INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R01
CPC1966YX6
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage (VDRM) 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
di/dt Critical Rate of Rise
of On-State Current 75 A/s
Input Power Dissipation 1150 mW
Total Power Dissipation 22400 mW
ESD, Human Body Model 4 kV
i2t Fusing Current (1/2 Sine Wave, 60Hz) 8 A2s
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 20 mW / ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current, Continuous VL=20-240Vrms IL0.1 - 3 Arms
Maximum Surge Current t < 16ms IP--30 A
Off State Leakage Current VDRM I
LEAK - - 100 AP
On-State Voltage Drop IL=2AP- - 0.88 1.1 VP
Off-State dV/dt - dV/dt 1000 - - V/s
Switching Speeds
Turn-on IF = 5 mA, Resistive,
VL=20V, 60Hz
ton - 20 500 s
Turn-off toff - - 0.5 cycles
Holding Current - IH-4450 mA
Latching Current - IL-4875 mA
Operating Frequency - 20 - 500 Hz
Input Characteristics
Input Control Current to Activate 160Hz IF--5 mA
Input Drop-out Voltage - - 0.8 - - V
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Input to Output Capacitance - CI/O --3 pF
1 For high-noise environments, or for high-frequency operation, use IF > 10mA.