PR560 Reed Switch
www.standexmeder.com
Professional grade high voltage medium power applications reed switch with rhodium
contacts
Designed to give superior life switching relatively heavy loads
Physical Characteristics
A Glass Length (Max.) 14.2 mm
B Overall Length (Max.) 54.0 mm
C Glass Diameter (Max.) 2.3 mm
D Lead Diameter (Nom.) 0.6 mm
Electrical Characteristics
Contact Arrangement Form A (SPST), Center Gap
Contact Material Rhodium
Power Rating
1
10VA maximum
Switching Current (Max.) 1.0 Amp. DC, 1.0 Amp. AC
Carry Current (Max.) 1.5 Amp. DC, 1.5 Amp. AC
Switching Voltage (Max.) 250 VDC, 250 VAC
Breakdown Voltage (Min. @20AT)
2
600 Volts DC
Contact Resistance
3
100 Milliohms
Insulation Resistance (Min.) 10
12
ohms
Contact Capacitance (pf Max.) 0.2 pf
1.
The specification for VA rating may sometimes be exceeded for less sensitive (higher AT) switches, and should be
decreased for very sensitive (lower AT) switches. Standex-Meder Electronics will run life tests specific to a customer’s
load upon request.
2. Breakdown voltage is measured in the presence of a radioactive ionising source. Switch leakage current is limited to
100 microamperes
3. Contact resistance measurements are made at 10ma from a 1-volt source, with 50% overdrive, using a 4-wire (Kelvin)
measuring system. Contact probes are located on 43 mm centres.
Minimum Switching Life with Standard Test Loads, using 20AT switch
Voltage 24 VDC 100 VDC 125 VAC 240 VDC 240 VAC
Current 10 mA 100 mA 80 mA 40 mA
40 mA
Life 5 x 10
6
1 x 10
6
1 x 10
6
2 x 10
5
5 x 10
5
Note:
End of life is defined as contact resistance exceeding one ohm and/or failure to operate.
A Glo
bal Leader in the Design, Development, and
Manufacture of Sensors and Magnetic Components
Product Solutions
www.standexmeder.com
REACH & RoHS Compliant
A Global Leader in the Design, Development, and
Manufacture of Sensors and Magnetic Components
PR560 Reed Switch
www.standexmeder.com
Operating Characteristics
Magnetic Sensitivity (Range - Pull In) 20 to 40 Ampere Turns
Magnetic Sensitivity (Range - Drop Out) (See chart below)
Operate Time, including bounce (typ.) 0.6 Milliseconds
Release Time (typ.) 0.1 Milliseconds
Resonant Frequency (typ.) 3.0 kHz
Vibration, 10-2,000 Hz (G's Max.) 50 G
Shock, 11-ms. 1/2 Sine wave (G's Max.) 100 G
Operating Temperature -40°C to + 125°C
Storage Temperature -50°C to + 155°C
Charts
Breakdown Voltage Plotted
Against Pull-In Ampere Turns
Pull-In Ampere Turns Plotted
Against Drop-Out Ampere Turns
Change In Pull-In Ampere Turns
After Switch Lead Cutting
Change In Drop-Out Ampere Turns
After Switch Lead Cutting