29
HOW TO ORDER BY MILITARY PART NUMBER
MIL-C-5015 CONNECTORS
WITH REAR RELEASE CRIMP CONTACTS
MS 3456 L16S –8 P W
1234567
1. Connector Type
MS designates Military Standard
2. Connector Style
THREADED COUPLING CONNECTORS
3450 wall mounting receptacle
3451 cable connecting receptacle
3452 box mounting receptacle
3454 jam nut receptacle
3456 straight plug
3459 straight plug with self-locking coupling nut
3. Service Class
L aluminum shell, electroless nickel finish, fluid resis-
tant insert
W aluminum shell, cadmium olive drab finish, fluid
resistant insert
LS stainless steel shell, passivated, fluid resistant
insert
KT firewall, steel shell, cadmium olive drab finish, non-
flammable hard dielectric and fluid resistant insert
KS firewall, stainless steel shell, passivated, non-flam-
mable hard dielectric and fluid resistant insert
Note: Class L inactivates older Class U.
Class K is inactive and has been replaced by Class KT for all
applications.
4., 5. Shell size and insert arrangement - See tables on pages
11 and 12 and pattern drawings that follow.
6. Contact Types
P designates pin
S designates socket
A designates less pins
B designates less sockets
Note: Use A & B only when other than a full complement of power con-
tacts is to be installed.
7. Insert Rotation
“W”, “X”, “Y”, “Z” designate that insert is rotated in its shell
from normal position. No letter required for normal (no
rotation) position. See page 13 for description of alternate
positions.
MS/Standard
how to order
HOW TO ORDER BY PROPRIETARY PART NUMBER
MIL-C-5015 CONNECTORS
WITH REAR RELEASE CRIMP CONTACTS
944 6 F 16S –8 P W ***
12 3 4 56 78
1. Connector Type
944 designates Amphenol®/Matrix® Series Number
2. Connector Style
THREADED COUPLING CONNECTORS
9440 wall mounting receptacle
9441 cable connecting receptacle
9442 box mounting receptacle
9444 jam nut receptacle
9446 straight plug
9816 straight plug with self-locking coupling nut
9817 quick disconnect plug with lanyard
9818 quick disconnect plug without lanyard
3. Service Class
A aluminum shell, black anodize finish, fluid resistant
insert (not MIL-Spec)
F aluminum shell, electroless nickel finish, fluid resis-
tant insert
W aluminum shell, cadmium olive drab finish, fluid
resistant insert
FS stainless steel shell, passivated, fluid resistant
insert
RS fluid resistant insert
KT firewall, steel shell, cadmium/olive drab finish, non-
flammable hard dielectric and fluid resistant insert
KS firewall, stainless steel shell, passivated, non-flam-
mable hard dielectric and fluid resistant insert
4., 5. Shell size and insert arrangement - See tables on pages
11 and 12 and pattern drawings that follow.
6. Contact Types
P designates pin
S designates socket
7. Insert Rotation
“W”, “X”, “Y”, “Z” designate that insert is rotated in its shell
from normal position. No letter required for normal (no
rotation) position. See page 13 for description of alternate
positions.
8. Modification Number
Consult Amphenol, Sidney, NY for information.
For strain reliefs use the following modification codes:
(189) E-nut M85049/31 configuration
(190) Straight strain relief M85049/52 configuration
(191) 90° strain relief M85049/51 configuration