MTA in the normal manner. The cable plugged into J1 is wired from IxR+ to Ix+ on TBy of the Standard Analog Input (SAI) MTA (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0) and the Ix- pin to Ix- on TBy of the SAI MTA. The SAI MTA input jumpers (W0 - W7) are set for current mode and the isolation jumpers (W8 - W15) are cut for each channel connected to the FAI MTA. The SAI Module is connected to the SAI MTA using the standard cable. See Table 6-1. The 6.2V zener diode board is required in position 1 on the FAI MTA. See Figure 9-18. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 111 6-Channel F Analog Input MTA 9.16.4 FAI MTA to SAI MTA Cable The FAI MTA to SAI MTA Input Sharing cable uses only 13 conductors. The FAI Channel 0 to Channel 5 input signals have been mapped to Channels 0 through 5 on the SAI MTA. Channels 6 & 7 of the SAI can be used for other inputs. The cable connections can be seen in the table below. The FAI MTA to SAI MTA Input Sharing cable is custom manufactured on a project basis. See the project manager to for more information. The assembly view of the cable can be seen in Figure 9-17. Table 9-1 FAI MTA to SAI MTA Cable FAI Channel FAI MTA Signal FAI MTA D50M Pin SAI MTA Field Terminal SAI MTA Signal SAI Channel CH 0+ I0R+ 19 TB1 PIN 2 I0+ CH 0+ CH 0- I0- 27 TB1 PIN 3 I0- CH 0- CH 1+ I1R+ 20 TB1 PIN 6 I1+ CH 1+ CH 1- I1- 28 TB1 PIN 7 I1- CH 1- CH 2+ I2R+ 38 TB1 PIN 10 I2+ CH 2+ CH 2- I2- 46 TB1 PIN 11 I2- CH 2- CH 3+ I3R+ 23 TB1 PIN 14 I3+ CH 3+ CH 3- I3- 47 TB1 PIN 15 I3 CH 3- CH 4+ I4R+ 40 TB2 PIN 2 I4+ CH 4+ CH 4- I4- 15 TB2 PIN 3 I4- CH 4- CH 5+ I5R+ 8 TB2 PIN 6 I5+ CH 5+ CH 5- I5- 16,17, 32 TB2 PIN 7 I5- CH 5- Shield Shield TB1 PIN 4 5 SH0 5 The shield connection to the SAI MTA is optional and should be investigated for safe operation before use 112 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Figure 9-17 FAI MTA to SAI MTA Interconnecting Cable Key to numbered items in Figure 9-17: Item Part Name 1 50-PIN FEMALE sub-D connector 2 Wires with crimped pins Figure 9-18 FAI SAI Input Sharing FAI MTA SAI MTA SAI MODULE 250 OHM CH IN - JUMPER 22 11 - J2 5.6 V 2 FET SWITCH 1 2 2 1 1 FAI MODULE 1 FET SWITCH BOARD 215 OHM CURRENT SOURCE J1 6.2 V 2 + 1 1 + 2 FET SWITCH 1 1 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 FET SWITCH 2 MANA 113 6-Channel F Analog Input MTA 9.16.5 Hardware Configuration FAI: Redundancy not supported. The HW configuration should be setup for Nonredundant operation. See section 9.11. SAI: The SAI MTA supports redundancy for the Standard Modules and redundant modules can be used, as selected by the user. See section 4.10. Addresses FAI: Input address and process image should be set to the user preferences. See section 9.11. SAI: Input address and process image should be set to the user preferences. See section 4.10. Inputs FAI: Set to user preferences. The Safety Mode option must always be checked. See section 9.11. SAI: Under the Inputs tab the Measuring Type should be set to 4DMU (current) with Measuring Range set to 4..20 mA. All other settings are up to the user. See section 4.10. Figure 6-19 shows SAI inputs 6 and 7 as unavailable. Because the FAI has only 6 inputs the SAI will only use 6 inputs for the sharing operation. The other two inputs can be used for other analog signals. 114 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input MTA Figure 9-19 SAI 8-Channel Analog Input Hardware Configuration: Inputs Sharing Configuration Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 115 6-Channel F Analog Input MTA Redundancy FAI: Redundancy not supported. The HW configuration should be setup for nonredundant operation. See section 9.11. SAI: The SAI MTA supports redundant and non-redundant operation. See section 4.10. Figure 9-20 shows a non-redundant SAI configuration. Figure 9-20 SAI 8-Channel Analog Input Hardware Configuration for Non-redundant Operation 116 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10 6-Channel F Analog Input HART MTA Part No. 6ES7650-1AH61-5XX0 10.1 Description This section contains installation information and requirements for the Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AH61-5XX0) designed to interface with the Siemens ET 200M 6-Channel F Analog Input HART Module (6ES7 336-4GE00-0AB0). 10.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * LED indication of power supply to the field device on an individual channel basis * Per channel fusing of field power * Dual connectors for redundant I/O Module operation * Diode boards are pluggable for maintenance * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 117 6-Channel F Analog Input HART MTA 10.3 Operation The Fail-Safe Analog Input HART (FAIH) MTA consists of the * Main board * Two diode boards The diode board marked 1 (MLFB 6ES7650-1BC51-0XX0 or 6ES7650-1BC500XX0 ) uses 6.2 VDC zener diodes. The diode board marked 2 (MLFB 6ES76501BB51-0XX0 or 6ES7650-1BB50-0XX0) uses 5.6 VDC zener diodes. The two diode boards make maintenance of redundant modules possible. The diode boards plug in to the main board and can be removed for testing and maintenance without affecting operation of the input module. Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module Fuse 1 (F100) supplies the I/O Module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O Module plugged into J2. Each channel has an LED to indicate the presence of power and the fuse status. If there is no power or the fuse is open, then the LED remains off. If there is power and the fuse is good, then the LED is illuminated. Field Terminals, Channel + (Ix+), Channel - (Ix-), Sensor power (PWRx) and Shield (SHx), connect to the field devices. PWRx is the +24 VDC power feed and is fused on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. For redundant I/O Modules, the Ix- connects to the I/O modules input via J1 and J2. If both modules are present, then the diodes on boards 1 and 2 are passive, but ensure that if either module is removed for maintenance, the input signals to the remaining module are not interrupted. Redundant operation uses the MTA, two zener diode boards, and two FAI modules. A simplified diagram of redundant use of the FAI module and MTA is shown in Figure 10-1 For a non-redundant I/O module, the Ix- connects to the I/O module input via the diodes on Diode Board 1. The diodes on Diode Board 1 conduct the signal to the non-redundant module plugged into J2. In this case the diodes on board 2 are passive. Non-redundant modules could be plugged into J1 or J2. Non-redundant operation uses the MTA, two Zener Diode Boards, and the FAI module. A simplified diagram of Non-redundant use of the FAI module and MTA is shown in Figure 10-2. Note Use of the FAIH MTA for non-redundant operation requires that the FAI I/O to MTA cable be installed into J2 on the MTA. 118 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 10-1 Redundant FAIH Interface FAIH MTA 150 OHM + FAI MODULE A 6.2 V CURRENT SOURCE J1 MANA - J2 MANA 1 5.6 V 150 OHM FAI MODULE B Figure 10-2 Non-Redundant FAI Interface FAIH MTA + J1 6.2 V CURRENT SOURCE - J2 1 5.6 V Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 150 OHM FAI MODULE MANA 119 6-Channel F Analog Input HART MTA 10.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AU0 or 6ES7922-3BJ000AU0), supporting six analog input channels, interconnects the analog input termination assembly to the 6-channel analog input module (6ES7 336-4GE000AB0). It may be necessary to modify the printed circuit board as follows: To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable. Note To separate channel input low from power supply common, cut and remove the jumper W200. This will provide isolation between the all the inputs and power return. 10.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings. Under normal operation, the A/B Power LED, the Module 1/2 Fuse LED, and all the Channel Fuse LEDs are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check and replace the module fuse. If the Channel Fuse LED is off, check the channel fuse and replace as necessary. Periodically the diode boards should be tested to verify that the zener diodes will operate correctly. Testing consists of connecting a DC power supply with a currentlimiting series resistor across each diode. The power supply should provide <=20 mA at 15 to 24 VDC. The voltage measured across the zener diodes on the #1 board should be the device's nominal specification of 6.2 VDC and on the #2 board should be the device's nominal specification of 5.6 VDC. Note Correct power down and power up of the FAI module is crucial to the proper operation of the system. The proven procedure for removal and re-installation of the FAI module is as follows: 1. Remove the MTA-I/O cable connector from the FAI module. 2. Remove the FAI module from the backplane. 3. Perform FAI module maintenance as required. 4. Reinstall the FAI module into the backplane. 5. Reinstall the MTA-I/O cable connector onto the FAI module. 120 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 15 CR106 MODULE 1 F101 0.5A A POWER 1 7 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 W200 CUT FOR ISOLATION P1 ZR3 CH0 FUSE PWR0 I0+ R1 CH1 FUSE R2 4 2 3 4 5 6 7 8 9 5 6 7 8 9 1 10 11 12 13 14 15 16 17 10 11 12 13 14 15 16 17 CH2 FUSE R3 CH3 FUSE R4 ZR5 ZR6 J2 W101 W100 J1 2 R5 CH5 FUSE R6 2 I5- SH5 1.5A MAX F5 I4- SH4PWR5 I5+ 1.5A MAX CH4 FUSE W5 DISCONNECT W4 F4 1C1 0 CH5 CONNECTHART+ P2 DISCONNECT CH4 CONNECTHART+ ZR1 ZR4 6ES7650-1BB50-0XX0 I3- SH3 PWR4 I4+ 1.5A MAX F3 I2- SH2PWR3 I3+ 1.5A MAX F2 W3 DISCONNECT W2 ZR3 ZR2 CH3 CONNECTHART+ P1 DISCONNECT CH2 CONNECTHART+ P2 I1- SH1 PWR2 I2+ 1.5A MAX F1 I0- SH0PWR1 I1+ 1.5A MAX. F0 DISCONNECT DISCONNECT 3 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 CH1 CONNECTHART+ W1 W0 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 ZR5 ZR6 ZR1 ZR4 6ES7650-1BC50-0XX0 ZR2 CH0 CONNECTHART+ J3 13 F Analog Input 6ES7650-1AH61-5XX0 MODULE 2 R100 R101 ZR100 CR104 16 F100 0.5A SHIELD M A M B 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 4 ZR101 CR105 14 3R1 0 5 0C1 0 COM HART- 10.6 2R1 0 L+ A L+ B 2 B POWER 6-Channel F Analog Input HART MTA 6-Channel F Analog Input HART Marshalled Termination Assembly Figure 10-3 shows the basic parts of the 6-Channel F Analog Input HART MTA. Figure 10-3 6-Channel F Analog Input HART Marshalled Termination Assembly (6ES7650-1AH61-5XX0) 11 24 CH5 SHIELD 23 CH5 I22 CH5 I+ 21 CH5 POWER 20 CH4 SHIELD 19 CH4 I18 CH4 I+ 17 CH4 POWER 16 CH3 SHIELD 15 CH3 I14 CH3 I+ 13 CH3 POWER 12 CH2 SHIELD 11 CH2 I10 CH2 I+ 9 CH2 POWER 8 CH1 SHIELD 7 CH1 I6 CH1 I+ 5 CH1 POWER 4 CH0 SHIELD 3 CH0 I2 CH0 I+ 1 CH0 POWER 9 12 3 8 10 6 121 6-Channel F Analog Input HART MTA Key to numbered items in Figure 10-3: Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 122 Description Input power connections Input power indicators Field wiring connections I/O module connections Shield disconnect jumper ( W100 & W101 ) Module power fuses Module power fuse indicators Channel power fuse ( 1 of 6 ) Channel power fuse indicator ( 1 of 6 ) Input isolation Jumper ( W200 ) HART connectivity terminals (1 of 7) Channel Input Disconnect Jumper ( W0 - W5 ) 6.2V Zener Diode Boards (1) 5.6V Zener Diode Boards (2) Shield Ground Stud for connecting to earth ground Connector for Power Monitor Board Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 10.7 Technical Specifications Technical Specifications for 6-Channel F Analog Input HART MTA (6ES7650-1AH61-5XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) Inrush 9.368 A maximum (Includes 9.000 A for transmitter inrush) Normal 0.5 A maximum Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel - Normal 0.1 A Fast blow (Littelfuse P/N: 273.100) (Siemens Spare P/N: A5E01568889) Individual channel - Optional - Recommended for 4 wire transmitters 1.5 A Fast blow (Littelfuse P/N: 273 01.5) (Siemens Spare P/N: A5E01568886) Module Power 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power Green LED on when sensor power available Field Terminal Block Wire Sizes TB1 - TB3 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Max achievable Safety Integrity Level in safety mode In Accordance with IEC 61508 SIL 3 Fail-safe performance characteristics Low demand mode (average probability of failure on demand) per channel PFDavg <1E-4 @ 60C High Demand continuous mode ( probability of dangerous failure per hour per channel) PFH < 1E-9 Proof-test interval 20 years Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 123 6-Channel F Analog Input HART MTA Note When using a 1.5A channel fuse it is possible that one or more of the zener diodes on the two Zener Diode Boards may be damaged in the event of a short circuit in the field. It is recommended that the diode boards be tested or replaced in the event a 1.5A channel fuse opens. Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com 10.8 Changes to the Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) This section contains changes to the I/O module specifications when it is used with the MTA. Changes for 6-Channel F Analog Input HART MTA (6ES7650-1AH61-5XX0) Transmitter Connections Only 1 transmitter can be connected to a channel. Output voltage for 2 wire transducer and cable with 22 mA transducer current 14 V @ 24 V Supply* Fail-safe Performance Characteristics Adds a dangerous undetected failure rate (2.4 FIT for 6 channels) to the FAI module in any configuration. Sensor Supply The FAI module internal sensor supply outputs are not used when using the FAIH MTA. Protection against short circuit with external sensor supply No external fuse required. The FAIH MTA limits current. * If the output voltage is not sufficient for a 2 wire transmitter, safety barrier and field wiring, it is recommended that a 4 wire transmitter be used. 124 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 10.9 Typical Transmitter Connection to Field Terminals Figure 10-4 Transmitter Connection to Field Terminals TB1 +Sig 2 WIRE TRANSMITTER -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 TB1 +V +Sig ISOLATED 4 WIRE TRANSMITTER -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 -V TB1 +V +Sig NON-ISOLATED 4 WIRE TRANSMITTER -V 10.10 -Sig 1 PWR0 2 I0+ 3 I0- 4 SH0 5 PWR1 6 I1+ 7 I1- 8 SH1 Hardware Configuration For hardware configuration refer to the manual S7-300 Automation System FailSafe Signal Modules (document number A5E00085586). 10.11 Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 125 6-Channel F Analog Input HART MTA 10.12 Zener Diode Boards Part No. 6ES7650-1BB51-0XX0 or 6ES7650-1BB50-0XX0 and 6ES7650-1BC510XX0 or 6ES7650-1BC50-0XX0 10.12.1 Description This section contains installation information and requirements for the two Siemens Zener Diode Boards. The 6.2 VDC (6ES7650-1BC51-0XX0 or 6ES7650-1BC500XX0 ) and the 5.6 VDC (6ES7650-1BB51-0XX0 or 6ES7650-1BB50-0XX0) are used on the ET200M Marshalled Termination Assembly (MTA) (6ES7650-1AH515XX0 or 6ES7650-1AH50-5XX0) designed to interface with the Siemens ET 200M 6-Channel F Analog Input HART Module (6ES7 336-4GE00-0AB0). Note: The two part numbers for the 5.6 V Diode Board are interchangeable. The two part numbers for the 6.2 V Diode Board are also interchangeable. Do not interchange 5.6 V Diode Boards with 6.2 V Diode Boards. 10.12.2 Operation The 6.2 VDC and the 5.6 VDC Zener Diode Board allows proper operation of the 6 Channel Failsafe Analog Input Module with the MTA. Diodes are placed in parallel with the module inputs. One diode spans one channel on one module; therefore, one diode board handles one module. The diodes are normally not conducting but when a module or the interconnecting cable is removed; the diodes conduct and keep the current constant for the other module. In a redundant system none of the diodes normally conducts, but in a non-redundant system one set is always conducting. Figure 10-5 shows a simplified schematic. 126 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 10-5 Diode Board Interfaces 6ES7 650-1AH61-5XX0 PWR0 CHANNEL FUSE 2 1 1 L+ R 22 M CHANNEL POWER TP? HART+ 1 2 WIRE TRANSMITTER SW 2 J1 L+B 1 IO+ MODULE A 1 2 I0R+ 1 DISCONNECT 1 W200 ISOLATION DIODE BOARD 1 I0+ 1 2 3 I0R- ZENER 1 6.2 V I0MANA M 1 MODULE B 2 J2 L+B I0R+ 3 I0R- ZENER 1 5.6 V 1 I0+ 1 I0- DIODE BOARD 2 TP? HART- I0MANA M Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 127 6-Channel F Analog Input HART MTA 10.12.3 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings The 6.2 VDC Zener Diode Board, marked 1 is plugged into J100 and J101 on the FAI MTA. It is mechanically held down by two captive screws and standoffs. See Figure 10-7. The 5.6 VDC Zener Diode Board, marked 2 is plugged into J200 and J201 on the FAI MTA. It is mechanically held down by two captive screws and standoffs. See Figure 10-8. 10.12.4 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the diodes on the diode board do not conduct. Periodic maintenance of the FAI modules requires that the diode boards operate correctly, so the diode boards should be tested before one of the redundant modules is removed from service. 