2 Uninterruptible Power Systems S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS The new SolaHD S4K4U6000C and the S4K6U10KC Industrial UPS Series are the first true On-Line industrial UPS that provide higher output power factor, higher efficiency, flexible output voltage, an integrated maintenance bypass switch and internal batteries all in slim 4U (7.0") and 6U (10.5") enclosures respectively. The S4K4UC and S4K6UC features true On-Line (double conversion) topology providing the ultimate in protection against a wide range of potential power problems. The S4K4UC design of two 3 kVA, 120V inverters allow flexible output voltage to meet mixed load voltage requirements. The UPS automatically configures the output voltage to match the input configuration without requiring tap selections. Self diagnostics simplify maintenance and troubleshooting. The standard maintenance bypass switch provides an additional level of protection. The S4K4UC and S4K6UC also feature a wide input voltage window to support the critical load without having to transfer to the battery. This extends system availability when back-up is truly needed. Applications * Industrial Computers * Robotics and Process Controls * * * * * * * * Industrial Automation Systems Network Servers Enterprise Telecommunication Systems Printing and Publishing Machinery Pharmaceutical and Medical Diagnosis Equipment Industrial and Commercial Machinery Micro-processor Controlled Equipment Mission Critical Devices Features * True double conversion topology * Higher power factor of 0.80 (6kVA) and 0.90 (10kVA) * Both models offer 208/120V or 240/120V * Configurable as a tower or rack mounting * Highest density, 6 kVA in only 4U and 10 kVA in only 6U of rack space * Easily installed in 18" to 32" deep rack using rack mount kit # SRS1832 * User replaceable, hot-swappable internal battery module 78 E179213 * Extended battery cabinets * Includes both automatic and manual maintenance bypass switch * Automatic frequency detection (60 or 50 Hz) * Power factor correction * Self-diagnostics simplify maintenance and troubleshooting * Remote emergency Power Off (REPO) * IntellislotTM USB and terminal block communication ports * Compatible with most standby generators * Two year limited warranty Certifications and Compliances * Listed, UPS Equipment - UL 1778 - CSA C22.2 No. 107.3 * IEEE/ANSI C62.41 Category A & B * ISTA Procedure 1A Related Products * Portable MCR Power Conditioners * Surge Protective Devices * Active Tracking(R) Filters Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 2 Uninterruptible Power Systems S4K 6 and 10 kVA Specifications Table 1: UPS Specifications Parameters Rating Model Number S4K4U6000C S4K6U10KC 4800 W/6000 VA 9000 W/10000 VA Dimensions, W x D x h, in. (mm) Unit 6.80 x 26.10 x 16.90 (173.0 x 662.0 x 430.0) 10.30 x 26.50 x 16.90 (261.0 x 672.0 x 430.0) Shipping 13.20 x 33.10 x 26.10 (336.0 x 842.0 x 662.0) 16.70 x 32.80 x 24.10 (424.0 x 832.0 x 612.0) weight, lbs. (kg) Unit 56.2 (25.50) 78.3 (35.50) Shipping 70.5 (32.00) 92.6 (42.00) Input AC Parameters Nominal Operating Frequency 50 or 60 Hz (Factory default is 60 Hz) 120/208 Vac @ 120C Factory Default Vac 120C L1-L2 Factory Default Input Phase Angle Allowable Input Phase Angle 120, 180, 240 