R.41
Y2 / X1 CLASS (IEC 60384-14) MKP Series
METALLIZED POLYPROPYLENE FILM CAPACITOR
Typical applications
failure of the capacitor could lead to danger of electric shock.
R41
Note: R.41 series has replaced the R73 series (available
use of the R.41 series.
GENERAL TECHNICAL DATA
Dielectric:
Plates: metal layer deposited by evaporation under vacuum.
Winding: non-inductive type.
Leads:
Protection:
UL94 V0.
Marking: Manufacturer’s logo, series, capacitance, tolerance,
rated voltage, capacitor class, dielectric code, climatic
code, approvals, manufacturing plant.
Climatic category: 40/110/56 IEC 60068-1
Operating temperature range:
Related documents: IEC 60384-14, EN 60384-14.
ELECTRICAL CHARACTERISTICS
Rated voltage (VR):
Capacitance range: 1000pF to 1.0µF
Capacitance values: E6 series (IEC 60063 Norm).
Capacitance tolerances (measured at 1 kHz):
±±20% (M).
Dissipation factor (DF):
tgδ x 10-4± 30 (20)* at 1kHz
* Typical value
Insulation resistance:
Test conditions
±5°C
Performance
1 x 105 MΩ (5 x 105 MΩ )* for C 0.33µF
30000 s (150000 s)* for C >0.33µF
* Typical value
Test voltage between terminations
±5°C
Ø
d ±0.05
p = 7.5 p = 10 p = 15 15<p27.5 p = 37.5
0.5 0.6 0.6 or 0.8* 0.8 1
* See size table.
All dimensions are in mm.
Loose Taped
Fig.1 Fig.2
TEST METHOD AND PERFORMANCE
Damp heat, steady state:
Test conditions
±2°C
±2%
Performance
Capacitance change |∆ 5%
50% of initial limit.
Endurance:
Test conditions
±2°C
R
Performance
Capacitance change |∆ 10%
50% of initial limit.
Resistance to soldering heat:
Test conditions
±5°C
±1 s
Performance
Capacitance change |∆ 2%
Pitch Box thickness (B) Maximum dimensions (mm)
(mm) (mm) B max H max L max
7.5 All
10.0 All
15.0 <7.5
15.0
22.5 All
27.5 All
37.5 All