128 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 10-6 5.6V Diode Board Test Setup ZENER DIODE BOARD TEST SETUP CHANNEL FUSE 1 2 L+ 24VDC POWER SUPPLY 1 FIELD TERMINAL CONNECTIONS 1K RESISTOR VOLTMETER FROM TO CH 0 PWR0 I0+ I0+ I0- CH 1 PWR1 I1+ I1+ I1- PWR2 I2+ I2+ I2- PWR3 I3+ I3+ I3- CH 4 PWR4 I4+ I4+ I4- CH 5 PWR5 I5+ I5+ I5- CHANNEL POWER R1 1000 Ohms 1 Watt TP? HART+ IO+ SW 2 1 MODULE A 2 J1 L+A I0R+ 1 DISCONNECT 3 CH 2 CH 3 M 1 TO 22 FROM R 1 CHANNEL 6ES7 650-1AH61-5XX0 PWR0 + ZENER BOARD O - 10 V VOLTMETER - MANA M 6.2V ZENER MAXIMUM 6.16 V 6.82 V NOMINAL 5.6 V 6.2 V MINIMUM 5.14 V 5.58 V 2 5.6V ZENER I0- W200 ISOLATION 1 TEST LIMITS 1 ZENER 1 5.6 v / 6.2 V JUMPER BOARD 2 I0- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 129 6-Channel F Analog Input HART MTA 10.13 Diode Board Assembly The two figures below show the basic parts of the diode boards. Figure 10-7 6.2V Diode Board Assembly 1 ZR5 ZR2 ZR1 ZR4 6ES7650-1BC51-0XX0 P1 3 P2 ZR6 ZR3 4 6 5 7 8 1 2 Key to numbered items in Figure 10-7: Item 1 2 3 4 5 6 7 8 130 Description P1 P2 6.2V Zener Diode (1 of 6) Screw Flat washer Lock Washer Standoff Retaining Washer Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 10-8 5.6V Diode Board Assembly ZR3 2 ZR5 ZR2 ZR4 ZR1 6ES7650-1BB51-0XX0 P1 3 P2 ZR6 4 6 5 7 8 2 1 Key to numbered items in Figure 10-8: Item 1 2 3 4 5 6 7 8 Description P1 P2 5.6V Zener Diode ( 1 of 6 ) Screw Flat washer Lock Washer Standoff Retaining Washer Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 131 6-Channel F Analog Input HART MTA 10.14 Input Sharing 10.14.1 Description This section contains information and requirements for input sharing between a Failsafe Analog Input module (6ES7 336-4GE00-0AB0) and a Standard Analog Input Module (6ES7 331-7NF00-0AB0, E-Stand 5 or higher), using the Siemens FAIH Marshalled Termination Assembly (MTA) (6ES7650-1AH61-5XX0 and the Siemens AI Marshalled Termination Assembly (MTA) (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0). 10.14.2 Purpose Input sharing allows the transmitter signal to be distributed to both the Fail-Safe Analog Input Module and the Standard Analog Input Module. Both systems will then receive the same input data. Figure 10-9 FAIH SAI Input Sharing FAIH MTA J1 6.2 V SAI MODULE + CH IN - JUMPER CURRENT SOURCE 250 OHM + SAI MTA - J2 1 5.6 V 132 150 OHM FAI MODULE MANA Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 10.14.3 Operation The signal source is connected to the FAIH MTA in the normal manner. The cable plugged into J1 is wired from IxR+ to Ix+ on TBy of the Standard Analog Input (SAI) MTA (6ES7650-1AA51-2XX0 or 6ES7650-1AA50-2XX0) and the Ix- pin to Ix- on TBy of the SAI MTA. The SAI MTA input jumpers (W0 - W7) are set for current mode and the isolation jumpers (W8 - W15) are cut for each channel connected to the FAIH MTA. The SAI Module is connected to the SAI MTA using the standard cable. See Table 1-2. 10.14.4 FAIH MTA to SAI MTA Cable The FAIH MTA to SAI MTA Input Sharing cable uses only 13 conductors. The FAIH Channel 0 to Channel 5 input signals have been mapped to Channels 0 through 5 on the SAI MTA. Channels 6 & 7 of the SAI can be used for other inputs. The cable connections can be seen in the table below. The FAIH MTA to SAI MTA Input Sharing cable is custom manufactured on a project basis. See the project manager to for more information. The assembly view of the cable can be seen in Figure 10-10. Table 10-1 FAIH MTA to SAI MTA Cable FAIH Channel FAIH MTA Signal FAIH MTA D50M Pin SAI MTA Signal SAI MTA Field Terminal SAI Channel CH 0+ I0R+ 19 TB1 PIN 2 I0+ CH 0+ CH 0- I0- 27 TB1 PIN 3 I0- CH 0- CH 1+ I1R+ 20 TB1 PIN 6 I1+ CH 1+ CH 1- I1- 28 TB1 PIN 7 I1- CH 1- CH 2+ I2R+ 38 TB1 PIN 10 I2+ CH 2+ CH 2- I2- 46 TB1 PIN 11 I2- CH 2- CH 3+ I3R+ 23 TB1 PIN 14 I3+ CH 3+ CH 3- I3- 47 TB1 PIN 15 I3 CH 3- CH 4+ I4R+ 40 TB2 PIN 2 I4+ CH 4+ CH 4- I4- 15 TB2 PIN 3 I4- CH 4- CH 5+ I5R+ 8 TB2 PIN 6 I5+ CH 5+ CH 5- I5- 16,17, 32 TB2 PIN 7 I5- CH 5- Shield Shield TB1 PIN 4 6 SH0 6 The shield connection to the SAI MTA is optional and should be investigated for safe operation before use Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 133 6-Channel F Analog Input HART MTA Figure 10-10 FAIH MTA to SAI MTA Interconnecting Cable Key to numbered items in Figure 10-10: Item 134 Part Name 1 50-PIN FEMALE sub-D connector 2 Wires with crimped pins Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 10.14.5 Hardware Configuration FAI: Redundancy not supported. The HW configuration should be setup for Nonredundant operation. SAI: The SAI MTA supports redundancy for the Standard Modules and redundant modules can be used, as selected by the user. See section 4.10. Addresses FAI: Input address and process image should be set to the user preferences. SAI: Input address and process image should be set to the user preferences. See section 4.10. Inputs FAI: Set to user preferences. SAI: Under the Inputs tab the Measuring Type should be set to 4DMU (current) with Measuring Range set to 4..20 mA. All other settings are up to the user. See section 4.10. Because the FAI has only 6 inputs the SAI will only use 6 inputs for the sharing operation. The other two inputs can be used for other analog signals. Redundancy FAI: Redundancy not supported. The HW configuration should be setup for nonredundant operation. SAI: The SAI MTA supports redundant and non-redundant operation. See section 4.10. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 135 11 6-Channel F Analog Input HART MTA Part No. 6ES7650-1AH62-5XX0 11.1 Description This section contains installation information and requirements for the Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AH62-5XX0) designed to interface with the Siemens ET 200M 6-Channel F Analog Input HART Module (6ES7336-4GE00-0AB0). 11.2 Features The following features have been incorporated into this MTA: 11.3 * Redundant power connections * LED indication of redundant power supply condition * LED indication of reverse polarity * Power monitor output * short circuit proofed 2-wire transducer supply per channel * Dual connectors for redundant I/O Module operation * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Connectivity for HART Handheld Terminal (HHT) per channel Modification vs 6-Channel F Analog Input MTA 6ES76501AH61-5XX0 * electronically short circuit proofed 2-wire transducer supply * no power supply supported for 4-wire transducer * Power Monitor System onboard * no changeable diode boards * one piece connectors * housing short version Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 137 6-Channel F Analog Input HART MTA 11.4 Operation Power is supplied via the two power connectors which are marked L/A+, M/A, and L/B+, M/B. Each has a green LED to indicate the presence of voltage over 15 VDC. The case of polarity reversal of the power supply is indicated by the LEDs illuminating red. The LEDs are marked A POWER and B POWER. Incoming power from A and B is diode OR'd to provide the MTA and the module power from either input source. The output from the diodes is sent to the I/O modules via the module fuses and to the channels via the transducer supplies. Module Fuse F110 (MODULE 1) supplies the I/O Module plugged into MODULE 1 and Module Fuse F160 (MODULE 2) supplies power to the I/O Module plugged into MODULE 2. An onboard Power Monitor System (PMS) is used to provide an isolated dry contact when redundant power is supplied to MTAs. Only when power is supplied to both power inputs the output contacts 1 and 2 are closed. The Power Monitor System is designed to detect only the presence or absence of power. It is not designed to detect supply voltage which is outside the specification threshold. Field Terminals, Channel + (Ix+), Channel - (Ix-), Transducer power (PWx) and Shield (SHx), connect to the field devices. PWx is the +24 VDC power feed for supplying 2-wire transducer and is short circuit proofed on a channel-by-channel basis. For redundant I/O Modules, the Ix+/- connects to the I/O modules input via MODULE 1 and MODULE 2. If both modules are present, then the Zener-diodes which are in parallel to the measuring inputs are passive, but ensure that if one module is removed for maintenance, the input signals to the remaining module are not interrupted. Redundant operation uses the MTA and two FAI modules. A simplified diagram of redundant use of the FAI module and MTA is shown in Figure 10-1 For a non-redundant I/O module, the Ix+/- connects to the I/O module input via the upper diodes. These diodes conduct the signal to the non-redundant module plugged into MODULE 2. In this case the lower diodes are passive. Non-redundant modules could be plugged into MODULE 1 or MODULE 2. Non-redundant operation uses the MTA and one FAI module. A simplified diagram of Nonredundant use of the FAI module and MTA is shown in Figure 10-2. 138 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 11-1 Redundant FAIH Interface L/A+ L/B+ - 2 wire transducer + PWx M/A M/B MTA - FAIH 2-wire supply FAIH MODULE 1 Ix+ 6.2 V + Connector MODULE 1 150 Ohm 4 wire transducer/ current source FAIH MODULE 2 - 150 Ohm Ix- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Connector MODULE 2 5.6 V 139 6-Channel F Analog Input HART MTA Figure 11-2 Non-Redundant FAI Interface L/A+ L/B+ - 2 wire transducer + PWx M/A M/B 2-wire supply 6.2 V + Connector MODULE 1 Ix+ 4 wire transducer/ current source FAIH MODULE - 150 Ohm Ix- 140 Connector MODULE 2 5.6 V Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 11.5 Installation Requirements See Section Installation, before performing any installation and observe all warnings. A common interconnecting cable (6ES7922-3BD00-0AU0 or 6ES7922-3BJ000AU0), supporting six analog input channels, interconnects the analog input termination assembly to the 6-channel analog input module (6ES7336-4GE00-0AB0). It may be necessary to modify the printed circuit board as follows: To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, X100 and X101, for the associated cable. Note To separate channel input low from power supply common, cut and remove the jumper X300. This will provide isolation between all the inputs and power return. 11.6 Maintenance See Section Maintenance before performing any maintenance and observe all warnings. Under normal operation, the A/B Power LED and the Module 1/2 Fuse LED are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check the module fuse and replace as necessary. Note Correct power down and power up of the FAI module is crucial to the proper operation of the system. The proven procedure for removal and re-installation of the FAI module is as follows: 6. Remove the MTA-I/O cable connector from the FAI module. 7. Remove the FAI module from the backplane. 8. Perform FAI module maintenance as required. 9. Reinstall the FAI module into the backplane. 10. Reinstall the MTA-I/O cable connector onto the FAI module. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 141 6-Channel F Analog Input HART MTA 11.6.1 Maintenance for 2-wire transducer supply The power supply for 2-wire transducer is individually short circuit proofed for each channel. In case of a external short circuit, provided by a faulty wiring, the current is limited up to 40 mA. The power supply circuit works in redundant mode. By this reason also in case of a internal component error the normal current range (<24mA) will be supported. Nevertheless a periodic check of the 2-wire power supply will be commended. Please notice:: This check will disable the measurement on both conducted FAIH- modules. During test both modules will provide a broken wire diagnostic. 142 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Figure 11-3 2-wire transducer supply test setup MTA - FAIH L+ + 24V Power supply + 2-wire supply PWx 2-wire transducer FAIH MODULE 1 - - Ix+ 6.2 V Connector MODULE 1 150 Ohm FAIH MODULE 2 150 Ohm Current indicator Ix- Connector MODULE 2 5.6 V M The correct function of the 2-wire transducer supply can be checked without modifying the wiring. A DC current indicator connected with the minus connector to ground (M/A or M/B) contacts PW0 ... PW5. Measured current must be 35mA ... 40mA. In case a smaller value will be measured the MTA has become defect. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 143 6-Channel F Analog Input HART MTA 11.6.2 6-Channel F Analog Input HART Marshalled Termination Assembly Figure 10-3 shows the basic parts of the 6-Channel F Analog Input HART MTA. Figure 11-4 6-Channel F Analog Input HART Marshalled Termination Assembly (6ES7650-1AH62-5XX0) 5 12 4 11 3 8 7 11 4 1 9 13 2 144 6 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Key to numbered items in Figure 10-3: Item 1 2 3 4 5 6 7 8 9 10 11 12 13 Description Input power connections (L/A+, M/A, L/B+, M/B) Input power indicators (A POWER, B POWER) Field wiring connections Output Power Monitor System (1, 2) Shield disconnect jumper ( X100, X101 ) Module power fuses (MODULE 1, MODULE 2) Module power fuse indicators Input isolation Jumper ( X300 ) HART connectivity terminals (CHx HRT+) HART connectivity ground (COM HRT-) Channel Input Disconnect Jumper ( CON/DIS ) Zener diodes Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 145 6-Channel F Analog Input HART MTA 11.7 Technical Specifications Technical Specifications for 6-Channel F Analog Input HART MTA 6ES7650-1AH62-5XX0 in use with FAIH-module 6ES7336-4GE00-0AB0 and cables 6ES7392-3Bx00-0AU0 Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels 20 mA) < 0.5 A Power Dissipation (typical) 1W Fuse Ratings Module Power 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Power output for 2-wire transducer supply Supply current for each channel typ. 20 mA Short circuit current max. 40 mA Load capability > 750 Open loop voltage max. L+ Short circuit protection electronically; individual for each channel Power Monitoring System - Optorelay Output Contact Ratings Threshold voltage ca. 15 V Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit proofed Indicators Input Power Green LED on when input power available red LED on if power supply is reversed Field Terminals Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental o o Ambient Temperature -25 C to +70 C (Horizontal Mounting) o o -25 C to +60 C (Vertical Mounting) Humidity 5% to 95% Non-condensing Approvals Maximum achievable safety class in safety mode (depends on the voting of the corresponding I/O module) SIL according to IEC 61508, DIN EN 62061 Performance Level according to EN ISO 13849-1 Category according to EN ISO 13849-1 146 1oo1 voting 1oo2 voting SIL 3 PLe Cat. 3 SIL 3 PLe Cat. 4 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Technical Specifications for 6-Channel F Analog Input HART MTA 6ES7650-1AH62-5XX0 in use with FAIH-module 6ES7336-4GE00-0AB0 and cables 6ES7392-3Bx00-0AU0 Low Demand (PFD) according to SIL 3 (per channel) High Demand (PFH) according to SIL 3 (per channel) < 1,45 E-4 Proof-test interval 20 years < 1,9 E-9 1/h Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com 11.8 Changes to the Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) This section contains changes to the I/O module specifications when it is used with the MTA. Changes for 6-Channel F Analog Input HART MTA (6ES7650-1AH61-5XX0) Transmitter Connections Only 1 transmitter can be connected to a channel. Output voltage for 2 wire transducer and cable with 22 mA transducer current @ 24 V Supply* non redundant mode: 17 V redundant mode: 14 V Fail-safe Performance Characteristics Adds a dangerous undetected failure rate 6.3 FIT for 6 channels) to the FAI module in any configuration. Sensor Supply The FAI module internal sensor supply outputs are not used when using the FAIH MTA. Protection against short circuit with MTA sensor supply No external fuse required. The FAIH MTA limits current. * If the output voltage is not sufficient for a 2 wire transmitter, safety barrier and field wiring, it is recommended that a 4 wire transmitter be used. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 147 6-Channel F Analog Input HART MTA 11.9 Typical Transmitter Connection to Field Terminals Figure 11-5 Transmitter Connection to Field Terminals +V + Sig PW0 PW1 I0+ I1+ I0I1SH0 SH1 2 wire transducer Isolated 4 wire transducer + Sig - Sig PW0 PW1 I0+ I1+ I0I1SH0 SH1 - Sig - V +V NonIsolated 4 wire transducer + Sig - Sig PW0 PW1 I0+ I1+ I0I1SH0 SH1 - V 148 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Hardware Configuration For hardware configuration refer to the manual S7-300 Automation System FailSafe Signal Modules (document number A5E00085586). 11.10 Technical Specifications for 6-Channel F ANALOG INPUT HART Module (6ES7 336-4GE00-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 149 6-Channel F Analog Input HART MTA 11.11 Input Sharing 11.11.1 Description This section contains information and requirements for input sharing between a Failsafe Analog Input module (6ES7 336-4GE00-0AB0) and a Standard Analog Input Module (6ES7 331-7NF00-0AB0, E-Stand 5 and higher or 6ES7 331-7NF100AB0, E-Stand 8 or higher), using the Siemens FAIH Marshalled Termination Assembly (MTA) (6ES7650-1AH62-5XX0 and the Siemens AI Marshalled Termination Assembly (MTA) (6ES7650-1AA52-2XX0). 11.11.2 Purpose Input sharing allows the transmitter signal to be distributed to both the Fail-Safe Analog Input Module and the Standard Analog Input Module. Both systems will then receive the same input data. Figure 11-6 FAIH SAI Input Sharing MTA - AI8 MTA - FAIH AI8 - MODULE + U 250 Ohm CH IN / U I 4 2 Connector MODULE 1 6.2 V + Connector MODULE 1 - CURRENT SOURCE FAIH MODULE - 150 Ohm Connector MODULE 2 5.6 V 150 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 11.11.3 Operation The signal source is connected to the FAIH MTA in the normal manner. The cable plugged into the connector MODULE 1 is wired from IxR+ to Ix+ and Ix- to Ix- on field connections of the Standard Analog Input MTA-AI8 (6ES7650-1AA52-2XX0). The MTA-AI8 jumpers V/I are set for current mode (I) and the jumpers 2/4 are set for 4 wire mode (4) for each channel connected to the FAIH MTA. The AI8 Module is connected to the MTA-AI8 using the standard cables. See Table 1-2. 