10m 0.1 to 3m (Note 1) 500mm (Note 1) 700mm (Note 2)
"10mm or more opaque object (Note 3)
15% or less of operation distance
0.5mm or less 1mm or less 0.2mm or less 0.5mm or less
12 to 24V DCⳲ10% Ripple P-P 10% or less
50mA or less
NPN open-collector transistor
•Maximum sink current: 100mA
•Applied voltage: 30V DC or less (between sensing output and 0V)
•Residual voltage: 1.5V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
•Maximum sink current: 50mA
•Applied voltage: 30V DC or less (between self-diagnosis output and 0V)
•Residual voltage: 1V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
ON under unstable sensing or the sensor circuit failure conditions (Note 4)
3ms or less
Incorporated
Red LED (lights up when the sensing output is ON, blinks when the sensor circuit has failed) (Note 4)
Green LED lights up when the sensing output wire is disconnected, lights up under stable light received condition
or stable dark condition, and blinks under unstable sensing condition (Note 4)
Red LED (lights up during beam emission)
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted closely.)
Self-diagnosis of incident light intensity and internal circuit failure
IP67 (IEC)
ⳮ25 toⳭ60⬚C (No dew condensation or icing allowed), Storage:ⳮ30 toⳭ70⬚C
35 to 85% RH, Storage: 35 to 85% RH
Sunlight: 11,000?x at the light-receiving face, Incandescent light: 3,500?x at the light-receiving face
Power line: 240Vp, 10ms cycle, and 0.5!s pulse width; Radiation: 300Vp, 10ms cycle, and 0.5!s pulse width (with noise simulator)
1,000V AC for one min. between all supply terminals connected together and enclosure
20MΩ, or more, with 250V DC megger between all supply terminals connected together and enclosure
10 to 500Hz frequency, 1.5mm amplitude (10G max.) in X, Y and Z directions for two hours each
500m/s2acceleration (50G approx.) in X, Y and Z directions for three times each
Infrared LED (modulated) Red LED (modulated) Infrared LED (modulated)
Enclosure: Die-cast zinc alloy, Indicator cover: Polyethersulphone, Lens: Polycarbonate (retroreflective type: Acrylic)
0.15mm25-core (thru-beam type: 4-core) oil, heat and cold resistant cabtyre cable, 2m long
Extension up to total 100m is possible with 0.3mm2, or more, cable
(thru-beam type: both emitter and receiver).
Emitter: 70g approx., Receiver: 70g approx.
75g approx.
Sensing range
Sensing object
Hysteresis
Repeatability
(perpendicular to sensing axis)
Supply voltage
Current consumption
Sensing output
Output operation
Short-circuit protection
Self-diagnosis output
Output operation
Short-circuit protection
Response time
Test input
Operation indicator
Stability indicator
Emitting indicator
Sensitivity adjuster
Automatic interference prevention function
Self-diagnosis function
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Noise immunity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Material
Cable
Cable extension
Weight
Accessories
254
RX
PHOTOELECTRIC SENSORS
EQ-20
EQ-30
EX-40
RX-LS200
CY
EX
PX-2
RT-610 Amplifier Built-in Type RX
SPECIFICATIONS
Intelligent type
Environmental resistance
Type
Item Model No.
Thru-beam Retroreflective (with polarizing filters) Diffuse reflective
For transparent object sensing
RX3-M10 RX3-PRVM3 RX3-PRV500 RX3-D700
( )
MS-RX-1 (Sensor mounting bracket):
2 sets
Adjusting screwdriver: 1 No.
MS-RX-1 (Sensor mounting bracket): 1 set
RF-230 (Reflector): 1 No.
Adjusting screwdriver: 1 No.
MS-RX-1 (Sensor mounting bracket):
1 set
Adjusting screwdriver: 1 No.
Notes: 1) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the pos-
sible setting range for the reflector. The sensor can detect an object less than 0.1m away.