40
Capacitance Voltage Rating DC (VR) at 85°C
μF Code 2.0V 3.0V 4.0V 6.3V 10V 16V 20V 25V
0.33 334
0.47 474
0.68 684
1.0 105 R(3000)
1.5 155
2.2 225
3.3 335 L(5000)
4.7 475 L(5000)
6.8 685
10 106 L(4000) L(4000),R(1800) R(1800)
15 156 R(1800) R(1500)
22 226 R(1800) R(1500)
33 336 R(1800) R(1500)
47 476 R(1500)
68 686
TPC Series
Low ESR TACmicrochip®
LOW ESR RANGE
(LETTER DENOTES CASE SIZE) (ESR in mΩ)
Rated DCL DF ESR 100kHz Ripple Current Ratings (A) 100kHz Ripple Voltage Ratings (V)
AVX EIA Case Capacitance Voltage (μA) % Max. (mΩ)
Part No. Size (μF) (V) Max. Max. @100kHz 25°C 85°C 125°C 25°C 85°C 125°C
TPCR336*003# 0805 R 33 3.0 1.0 10 1800 0.158 0.142 0.063 0.285 0.256 0.114
TPCR476*003# 0805 R 47 3.0 1.5 10 1500 0.173 0.156 0.069 0.260 0.234 0.104
TPCR226*004# 0805 R 22 4.0 0.9 8 1800 0.158 0.142 0.063 0.285 0.256 0.114
TPCR336*004# 0805 R 33 4.0 1.3 10 1500 0.173 0.156 0.069 0.260 0.234 0.104
TPCL106M006# 0603 L 10 6.3 0.6 10 4000 0.079 0.071 0.032 0.316 0.285 0.126
TPCR156*006# 0805 R 15 6.3 0.9 8 1800 0.158 0.142 0.063 0.285 0.256 0.114
TPCR226*006# 0805 R 22 6.3 1.4 10 1500 0.173 0.156 0.069 0.260 0.234 0.104
TPCL335*010# 0603 L 3.3 10.0 0.5 8 5000 0.071 0.064 0.028 0.354 0.318 0.141
TPCL475M010# 0603 L 4.7 10.0 0.5 10 5000 0.071 0.064 0.028 0.354 0.318 0.141
TPCL106M010# 0603 L 10 10.0 1.0 20 4000 0.079 0.071 0.032 0.316 0.285 0.126
TPCR106*010# 0805 R 10 10.0 1.0 8 1800 0.158 0.142 0.063 0.285 0.256 0.114
TPCR156*010# 0805 R 15 10.0 1.5 10 1500 0.173 0.156 0.069 0.260 0.234 0.104
TPCR106*016# 0805 R 10 16.0 1.6 10 1800 0.158 0.142 0.063 0.285 0.256 0.114
TPCR105*025# 0805 R 1.0 25.0 0.5 8 3000 0.122 0.110 0.049 0.367 0.331 0.147
RATINGS & PART NUMBER REFERENCE
All technical data relates to an ambient temperature of +25°C. Capacitance and DF
are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is
measured at rated voltage after 5 minutes.
* Insert K for ±10% and M for ±20% Capacitance Tolerance
NOTE: AVX reserves the right to supply a higher voltage rating or tighter
tolerance part in the same case size, to the same reliability standards.
The EIA & CECC standards for Low ESR Solid Tantalum Capacitors
allow an ESR movement to 1.25 times catalog limit post mounting.