D1U-W-1200-12-HC Series
AC/DC Front End Power Supply
D1U-1200-12-HC.1 Page 1 of 4
www.cd4power.com
FEATURES
n1200W (220Vac), 900W (110Vac)
Output power
n12V Main output,
3.3V or 5V standby output
n1U sized; dimensions 12” x 4.75” x 1.6”
n13.2 Watts per cubic inch density
nN+1 redundancy capable,
including hot-docking
nActive current sharing on main output
nOver-voltage, over-current,
over-temperature protection
nInternal cooling fans
nI²C Bus Interface with status indicators
nOptional 1U x 19” power-shelf
DESCRIPTION
The D1U-W-1200 is a 1200 Watt, power-
factor-corrected (PFC) front-end power supply
for hot-swapping redundant systems. The
main output is 12V and standby output of
either 5V or 3.3V. Packaged in 1U low profile,
it is designed to deliver reliable bulk power to
servers, workstations, storage systems or any
12V distributed power architecture systems
requiring high power density. The highly efficient
electrical and thermal design with internal cooling
fans supports reliable operation conditions. The
D1U-W-1200 is designed to auto-recover from
over-current and over-temperature faults. Status
information is provided with front panel LEDs,
logic signals and I2C management interface. Three
units can be packaged into an optional 19” 1U
power shelf to provide up to 3.6kW of power.
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage Parameter Conditions MIN. TYP. MAX. Units
12V
Voltage Set Point Accuracy 12.12 Vdc
Line and Load Regulation 11.75 12.48
Ripple Voltage & Noise 20MHz Bandwidth 120 mV p-p
Output Current 0 98.3 A
3.3Vsb
Voltage Set Point Accuracy 3.3 Vdc
Line and Load Regulation 3.2 3.4
Ripple Voltage & Noise 33 mV p-p
Operating Range 0 6 A
5Vsb
Voltage Set Point Accuracy 5 Vdc
Line and Load Regulation 4.85 5.15
Ripple Voltage & Noise 50 mV p-p
Operating Range 0 4 A
SELECTION GUIDE
Model Number Power Output
High Line AC
Power Output
Low Line AC Main Output Standby
Output Airflow
D1U-W-1200-12-HC2 1200W 900W 12V 3.3V Back to front
D1U-W-1200-12-HA2 1200W 900W 12V 5V Back to front
OUTPUT CHARACTERISTICS
Parameter Conditions MIN. TYP. MAX. Units
Remote Sense 120 mV
Efficiency 220Vac 90.6 %
Start-up Time AC ramp up 1.5 s
PS_On activated 150 ms
Transient Response 12V Ramp 1A/ms ±600
mV3.3Vsb Ramp 1A/ms ±165
5Vsb Ramp 1A/ms ±250
Current sharing accuracy (up to 3 in
parallel) At 100% load ±10 %
Hold-up Time 20 ms
INPUT CHARACTERISTICS
Parameter Conditions MIN. TYP. MAX. Units
Input Voltage Operating Range 90 264 Vac
Input Frequency 47 55 63 Hz
Turn-on Input Voltage Ramp up 78.5 86.5 Vac
Turn-off Input Voltage Ramp down 70.5 78
Maximum Input Current 12 Arms
Inrush Current 90 Apk