Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
CN-M (ACNM)
ASCTB224E 201201-T
ORDERING INFORMATION
TYPES
1. PC board terminal type
Standard packing; Carton (tube): 50 pcs.; Case: 1,500 pcs.
2. Surface-mount terminal type
Standard packing; Carton (tape and reel): 200 pcs.; Case: 600 pcs.
Notes: *1. Surface-mount terminal type is available in high heat-resistant type only.
*2. An “X” at the end of the part number indicates, for tape and reel packing, reverse NO terminal direction in pull-out direction.
A “Z” at the end of the part number indicates, for tape and reel packing, normal NO terminal direction in pull-out direction.
MIDDLE LOAD RELAY
FOR SMART J/B
CN-M RELAYS (ACNM)
Contact arrangement Nominal coil voltage Part No.
Standard type High heat-resistant type
1 Form A 12V DC ACNM3112 ACNM7112
1 Form C ACNM1112 ACNM5112
Contact arrangement Nominal coil voltage Part No.
High heat-resistant type
1 Form A
12V DC
ACNM7112SAX
ACNM7112SAZ
1 Form C ACNM5112SAX
ACNM5112SAZ
RoHS compliant
FEATURES
• Best space savings in its class.
2. Compact and high-capacity 30A
load switching.
• Full line up (High heat-resistant type
and SMD type)
Terminals for PC board pattern
designs are easily allocated.
TYPICAL APPLICATIONS
Defogger, Seat heater, Head lamp, Fog
lamp, Fan motor, etc.
Contact arrangement*1
1: 1 Form C
3: 1 Form A
5: 1 Form C high heat-resistant type
7: 1 Form A high heat-resistant type
Packing style*2
Nil:
X:
Z:
Tube packing
Tape and reel packing
(Reverse NO terminal direction in pull-out direction)
Tape and reel packing
(Normal NO terminal direction in pull-out direction)
ACNM
Pick-up voltage
1: Max. 7.2V DC
Coil voltage (DC)
12: 12V
Terminal shape
Nil:
SA:
PC board terminal
Surface-mount terminal
Notes: *1. Surface-mount terminal type is available in high heat-resistant type only.
*2. Tube packing: PC board terminal type only
Tape and reel packing: Surface-mount type only
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
CN-M (ACNM)
ASCTB224E 201201-T
RATING
1. Coil data
2. Specifications
Note: *This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load.
REFERENCE DATA
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Usable voltage range
12 V DC Max. 7.2 V DC
(Initial)
Min. 1.0 V DC
(Initial) 53.3 mA 225640 mW 10 to 16 V DC
Characteristics Item Specifications
Contact
Arrangement 1 Form A, 1 Form C
Contact resistance (Initial) Typical 5m (By voltage drop 6 V DC 1 A)
Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity (resistive load) N.O.: 30A 14V DC, N.C.: 15A 14V DC
Max. carrying current (at 14V DC)
N.O.
30A/1 h, 40A/2 min. at 20°C 68°F
25A/1 h, 35A/2 min. at 85°C 185°F
20A/1 h, 30A/2 min. at 110°C 230°F (High heat-resistant type)
N.C.
25A/1 h, 30A/2 min. at 20°C 68°F
20A/1 h, 25A/2 min. at 85°C 185°F
15A/1 h, 20A/2 min. at 110°C 230°F (High heat-resistant type)
Nominal operating power 640 mW
Min. switching capacity (resistive load)* 1A 12V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100 M (at 500 V DC)
Breakdown
voltage (Initial)
Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Release time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial) (without protective element)
Mechanical
characteristics
Shock
resistance
Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration
resistance
Functional 10 Hz to 100 Hz, Min. 44.1m/s2 {4.5G} (Detection time: 10µs)
Destructive 10 Hz to 500 Hz, Min. 44.1m/s2 {4.5G}
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
<Resistive load>
Min. 105 (At nominal switching capacity, operating frequency: ON 1s, OFF 2s)
<Motor load>
Min. 2×105: at 80 A (inrush), 16 A (steady), 14 V DC (Operating frequency: ON 2s, OFF 6s)
<Lamp load>
Min. 105: at 84 A (inrush), 12 A (steady), 14 V DC (Operating frequency: ON 1s, OFF 14s)
Conditions Conditions for operation, transport and storage
Standard type;
Ambient temperature: –40°C to +85°C –40°F to +185°F, Humidity: 5 to 85% R.H.
High heat-resistant type;
Ambient temperature: –40°C to +110°C –40°F to +230°F, Humidity: 2 to 85% R.H.
(Not freezing and condensing at low temperature)
Mass Approx. 5.5 g .19 oz
1-(1). Coil temperature rise
Sample: ACNM1112, 3pcs
Measured portion: Inside the coil
Contact carrying current: 10A, 20A, 30A
Ambient temperature: 26°C 78.8°F
1-(2). Coil temperature rise
Sample: ACNM7112, 3pcs
Measured portion: Inside the coil
Contact carrying current: 10A, 20A
Ambient temperature: 110°C 230°F
2. Ambient temperature and operating voltage
range
0
140
80
60
40
20
12 14 16 1810
10A
20A
30A
100
120
Coil applied voltage, V
Te mperature rise, °C
0
140
120
100
80
60
40
20
12 14 16 1810
10A
20A
Coil applied voltage, V
Te mperature rise, °C
-40 -20 0 20 40 60 80 100 120
20
15
10
5
0
Pick-up voltage (cold start)
Ambient temperature, °C
Coil applied voltage, VDC
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
CN-M (ACNM)
ASCTB224E 201201-T
3. Distribution of pick-up and drop-out voltage
Sample: ACNM1112, 20pcs.
