TXD2000 2/2000 REV APage 2
Input Specifications
Parameters Conditions Min Typ Max Units
Operating Range
1000W 47-63Hz 90 264 VAC
2000W 47-63Hz 180 264 VAC
Inrush Current 120VAC, 250C, cold start 80 Apk
240VAC, 250C, cold start 160 Apk
Efficiency Nominal line, full load 70 75 80 %
Holdup Full load 20 msec
Power Factor (1) Full load 0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltage Modules and Maximum Rated Load
Output Output Voltage Output Current Output Power
Voltage Code Voltage (Maximum Continuous) (Maximum Continuous)
A 5.0 200A 1000W
B 12.0 83A 1000W
C 15.0 67A 1000W
D 18.0 55A 1000W
E 24.0 42A 1000W
F 28.0 36A 1000W
G 36.0 28A 1000W
H 48.0 21A 1000W
J 20.0 40A 800W
K 3.3 182A 600W
L 2.5 200A 500W
Output Specifications
Parameter Conditions Min Typ Max Units
Output Power All environmental and line conditions
90-264VAC 1000 Watts
180-264VAC Limited by output module selection 2000 Watts
Voltage Adjustment Range Relative to nominal output voltage +5 %
Output Regulation Line, load or cross +0.2 %
Minimum Load 0 Amps
PARD Measured at output terminals, 20MHz 50 mv or 1% pk-pk
Temperature Coefficient 00 to 500C+0.2 %/0C
Environmental Specifications
Parameter Conditions Min Typ Max Units
Ambient Temperature Output de-rated linearly to 50% of
(Operating) rated capacity between 500C and 700C 0 +70 0C
Ambient Temperature Non-operating -50 +85 0C
Altitude (Operating) -200 +10,000 Feet
Altitude (Non-operating) -200 +50,000 Feet
Shock Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Vibration Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
Cooling The TXD2000 is provided with internal cooling fans.