11.11.4 FAIH MTA to SAI MTA Cable The FAIH MTA to SAI MTA Input Sharing cable uses only 13 conductors. The FAIH Channel 0 to Channel 5 input signals have been mapped to Channels 0 through 5 on the SAI MTA. Channels 6 and 7 of the SAI can be used for other inputs. The cable connections can be seen in the table below. The FAIH MTA to SAI MTA Input Sharing cable is custom manufactured on a project basis. See the project manager to for more information. The assembly view of the cable can be seen in Figure 10-10. Table 11-1 FAIH MTA to SAI MTA Cable FAIH Channel FAIH MTA Signal FAIH MTA D50M Pin SAI MTA Signal SAI MTA Field Terminal SAI Channel CH 0+ I0R+ 19 TB1 PIN 2 I0+ CH 0+ CH 0- I0- 27 TB1 PIN 3 I0- CH 0- CH 1+ I1R+ 20 TB1 PIN 6 I1+ CH 1+ CH 1- I1- 28 TB1 PIN 7 I1- CH 1- CH 2+ I2R+ 38 TB1 PIN 10 I2+ CH 2+ CH 2- I2- 46 TB1 PIN 11 I2- CH 2- CH 3+ I3R+ 23 TB1 PIN 14 I3+ CH 3+ CH 3- I3- 47 TB1 PIN 15 I3 CH 3- CH 4+ I4R+ 40 TB2 PIN 2 I4+ CH 4+ CH 4- I4- 15 TB2 PIN 3 I4- CH 4- CH 5+ I5R+ 8 TB2 PIN 6 I5+ CH 5+ CH 5- I5- 16,17, 32 TB2 PIN 7 I5- CH 5- Shield Shield TB1 PIN 4 7 SH0 7 The shield connection to the SAI MTA is optional and should be investigated for safe operation before use Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 151 6-Channel F Analog Input HART MTA Figure 11-7 FAIH MTA to SAI MTA Interconnecting Cable Key to numbered items in Figure 10-10: Item 152 Part Name 1 50-PIN FEMALE sub-D connector 2 Wires with crimped pins Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA 11.11.5 Hardware Configuration FAI: Redundancy not supported. The HW configuration should be setup for Nonredundant operation. SAI: The SAI MTA supports redundancy for the Standard Modules and redundant modules can be used, as selected by the user. See section 4.10. Addresses FAI: Input address and process image should be set to the user preferences. SAI: Input address and process image should be set to the user preferences. See section 4.10. Inputs FAI: Set to user preferences. SAI: Under the Inputs tab the Measuring Type should be set to 4DMU (current) with Measuring Range set to 4..20 mA. All other settings are up to the user. See section 4.10. Because the FAI has only 6 inputs the SAI will only use 6 inputs for the sharing operation. The other two inputs can be used for other analog signals. Figure 11-8 SAI 8-Channel Analog Input Hardware Configuration: Inputs Sharing Configuration Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 153 6-Channel F Analog Input HART MTA 154 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 6-Channel F Analog Input HART MTA Redundancy FAI: Redundancy not supported. The HW configuration should be setup for nonredundant operation. SAI: The SAI MTA supports redundant and non-redundant operation. See section 4.10. Figure 11-9 SAI 8-Channel Analog Input Hardware Configuration for Non-redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 155 16-Channel, 24 VDC Discrete Input MTA 12 16-Channel, 24 VDC Discrete Input MTA Part No. 6ES7650-1AC11-3XX0 or 6ES7650-1AC10-3XX0 12.1 Description This section contains information and requirements for Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AC11-3XX0 or 6ES7650-1AC10-3XX0), designed to interface with the Siemens ET 200M 16-Channel, 24 VDC Discrete Input Module (6ES7 321-7BH01-0AB0, E-Stand 2 or higher) Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 12.2 Features The following features have been incorporated into this MTA: 156 * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * LED indication of power supply to the field device on an individual channel basis * Per channel fusing of field power * Dual connectors for redundant I/O Module operation * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Input MTA 12.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module Fuse 1 (F100) supplies the I/O Module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O Module plugged into J2. Each channel has an LED to indicate the presence of power and the fuse status. If there is no power or the fuse is open, then the LED remains off. If there is power and the fuse is good, then the LED is illuminated. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is the +24 VDC power feed and is fused (.05A) on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The CHx- connects to the I/O modules input via J1 and J2. Redundant operation uses use two modules, one connected to J1 and the other to J2. In non-redundant systems, the module connects to either J1 or J2. 12.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings Common interconnecting cables (6ES7922-3BD00-0AM0, 6ES7922-3BJ00-0AM0, 6ES7922-3BD01-0AM0 or 6ES7922-3BJ01-0AM0), supporting 16 DI channels, interconnect the discrete input termination assembly to the 16-channel, 24 VDC discrete input module (6ES7 321-7BH01-0AA0, E-Stand 2 or higher). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable 12.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED, the Module 1/2 Fuse LED, and all the Channel Fuse LEDs are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check and replace the module fuse. If the Channel Fuse LED is off, check and replace the channel fuse. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 157 16-Channel, 24 VDC Discrete Input MTA 12.6 16-Channel, 24 VDC Discrete Input Marshalled Termination Assembly Figure 12-1 shows the basic parts of the 16-Channel, 24 VDC Discrete Input MTA. Figure 12-1 16-Channel, 24 VDC Discrete Input Marshalled Termination Assembly (6ES7650-1AC11-3XX0 or 6ES7650-1AC10-3XX0) 10 CH9+CH9- SH9CH11+ CH11-SH11CH13+ CH13-SH13CH15+ CH15-SH15 1.12 CH6 SHIELD 1.11 CH61.10 CH6+ 1.9 CH4 SHIELD 1.8 CH41.7 CH4+ 1.6 CH2 SHIELD 1.5 CH21.4 CH2+ 1.3 CH0 SHIELD 1.2 CH01.1 CH0+ 2.24 CH15 SHIELD 2.23 CH152.22 CH15+ 2.21 CH13 SHIELD 2.20 CH132.19 CH13+ 2.18 CH11 SHIELD 2.17 CH112.16 CH11+ 2.15 CH9 SHIELD 2.14 CH92.13 CH9+ CH1+CH1- SH1 CH3+CH3- SH3 CH5+CH5- SH5 CH7+CH7- SH7 CH8+CH8- SH8CH10+ CH10-SH10CH12+ CH12-SH12CH14+ CH14-SH14 .05A .05A .05A .05A .05A .05A .05A .05A .05A 1.24 CH14 SHIELD 1.23 CH141.22 CH14+ 1.21 CH12 SHIELD 1.20 CH121.19 CH12+ 1.18 CH10 SHIELD 1.17 CH101.16 CH10+ 1.15 CH8 SHIELD 1.14 CH81.13 CH8+ CH0+CH0- SH0 CH2+CH2- SH2 CH4+CH4- SH4 CH6+CH6- SH6 .05A .05A .05A .05A .05A .05A .05A F15 CH15 R16 F14 CH14 R15 F13 CH13 R14 F12 CH12 R13 F11 CH11 R12 F10 R11 CH10 F9 CH9 R10 F8 CH8 R9 F7 CH7 R8 F6 CH6 R7 F5 CH5 R6 CH4 F101 1.0A R5 F2 F1 F0 CH1 R2 CH0 F100 1.0A R3 CH2 R4 CH3 Discrete Input 6ES7650-1AC11-3XX0 MODULE 2 J3 SHIELD MODULE 1 ZR100 R100 R101 ZR101 A POWER CR104 CR105 B POWER M A 2R1 0 L+ A M B 6 L+ B 1 3R1 0 2 F4 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1 J2 J1 0C1 0 7 F3 13 13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1 9 1C1 0 4 R1 5 W101 W100 8 2.12 CH7 SHIELD 2.11 CH72.10 CH7+ 2.9 CH5 SHIELD 2.8 CH52.7 CH5+ 2.6 CH3 SHIELD 2.5 CH32.4 CH3+ 2.3 CH1 SHIELD 2.2 CH12.1 CH1+ 3 Key to numbered items in Figure 12-1: Item Description 1 2 3 4 5 6 7 8 9 10 158 Input power connections Input power indicators Field wiring connections I/O module connections Shield disconnect jumpers ( W100 & W101 ) Module power fuses Module power indicators Channel Power Fuse ( 1 of 16 ) Channel power indicator ( 1 of 16 ) Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Input MTA 12.7 Technical Specifications Technical Specifications for 16-Channel, 24 VDC Discrete Input MTA (6ES7650-1AC11-3XX0 or 6ES7650-1AC10-3XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) All Channels at +24 VDC 0.578 A maximum All Channels at 0 VDC 0.258 A maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel 0.05 A (Littelfuse P/N: 273.050) (Siemens Spare P/N: A5E01568887) Module Power 1.0 A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568882) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power Green LED on when sensor power available Field Terminal Block Wire Sizes TB1 - TB4 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 159 16-Channel, 24 VDC Discrete Input MTA 12.8 Module Restrictions Restrictions for 16-Channel, 24 VDC Discrete Input MTA (6ES7650-1AC11-3XX0 or 6ES7650-1AC10-3XX0) I/O Module Restrictions 160 MTA Design: Module Vs not used Cross circuit between channels of a channel group - not detected MTA Design: Module Vs not used Cross circuit between channels in different channel groups - not detected MTA Design: Module Vs not used The "No Sensor Supply" boxes should not be selected under: 16-Channel Discrete Input Hardware Configuration - Inputs (see Section 9.10.2) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Input MTA 12.9 Typical Transmitter Connection to Field Terminals Figure 12-2 16 Channel DI MTA Field Terminal Connection to Transmitter TB1 + INPUT SWITCH - 2 WIRE TRANSMITTER TB4 + R2 R INPUT SWITCH - 2 WIRE TRANSMITTER W/WIRE BREAK RESISTOR 16 CHANNEL DI MTA 1 CH0+ 2 CH0- 3 S0 4 CH1+ 5 CH1- 6 S1 7 CH2+ 8 CH2- 9 S2 10 CH3+ 11 CH3- 12 S3 1 CH12+ 2 CH12- 3 S12 4 CH13+ 5 CH13- 6 S13 7 CH14+ 8 CH14- 9 S14 10 CH15+ 11 CH15- 12 S15 Note The Wire Break resistor value for redundant DI modules should be between 10 K and 12 K. The Wire Break resistor value for a non-redundant DI module can be found in the S7-300 Programmable Controller Module Specifications (document number A5E00105505). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 161 16-Channel, 24 VDC Discrete Input MTA 12.10 Hardware Configuration The 16 channel Standard Discrete Input Module and its MTA support Redundant and Non-redundant operation. 12.10.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 12-3 shows a redundant configuration. Figure 12-3 16-Channel Discrete Input Hardware Configuration: Address for Redundant Configuration 162 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Input MTA 12.10.2 Inputs The inputs of the SDI module are capable of wire break detection if a resistor is wired in parallel with the sensor, the resistor should be located near the sensor. See Figure 12-4. The Wire Break option must be checked for each channel that will use this feature. Also, the No sensor supply boxes should not be checked because the sensor does not use the VS from the module as a supply. Not using VS eliminates some of the diagnostics from operating. See the "IO Module Restrictions" in the Technical Specifications table. All other options should be set for the user preferences. Figure 12-4 shows the SDI with all 16 channels using the wire break option and the No sensor supply option not selected. Figure 12-4 16-Channel Discrete Input Hardware Configuration: Inputs Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 163 16-Channel, 24 VDC Discrete Input MTA 12.10.3 Time-of-Day Stamp All of these options should be set to user preferences. Figure 12-5 16-Channel Discrete Input Hardware Configuration: Time-of-Day Stamp Options 164 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Input MTA 12.10.4 Redundancy Figure 12-6 shows a redundant SDI configuration. Figure 12-6 16-Channel Discrete Input Hardware Configuration: Redundancy Selection 12.11 Technical Specifications for 16-Channel, 24 VDC Discrete Input Module (6ES7 321-7BH01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Programmable Controller Module Specifications (document number A5E00105505). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 165 13 12/24-Channel, 24 VDC F Discrete Input MTA Part No. 6ES7650-1AK11-7XX0 or 6ES7650-1AK10-7XX0 13.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AK11-7XX0 or 6ES7650-1AK10-7XX0), designed to interface with the Siemens ET 200M 12/24Channel, 24 VDC F Discrete Input module (6ES7 326-1BK02-0AB0, E-Stand 1 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 13.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * LED indication of power supply to the field device on an individual channel basis * Per channel fusing of field power * Per channel disconnects * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 167 12/24-Channel, 24 VDC F Discrete Input MTA 13.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module Fuse 1 (F100) supplies the I/O Module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O Module plugged into J2. Each channel has an LED to indicate the presence of power, fuse, and disconnect switch status. If there is no power, or the fuse or disconnect switch is open, then the LED remains off. If there is power and the fuse is good and the disconnect switch is closed, then the LEDs are illuminated. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is the +24 VDC power feed and is fused (.05A) on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The CHx- connects to the I/O modules input via J1 and J2. Redundant operation uses two modules with one each connected to J1 and J2, while non-redundant systems have one module connected to either J1 or J2. 13.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings Common interconnecting cables (6ES7922-3BD00-0AS0 and 6ES7922-3BJ000AS0 and 6ES7 326-1BK02-0AB0), supporting the Failsafe Discrete Input channels, interconnect the discrete input termination assembly to the 12/24channel, 24 VDC Failsafe Discrete Input module (6ES7 326-1BK00-0AB0, or 6ES7 326-1BK01-0AB0, E-Stand 1 or higher). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable 13.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED and the Module 1/2 Fuse LED are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, 168 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check the channel fuse and replace as necessary. 13.6 Simplified diagram Figure 13-1 12/24-Channel, 24 VDC F Discrete Input Marshalled Termination Assembly (6ES76501AK11-7XX0 or 6ES7650-1AK10-7XX0) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 169 12/24-Channel, 24 VDC F Discrete Input MTA L/A+ L/B+ M/A M/B P M B 1L+ 1M 1Vs 2Vs DI0 DI11 CHx+ CHx- FDI Module 1 DI23 Field wiring connections - Connector MODULE 1 + 2L+ 2M 3Vs 4Vs DI12 1L+ 1M 1Vs 2Vs DI0 DI1 MTA - DO16 170 Connector MODULE 2 2L+ 2M 3Vs 4Vs DI12 FDI Module 2 DI23 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA 13.7 12/24-Channel, 24 VDC F Discrete Input Marshalled Termination Assembly The figure below shows the basic parts of the 12/24-Channel, 24 VDC F Discrete Input MTA. Figure 13-2 12/24-Channel, 24 VDC F Discrete Input Marshalled Termination Assembly (6ES7650-1AK117XX0 or 6ES7650-1AK10-7XX0) R13 R14 R15 R16 R17 R18 R7 R8 R9 R10 R11 R12 DISCONNECT OPEN SW1 R1 R2 R3 R4 R5 R6 CH0+CH0- SH0 CH2+CH2- SH2 CH4+CH4- SH4 CH6+CH6- SH6 CH8+CH8- SH8CH10+ CH10-SH10 CH12+ CH12-SH12CH14+ CH16-SH16CH18+ CH14-SH14CH16+ CH18-SH18CH20+ CH20-SH20CH22+ CH22-SH22 R19 R20 R21 R22 R23 R24 SW2 OPEN DISCONNECT CH23 FUSE CONNECT 1 2 3 4 5 6 7 8 9 10 11 12 CONNECT 1 2 3 4 5 6 7 8 9 10 11 12 .05A .05A CH22 FUSE CH21 FUSE .05A .05A CH20 FUSE CH19 FUSE .05A .05A CH18 FUSE CH17 FUSE .05A .05A CH16 FUSE CH15 FUSE .05A .05A CH14 FUSE CH13 FUSE .05A .05A CH12 FUSE CH11 FUSE .05A .05A CH10 FUSE CH9 FUSE .05A .05A CH8 FUSE CH7 FUSE .05A .05A CH6 FUSE CH5 FUSE .05A .05A CH4 FUSE CH3 FUSE .05A .05A CH2 FUSE CH1 FUSE .05A F6 F5 F3 F2 F0 F1 MODULE 1 F100 1.0A SHIELD F4 MODULE 2 F101 1.0A ZR100 R100 R101 CR104 A POWER M A CH0 FUSE F11 F10 F7 F8 F9 J3 CR106 CR105 B POWER ZR101 L+ A M B 11 L+ B 2 2R1 0 6 3R1 0 7 .05A F23 F22 F19 J2 F12 F13 F14 F15 F16 F17 F18 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 10 11 12 13 14 15 16 17 F20 F21 W101 W100 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 2 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 J1 9 -1A K 11 -7X X 0 8 t upnI et er csi D F S 6E 0567 10 HC 0 HC 1 HC 2 HC 3 HC 4 HC 5 HC 6 HC 7 HC 8 HC 9 HC 01 HC 11 1C1 0 4 HC 21 HC 31 HC 41 HC 51 HC 61 HC 71 HC 81 HC 91 HC 02 HC 12 HC 22 HC 32 0C1 0 5 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 1.36 CH22 SHIELD 1.35 CH221.34 CH22+ 1.33 CH20 SHIELD 1.32 CH201.31 CH20+ 1.30 CH18 SHIELD 1.29 CH181.28 CH18+ 1.27 CH16 SHIELD 1.26 CH161.25 CH16+ 1.24 CH14 SHIELD 1.23 CH141.22 CH14+ 1.21 CH12 SHIELD 1.20 CH121.19 CH12+ 1.18 CH10 SHIELD 1.17 CH101.16 CH10+ 1.15 CH8 SHIELD 1.14 CH81.13 CH8+ 1.12 CH6 SHIELD 1.11 CH61.10 CH6+ 1.9 CH4 SHIELD 1.8 CH41.7 CH4+ 1.6 CH2 SHIELD 1.5 CH21.4 CH2+ 1.3 CH0 SHIELD 1.2 CH01.1 CH0+ CH1+CH1- SH1 CH3+CH3- SH3 CH5+CH5- SH5 CH7+CH7- SH7 CH9+CH9- SH9CH11+ CH11-SH11 CH13+ CH13-SH13CH15+ CH19-SH19CH21+ CH15-SH15CH17+ CH17-SH17CH19+ CH21-SH21CH23+ CH23-SH23 3 F Discrete Input 6ES7650-1AK11-7XX0 2.36 CH23 SHIELD 2.35 CH232.34 CH23+ 2.33 CH21 SHIELD 2.32 CH212.31 CH21+ 2.30 CH19 SHIELD 2.29 CH192.28 CH19+ 2.27 CH17 SHIELD 2.26 CH172.25 CH17+ 2.24 CH15 SHIELD 2.23 CH152.22 CH15+ 2.21 CH13 SHIELD 2.20 CH132.19 CH13+ 2.18 CH11 SHIELD 2.17 CH112.16 CH11+ 2.15 CH9 SHIELD 2.14 CH92.13 CH9+ 2.12 CH7 SHIELD 2.11 CH72.10 CH7+ 2.9 CH5 SHIELD 2.8 CH52.7 CH5+ 2.6 CH3 SHIELD 2.5 CH32.4 CH3+ 2.3 CH1 SHIELD 2.2 CH12.1 CH1+ 171 12/24-Channel, 24 VDC F Discrete Input MTA Key to numbered items in Figure 13-: Item Description 1 2 3 4 5 6 7 8 9 10 11 Input power connections Input power indicators Field wiring connections I/O module connections Shield disconnect jumpers ( W100 & W101 ) Module power fuses Module power indicators Channel power fuse ( 1 of 24 ) Channel power indicator ( 1 of 24 ) Channel power disconnect switches ( SW1 & SW2 ) Shield Ground Stud for connecting to earth ground Switch Off the channel power disconnect switches to disconnect field power for the channel. 