4. Distribution of operate and release time
Sample: ACNM1112, 20pcs.
0
10
5
15
20
012.0 3.0 5.04.0 6.0 7.0 8.0
Voltage, V
Quantity, n
Pick-up voltage
Drop-out voltage
0
10
5
15
20
012.0 3.0 5.04.0 6.0 7.0 8.0
Time, ms
Quantity, n
Operate time
Release time
5-(1). Electrical life test (Resistive load)
Sample: ACNM1112, 3pcs.
Load: Resistive load (NO side: 30A 14V DC)
Operating frequency: ON 1s, OFF 1s
Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
14V DC
0105
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 104
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
Max.
x
Min.
Max.
x
Min.
0105
20
30
10
15
25
5
0
No. of operations, × 104
Max.
x
Min.
Contact resistance, m
5-(2). Electrical life test (Motor load)
Sample: ACNM7112, 3pcs.
Load: inrush: 80A/steady: 16A
Operating frequency: ON 2s, OFF 6s
Ambient temperature: 110°C 230°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
14V DC
M
02010
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 104
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time Max.
x
Min.
Max.
x
Min.
02010
20
30
10
15
25
5
0
No. of operations, × 104
Contact resistance, m
Max.
x
Min.
5-(3). Electrical life test (Lamp load)
Sample: ACNM3112, 3pcs.
Load: inrush: 84A/steady: 12A
Operating frequency: ON 1s, OFF 14s
Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
14V DC 60W 60W
0105
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 104
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
Max.
x
Min.
Max.
x
Min.
0105
20
30
10
15
25
5
0
No. of operations, × 104
Contact resistance, m
Max.
x
Min.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
CN-M (ACNM)
ASCTB224E 201201-T
DIMENSIONS (mm inch)
1. PC board terminal type
2. Surface-mount terminal type
External dimensions
10.95
.431
4.65
.183
2.95
.116
1.2
1.2
A
11
.433
15.5
.610
1.2
.047
.047
.047
Pre-soldering
Max. 1.0 .039
3.5
14.4
.138
.567
0.4
.016
8
.315
Dimension: General tolerance
Max. 1mm .039 inch:±0.1 ±.004
1 to 3mm .039 to .118 inch:±0.2 ±.008
Min. 3mm .118 inch:±0.3 ±.012
PC board pattern
(Bottom view)
1 Form A
1 Form C
4.65
.183
10.95
.431
5×1.5 dia.
8
.315
+0.1
0
5×.059 dia.
+.004
0
4.65
.183
10.95
.431
6×1.5 dia.
8
.315
+0.1
0
6×.059 dia.
+.004
0
Schematic
(Bottom view)
1 Form A
1 Form C
COM NCCOIL
COM NOCOIL
COM NCCOIL
COM NOCOIL
Tolerance: ±0.1 ±.004
* Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
External dimensions
11
10.95
.431
4.65
.183
2.95
.116
14.8
.583
1.2
1.2
15.5
.433.610
1.2
.047
.047
.047
Pre-soldering
0.1
15.1
14.4
.594
.567
8
.315
Dimension: General tolerance
Max. 1mm .039 inch:±0.1 ±.004
1 to 3mm .039 to .118 inch:±0.2 ±.008
Min. 3mm .118 inch:±0.3 ±.012
Recommended mounting pad
(Top view)
1 Form A
1 Form C
5×1.7
5×.067
11.2
4.6
.441
.181
4.65
.183
10.95
.431
6×1.7
6×.067
11.2
4.6
.441
.181
4.65
.183
10.95
.431
Schematic
(Top view)
1 Form A
1 Form C
COM NOCOIL
COM COIL
COM NOCOIL
COM NCCOIL
Tolerance: ±0.1 ±.004
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
CN-M (ACNM)
ASCTB224E 201201-T
NOTES
For Cautions for Use.
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%. However,
check it with the actual circuit since the
characteristics may be slightly different.
2. Coil applied voltage
To ensure proper operation, the voltage
applied to the coil should be the rated
operating voltage of the coil. Also, be
aware that the pick-up and drop-out
voltages will fluctuate depending on the
ambient temperature and operating
conditions.
3. Cycle lifetime
Check this with the real device as it is
affected by coil driving circuit, load type,
activation frequency, activation phase,
ambient conditions and other factors.
4. Soldering
When soldering the relays, ensure
conformance with the conditions listed
below.
1) Automatic soldering
• Preheating: less than 100°C 212°F
(solder target surface of PC board) for
less than 120 sec
• Soldering: less than 260°C 500°F
(solder temperature) for less than 5 sec
(soldering time)
2) Manual soldering
• Soldering tip temperature: less than 280
to 300°C 536 to 572°F
• Soldering iron: 30 to 60 W
• Soldering time: less than 5 sec
5. Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +85°C –40 to +185°F
(Standard type)
–40 to +110°C –40 to +230°F
(High heat-resistant type)
(2) Humidity: 2 to 85% RH
(Avoid freezing and condensation.)
(3) Atmospheric pressure: 86 to 106 kPa
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(Temperature and humidity range for
usage, transport, and storage)
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
6. Others
If the relay has been dropped, the
appearance and characteristics should
always be checked before use.
85
5
2
110850–40 +230+185+32–40
Humidity, %RH
Temperature, °C°F
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
850–40 +185+32–40
Te mperature, °C°F