Technical Support: (888) 41- A STEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
122
Special Features
Electrical Specs
250 Watts
LPS250 Series
Input
Input range 85-264 VAC; 120-300 VDC
Frequency 47-440 Hz
Inrush current 20 A max., cold start @ 25°C
Efficiency 75% t ypical at full load
EMI filter FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated EN55022 Class B conducted
and radiated VDE 0878 PT3 Class B
conducted and radiated
Power factor 0.99 t ypical
Safet y ground
leakage current <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power With cover: 250 W with 30 CFM forced
air.
(-C) (-CF) (CEF)
Adjustment range 2:1 wide ratio
Supervisory output 5 V @ 100 mA regulated; 12V @ 500
mA
Hold-up time 20 ms @ 250 W load, 115 VAC nominal
line
at factor y voltage setting
Overload protection Shor t circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
Over voltage protection 5 V output: 5.7 to 6.7 VDC.
Other models 10% to 25% above
nominal output
Logic Control
Power failure T TL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation
Remote on/off Requires an external contact (N.O or
N.C) to inhibit outputs
DC-OK T TL logic goes high 50-150 msec after
the output. It goes low when there is
loss of regulation.
Remote sense Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense & remote inhibit
•Power fail
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 2 Supervisory outputs 5 V and 12 V
• Over voltage protection
• Overload protection
• Thermal overload protection
• DC power good
•Cover -C
• 120 kHz switching frequency
• Optional top with fan cover -CF
• Optional end fan cover -CEF
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibilit y: Designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidit y: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditionsation
Environmental
Total Power: 250 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
rev 12.01.03
VDE 0805/EN60950 (IEC950) 11774-3336-1262
UL UL1950 E132002
CSA CSA 22.2-234 Level 5 LR53982C
NEMKO EN 60950/EMKO-TUE P95103550
(74-sec) 203
CB Certificate and report 2186
CE Mark (LVD)
Safety