13.8 Technical Specifications Technical Specifications: 12/24-Channel, 24 VDC F Discrete Input MTA (6ES7650-1AK10-7XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings) All inputs at +24 VDC 1.482 A maximum All inputs at 0 VDC 1.002 A maximum Power Dissipation (typical) 3W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel 0.05 A (Littelfuse P/N: 273.050) (Siemens Spare P/N: A5E01568887) Module Power 1.0 A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568882) Indicators 172 Input Power Green LED on when input power available Module Power Green LED on when Module power available Channel Power Green LED on when sensor power available Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA Field Terminal Block Wire Sizes TB1 - TB4 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Max achievable Safety Integrity Level in safety mode In Accordance with IEC 61508 Fail-safe performance characteristics SIL 3 (no dangerous undetected failures for DI MTA) Low demand mode (average probability of failure on demand) per channel PFDavg = 0 High Demand / continuous mode ( probability of dangerous failure per hour per channel) PFH = 0 Proof-test time 20 years 13.9 Technical Specifications Technical Specifications: 12/24-Channel, 24 VDC F Discrete Input MTA (6ES7650-1AK11-7XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm (deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings) All inputs at +24 VDC 1.482 A maximum All inputs at 0 VDC 1.002 A maximum Power Dissipation (typical) 3W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel 0.05 A (Littelfuse P/N: 273.050) (Siemens Spare P/N: A5E01568887) Module Power 2.0 A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568882) Indicators Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 173 12/24-Channel, 24 VDC F Discrete Input MTA Technical Specifications: 12/24-Channel, 24 VDC F Discrete Input MTA (6ES7650-1AK11-7XX0) Input Power Green LED on when input power available Module Power Green LED on when Module power available Channel Power Green LED on when sensor power available Field Terminal Block Wire Sizes TB1 - TB4 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +70C (Horizontal mounting) -25C to +60C (Vertical mounting) Humidity 5% to 95% Non-condensing Approvals Maximum achievable safety class in safety mode (depends on the voting of the corresponding I/O module) SIL according to IEC 61508, DIN EN 62061 Performance Level according to EN ISO 13849-1 Category according to EN ISO 13849-1 1oo1 voting 1oo2 voting SIL 2 PLd Cat. 3 SIL 3 PLe Cat. 4 Low Demand (PFD) according to SIL 3 (per channel) High Demand (PFH) according to SIL 3 (per channel) 0 Proof-test time 20 years (no dangerous undetected failures for DI MTA) 0 1/h (no dangerous undetected failures for DI MTA) Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com 13.10 Module Restrictions Restrictions for 12/24-Channel, 24 VDC F Discrete Input MTA (6ES7650-1AK11-7XX0 or 6ES7650-1AK10-7XX0) I/O Module Restrictions 174 MTA Design: Connection of 2 redundant sensors to one channel is not possible MTA Design: Module Vs not used Short Circuit to L+ on the unswitched sensor line (contact open) - not detected Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA Restrictions for 12/24-Channel, 24 VDC F Discrete Input MTA (6ES7650-1AK11-7XX0 or 6ES7650-1AK10-7XX0) MTA Design: Module Vs not used Cross circuit between channels of a channel group - not detected MTA Design: Module Vs not used Cross circuit between channels in different channel groups - not detected MTA Design: Module Vs not used There is no isolation between channels or between groups of channels. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 175 12/24-Channel, 24 VDC F Discrete Input MTA 13.11 Typical Transmitter Connection to Field Terminals Figure 13-3 Field Terminal Connections for 12/24-Channel, 24 VDC F Discrete Input MTA TB1 + INPUT SWITCH 1 CH0+ 2 CH0- 3 SH0 4 CH1+ 5 CH1- 6 SH1 2 WIRE TRANSMITTER 176 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA 13.12 Hardware Configuration The 12/24 channel Fail-Safe Discrete Input Module and its MTA support Redundant and Non-redundant operation. 13.12.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 13- shows a redundant configuration. Figure 13-4 12/24-Channel Fail-Safe Discrete Input Hardware Configuration: Address set for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 177 12/24-Channel, 24 VDC F Discrete Input MTA 13.12.2 Parameters The Parameters tab of the FDI Hardware Configuration has many options that can be set by the user. The Operating mode should be set to the user preference: Standard operation or Safety mode. The F parameters are viewable but not alterable. Module parameters and Time-of-day stamp are described later. Figure 13- the tree structure of the Parameters: Figure 13-5 12/24-Channel Fail-Safe Discrete Input Hardware Configuration: Parameter Tree Structure 178 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA 13.12.3 Module Parameters Because of the MTA design some parameters must be set manually. Encoder supply The Encoder supply via module boxes for both Supply group Vs1/Vs3 and Supply group Vs2/Vs4 must NOT be checked because the sensor does not use the VS from the module as a power supply. As a result some diagnostic tests are unavailable. See Section 8.8, IO Module Restrictions for detailed information. Other options All other options should be set to user preferences. Figure 13- shows the module set for Standard operation, VS1/VS3 Encoder supply NOT checked, and Channel 0, 12 activated. Figure 13-6 12/24-Channel Fail-Safe Discrete Input Hardware Configuration: Parameter Settings Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 179 12/24-Channel, 24 VDC F Discrete Input MTA Time-of-day Stamp All of these options should be set to the user preferences, as shown in Figure 13-. Figure 13-7 12/24-Channel Fail-Safe Discrete Input Hardware Configuration: Parameters Time-of Day Stamp Settings 180 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 12/24-Channel, 24 VDC F Discrete Input MTA 13.12.4 Redundancy All of these options should be set to the user preferences. Figure 13-shows a redundant FDI configuration. Figure 13-8 12/24-Channel Fail-Safe Discrete Input Hardware Configuration: Redundancy Settings Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 181 12/24-Channel, 24 VDC F Discrete Input MTA 13.13 Technical Specifications for 12/24-Channel, 24 VDC F Discrete Input Module (6ES7 326-1BK00-0AB0 or 6ES7 326-1BK01-0AB0 or 6ES7 326-1BK02-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). 182 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA 14 10-Channel, 24 VDC F Discrete Output MTA Part No. 6ES7650-1AL11-6XX0 or 6ES7650-1AL10-6XX0 14.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AL11-6XX0 or 6ES7650-1AL10-6XX0), designed to interface with the Siemens ET 200M 10Channel, 24 VDC F Discrete Output module (6ES7 326-2BF10-0AB0, E-Stand 3 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 14.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Per channel fusing of field power * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 183 10-Channel, 24 VDC F Discrete Output MTA 14.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector (J3) for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd, in CR106, to provide the MTA and the module power from either input source. The output from CR106 is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module Fuse 1 (F100) supplies the I/O Module plugged into J1 and Module Fuse 2 (F101) supplies power to the I/O Module plugged into J2. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is the Channel Output power source and is fused (1.0A) on a channel-by-channel basis. CHx- is the output device return. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The CHx+ connects to the I/O modules input via J1 and J2. Redundant operation uses two modules with one each connected to J1 and J2. Redundant operation is achieved by connecting the diode output from each channel on different modules together. Non-redundant systems have one module connected to either J1 or J2. Connection from the MTA to the I/O Module is accomplished with a 40 pin Siemens connector wired to a D25 female connector. This cable has larger wires than the other cables because of the higher current capabilities of the module. 14.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AN0 or 6ES7922-3BJ000AN0), supporting Failsafe 10-channel Discrete outputs, interconnects the discrete output termination assembly to the 10-channel, 24 VDC discrete output module (6ES7 326-2BF10-0AB0, E-Stand 3 or higher). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, W100 and W101, for the associated cable. 184 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA 14.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED and the Module 1/2 Fuse LED are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check and replace the module fuse. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 185 10-Channel, 24 VDC F Discrete Output MTA 14.6 Simplified diagram Figure 14-1 12/24-Channel, 24 VDC F Discrete Output Marshalled Termination Assembly (6ES76501AL11-6XX0 or 6ES7650-1AL10-6XX0) L/A+ L/B+ M/A M/B P M B - DO10 Module 1 1L+ 2L+ 3L+ Connector MODULE 1 1M 2M 3M Field wiring connections Chx+ Load Chx- 1L+ 2L+ 3L+ 1M 2M 3M Connector MODULE 2 DO10 Module 2 MTA - FDO 186 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA 14.7 10-Channel, 24 VDC F Discrete Output Marshalled Termination Assembly Figure 14-2 10-Channel, 24 VDC F Discrete Output Marshalled Termination Assembly (6ES7650-1AL116XX0 or 6ES7650-1AL10-6XX0) 1.0A CR106 F100 10A CH0+CH0- SH0 CH2+CH2- SH2 CH4+CH4- SH4 CH6+CH6- SH6 CH8+CH8- SH8 F9 F8 1.0A 1.0A F7 F6 1.0A 1.0A F5 F4 1.0A 1.0A F3 F2 F1 F0 F101 10A MODULE 2 2R1 0 SHIELD MODULE 1 M A M B 9 1.0A 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1 J2 J3 R100 L+ B 6 F Discrete Output 6ES7650-1AL11-6XX0 ZR100 R101 A POWER ZR101 CR104 CR105 B POWER L+ A 1 3R1 0 2 1.0A 25 12 24 11 23 10 22 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1 J1 0C1 0 7 1.0A W101 W100 13 13 25 12 24 11 23 10 1C1 0 4 3 CH1+CH1- SH1 CH3+CH3- SH3 CH5+CH5- SH5 CH7+CH7- SH7 CH9+CH9- SH9 8 5 2.15 CH9 SHIELD 2.14 CH92.13 CH9+ 2.12 CH7 SHIELD 2.11 CH72.10 CH7+ 2.9 CH5 SHIELD 2.8 CH52.7 CH5+ 2.6 CH3 SHIELD 2.5 CH32.4 CH3+ 2.3 CH1 SHIELD 2.2 CH12.1 CH1+ 1.15 CH8 SHIELD 1.14 CH81.13 CH8+ 1.12 CH6 SHIELD 1.11 CH61.10 CH6+ 1.9 CH4 SHIELD 1.8 CH41.7 CH4+ 1.6 CH2 SHIELD 1.5 CH21.4 CH2+ 1.3 CH0 SHIELD 1.2 CH01.1 CH0+ Key to numbered items in Figure 14-2: Item Description 1 2 3 4 5 6 7 8 9 Input power connections Input power indicators Field wiring connections I/O module connectors Shield disconnect jumpers ( W100 & W101 ) Module power fuses Module power indicators Channel power fuse ( 1 of 10 ) Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 187 10-Channel, 24 VDC F Discrete Output MTA 14.8 Technical Specifications Technical Specifications: 10-Channel, 24 VDC F Discrete Output MTA (6ES7650-1AL10-6XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) All outputs ON 10.570 A maximum All outputs OFF 0.575 A normal Power Dissipation (typical) 7W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel - Normal 1.0 A (Littelfuse P/N: 273 001) (Siemens Spare P/N: A5E01568884) Individual channel - Optional 3.0 A (Littelfuse P/N: 273 003) Module Power 10 A (Schurter P/N: 0034.1526) (Siemens Spare P/N: A5E01574409) 8 Indicators Input Power Green LED on when input power available Module Power Green LED on when sensor power available Channel Power NA Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Max achievable Safety Integrity Level in safety mode In Accordance with IEC 61508 SIL 3 8 A 3.0 A fuse can be used but Group current and total channel current are limited. See module specifications under Total current of the outputs with series diode for more information 188 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA Technical Specifications: 10-Channel, 24 VDC F Discrete Output MTA (6ES7650-1AL10-6XX0) 14.9 Fail-safe performance characteristics (no dangerous undetected failures for DO MTA) Low demand mode (average probability of failure on demand) per channel PFDavg = 0 High Demand / continuous mode ( probability of dangerous failure per hour per channel) PFH = 0 Proof-test time 20 years Technical Specifications Technical Specifications: 10-Channel, 24 VDC F Discrete Output MTA (6ES7650-1AL11-6XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) All outputs ON 10.570 A maximum All outputs OFF 0.575 A normal Power Dissipation (typical) 7W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Individual channel - Normal 1.0 A (Littelfuse P/N: 273 001) (Siemens Spare P/N: A5E01568884) Individual channel - Optional 3.0 A (Littelfuse P/N: 273 003) Module Power 10 A (Schurter P/N: 0034.1526) (Siemens Spare P/N: A5E01574409) 9 Indicators Input Power Green LED on when input power available Module Power Green LED on when sensor power available Channel Power NA 9 A 3.0 A fuse can be used but Group current and total channel current are limited. See module specifications under Total current of the outputs with series diode for more information * Note derating table below Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 189 10-Channel, 24 VDC F Discrete Output MTA Technical Specifications: 10-Channel, 24 VDC F Discrete Output MTA (6ES7650-1AL11-6XX0) Field Terminal Block Wire Sizes TB1 - TB2 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +70C (Horizontal Mounting)* -25C to +60C (Vertical Mounting)* Humidity 5% to 95% Non-condensing Approvals Maximum achievable safety class in safety mode (depends on the voting of the corresponding I/O module) SIL according to IEC 61508, DIN EN 62061 Performance Level according to EN ISO 13849-1 Category according to EN ISO 13849-1 SIL 3 PLe Cat. 4 Low Demand (PFD) according to SIL 3 (per channel) High Demand (PFH) according to SIL 3 (per channel) 0 Proof-test time 20 years (no dangerous undetected failures for DO MTA) 0 1/h (no dangerous undetected failures for DO MTA) * Derating table Mounting position Maximum temperature 40 C 50 C Horizontal Vertical Total current across all channels 10 A 7A 60 C 6A 70 C 4A 60 C 6A Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.schurter.com 14.10 Module Restrictions Restrictions for 10-Channel, 24 VDC F Discrete Output MTA (6ES7650-1AL11-6XX0 or 6ES7650-1AL10-6XX0) I/O Module Restrictions 190 Module Design - Diode Outputs used See module specifications for limitations MTA Design - Isolation There is no isolation between channels or between groups of channels Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 191 10-Channel, 24 VDC F Discrete Output MTA 14.11 Typical Load Connection to Field Terminals Figure 14-3 Load Connection to Field Terminals of 10-Channel, 24 VDC F Discrete Output MTA TB1 + 24 VDC LOAD 1 CH0+ 2 CH0- 3 SH0 4 CH1+ 5 CH1- 6 SH1 - 14.12 Hardware Configuration The 10 channel Fail-Safe Discrete Output Module and its MTA support Redundant and Non-redundant operation. 14.12.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 14- is of a redundant configuration. 192 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA Figure 14-4 10-Channel Fail-Safe Discrete Output Hardware Configuration: Addresses for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 193 10-Channel, 24 VDC F Discrete Output MTA 14.12.2 Outputs The FDO MTA uses the series diode outputs from the FDO module for both redundant and non-redundant operation. This determines which diagnostics are generated. More information about these effects can be found in the I/O Restrictions section of the Technical Specifications table and the module specifications. All options should be set for the user preferences. Figure 14- shows the FDO configured for Standard Mode and all the diagnostics enabled. Figure 14-5 10-Channel Fail-Safe Discrete Output Hardware Configuration: Outputs Configured for Standard Mode with all Diagnostics Enabled 194 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 10-Channel, 24 VDC F Discrete Output MTA 14.12.3 Redundancy Figure 14- shows a redundant FDO configuration. Figure 14-6 10-Channel Fail-Safe Discrete Output Hardware Configuration: Redundancy Selections 14.13 Technical Specifications for 10-Channel, 24 VDC F Discrete Output Module (6ES7 326-2BF10-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 195 15 16-Channel, 24 VDC Discrete Output MTA Part No. 6ES7650-1AD10-2XX0 15.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AD10-2XX0), designed to interface with the Siemens ET 200M 16-Channel, 24 VDC Discrete Output module (6ES7 322-8BH01-0AB0, E-Stand 1 or higher). 15.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Per channel LED indication of output status (ON or OFF) * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 197 16-Channel, 24 VDC Discrete Output MTA 15.3 Operation Power is supplied via the removable power connector marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector for a Power Monitor board used to indicate the presence of both A and B power. See Section 14 Power Monitor Board, (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd to provide the MTA and the module power from either power source. The output from the dual diode is sent to the I/O modules via the module power fuses. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is connected through series diodes on the MTA to the output signal of each DO module (Module 1 and Module 2). CHx- is the field device return. The field termination connector is removable for ease of wiring maintenance. Redundant operation uses two I/O modules. Redundant operation is achieved by connecting the channel outputs to the series diodes on the MTA. The MTA uses the channel outputs without series diodes from the I/O module. Connection from the MTA to the I/O Module is accomplished with a 40 pin Siemens connector wired to a D25 male connector. ! 15.4 Caution The heatsink can be over 100 C. Avoid contact during servicing. Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AT0 or 6ES7922-3BJ000AT0), supporting 16-Channel Discrete outputs, interconnects the discrete output termination assembly to the 16-channel, 24 VDC discrete output module (6ES7 322-8BH01-0AB0, E-Stand 1 or higher). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper for the associated cable. See Figure 15-1. 