Engineering Data
Switch Form: 1 Form A (SPST-NO)
Duty: Continuous.
Operating Temperature: –30°C to +80°C.
Storage Temperature: –30°C to 100°C.
Potting Compound Flammability: UL94V-0.
Approximate Weight: 1.38 oz. (35g).
IAC-5
IAC-5A
IAC-5E
IAC-15
IAC-24
Ordering Information
* * Is not polarity sensitive.
Features
• Industry standard package and pin-out.
• Color coded by function.
• 4000V rms optical isolation.
• High immunity to false operation.
• Series compatible.
• Compatible with 2IO series mounting boards.
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
Typical Part Number > IAC -5 A
1. Basic Series: IAC = AC input module - yellow case
2. Logic Voltage: 5 = 5VDC
15 = 15VDC
24 = 24VDC
3. Input: Blank = 120VAC input (90-140VAC) * *
A = 240VAC input (180-280VAC) * *
E = 18-36VAC input * *
Input Specifications
Parameter Conditions Units
IAC-5
IAC-15 IAC-24
IAC-5A
IAC-15A IAC-24A
IAC-5E
IAC-15E IAC-24E
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
Control Voltage Range VIN VAC 90 120 140 180 240 280 18 24 36
Must Operate Voltage VIN(OP) VAC 90 180 18
Must Release Voltage VIN(REL) VAC 60 60 10
Max. Input Current @VIN=Max. mA 1 - 5 1 - 8 0.2 - 2.0
Input Resistance Ohms Current Regulator
Solid State Relay
IAC Series
02-2019, Rev. 0219
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Potter & Brumfield
File E29244
Users should thoroughly review the technical data before selecting a
product part number. It is recommended that users also seek out the
pertinent approvals files of the agencies/laboratories and review them to
ensure the product meets the requirements for a given application.
AC Input Module
Output Specifications (@ +25˚C unless otherwise specified)
Parameter Conditions Units
IAC-5
IAC-5A IAC-5E
IAC-15
IAC-15A IAC-15E
IAC-24
IAC-24A IAC-24E
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
Maximum Output Voltage VDC 30 30 30
Maximum Output Current mADC 50 50 50
Maximum Output Leakage Current VOUT=Max. mA 10 10 10
Maximum Output Voltage Drop ISINK=50mA VDC 0.2 0.2 0.2
Logic Supply Voltage VCC VDC 3 5 6 12 15 18 20 24 30
Logic Supply Current VCC=Max. mADC 15 15 15
Turn-On Time (Nominal) ISINK=25mA ms 20 20 20
Turn-Off Time (Nominal) ISINK=25mA ms 30 30 30
Output Type (Open Collector) Normally Open(SINKING) Normally Open(SINKING) Normally Open(SINKING)
IAC Operating Diagram
Outline Dimensions
AC Input Module
PCB Layout
Solid State Relay
IAC Series(Continued)
02-2019, Rev. 0219
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
2
Potter & Brumfield
Note : Extra nut and washer will be provided on the screw, which will goes under PCB to fix the relay.
Hex Nut S= 6.35 (width across flats), Thickness = 2.40
Washer = OD : 4.85±0.25, ID: 2.75±0.15, Thickness = 0.55