(2/4)
001-02 / 20040525 / ea33_br_iaaba.fm
• All specifications are subject to change without notice.
SPECIFICATIONS AND STANDARDS
∗1 Verify the rated current (maximum output current) because this involves derating.
∗2 Load step from 50 to 100% of Io max. with at least one 0.1µF and 47µF ceramic capacitors across the output terminals.
∗3 Time to reaching to 90% by output voltage after input applies (t: Vin=0 to Vout=0.9Vo, nom. Tc=25°C, Io=Io, max.)
∗4 Time to reaching to 10 to 90% by output voltage (t: Co=0.1 to 0.9 Vo, nom.)
Part No. iAA05015A033V iAA05015A025V iAA05015A008V iBA05008A008V
Rated output voltage and current∗13.3V • 15A 2.5V • 15A 0.75 to 3.63V • 15A 0.75 to 3.63V • 8A
Maximum output power W 50 37.5 54.5 54.5
Input conditions
Input voltage Edc V 3 to 5.5[Continuation] 3 to 5.5[Continuation] 3 to 5.5[Continuation] 3 to 5.5[Continuation]
Transient input voltage V 6[100ms] 6[100ms] 6[100ms] 6[100ms]
Input current A 16max. 16max. 16max. 8max.
Efficiency % 89typ. 88typ. 86typ. 82typ.
Output characteristics
Output voltage Edc V 3.3 2.5 0.75 to 3.63 0.75 to 3.63
Voltage adjustment range % ±10 ±10 — —
Maximum output current A 15 15 15 8
Minimum output current A 0 0 0.02 0.02
Output voltage initial setting % ±2max. ±2max. ±2max. ±2max.
Overcurrent protection A 35typ. 35typ. 35typ. 17typ.
Voltage
stability
Line regulation mV 5max.(2typ.) 5max.(2typ.) 5max.(2typ.) 5max.(1typ.)
Load regulation mV 10max.(3typ.) 10max.(3typ.) 10max.(3typ.) 10max.(1typ.)
Temperature
regulation mV 60max.(15typ.) 60max.(15typ.) 60max.(15typ.) 60max.(15typ.)
Dynamic response∗2mV ±185typ. ±185typ. ±185typ. ±200typ.
Ripple noise Ep-p mV 75max. 75max. 75max. 75max.
Start up time∗3ms 14 14 14 14
Rise time∗4ms 10 10 10 10
Auxiliary functions
Overvoltage protection No
Overcurrent protection Yes(Automatic recovery)
Alarm output No
Over-temperature protection Yes(Automatic recovery)
Remote ON-OFF Yes
Remote sensing Yes(Only +)
Parallel operation Impossible
Output voltage adjustment Yes
Master slave operation No
Standards
Safety standards UL60950 and VDE0805 approved. EN60950 approved.
Constructions
External dimensions mm 8.0×13.5×33.2
[H×W×L]8.4×11.4×20.3
[H×W×L]
Weight g1212127
Mounting method Surface mounting method
Oscillating method Fixed frequency
Oscillating frequency kHz 350 400 350 350