15.5 198 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 15.6 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LEDs and the Module 1/2 Fuse LEDs are on. If an A/B Power LED is off, check the power supply to the MTA. If a Module 1/2 Fuse LED is off, check and replace the module fuse. 15.7 Component Identification Figure 15-1 16-Channel, 24 VDC Discrete Output Marshalled Termination Assembly (6ES7650-1AD102XX0) 5 8 4 3 1.24 CH14 SHIELD 1.23 CH141.22 CH14+ 1.21 CH12 SHIELD 1.20 CH121.19 CH12+ 1.18 CH10 SHIELD 1.17 CH101.16 CH10+ 1.15 CH8 SHIELD 1.14 CH81.13 CH8+ 7 6 1.12 CH6 SHIELD 1.11 CH61.10 CH6+ 1.9 CH4 SHIELD 1.8 CH41.7 CH4+ 1.6 CH2 SHIELD 1.5 CH21.4 CH2+ 1.3 CHO SHIELD 1.2 CHO1.1 CHO+ 10 2 1 11 2.24 CH15 SHIELD 2.23 CH152.22 CH15+ 2.21 CH13 SHIELD 2.20 CH132.19 CH13+ 2.18 CH11 SHIELD 2.17 CH112.16 CH11+ 2.15 CH9 SHIELD 2.14 CH92.13 CH9+ 2.12 CH7 SHIELD 2.11 CH72.10 CH7+ 2.9 CH5 SHIELD 2.8 CH52.7 CH5+ 2.6 CH3 SHIELD 2.5 CH32.4 CH3+ 2.3 CH1 SHIELD 2.2 CH12.1 CH1+ 9 Key to numbered items in Figure 15-1: Item Description 1 Input power connections (Power A, Power B) 2 Input power indicators (Power A, Power B) 3 Field wiring connections 4 I/O module connectors (Module 1, Module 2) 5 Shield disconnect jumpers (Module 1, Module 2) 6 Module power fuses, F17 and F18, (Module 1, Module 2) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 199 16-Channel, 24 VDC Discrete Output MTA Key to numbered items in Figure 15-1: Item Description 15.8 7 Module power indicators (Module 1, Module 2) 8 Channel status indicators (1 of 16) 9 Heatsink 10 Connector for Power Monitor Board 11 Ground stud for connecting shield to earth ground Technical Specifications Technical Specifications: 16-Channel, 24 VDC Discrete Output MTA (6ES7650-1AD10-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Orientation horizontal or vertical Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings) All outputs ON, maximum loads 8.3 A maximum All outputs OFF 0.26 A maximum Power Dissipation (typical) 10 W Fuse Ratings Module 10 A/125V (Bussmann P/N: GMA-10A) (Siemens Spare P/N: A5E01568881) or (Schurter P/N: 0034.1526) (Siemens Spare P/N: A5E01574409) Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Indicators Input Power Green LED on when input power available, Red LED on when power polarity is reversed Module Power Green LED on when module power available Channel Status Green LED on when channel is ON Field Connections Wire Size - US / metric 200 24 to 14 AWG / 0.2 to 2.08 mm 2 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com http://www.schurterinc.com Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 201 16-Channel, 24 VDC Discrete Output MTA 15.9 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) Specifications This section contains changes to the I/O module specifications when it is used with the MTA. Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) Specifications when used with 16-Channel, 24 VDC Discrete Output MTA (6ES7650-1AD102XX0) Isolation between groups of 4 channels No Data for Selecting an Actuator - Voltage with output ON L+ - 2.9 V minimum (L+ is supply voltage at the MTA) Total current of outputs with series diodes Not applicable, only outputs without series diodes are used. The total current per group is 2A max., as specified for the 6ES7322-8BH01 module. There are series diodes on the MTA; therefore the behavior of the 6ES73228BH01 module is like using outputs with serial diodes. This affects the applications with lamp loads and short circuit diagnostics. See 6ES7322-8BH01 module manual. Reverse polarity power supply protection Yes, see Note below. Diagnostic with short circuit between the channel output and M (common) If output signal = "0", the M short circuit Diagnostic with short circuit between the channel output and L+ (24V supply) A short circuit between the channel output and L+ produce a "wire break" diagnostic message. diagnostic message is not reported. Note Connecting one reverse polarity power supply (e.g. -24 VDC to L+A) and one correct polarity power supply (e.g. +24 VDC to L+B) will damage the MTA. 202 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 15.10 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual SIMATIC ET 200M Signal Modules for Process Automation (document number A5E00085262-4, Edition 10/2004, Entry ID: 7215812). 15.11 Typical Load Connection to Field Terminals Figure 15-2 Load Connection to Field Terminals of 16-Channel, 24 VDC Discrete Output MTA + 24 Vdc Load - CH0+ CH0SH0 CH1+ CH1SH1 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 203 16-Channel, 24 VDC Discrete Output MTA 15.12 Hardware Configuration The 16-Channel Discrete Output Module and its MTA support redundant and nonredundant operation. 15.12.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 15-3 16-Channel Discrete Output Hardware Configuration: Addresses for Redundant Operation 204 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 15.12.2 Outputs All options should be set for the user preferences. Figure 15-4 16-Channel Discrete Output Hardware Configuration: Outputs Configured with all diagnostics enabled Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 205 16-Channel, 24 VDC Discrete Output MTA 15.12.3 Redundancy Figure 15-5 16-Channel Discrete Output Hardware Configuration: Redundancy Selections 206 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16 16-Channel, 24 VDC Discrete Output MTA Part No. 6ES7650-1AD11-2XX0 16.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AD11-2XX0), designed to interface with the Siemens ET 200M 16-Channel, 24 VDC Discrete Output module (6ES7 322-8BH10-0AB0. 16.2 Features The following features have been incorporated into this MTA: 16.3 * Redundant power connections * LED indication of redundant power supply condition * LED indication of reverse polarity * Power monitor output * Dual connectors for redundant I/O Module operation * Per module power fusing * Per channel LED indication of output status (ON or OFF) * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground Operation Power is supplied via the removable power connector marked L+A, MA, and L+B, MB. Each has a green LED to indicate the presence of voltage over 15 VDC. The case of polarity reversal of the power supply is indicated by the LEDs illuminating red. The LEDs are marked A POWER and B POWER. Incoming power from A and B is diode OR'd to provide the MTA and the module power from either power source. The output from the dual diode is sent to the I/O modules via the module power fuses. An onboard Power Monitor System (PMS) is used to provide an isolated dry contact when redundant power is supplied to MTAs. Only when power is supplied to both power inputs the output contacts 1 and 2 are closed. The Power Monitor System is designed to detect only the presence or absence of power. It is not designed to detect supply voltage which is outside the specification threshold. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 207 16-Channel, 24 VDC Discrete Output MTA Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is connected to the output signal of each DO module (Module 1 and Module 2). The necessary diode decoupling for the output signals is realized onboard the Digital Output Module DO16xDC24V/0,5A and not on the MTA. CHx- is the field device return. Redundant operation uses two Digital Output Modules. Connection from the MTA to the I/O Module is accomplished with a 40 pin Siemens connector wired to a D25 male connector. ! 16.4 Caution The heat sink can be over 100 C. Avoid contact during servicing. Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AT0 or 6ES7922-3BJ000AT0), supporting 16-Channel Discrete outputs, interconnects the discrete output termination assembly to the 16-channel, 24 VDC discrete output module (6ES7 322-8BH10-0AB0. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper for the associated cable. See Figure 15-1. 16.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LEDs and the Module 1 or 2 Fuse LEDs are green illuminated. If an A/B Power LED is red illuminated or off, check the power supply to the MTA. If a Module 1 or 2 Fuse LED is off, check and replace the module fuse. 208 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA Note Status LED With a normally connected load, the green Status LED is on when the channel is switched ON, and OFF when the channel is switched off. The green Status LED is also on when the channel is switched OFF and not connected to the external load (wire break is indicated in module diagnostic). The illumination of the LED in OFF-status (when the channel is not connected to the load) can be avoided when a resistor of 10k Ohm is connected between Chx+ and Chx-. In this case the module does not provide wire break diagnostic on that channel. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 209 16-Channel, 24 VDC Discrete Output MTA 16.6 Simplified diagram Figure 166-1 16-Channel, 24 VDC Discrete Output Marshalled Termination Assembly (6ES7650-1AD112XX0) L/A+ L/B+ M/A M/B 1 & PMS 2 - DO16 Module 1 L+ Connector MODULE 1 Field wiring connections Chx+ M Load Chx- L+ Connector MODULE 2 DO16 Module 2 M MTA - DO16 210 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 16.7 Component Identification Figure 166-2 16-Channel, 24 VDC Discrete Output Marshalled Termination Assembly (6ES7650-1AD112XX0) 5 8 3 SH14 CH14CH14+ SH12 CH12CH12+ SH10 CH10CH10+ SH8 CH8CH8+ 4 7 6 SH6 CH6CH6+ SH4 CH4CH4+ SH2 CH2CH2+ SH0 CH0CH0+ 10 2 1 11 SH15 CH15CH15+ SH13 CH13CH13+ SH11 CH11CH11+ SH9 CH9CH9+ SH7 CH7CH7+ SH5 CH5CH5+ SH3 CH3CH3+ SH1 CH1CH1+ 9 Key to numbered items in Figure 15-1: Item Description 1 Input power connections (Power A, Power B) 2 Input power indicators (Power A, Power B) 3 Field wiring connections 4 I/O module connectors (Module 1, Module 2) 5 Shield disconnect jumpers (Module 1, Module 2) 6 Module power fuses, F17 and F18, (Module 1, Module 2) 7 Module power indicators (Module 1, Module 2) 8 Channel status indicators (1 of 16) 9 Heat sink Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 211 16-Channel, 24 VDC Discrete Output MTA Key to numbered items in Figure 15-1: Item Description 212 10 Output Power Monitor System 11 Ground stud for connecting shield to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 16.8 Technical Specifications Technical Specifications: 16-Channel, 24 VDC Discrete Output MTA (6ES7650-1AD11-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Orientation horizontal or vertical Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings) All outputs ON, maximum loads 8.3 A maximum All outputs OFF 0.26 A maximum Power Dissipation (typical) 7W Fuse Ratings 10 A/125V (Bussmann P/N: GMA-10A) (Siemens Spare P/N: A5E01568881) or (Schurter P/N: 0034.1526) (Siemens Spare P/N: A5E01574409) Module Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Power Monitoring System - Optorelay Output Contact Ratings Threshold voltage ca. 15 V Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit proofed Indicators Input Power Green LED on when input power available, Red LED on when power polarity is reversed Module Power Green LED on when module power available Channel Status Green LED Field Connections Wire Size - US / metric Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 24 to 14 AWG / 0.2 to 2.08 mm 2 213 16-Channel, 24 VDC Discrete Output MTA Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com http://www.schurterinc.com 214 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 16.9 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH10-0AB0) Specifications This section contains changes to the I/O module specifications when it is used with the MTA. Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH10-0AB0) Specifications when used with 16-Channel, 24 VDC Discrete Output MTA (6ES7650-1AD112XX0) Isolation between groups of 4 channels No Data for Selecting an Actuator - Voltage with output ON L+ - 2.9 V minimum (L+ is supply voltage at the MTA) Reverse polarity power supply protection Yes, see Note below. Short to P diagnostic Is suppressed with redundancy selection Note Connecting one reverse polarity power supply (e.g. -24 VDC to L+A) and one correct polarity power supply (e.g. +24 VDC to L+B) will damage the MTA. 16.10 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH10-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual SIMATIC S7-300 Module Data (document number A5E00105504-7, Edition 03/2011, Entry ID: 22091986). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 215 16-Channel, 24 VDC Discrete Output MTA 16.11 Typical Load Connection to Field Terminals Figure 166-3 Load Connection to Field Terminals of 16-Channel, 24 VDC Discrete Output MTA + load 24 V DC 0,5A CH0+ CH1+ CH0CH1SH0 SH1 CH2+ - 216 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 16.12 Hardware Configuration The 16-Channel Discrete Output Module and its MTA support redundant and nonredundant operation. 16.12.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 166-4 16-Channel Discrete Output Hardware Configuration: Addresses for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 217 16-Channel, 24 VDC Discrete Output MTA 16.12.2 Outputs All options should be set for the user preferences. Figure 166-5 16-Channel Discrete Output Hardware Configuration: Outputs Configured with all diagnostics enabled 218 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Discrete Output MTA 16.12.3 Redundancy Figure 166-6 16-Channel Discrete Output Hardware Configuration: Redundancy Selections Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 219 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Part No. 6ES7650-1AM31-6XX0 or 6ES7650-1AM30-6XX0 17.1 Description This section contains information and requirements to facilitate installation of Siemens, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly (MTA) (6ES7650-1AM31-6XX0 or 6ES7650-1AM30-6XX0), designed to interface with the Siemens ET 200M 10-Channel Failsafe Discrete Output Module (6ES7 326-2BF10-0AB0, E-Stand 3 or higher). Note: The only major difference between the two part numbers is the housing. The Anthracite Gray housing is the latest design. Functionality of both part numbers is the same. 17.2 Features The following features have been incorporated into this MTA: 220 * Form C Relay for each output * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector for a Power Monitor board used to indicate the presence of both A and B power. See Section 19, Power Monitor Board (6ES76501BA02-0XX0). Incoming power from A and B is diode OR'd to provide the MTA and the module power from either input source. The output is sent to the I/O modules via the module fuses and to the channels via the channel fuses. Module 1 Fuse supplies the I/O Module plugged into the Module 1 connector and Module 2 Fuse 2 supplies power to the I/O Module plugged into the Module 2 connector. Field Terminals, Normally Closed (NCx), Common (COMx), and Normally Open (NOx) connect to the field devices. NCx and COMx are used to provide a normally closed connection when the relay is not energized. NOx and COMx are used to provide a normally open connection when the relay is not energized. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The relay coil x connects to the I/O modules input via the channel fuse to the Module 1 and Module 2 connectors. Redundant operation uses two modules with one each connected to the Module 1 and Module 2 connectors. Redundant operation is achieved by connecting the diode output from each channel on different modules together. Non-redundant systems have one module connected to either the Module 1 or Module 2 connectors. 17.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 and 6ES7922-3BJ000AS0), supporting 10 DO channels, interconnects the discrete output termination assembly to the 10-channel, 24 VDC Failsafe discrete output module (6ES7 3262BF10-0AB0, E-Stand 3 or higher). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper, item 5, for the associated cable. See Figure 17-. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 221 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LED and the Module 1/2 Fuse LED are on. If all are off, check the power supply to MTA. If the A/B Power LED is off, check the power supply to the MTA. If the Module 1/2 Fuse LED is off, check the channel fuse and replace as necessary. Remove field power before removing or installing any device. ! 222 Warning Electrical shock hazard * An electrical shock hazard exists for Relay Output MTAs only when connected to loads with voltage > 30V rms and 42.4V peak or 60V dc * Remove power from all wires and terminals before working on equipment. * For AC voltages all channels must be the same phase. For voltages greater than 150 VDC, all channels must be of the same voltage. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.6 Simplified diagram Figure 17-1 12/24-Channel, 24 VDC F Discrete Input Marshalled Termination Assembly (6ES76501AM31-6XX0 or 6ES7650-1AM30-6XX0) L/A+ L/B+ M/A M/B P M B - DO10 Module 1 1L+ 2L+ 3L+ NO x Connector MODULE 1 COM x Field wiring connections 1M 2M 3M NC x 1L+ 2L+ 3L+ 1M 2M 3M Connector MODULE 2 DO10 Module 2 MTA - FDO Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 223 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.7 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly Figure 17- shows the basic parts of the 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA. Figure 17-2 10-Channel, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly (6ES7650-1AM30-6XX0 or 6ES7650-1AM31-6XX0) X3 CH5 D5 CH3 CH2 CH1 0.1A 1A D3 L+ A D2 M A SHIELD 1 224 2R1 0 6 10 CH0 1A M B 0.1A L+ B MODULE 1 NC9COM9NO9 NC8COM8NO8 NC7COM7NO7 0.1A R100 ZR100 R101 CR104 ZR101 MODULE 2 A POWER B POWER D4 3R1 0 CR105 7 0.1A Relay Output 6ES7650-1AM31-6XX0 0.1A 9 2 CH4 0.1A D6 NC6COM6NO6 D7 NC5COM5NO5 CH7 CH6 0.1A D8 0.1A 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 2 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 10 11 12 13 14 15 16 17 9 8 7 6 5 4 3 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 2 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 4 NC4COM4NO4 D9 D1 NC1COM1NO1 Module 2 0.1A Module 1 CH8 C100 NC3COM3NO3 0.1A D10 C101 NC0COM0NO0 5 NC2COM2NO2 CH9 0.1A 8 40 NOT USED 39 CH9 NO 38 CH9 COM 37 CH 9 NC 36 NOT USED 35 CH8 NO 34 CH8 COM 33 CH8 NC 32 NOT USED 31 CH7 NO 30 CH7 COM 29 CH 7 NC 28 NOT USED 27 CH6 NO 26 CH6 COM 25 CH6 NC 24 NOT USED 23 CH5 NO 22 CH5 COM 21 CH 5 NC 20 NOT USED 19 CH4 NO 18 CH4 COM 17 CH4 NC 16 NOT USED 15 CH3 NO 14 CH3 COM 13 CH 3 NC 12 NOT USED 11 CH2 NO 10 CH2 COM 9 CH2 NC 8 NOT USED 7 CH1 NO 6 CH1 COM 5 CH1 NC 4 NOT USED 3 CH0 NO 2 CH0 COM 1 CH0 NC 3 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Key to numbered items in Figure 17-: Item Description 1 Input power connections 2 Input power indicators 3 Field wiring connections 4 I/O module connectors 5 Shield disconnect jumpers 6 Module power fuses 7 Module power indicators 8 Module output fuse ( 1 of 10 ) 9 Relay ( 1 of 10 ) 10 Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 225 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.8 Technical Specifications Note Technical specifications differ slightly for the two MTA part numbers. Note the part number and refer to the appropriate sections below. 