degrees; auto-sensing on application of alternating current (Restrictions for L-N voltage other than 120 Vac) 120 Vac nominal Factory Default L1-N, L2-N Vac User Configurable L1-N, L2-N Vac 100/110/115/120/127 Vac (Can be modified with configuration program) 40-70 Hz Input Frequency w/o Battery Operation Input Power Connection Hardwire terminal block 3W + G (L-L-N-G) 150 Vac L1-N, L2-N Maximum Allowable Vac Output AC Parameters Factory Default Vac L1-L2 Factory Default Output Phase Angle 120/208 Vac @ 120C 120C Allowable Output Phase Angle 120, 180, 240 degrees; auto-sensing on initial application of input alternating current Factory Default L1-N, L2-N Vac 120 Vac nominal User Configurable L1-N, L2-N Vac 100/110/115/120/127 Vac, 2% L1-N, L2-N Overload Rating 105% to 130% 1 minute 131% to 150% 10 seconds 151% to 200% 1 second >200% (impact load) At least 5 cycles Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 79 2 Uninterruptible Power Systems S4K 6 and 10 kVA Specifications - continued Table 2: UPS Specifications Model Number Parameters S4K4U6000C S4K6U10KC Bypass Protection Limits If input voltage exceeds 15% of the nominal voltage Disable Bypass Operation If input voltage returns to within 10% of nominal output voltage Re-enable Bypass Operation When the input frequency prevents synchronous operation Disable Bypass Operation Environmental Requirements 0C to +40C; see Table 11 for operating temperature parameters Operating Temperature -15C to +50C Storage Temperature 0% to 95%, non-condensing Relative Humidity Up to 10,000 ft. [3,000 m] Operating Elevation <55 dBA @ 3.2 ft. [1 m] rear; <50 dBA @ 3.2 ft. [1 m] front & sides Audible Noise Standards FCC Part 15, Subpart B, Class A, FCC Class A EMC Table 3: Operating Temperature Parameters Ambient Temperature 80 Model Number S4K4U6000C S4K6U10KC pf @ 30C 3C 0.8 pf 0.9 pf pf @ 40C 3C 0.8 pf 0.8 pf Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 2 Uninterruptible Power Systems Table 4: Internal Battery Specifications Parameters Used with UPS Models Model Number S4K144INTBATC S4K288INTBATC S4K4U6000C S4K6U10KC Dimensions, W x D x h, in. (mm) Unit Shipping 2.80 x 19.30 x 8.10 (70.0 x 490.0 x 206.0) 5.30 x 19.70 x 8.10 (135.0 x 500.0 x 207.0) 12.20 x 23.70 x 10.30 (310.0 x 602.0 x 262.0) 12.20 x 23.90 x 9.50 (310.0 x 607.0 x 242.0) Weight, lbs. (kg) Unit 75.8 (34.40) 71.1 (32.30) Shipping 81.1 (36.80) 76.4 (34.70) Battery Parameters Type Qty x V x Rating Valve-regulated, non-spillable, flame retardant, lead acid 2 x 6 x 12 V x 8.5 Ah 2 x 12 x 12 V x 8.5 Ah CSB type HR1234WF2 Battery Mfr./Part Number See Table 8 Backup Time Recharge Time 3 hours to 90% capacity after full discharge into 100% load Environmental Requirements Operating Temperature Storage Temperature Relative Humidity Operating Elevation 0C to +40C -15C to +50C 0% to 95%, non-condensing Up to 10,000 ft. [3,000 m] at +40C without derating Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 81 2 Table 5: Uninterruptible Power Systems External Battery Cabinet Specifications Parameters Used with UPS Models Model Number S4K144BATC S4K288BATC S4K4U6000C S4K6U10KC Dimensions, W x D x h, in. (mm) Unit (with bezel) Shipping 3.30 x 26.10 x 16.90 (85.0 x 662.0 x 430.0) 6.80 x 26.50 x 16.90 (173.0 x 672.0 x 430.0) 