2 Fluke Corporation 1587 FC/1577 Insulation Multimeters
Product Highlights
• PI/DAR timed ratio tests (1587 FC only)
• Live circuit detection prevents insulation test if voltage > 30 V is
detected for added user protection
• VFD low-pass filter for accurate motor drive measurements
(1587FC only)
• Auto-discharge of capacitive voltage for added user protection
• Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to
600MΩ)
• Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V,
1000 V),(1577: 500 V, 1000 V) for many applications
• AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω),
Continuity
• Capacitance, diode test, temperature, Min/Max, frequency (Hz)
(1587 FC only)
• Auto power off to save battery power
• CAT III 1000 V, CAT IV 600 V measurement category
• Large display with backlight
• Rugged, utility hard case allows you to bring everything you
need for the job
• Included accessories: Remote probe, test leads and probes,
alligator clips, (K-type thermocouple, 1587 FC only)
• Accepts optional Fluke TPAK Magnetic Meter Hanger for
convenient hands free operation
• Three-year standard warranty; extendable to five-years through
product registration within 45 days of purchase*
General Specifications
Maximum voltage applied to any terminal and
common
1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic compatibility
International IEC 61326-1: Portable Electromag-
netic Environment; IEC 61326-2-2 CISPR 11:
Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio
frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and
those directly connected to a low-voltage power supply network that supplies buildings
used for domestic purposes. There may be potential difficulties in ensuring electromag-
netic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is
connected to a test object. The equipment may not meet the immunity requirements of
this standard when test leads and/or test probes are connected.