17.8.1 Technical Specifications for 6ES7650-1AM30-6XX0 Technical Specifications: 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES7650-1AM30-6XX0) Dimensions - See Section 1, Figure 1.3, Long Version L x W x D - inches 9.07 x 4.55 x 2.87 L x W x D - mm 230.4 x 130.9 x 73 Mounting DIN Rail 35mm ( deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected) All outputs ON 0.820 A maximum All outputs OFF 0.575 A normal Power Dissipation (typical) 7W Terminal Block Wire Sizes TB100 & TB101 Wire Size - US/ Metric 24 - 14 gauge AWG / 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Fuse Ratings Module Power 1.0 A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568881) Individual channel - Normal 0.10 A (Littelfuse P/N 273.100) (Siemens Spare P/N: A5E01568889) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power NA Field Terminal Block Wire Sizes TB1 - TB5 Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Relay Contacts Output Contacts 226 Normally Open - NO Common - C Normally Closed - NC Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Overvoltage Installation Category Category III 150V maximum Category II 250V maximum Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Max achievable Safety Integrity Level in safety mode In Accordance with IEC 61508 SIL 2 Fail-safe performance Characteristics (unprotected inductive loads should not be used for failsafe functions) Resistive and protected inductive AC loads Resistive and protected inductive DC loads Low demand mode (average probability of failure on demand) per channel. PFDavg <= 1.26E-03; Up to 5 yr proof time PFDavg <= 6.30E-03; Up to 5 yr proof time PFDavg <= 2.5E-03; Up to 10 yr proof time PFDavg <= 1.26E-02; Up to 10 yr proof time PFDavg <= 5.0E-03; Up to 20 yr proof time PFDavg <= 2.5E-02; Up to 20 yr proof time PFH <= 5.8E-08 PFH <=2.9E-07 High Demand continuous mode ( probability of dangerous failure per hour per channel) 17.8.2 Technical Specification for 6ES7650-1AM31-6XX0 Technical Specifications: 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES7650-1AM31-6XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm ( deep top hat style) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption @ 24 VDC 10 Channels Active 0.56 A Typical 5 Channels Active 0.42 A Typical Terminal Block Wire Sizes Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Power Supply Specifications See Module Specs Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 227 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Fuse Ratings Module Power 1.0 A (Bussmann P/N: GMA-1.0A) (Siemens Spare P/N: A5E01568882) Individual channel - Normal 0.10 A (Littelfuse P/N 273.100) (Siemens Spare P/N: A5E01568889) Indicators Input Power Green LED on when input power available Module Power Green LED on when module power available Channel Power NA Field Terminal Block Wire Sizes Wire Size - US 24 - 14 gauge AWG Wire Size - Metric 0,205 - 2,08 mm sq. Relay Contacts Output Contacts Normally Open - NO Common - C Normally Closed - NC (Siemens Spare P/N A5E02164558) Environmental Ambient Temperature -25C to +70C (Horizontal Mounting) -25C to +40C (Vertical Mounting) -25C to +60C (Vertical Mounting, CH5 to CH9 only) Humidity 5% to 95% Non-condensing Approvals Maximum achievable safety class in safety mode SIL according to IEC 61508, DIN EN 62061 Performance Level according to EN ISO 13849-1 Category according to EN ISO 13849-1 SIL 2 DC: PLb | AC: PLc DC: Cat. B | AC: Cat. 1 Failsafe performance characteristics Resistive and protected inductive loads (unprotected inductive loads should not be used for failsafe functions) Low Demand (PFD) according to SIL 2 (per channel) < 2,53 E-2 < 5,06 E-2 High Demand (PFH) according to SIL 2 (per channel) < 5,77 E-7 1/h (up to 10 yr proof time) (up to 20 yr proof time) Note: SIL2 requires that there is a signal change at least once a year and that the process status is read back. If a fault is detected during this function test, replace the Relay MTA module. Overvoltage Installation Category 228 Category III 150V maximum Category II 250V maximum Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Isolation between channels < -- > shield + secondary Yes (250 VAC) between the channels Yes. U< =150 V reinforced insulation U > 150 V to 250 V basic insulation Insulation test Test voltage (routine test at IEC 61131-2) Rated voltage 150V < Ue < 300V 1350 VAC/2sec (all channels to sec. + shield) Rated voltage 100V < Ue < 150V 820 VAC/2sec (between channels for 150 VDC) Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.littelfuse.com http://www.bussmann.com Relays are available as spare parts from Siemens. Relay Information can be found at: http://www.azettler.com Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 229 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.9 Module Restrictions Note Module restrictions differ slightly for the two MTA part numbers. Note the part number and refer to the appropriate sections below. 17.9.1 Module Restrictions for 6ES7650-1AM30-6XX0 Restrictions for 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES7650-1AM30-6XX0) I/O Module Restrictions Module Design - Diode Outputs used See module specifications for limitations Relay Maximum Relay Contact Ratings Resistive Load: Max Switched Power: 150 W 0r 1250 VA Max Switched Current: 5 Amps at 120 VAC - 230 VAC 5 Amps at 24 VDC 0.4 A at 120 VDC 1/4 HP @ 120 VAC motor load Coil Resistance 1200 Ohm (Nominal) Minimum Output Rating (Wetting Rating) 0.1 A at 5 VDC Relay Output Fuse None - External Fusing required Minimum operations Mechanical 30 million operations Electrical 1 x 10 at 10 A, 24 VDC or 120 VAC 5 2 x 10 at 8 A, 230 VAC 5 Relay Contact Restrictions 230 Relay Output Fusing Fuses for the relay output connection must be provided externally to the MTA Relay Voltage Restrictions For voltages up to 150 VDC channels may be mixed mode. For voltages greater than 150 VDC, all channels must be of the same voltage. For AC voltages all channels must be the same phase. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.9.2 Module Restrictions for 6ES7650-1AM31-6XX0 Restrictions for 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES7650-1AM31-6XX0) I/O Module Restrictions Module Design - Diode Outputs used See module specifications for limitations Relay Maximum Relay Contact Ratings Resistive Load: Max Switched Power: 120 W or 1150 VA Max Switched Current: 5 Amps at 120 VAC - 230 VAC 5 amps at 24 VDC 0.4 A at 120 VDC 1/4 HP @ 120 VAC motor load UL Contact Ratings: 0.7A / 24 VDC resistive 5A / 277 VAC resistive R300 B300 Coil Resistance 810 Ohm (Nominal) Minimum Output Rating (Wetting Rating) 0.1 A at 5 VDC Relay Output Fuse None - External Fusing required Minimum operations Mechanical 10 million operations Electrical 1 x 105 at 5 A, 230 VAC Resistive Load Relay Contact Restrictions Relay Output Fusing Fuses for the relay output connection must be provided externally to the MTA Relay Voltage Restrictions For voltages up to 150 VDC channels may be mixed mode. For voltages greater than 150 VDC, all channels must be of the same voltage. For AC voltages all channels must be the same phase. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 231 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.10 Typical Load Connection to Field Terminals Figure 17-3 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Load Connection to Field Terminals 120 - 230 VAC TB1 120 - 230 VAC LOAD 2 1 NC 0 2 COM 0 3 NO 0 4 1 FUSE 5 NC 1 6 COM 1 7 NO 1 8 LOAD POWERED WHEN OUTPUT ENERGIZED 120 - 230 VAC 1 TB1 FUSE 120 - 230 VAC LOAD 1 NC 0 2 COM 0 3 NO 0 2 4 5 NC 1 6 COM 1 7 NO 1 8 LOAD POWERED WHEN OUTPUT DE-ENERGIZED Note 232 * Fuse is external to the MTA and not included. * Fuse should be sized appropriately for the load. * Only the NO connection shall be used in safety related applications. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.11 Hardware Configuration The 10 channel Fail-Safe Discrete Output Module and its Relay Output MTA support Redundant and Non-redundant operation. 17.11.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 17- shows a redundant configuration. Figure 17-4 10-Channel Fail-Safe Discrete Output Hardware Configuration: Addresses set for Redundant Operation Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 233 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.11.2 Outputs The Relay Output MTA uses the series diode outputs from the FDO module for both redundant and non-redundant operation. This determines which diagnostics are generated. More information about these effects can be found in the I/O Restrictions section of the Technical Specifications table and the module specifications. All options should be set to user preferences. Figure 17- shows the FDO configured for Standard Mode and all the diagnostics enabled. Figure 17-5 10-Channel Fail-Safe Discrete Output Hardware Configuration: Outputs Configured for Standard Mode 234 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Failsafe 10-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 17.11.3 Redundancy Figure 17- shows a redundant FDO configuration. Figure 17-6 10-Channel Fail-Safe Discrete Output Hardware Configuration: Redundancy Selections 17.12 Technical Specifications for 10-Channel, 24 VDC F Discrete Output Module (6ES7 326-2BF10-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual S7-300 Automation System Fail-Safe Signal Modules (document number A5E00085586). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 235 18 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Part No. 6ES7650-1AM30-3XX0 18.1 Description This section contains information and requirements to facilitate installation of Siemens, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly (MTA) (6ES7650-1AM30-3XX0), designed to interface with the Siemens ET 200M 16-Channel Discrete Output Module (6ES7 322-8BH01-0AB0, E-Stand 1 or higher). 18.2 Features The following features have been incorporated into this MTA: * Form C Relay for each output * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Per channel LED indication of output status (ON or OFF) * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 237 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.3 Operation Power is supplied via the removable power connector marked L+A, MA, and L+B, MB. Each has a LED to indicate the presence of voltage over 15 VDC. The LEDs are marked A POWER and B POWER. There is also a connector for a Power Monitor board used to indicate the presence of both A and B power. See Section 13 Power Monitor Board, (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd to provide the MTA and the module power from either power source. The output from the dual diode is sent to the I/O modules via the module power fuses. Field Terminals, Normally Closed (NCx), Common (COMx), and Normally Open (NOx) connect to the field devices. NCx and COMx are used to provide a normally closed connection when the relay is not energized. NOx and COMx are used to provide a normally open connection when the relay is not energized. The field termination connector is removable for ease of wiring. The relay coil x connects to the I/O module. Redundant operation uses two I/O modules. Redundant operation is achieved by connecting the diode output from each channel on different I/O modules together. Non-redundant systems have one I/O module connected. 18.4 Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD00-0AS0 and 6ES7922-3BJ000AS0), supporting 16 DO channels, interconnects the relay output termination assembly to the 16-channel, 24 VDC Failsafe discrete output module (6ES7 3228BH01-0AB0, E-Stand 1 or higher). Note 238 To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumper for the associated cable. See figure 15.1. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LEDs and the Module 1/2 Fuse LEDs are on. If all are off, check the power supply to MTA. If the A/B Power LEDs are off, check the power supply to the MTA. If the Module 1/2 Fuse LEDs are off, check the channel fuse and replace as necessary. The relays are socketed to allow replacement in the field. A relay may be replaced in non hazardous locations with power applied to the MTA (see warning below). Only the channel associated with that relay will be affected. Some relay positions have near-by components that prevent finger access. The use of long-nose pliers will be needed for those locations. See figure 15-1. Replacement of a relay can be facilitated by removing the cable connectors and frame. Reference figure 1-2 for information on the frame. It may also be helpful to unplug the field connector adjacent to the relay that you are replacing. Note ! Multiple simultaneous channel short circuits or overloads may cause the module power fuse (on the MTA) to open. Repair the channels short circuits and overloads as soon as possible. Warning Electrical shock hazard * An electrical shock hazard exists for Relay Output MTAs only when connected to loads with voltage > 30V rms and 42.4V peak or 60V dc * Remove power from all wires and terminals before working on equipment. * For voltages greater than 150 VDC, all channels must be of the same voltage. For AC voltages all channels must be the same phase for the channels in one group. There can be different phases between groups. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 239 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.6 Component Identification Figure 18-1 16-Channel, 24-150 VDC/120-230 VAC Relay Output Marshalled Termination Assembly (6ES7650-1AM30-3XX0). Shown without cover and frame. Reference figure 1-2 for cover and frame information. TO REMOVE RELAY PUSH PLASTIC CLIP TO THE SIDE AND USE NEEDLE NOSE PLYERS TO GRIP RELAY AND REMOVE 9 2.24 CH15 COM 2.23 CH15 NC 2.22 CH15 NO 8 1.24 CH14 COM 1.23 CH14 NC 5 1.22 CH114 NO 2.21 CH13 COM 2.20 CH13 NC 2.19 CH13 NO 1.21 CH12 COM MODULE 2 4 MODULE 1 1.20 CH12 NC 1.19 CH12 NO 2.18 CH11 COM 2.17 CH11 NC 2.16 CH11 NO 1.18 CH10 COM 1.17 CH10 NC 1.16 CH10 NO 2.15 CH9 COM 2.14 CH9 NC 2.13 CH9 NO 1.15 CH8 COM 11 1.14 CH8 NC 2.12 CH7 COM 1.13 CH8 NO 2.11 CH7 NC 2.10 CH7 NO 1.12 CH6 COM 1.11 CH6 NC 7 1 2 1.10 CH6 NO 2.7 CH5 NO 1.9 CH4 COM 1.8 CH4 NC 2.6 CH3 COM 1.7 CH4 NO 2.5 CH3 NC 2.4 CH3 NO 1.6 CH2 COM 1.5 CH2 NC 1.4 CH2 NO 10 2.9 CH5 COM 2.8 CH5 NC 2.3 CH1 COM 2.2 CH1 NC 2.1 CH1 NO 1.3 CH0 COM 1.2 CH0 NC 6 240 1.1 CH0 NO 3 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Key to numbered items in Figure 18-1: Item Description 1 Input power connections (Power A, Power B) 2 Input power indicators (Power A, Power B) 3 Field wiring connections 4 I/O module connectors (Module 1, Module 2) 5 Shield disconnect jumpers (Module 1, Module 2) 6 Module power fuses (Module 1, Module 2) 7 Module power indicators (Module 1, Module 2) 8 Channel status indicators (1 of 16) 9 Relay ( 1 of 16 ) 10 Ground stud for connecting shield to earth ground 11 Power Monitor Board (Optional) Connector Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 241 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.7 Technical Specifications Technical Specifications: 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES76501AM30-3XX0) Dimensions - See Section 1, Figure 1.3, Long Version Mounting DIN Rail 35mm ( deep top hat style) Orientation horizontal or vertical Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings) All Channels Active 0.71 A Typical Power Dissipation (typical) 9W Wire Size - US / Metric 24 to 14 AWG / 0,205 - 2,08 mm sq. Fuse Ratings Module 2.0 A (Bussmann P/N: GMA-3.0A) (Siemens Spare P/N: A5E01574387) Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table Indicators Input Power Green LED on when input power available, Red LED on when power polarity is reversed Module Power Green LED on when module power available Channel Status Green LED on when channel is ON Field Connections Output Contacts Normally Open - NO Common - C Normally Closed - NC Wire Size - US / metric 24 to 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq.* Isolation 242 between channels < -- > shield + secondary Yes (250 VAC) between the channels yes. U< =150V reinforced insulation U > 150V to 250V basic insulation permissible voltage between groups of 8 channels 500 VAC (basic insulation) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Technical Specifications: 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES76501AM30-3XX0) Insulation test Test voltage (routine test at IEC 61131-2) Rated voltage 150V < Ue < 300V 1350 VAC/2sec (all channels to sec.+ shield) Rated voltage 100V < Ue < 150V (reinforced) 820 VAC/2sec (between channels for 150 VDC) Rated voltage 300V < Ue < 600V 2200 VAC/2sec (Group 0 < -- > Group 1) Relay Maximum Relay Contact Ratings Resistive Load: Max Switched Current: 5 Amps at 120 VAC - 230VAC 5 amps at 24 VDC 0.4 A at 150 VDC UL Contact Ratings: 5A/250 VAC General Purpose (Siemens Spare P/N A5E02164559) Switching Frequency Resistive load max. 0.1Hz Coil Resistance 1440 Ohms (Nominal) Minimum Output Rating (Wetting Rating) 100 mA at 12 VDC Relay Output Fuse None - External Fusing required Minimum operations Mechanical 30 million operations Electrical 2 x 10 at 10 A, 250 VAC, cos=0.6, 70C 5 Relay Contact Restrictions Relay Contact Fusing Fuses for the relay output connection must be provided externally to the MTA Relay Contact Protection To extend the life of the relay contacts protection components should be used. The protection components depend on the load voltage (ac or dc) and the load characteristics (high current, inductive, etc.) Relay Voltage Restrictions For voltages up to 150 VDC channels may be different voltages (one channel SELV and next max. 150 VDC). For voltages greater than 150 VDC, all channels must be of the same voltage. For AC voltages all channels must be the same phase for the channels in one group. There can be different phases between groups. 