25.80 x 34.30 x 12.30 (655.0 x 872.0 x 312.0) 13.20 x 33.10 x 24.50 (336.0 x 842.0 x 622.0) Weight, lbs. (kg) Unit 99.9 (45.30) 29.8 (13.50) Shipping 110.2 (50.00) 44.1 (20.00) Battery Parameters Type Qty x V x Rating Valve-regulated, non-spillable, flame retardant, lead acid 2 x 6 x 12 V x 8.5 Ah 2 x 12 x 12 V x 8.5 Ah CSB type 1234WF2 Battery Mfr./Part Number See Table 8 Backup Time Environmental Requirements Operating Temperature Storage Temperature Relative Humidity Operating Elevation 82 0C to +40C -15C to +50C 0% to 95%, non-condensing Up to 10,000 ft. [3,000 m] at +40C without derating Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 2 Uninterruptible Power Systems Table 6: Power Distribution Specifications for S4K4U6000C Model Number Parameters S4KPAD2HDWRC S4KPAD2HDWR-MBSC * S4KPAD2001C S4KPAD2002C S4KPAD2003C S4KPAD2004C S4KPAD2005C S4KPAD2006C S4KPAD2L630C Dimensions, W x D x h, in. (mm) Unit 5.20 x 15.50 x 3.50 (132.0 x 393.0 x 88.0) 4.70 x 13.20 x 4.10 (119.0 x 335.0 x 105.0) Shipping 9.50 x 20.70 x 9.10 (242.0 x 527.0 x 230.0) 10.20 x 18.40 x 8.70 (119.0 x 335.0 x 105.0) Weight, lbs. (kg) Unit 5.1 (2.30) 6.0 (2.70) 8.8 (4.00) 8.6 (3.90) 8.6 (3.90) 9.9 (4.50) 10.6 (4.80) 9.5 (4.30) 8.8 (4.00) Shipping 7.3 (3.30) 8.2 (3.70) 11.0 (5.00) 10.8 (4.90) 10.8 (4.90) 12.1 (5.50) 12.8 (5.80) 11.7 (5.30) 11.0 (5.00) Electrical Specifications 30 A 2-pole input breaker Amp Rating Input Power Connections Hardwire terminal block 3W + G (L-L-N-G) Output Power Connections Hardwire terminal block 3W + G (L-L-N-G) (1) L14-30R on a 300 mm cord (4) 5-20R (1) L14-30 (1) L6-30R (2) 5-20R (2) L6-20R (4) 5-20R (2) L6-30 (4) L5-20R (2) L5-30R (1) L6-30P (4) L5-20R (2) L6-30R (4) L6-20R (2) L6-20R (2) L6-30R * Standard on S4K4U6000C units Table 7: Power Distribution Specifications for S4K6U10KC Parameters Model Number S4KPAD2-101C S4KPAD2-102C S4KPAD2-103C S4KPAD2-104C S4KPAD2-105C S4KPAD2-106C Dimensions, W x D x h, in. (mm) 7.40 x 5.70 (188.0 x 145.0) Unit 11.90 x 20.60 x 8.70 (302.0 x 522.0 x 220.0) Shipping Weight, lbs. (kg) Unit 4.4 (2.00) 6.6 (3.00) 4.4 (2.00) 6.6 (3.00) Shipping 6.6 (3.00) 8.8 (4.00) 6.6 (3.00) 8.8 (4.00) (4) 5-20R (2) L5-30R (2) L5-20R (4) L6-20R (4) L5-20R Electrical Specifications Amp Rating 60 A 2-pole input breaker Input Power Connections Hardwire terminal block 3W + G (L-L-N-G) to chassis Output Power Connections (2) L6-30 (8) 5-20R (4) L6-20R (4) 5-20R (4) 5-20R (4) L6-30R (4) 5-20R (2) L6-30R (2) L6-20R Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 83 2 Uninterruptible Power Systems S4KC Accessories Hardware for Rack Mount (order part number separately) Catalog Number Optional Equipment Approx. Ship Weight lbs (kg) Description Catalog Number Rack Slide Kits SRS1832 Rack slide kit for racks with 18-32" deep support rails. Description Communications Options 8 (3.6) SNMPWEB CARD Ethernet communications kit, (Supports SNMP, HTTP and OCP) includes SNMP hardware, MIB, configuration cable and installation manual. IS-RELAY Relay contact board, 2 relay contact signals each independently configured for "On Battery", "Low Battery", "On Bypass", "On UPS", "Summary Alarm" and "UPS Fault" (rated at 24V @ 1 Amp AC or DC). Power A/C Distribution (PAD) PADs provide output distribution, input connection and a