SFH 7773
2012-02-20 24
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstr. 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics. Due to the
special conditions of the manufacturing processes of Sensor, the typical data or calculated correlations of technical
parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each
single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If
requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS.
1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
Pb-Free (SnAgCu) Assembly
Profile Feature Recommendation Max. Ratings
Ramp-up Rate to Preheat*)
25°C to 150°C
2°C / sec 3°C / sec
Time ts from TSmin to TSmax
(150°C to 200°C
100s min. 60sec max. 120sec
Ramp-up Rate to Peak*)
TSmax to TP
2°C / sec 3°C / sec
Liquidus Temperture TL217°C
Time tL above TL80sec max. 100sec
Peak Temperature TP245°C max. 260°C
Time tP within 5°C of the specified peak
temperature TP - 5K
20sec min. 10sec max. 30sec
Ramp-down Rate*
TP to 100°C
3°C / sec 6°C / sec maximum
Time 25°C to Peak temperature max. 8 min.
All temperatures refer to the center of the package, measured on the top of the component