2 * Limiting the signal wiring to 14 AWG / 2.1 mm will make it easier to assemble and remove the MTA cover. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 243 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com Relays are available as spare parts from Siemens. Relay Information can be found at: http://www.azettler.com 18.8 Changes to 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) Specifications This section contains changes to the I/O module specifications when it is used with the MTA. Changes to 16-Channel, 24 VDC Discrete Output Module(6ES7 322-8BH01-0AB0) Specifications when used with 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA (6ES7650-1AM30-3XX0) 244 Reverse polarity power supply protection Yes Only outputs with series diodes are used. Therefore the behavior of the 6ES73228BH01 is according Manual for 6ES73228BH01 chapter 6.3.2 Tips and .../ Lamps / par 2) : -Diagnostic Message "M-short current" disabled in case of signal "0" - Diagnostic Message "P-short current" is changed to "broken wire Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.9 Technical Specifications for 16-Channel, 24 VDC Discrete Output Module (6ES7 322-8BH01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual SIMATIC ET 200M Signal Modules for Process Automation (document number A5E00085262-04). 18.10 Typical Load Connection to Field Terminals Figure 18-2 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA Load Connection to Field Terminals fuse NO0 NC0 120 - 230 Vac Supply 120 - 230 Vac Load COM0 Load powered when output energized NO1 fuse 120 - 230 Vac Supply NC1 120 - 230 Vac Load COM1 Load powered when output de-energized Note * Fuse is external to the MTA and not included. * Fuse should be sized appropriately for the load. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 245 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.11 Hardware Configuration The 16-Channel Discrete Output Module and its MTA support redundant and nonredundant operation. 18.11.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. Figure 18-3 shows a redundant configuration. Figure 18-3 16-Channel Discrete Output Hardware Configuration: Addresses set for Redundant Operation 246 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.11.2 Outputs The Relay Output MTA uses the series diode outputs from the DO16 module for both redundant and non-redundant operation. All options should be set to user preferences. Figure 18-4 shows the DO16 configured with all the diagnostics enabled. Figure 18-4 16-Channel Discrete Output Hardware Configuration: Outputs Configured for Standard Mode Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 247 16-Channel, 24-150 VDC/120-230 VAC Relay Output MTA 18.11.3 Redundancy Figure 18-5 shows a redundant 16-Channel Discrete Output configuration. Figure 18-5 16-Channel Discrete Output Hardware Configuration: Redundancy Selections 248 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 19 Power Monitor Board Part No. 6ES7650-1BA02-0XX0 19.1 Description This section contains information and requirements to facilitate installation of Siemens Power Monitor Board (6ES7650-1BA02-0XX0), designed to interface with the Siemens ET 200M MTAs. ! 19.2 Caution A previous version of the Power Monitor Board (6ES7650-1BA00) exists. The previous version is not suitable for use on MTAs with covers. Features The following features have been incorporated into this board: 19.3 * Dry contact output * Plug-in option Operation The Power Monitor Board (PMB) is used to provide an isolated dry contact for use when redundant power is supplied to the MTAs. If power is supplied to both power inputs and the power monitor board is installed, then the output contacts are closed and can be used to indicate this status. The PMB is designed to detect only the presence or absence of power. The PMB is not designed to detect supply voltage that is outside the specification threshold. The PMB is an optional accessory that plugs into the MTA and is secured via standoffs and screws. It contains 2 relays that are connected to the MTA power inputs. Power input A energizes one relay and Power input B energizes the second relay. The relay contacts are wired in series so that both power inputs must be valid before a complete contact closure is made. If one power supply is not functioning, then one relay de-energizes and one set of contacts open, breaking the circuit back to the sense system. Field Terminals, 1 and 2, are the output contacts for the external sensing system. See Section 2, Installation, before performing any installation and observe all warnings See Section 3, Maintenance, before performing any maintenance and observe all warnings Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 249 Power Monitor Board 19.4 Power Monitor Board Figure 19-1 Power Monitor Board 4 3 5 6 7 8 1 2 Key to numbered items in Figure 19-1: Item Description 250 1 Relays 2 Input Connector 3 Field Terminals 1 & 2 (Output Contacts) 4 Mounting Screw 5 Lock Washer 6 Flat Washer 7 Standoff 8 Retaining Washer Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Power Monitor Board 19.5 Technical Specifications Technical Specifications for Power Monitor Board (6ES7650-1BA02-0XX0) Dimensions L x W x D - inches 1.40 x .95 x 1.0 L x W x D - mm 35.6 x 24.1 x 25.4 Relay Output Contact Ratings Maximum Switched Voltage 30 VDC Maximum Switched Current 0.5 A Terminal Block Wire Size Wire Size - US 26 - 16 gauge AWG Wire Size - Metric 0,128 - 1,31 mm sq. Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption - All outputs ON 0.040 A maximum Relay Operations Electrical 100,000 minimum Mechanical 20,000,000 minimum Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 251 8-Channel HART Analog Input MTA 20 8-Channel HART Analog Input MTA Part No. 20.1 6ES7650-1AA61-2XX0 Description This section contains installation information and requirements for Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AA61-2XX0), which connects to the Siemens ET 200M 8-Channel HART Analog Input Module (6ES7 3317TF01-0AB0). 20.2 Features This MTA has the following features: * Redundant power connections * LED indication of redundant power supply condition * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel * Capable of mixing 2 and 4 wire transducers on a per channel basis * The 2 wire transducer power supply is current limited. (No fuse to replace after a short in the field) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 253 8-Channel HART Analog Input MTA 20.3 Operation Power is supplied via a removable power connector marked L+A, MA, L+B, and MB. There is circuitry to detect the presence of voltage over 15 VDC and turn on the LED indicator. The LEDs are marked A POWER and B POWER. There is also a connector for a Power Monitor board used to indicate the presence of both A and B power. See section 16 Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd to provide the MTA and the module power from either input source. The output from the ORing diode is sent to the I/O modules via the module fuses. Field Terminals, Channel + (Ix+), Channel - (Ix-), Sensor power (PWRx) and Shield (SHx), connect to the field devices. PWRx is the +24 VDC power source and is current limited to about 40- 60 mA on a channel-by-channel basis. The field termination connector is removable for ease of wiring maintenance and is retained by friction. The channel inputs from the MTA connect to the I/O modules inputs via D25 connectors (item 4 in figure 17.1). Redundant operation uses two modules, while non-redundant systems have one module connected to either I/O module connector. 254 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Input MTA 20.4 Installation Requirements See Section 2 Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD01-0AM0 or 6ES7922-3BJ010AM0), supporting eight analog input channels, connects the analog input termination assembly to the 8-channel analog input module (6ES7 331-7TF010AB0). Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumpers, Module 1 and Module 2, for the associated cable. 20.5 Maintenance See Section 3 Maintenance, before performing any maintenance and observe all warnings. Under normal operation, the A/B Power LEDs and Module 1/2 Fuse LEDs are green. If all are off, check the power supply to MTA. If Module 1/2 Fuse LED is off, check the module fuse and replace if necessary Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 255 8-Channel HART Analog Input MTA 20.6 8-Channel HART Analog Input Marshalled Termination Assembly The figure below shows the basic parts of the 8-Channel HART Analog Input MTA. Figure 20-1 8-Channel HART Analog Input Marshalled Termination Assembly (6ES7650-1AA61-2XX0) 9 5 8 CH7 + 4 CH6 + 4 CH5 + - CH4 CH7 4 CH4 + - 0.5A CH3 + - 4 2 CH4 CH2 CH5 2 CH2 + - 4 6 CH1 + - 4 CH2 CH3 4 CH0 + 2 2 CH0 12 CH2 SHIELD 11 CH2 I10 CH2 I+ 9 CH2 POWER 32 CH7 SHIELD 31 CH7 I30 CH7 I+ 29 CH7 POWER 24 CH5 SHIELD 23 CH5 I22 CH5 I+ 21 CH5 POWER 16 CH3 SHIELD 15 CH3 I14 CH3 I+ 13 CH3 POWER CH1 2 1 CH0 20 CH4 SHIELD 19 CH4 I18 CH4 I+ 17 CH4 POWER CH3 2 MODULE 2 MODULE 1 0.5A 28 CH6 SHIELD 27 CH6 I26 CH6 I+ 25 CH6 POWER CH5 2 7 CH7 2 CH6 CH6 2 MODULE 2 MODULE 1 MODULE 2 4 MODULE 1 4 CH1 4 CH0 SHIELD 3 CH0 I2 CH0 I+ 1 CH0 POWER 8 CH1 SHIELD 7 CH1 I6 CH1 I+ 5 CH1 POWER SHIELD 10 3 Key to numbered items in Figure 20-1 Item 1 2 3 4 5 6 7 8 9 10 256 Description Input power connections Input Power Indicators Field Connections I/O Module Connections Shield disconnect jumpers Module power fuses Module power indication HART Handheld connectivity Input Mode Jumper (2 or 4 wire transducers) Shield Ground Stud for connecting to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Input MTA 20.7 Technical Specifications Technical Specifications for 8-Channel HART Analog Input MTA (6ES7650-1AA61-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep or shallow; with panel mounted DIN rail only deep) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all inputs 2-wire transducers at 20mA, redundant modules) 0.29 A maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Electrical Isolation Between the channels and shield Yes Between the channels No Between the channels and load voltage L+ For 2-wire transducer: No 4-wire transducer: Yes Between the shield and load voltage L+ Yes Permissible potential difference Between the channels and shield (UISO) 75 VDC 60 VAC Between the channels and load voltage L+ For 4-wire transducer: 75 VDC 60 VAC Between the channels Permissible common-mode voltage with a 4wire transducer: 60 VAC Between the shield and load voltage L+ 75 VDC 60 VAC Insulation tested Channels to shield and load voltage L+ With 500 VDC, MTA jumper must be in 4 wire position Shield to load voltage L+ With 500 VDC Between the channels No Fuse Ratings / Current Limiting Module 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Channel (2 wire transducer connection) short circuit current about 40 - 60 mA Characteristic Data of Transducer Supply Output voltage for transducer and field wiring at 22 mA (125 sense resistor on modules already taken into account) 15 V (at Un = 24 V) Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 257 8-Channel HART Analog Input MTA Technical Specifications for 8-Channel HART Analog Input MTA (6ES7650-1AA61-2XX0) Indicators Input Power Green LED on when input power available, red LED on if power supply is reversed Module Fuse OK Green LED on when module power available Field Terminals Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table (in User's Manual) Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com 258 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Input MTA 20.8 Changes to Module Specifications Changes to 8-Channel HART Analog Input Module (6ES7 322-7TF01-0AB0) Specifications when used with 8-Channel HART Analog Input MTA (6ES7 650-1AA61-2XX0) Redundant Mode When using the MTA, the I/O module must be used in the redundant mode. For more information see Section 2.4 Connecting sensors/actuators in redundant mode in the HART analog modules manual, 08/2007, A5E00434623-03. 20 mA input range The 20 mA input range can not be used. Combining 2 wire and 4 wire transducers on one module. Any combination of 2 wire and 4 wire transducers is possible. The module inputs must be configured as 4 wire transducers regardless of transducer type. 20.9 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 259 8-Channel HART Analog Input MTA 20.10 Typical Wiring Schemes 2 Wire Transducer, Non Redundant Modules Application: The transducer is connected to either Module 1 or 2 via the HAI MTA. The jumper on the HAI MTA is placed in the 2 Wire position. 2 Wire Transducer, Redundant Modules Application: The transducer is connected to both Module 1 and 2 via the HAI MTA. The jumper on the HAI MTA is placed in the 2 Wire position. Figure 20-2 Two Wire Analog Input Current Input Connection. Only the basic HAI MTA circuitry is illustrated. MODULE 1 HAI MTA 2 WIRE TRANSDUCER + - MTA CABLE PWRx SM331; AI 8 x0/4...20 mA HART L+ M Ix+ IxSHx Mx+ Mx- CURRENT LIMITING CIRCUIT MODULE 2 FOR REDUNDANCY 4 WIRE 2 WIRE MA MB 24V SM331; AI 8 x0/4...20 mA HART L+ M 24V L+B L+A 260 MTA CABLE Mx+ Mx- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Input MTA 4 Wire Transducer, Non Redundant Modules Application: The transducer is connected to either Module 1 or 2 via the HAI MTA. The jumper on the HAI MTA is placed in the 4 Wire position. 4 Wire Transducer, Redundant Modules Application: The transducer is connected to both Module 1 and 2 via the HAI MTA. The jumper on the HAI MTA is placed in the 4 Wire position. Figure 20-3 Four Wire Analog Input Current Input Connection. Customer must provide power to the transducer. Only the basic HAI MTA circuitry is illustrated. MODULE 1 HAI MTA MTA CABLE PWRx 24V 4 WIRE TRANSDUCER + - SM331; AI 8 x0/4...20 mA HART L+ M Ix+ Ix- Mx+ SHx Mx- CURRENT LIMITING CIRCUIT MODULE 2 FOR REDUNDANCY 4 WIRE 2 WIRE MA MB 24V MTA CABLE SM331; AI 8 x0/4...20 mA HART L+ M 24V L+B L+A Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Mx+ Mx- 261 8-Channel HART Analog Input MTA 20.11 Hardware Configuration Use the 2 - 4 jumpers to select either 2 or 4 wire transducer. See Figure 20-1 Item 5, for the location of the shield isolation jumpers and Item 9, for the location of the 2 - 4 jumpers. 20.11.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. 20.11.2 Inputs The inputs must be configured as 4 wire transducers. 20.11.3 Redundancy For non-redundant operation the value of the Redundancy field should be None. 20.12 Technical Specifications for 8-Channel HART Analog Input Module (6ES7 331-7TF01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual ET 200M distributed I/O device HART analog modules (document number A5E00434623). 262 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Output MTA 21 8-Channel HART Analog Output MTA Part No. 6ES7650-1AB61-2XX0 21.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1AB61-2XX0), designed to interface with the Siemens ET 200M 8-Channel HART Analog Output Module (6ES7 332-8TF01-0AB0). 21.2 Features The following features have been incorporated into this MTA: * Redundant power connections * LED indication for each power supply * Power monitor plug-in available (optional) * Dual connectors for redundant I/O Module operation * Per module power fusing * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground * Power input and field terminations are pluggable for easy maintenance * Connectivity for HART Handheld Terminal (HHT) per channel Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 263 8-Channel HART Analog Output MTA 21.3 Operation Power is supplied via the two removable power connectors which are retained by screws and marked L+A, MA, and L+B, MB. Each has circuitry to detect the presence of voltage over 15VDC and turn on the LED indicator. The LEDs are marked A POWER and B POWER. There is also a connector for a Power Monitor board used to indicate the presence of both A and B power. See section 16 Power Monitor Board (6ES7650-1BA02-0XX0). Incoming power from A and B is diode OR'd to provide the MTA and the module power from either input source. The output from the ORing diode is sent to the I/O modules via the module fuses. Field Terminals, Channel + (CHx+), Channel - (CHx-), and Shield (SHx), connect to the field devices. CHx+ is the current output source and CHx- is the current output sink. The I/O module outputs are diode OR'd, on the I/O module, before connecting to CHx+ of the Field terminals. Redundant operation uses two modules, while non-redundant systems have one module connected to either I/O module connector The field termination connectors are removable for ease of wiring maintenance and are retained by friction. 21.4 Installation Requirements See Section 2 Installation, before performing any installation and observe all warnings A common interconnecting cable (6ES7922-3BD01-0AM0 or 6ES7922-3BJ010AM0), supporting eight analog input channels, connects the analog input termination assembly to the 8-channel analog input module (6ES7 331-7TF010AB0). See Figure 4-1. It may be necessary to modify the cable shield connections on the printed circuit board. Note To disconnect the interconnecting cable shield from ground at the MTA only, cut and remove the shield disconnect jumpers, Module 1 and Module 2, for the associated cable. 