rotary maintenance bypass switch. The PAD is field installed by the customer and allows the UPS to be removed without interrupting power to the load. Catalog Number Description Series A2D115HW 120 Volt, Hardwired for use with 15 Amp Input S4K2U-C (700 - 1500 VA Models) A2D120HW 120 Volt, Hardwired for use with 20 Amp Input S4K2U-C (2000 VA Model) A2D130HW 120 Volt, Hardwired for use with 30 Amp input S4K2U-C (3000 VA Model) A2D220HW5 230 Volt, Hardwired for use with 10 Amp input S4K2U-C (1000-2000 VA Model) A2D230HW5 230 Volt, Hardwired for use with 15 Amp input S4K2U-C (3000 VA Model) S4KPAD2-001C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (4)5-20 (1) L14-30 (1) L6-30R S4K4U6000C S4KPAD2-002C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (2) 5-20R, (2) L6-20R S4K4U6000C S4KPAD2-003C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (4) 5-20R, (2) L6-30 S4K4U6000C S4KPAD2-004C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (4) L5-20R, (2) L5-30R S4K4U6000C S4KPAD2-005C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (4) L5-20R, (2) L6-30R S4K4U6000C S4KPAD2-006C 208/120 V or 240/120 V, Plug-n-Play L14-30P, (4) L6-20R S4K4U6000C S4KPAD2-101C 208/120 V or 240/120 V, Output Distribution, (2) L6-30 (8) 5-20R S4K6U10KC S4KPAD2-102C 208/120 V or 240/120 V, Output Distribution, (4) L6-20R, (4) 5-20R S4K6U10KC S4KPAD2-103C 208/120 V or 240/120 V, Output Distribution, (4) 5-20R, (4) L6-30R S4K6U10KC S4KPAD2-104C 208/120 V or 240/120 V, Output Distribution, (4) 5-20R, (2) L6-30R, (2) L6-20R S4K6U10KC S4KPAD2-105C 208/120 V or 240/120 V, Output Distribution, (4) 5-20R, (2) L5-30R, (2) L5-20R S4K6U10KC S4KPAD2-106C 208/120 V or 240/120 V, Output Distribution, (4) L6-20R, (4) L5-20R S4K6U10KC Note: PADs can only be used with units having matching receptacles for the line cords provided. 84 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 2 Uninterruptible Power Systems Table 8: Battery Backup Times Model Rating Number of Batteries/Cabinets Load % of Capacity 6000 VA 10000 VA Backup Time in Minutes 10% Internal battery Internal battery + 1 external battery cabinet Internal battery + 2 external battery cabinets Internal battery + 3 external battery cabinets 94 100 20% 43 46 30% 26 28 40% 17 18 50% 13 14 60% 10 11 70% 8 9 80% 6 7 90% 5 6 100% 4 5 10% 154 159 20% 96 102 30% 53 65 40% 44 46 50% 34 37 60% 26 28 70% 21 23 80% 17 18 16 90% 15 100% 13 14 10% 201 210 20% 136 141 30% 97 103 40% 69 74 50% 50 52 60% 44 46 70% 37 40 80% 31 34 28 90% 26 100% 22 25 10% 304 310 20% 156 160 30% 127 133 40% 97 103 50% 74 79 60% 60 65 70% 49 51 80% 44 46 90% 39 42 100% 34 37 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 85 2 Uninterruptible Power Systems Table 8: Battery Backup Times cont. Model Rating Number of Batteries/Cabinets Load % of Capacity 6000 VA 10000 VA Backup Time in Minutes Internal battery + 4 external battery cabinets 10% 322 327 20% 180 190 30% 145 149 40% 122 128 50% 98 103 60% 77 82 70% 66 71 80% 52 60 90% 48 50 100% 44 46 The factory default is programmed for internal batteries only. Table 8 shows the estimated battery backup times at different loads. The user may specify the number of external battery cabinets attached to the UPS. 86 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com.