21.5 Maintenance See Section 3 Maintenance, before performing any maintenance and observe all warnings. Under normal operation, the A/B Power LEDs and Module 1/2 Fuse LEDs are green. If all are off, check the power supply to MTA. If Module 1/2 Fuse LED is off, check the module fuse and replace if necessary 264 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Output MTA 21.6 8-Channel HART Analog Output Marshalled Termination Assembly Figure 21-1 below shows the basic parts of the 8-Channel HART Analog Output MTA. Figure 21-1 8-Channel HART Analog Output Marshalled Termination Assembly (6ES7650-1AB61-2XX0) 5 CH4+CH4- SH4 CH5+CH5- SH5 CH6+CH6- SH6 CH7+CH7- SH7 CH0+CH0- SH0 CH1+CH1- SH1 CH2+CH2- SH2 CH3+CH3- SH3 CH7 - + CH5 CH4 CH1 CH0 + + + 6ES7 650-1AB61-2XX0 M A M B HART Analog Output CH6 + + + MODULE 2 L+ B 9 MODULE 1 L+ A 1 A POWER B POWER 2 + 7 CH3 8 CH2 MODULE 2 MODULE 2 MODULE 1 MODULE 1 4 24 CH7 SHIELD 23 CH722 CH7+ 21 CH6 SHIELD 20 CH619 CH6+ 18 CH5 SHIELD 17 CH516 CH5+ 15 CH4 SHIELD 14 CH413 CH4+ 12 CH3 SHIELD 11 CH310 CH3+ 9 CH2 SHIELD 8 CH27 CH2+ 6 CH1 SHIELD 5 CH14 CH1+ 3 CH0 SHIELD 2 CH01 CH0+ SHIELD 6 3 Key to numbered items in Figure 21-1: Item Description 1 2 3 4 5 6 7 8 9 Input power connections Input power indicators Field wiring connections I/O module connections (Module 1 & 2) Shield disconnect jumper (Module 1 & 2) Module power fuses Module power indicators HART Handheld connectivity ( 1 of 16 ) Ground stud for connecting shield to earth ground Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 265 8-Channel HART Analog Output MTA 21.7 Technical Specifications Technical Specifications for 8-Channel HART Analog Output MTA (6ES7650-1AB61-2XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm ( deep or shallow; with panel mounted DIN rail only deep) Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Current Consumption (nominal ratings; all channels connected, redundant modules) All output channels at 20mA 0.50 A Maximum Power Dissipation (typical) 1W Terminal Block Wire Sizes Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Electrical Isolation Between the channels and shield Yes Between the channels No Between the channels and load voltage L+ Yes Between the shield and load voltage L+ Yes Permissible potential difference Between the channels and shield (UISO) 75 VDC 60 VAC Between the channels and load voltage L+ 75 VDC 60 VAC Between the shield and load voltage L+ 75 VDC 60 VAC Insulation tested Channels to shield and load voltage L+ With 500 VDC Shield to load voltage L+ With 500 VDC Between the channels No Fuse Ratings / Current Limiting Module 0.5 A (Bussmann P/N: GMA-0.5A) (Siemens Spare P/N: A5E01568885) Indicators 266 Input Power Green LED on when input power available, red LED on if power supply is reversed Module Fuse OK Green LED on when module power available Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Output MTA Field Terminals Wire Size - US 24 - 14 AWG Wire Size - Metric 0,205 - 2,08 mm sq. Environmental Ambient Temperature -25C to +60C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals See Preface section, Approvals Table (in User's Manual) Note Fuses are available as spare parts from Siemens. Fuse information can be found at: http://www.bussmann.com 21.8 Module Restrictions Changes to 8-Channel HART Analog Output Module (6ES7 322-8TF01-0AB0) Specifications when used with 8-Channel HART Analog Output MTA (6ES7 650-1AB61-2XX0) None Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 267 8-Channel HART Analog Output MTA 21.9 Typical Wiring Schemes Non-Redundant Module Application: The load or actuator is connected to either Module 1 or 2 via the AOH MTA. Redundant Modules Application: The load or actuator is connected to both Module 1 and Module 2 via the AOH MTA. Figure 21-2 Typical wiring scheme for connecting load field terminals. Only the basic AOH MTA circuitry is illustrated. MODULE 1 HAO MTA MTA CABLE SM 322; AO 8 X 0/4...20mA HART L+ M 4-20 mA LOAD CHx+ CHx+ CHx- CHx- SHx- MODULE 2 (FOR REDUNDANCY) MA MB 24V SM 322; AO 8 X 0/4...20mA HART L+ M 24V L+B L+A 268 MTA CABLE CHx+ CHx- Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 8-Channel HART Analog Output MTA 21.10 Hardware Configuration The HART Analog Output MTA has no jumpers that affect the Module Hardware Configuration. Note Redundant Operation. If a redundant HART Analog Output Module loses power (module fuse opens) or is removed from service, then the output current will drop to 50% of its value for several controller cycles. 21.10.1 Addresses Non-redundant Operation The choice of the Input Address and Process Image are left to the user. Redundant Operation Process Image should be set to something other than the default. The choice of the Input Address is left to the user. 21.10.2 Outputs For normal operation set Type of Output to current (I). The +/- 20 mA output range is not possible due to the MTA Design. All other Module hardware configuration choices under the Outputs tab are left to the user. 21.10.3 Redundancy For non-redundant operation the value of the Redundancy field should be None. 21.11 Technical Specifications for 8-Channel HART Analog Output Module (6ES7 332-8TF01-0AB0) Note For a complete functional description and the most current technical specifications for this module, refer to the manual ET 200M distributed I/O device HART analog modules (document number A5E00434623). Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 269 8-Channel HART Analog Output MTA 270 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Power Supply MTA 22 16-Channel, 24 VDC Power Supply MTA Part No. 6ES7650-1BE10-3XX0 22.1 Description This section contains information and requirements to facilitate installation of Siemens Marshalled Termination Assembly (MTA) (6ES7650-1BE10-3XX0), designed to energize 4-wire transducers 22.2 Features The following features have been incorporated into this MTA: 22.3 * Redundant power connections * LED indication of redundant power supply operation * LED indication of reverse polarity * Power monitor output * Short circuit detection on the outputs * 16 outputs rated at 24V/ 0.5A * each output electronically short circuit protected * one LED per output * Shield connections available for channel cabling * Ground stud for connecting shield to earth ground Operation The modules 8-Channel Analog Input MTA (6ES7 650-1AA52-2XX0) 6-Channel F Analog Input HART MTA (6ES7 650-1AA62-5XX0) 8-Channel Analog Input HART MTA (6ES7 650-1AA61-2XX0) provide a supply only for 2-wire- and not for 4-wire transducer. This gap will be filled by the 16-Channel Power Supply MTA. The MTA provides 16 outputs rated at 24V/0.5A. In case 0.5A is not sufficient for energizing the transducer, two or more outputs of the same MTA can be connected in parallel. The outputs are individually short circuit protected without using destructible fuses. In case one or more outputs are short circuited, there is no influence on the remaining outputs. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 271 16-Channel, 24 VDC Power Supply MTA Power is supplied via the power connector marked L+A, MA, and L+B, MB. Each has a green LED to indicate the presence of voltage over 15 VDC. In the case of polarity reversal of the power supply, the LEDs will illuminate red. The LEDs are marked A POWER and B POWER. Incoming power from A and B is diode OR'd to provide the MTA from either power source. The output from the dual diode is used to supply the 16 outputs of the MTA. One green LED per output signals the power availability for this channel. An onboard Power Monitor System (PMS) is used to provide an isolated dry contact when redundant power is supplied to MTAs. Only when power is supplied to both power inputs the output contacts 1 and 2 are closed. The Power Monitor System is designed to detect only the presence or absence of power. It is not designed to detect supply voltage which is outside the specification threshold. An onboard Short Circuit Detection (SCD) is used to provide an isolated dry contact in case one or more outputs will be short circuited. For a few seconds after applying or removing the short circuit, the dry contact may toggle before providing a stable ON or OFF status. Field Terminals, Power+ (PWR+), Ground (Mx), and Shield (SHx), connect to the field devices. PWRx provides the transducer supply current. Mx is the transducer power return. ! 22.4 Caution The heat sink can be over 100 C. Avoid contact during servicing. Installation Requirements See Section 2, Installation, before performing any installation and observe all warnings 22.5 Maintenance See Section 3, Maintenance, before performing any maintenance and observe all warnings Under normal operation, the A/B Power LEDs are illuminated green. If an A/B Power LED is illuminated red (or off), check the power supply to the MTA. Under normal operation the 16 LEDs on the outputs are illuminated green. If one or more LEDs are off, check the cabling or load for a short circuit. 272 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Power Supply MTA 22.6 Simplified diagram Figure 226-1 16-Channel, 24VDC Power Supply Marshalled Termination Assembly (6ES7650-1BE103XX0) L/A+ L/B+ M/A M/B 1 & PMS 2 1 SCD 2 PWRx + 4-wire transducer - - Field wiring connections Mx + MTA - PS Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 273 16-Channel, 24 VDC Power Supply MTA 22.7 Component Identification Figure 226-2 16-Channel, 24 VDC Power Supply Marshalled Termination Assembly (6ES7650-1BE103XX0) 5 4 3 1 6 2 7 8 Key to numbered items in Figure 15-1: Item Description 274 1 Input power connections (Power A, Power B) 2 Input power indicators (Power A, Power B) 3 Output Power Monitor System 4 Output Short Circuit Detection 5 Heat sink 6 Ground stud for connecting shield to earth ground 7 Output status indicators (1 ... 16) 8 Field wiring connections Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Power Supply MTA 22.8 Technical Specifications Technical Specifications: 16-Channel, 24 VDC Power Supply MTA (6ES7650-1BE10-3XX0) Dimensions - See Section 1, Figure 1.3, Short Version Mounting DIN Rail 35mm (deep top hat style) Orientation horizontal or vertical Power Input Voltage Input for Single or Redundant Feed 21.6 to 28.8 VDC Total current o 8.1 A maximum o to 60 C 5.1 A maximum without load 0.1 A maximum to 40 C Power Dissipation (typical) 5W Power Output per channel Output voltage min L+ - 1.2V Output current 0.5A Short circuit protection yes, electronic * Threshold ca. 1A Wiring two or more outputs of the same MTA in parallel for increased performance supported Wiring two or more outputs of different MTAs in parallel for increased performance not supported Power Output per module Output current o Total 8A max at Ta = 40 C o Total 5A max at Ta = 60 C Power Monitoring System - Output Contact Ratings Threshold voltage ca. 15 V Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit protected Short Circuit Detection - Output Contact Ratings Maximum switched Voltage 30 V DC Maximum switched Current 0.5 A resistive load; not short circuit protected Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 275 16-Channel, 24 VDC Power Supply MTA Indicators Input Power Green LED on when input power available, Red LED on when power polarity is reversed Power Output Status Green LED Field Connections Wire Size US Wire Size metric 24 to 14 AWG 2 0.2 to 2.08 mm Environmental o o Ambient Temperature -25 C to +60 C Humidity 5% to 95% Non-condensing Approvals MTA Agency Approvals 276 See Preface section, Approvals Table Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 16-Channel, 24 VDC Power Supply MTA 22.9 Typical Load Connection to Field Terminals PWR0 PWR1 M0 M1 SH0 SH1 PWR2 Figure 226-3 Load Connection to Field Terminals of 16-Channel, 24 VDC Power Supply MTA MTA-PS + Sensor + Input - MTA-AI8 MTA-FAIH Supply + Output Current - Ix+ Ix- 4-wire Transducer 22.10 AI module 1 AI module 2 Hardware Configuration In PCS7 no HW Configuration will be necessary Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 277 Previous MTA Revisions 23 Previous MTA Revisions This section contains information about previous revisions of the ET200M MTAs. 23.1 Part No. 8 Channel Analog Input MTA 6ES7650-1AA50-2XX0 8-Channel Analog Input Marshalled Termination Assembly Figure 23-1 8-Channel Analog Input Marshalled Termination Assembly (6ES7650-1AA50-2XX0) 1 2 4 5 B POWER 2 18 J1 ZR101 34 3 19 35 4 5 20 36 21 6 22 38 37 8 7 23 39 24 40 9 25 41 10 26 42 11 27 43 12 28 44 13 29 45 14 30 46 15 31 47 16 17 33 32 48 49 C101 1 CR105 50 CR104 SHIELD A POWER W100 ZR100 R101 W101 R100 1 2 4 3 5 8 7 6 9 10 11 13 12 14 15 16 17 INPUT CONNECTION CHART V I NON- NON- ISOLATED ISOLATED 35 36 38 37 23 39 24 25 41 40 26 42 27 43 28 44 29 45 30 46 31 48 47 33 32 50 49 NC POSITIVE W200 8 I Analog Input ISOLATED CUT FOR ISOLATION ISOLATED = CUT W200 0.5A 0.5A R9 HART+ W4 FUSE I FUSE I 0.5A 0.5A HART+ V W6 FUSE I CH7 FUSE I F6 0.5A V W7 CH6 F5 F4 CH7 HART+ V W5 CH5 CH4 F3 F2 R2 R1 0.5A FUSE I R11 F1 F0 HART+ CH6 R14 FUSE I HART- V W3 CH3 CH2 CH5 I 0.5A 0.5A 7 6 CR106 3 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 10 F7 R7 FUSE I HART+ V W2 CH4 R13 HART+ V W1 CH1 COM R6 V W0 CH0 CH3 R12 HART+ HART+ FUSE CH2 R5 CH1 CH0 R4 x = CHANNEL # 34 J3 EXT PWR 22 NEGATIVE R10 ISOLATED ISOLATED POSITIVE POWER - NONW200 POWER + NEGATIVE & I 21 R16 NEGATIVE NEGATIVE 20 R15 POSITIVE POSITIVE Ix- R3 12 4 WIRE INT PWR NC Ix+ 19 R8 2 WIRE INPUT PWRx W0-W7 18 J2 C100 CURRENT INPUT VOLTAGE 9 11 279 Previous MTA Revisions Key to numbered items in Figure 23-1: Item 1 2 3 4 5 6 7 8 9 10 11 12 280 Description Input power connections Input Power Indicators Field Connections I/O Module Connections ( J1 & J2 ) Shield disconnect jumper (W100 & W101) Field power fuses Field power indication ( 1 of 8 ) Input Isolation Jumper ( W200) HART connectivity Input Mode Jumper ( I - V ) 250 resistors ( R1-R8 ) Input Connection Chart Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Safety Information for US Customers 24 Safety Information for US Customers Conventions and Symbols Symbol The following symbols may appear in this manual and may be applied to the equipment. The reader should become familiar with the symbols and their meaning. Symbols are provided to quickly alert the user to safety related situations, issues, and text. Meaning DANGER Indicates an immediate hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION NOTICE Important Note Indicates a potentially hazardous situation which, if not avoided, may result in property damage. Indicates a potential situation which, if not avoided, may result in an undesirable result or state. Identifies an action that should be taken to avoid an undesirable result or state. Identifies additional information that should be read. Electrical shock hazard. The included Warning text states that the danger of electrical shock is present. Electrical shock hazard. Indicated that the danger of electrical shock is present. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-09 281 Safety Information for US Customers Symbol Meaning Explosion hazard. Indicates that the danger of an explosion hazard exists. Electrostatic discharge. The presence of this symbol indicates that electrostatic discharge can damage the electronic assembly. Hot Surface. Indicates the danger of getting burned is present. Qualified Persons The described equipment should be installed, configured, operated, and serviced only by qualified persons thoroughly familiar with this publication. The current version, in Portable Document Format (PDF), is available at http://sitescape.sea.siemens.com/. For the purpose of this publication and product labels, a qualified person is one who is familiar with the installation, construction, and operation of the equipment, and the involved hazards. In addition, he or she has the following qualifications: 282 * Is trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established safety practices. * Is trained in the proper care and use of protective equipment such as rubber gloves, hard hat, safety glasses or face shields, flash clothing, etc., in accordance with established safety practices. * Is trained in rendering first aid. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 Safety Information for US Customers General Warnings and Cautions WARNING This equipment contains hazardous voltages, and it has been certified for use in the hazardous locations specified on the product nameplate and in the Model Designation and Specifications section. Death, serious personal injury, or property damage can result if safety instructions are not followed. Only qualified personnel should work on or around this equipment after becoming thoroughly familiar with all warning, safety Notes, and maintenance procedures contained herein. The successful and safe operation of this equipment is dependent upon proper handling, installation, operation, and maintenance. The perfect and safe operation of the equipment is conditional upon proper transport, proper storage, installation and assembly, as well as, on careful operation and commissioning. The equipment may be used only for the purposes specified in this publication. CAUTION Electrostatic discharge can damage or cause the failure of semiconductor devices such as integrated circuits and transistors. The symbol at right may appear on a circuit board or other electronic assembly to indicate that special handling precautions are needed. * A properly grounded conductive wrist strap must be worn whenever an electronics module or circuit board is handled or touched. A service kit with a wrist strap and static dissipative mat is available from Siemens (PN15545110). Equivalent kits are available from both mail order and local electronic supply companies. * Electronic assemblies must be stored in anti-static protective bags when not installed in equipment. Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12 283 Safety Information for US Customers 284 Marshalled Termination Assemblies for ET200M Remote I/O Modules A5E00482820-12