Miniature circuit-breaker FAZ,
Residual current device FI,
Fuse material
Tested quality, approvals and shipping
classifi cations represent the functionality and safety
suitable for world markets with Xpole industrial
miniature circuit-breakers. Moeller also provides a
comprehensive range of residual current devices,
low-voltage fuse switch-disconnectors and fuse-
load switch units.
Cylindrical fuse switch-
disconnectors
- With fl ashing function on tripped
fuse
- Sealable
Page 16/25
Miniature circuit-breakers
- Only 80 mm in height
- Installation and removal without
disassembly of the rails
- Double comfort terminal lift/claw
- Terminal with rear plug protection
Page 16/4
Fuse bases
- Integrated terminal covers
- Double terminals
Page 16/20
Busbar mounted switch-
disconnectors with D0 fuses
- Busbar system 60 mm,
5 mm or 10 mm Cu
- Simple installation
- Load switchable on all poles
- Fuse change without load
Part. no. D02-S/63/3-RS
Page 16/22
Low-voltage HRC switch-fuse
strips
- Pivoting current transformers
- Type series with fuse monitoring
- Mounting without holes with
claw clamp
- V-connection possible
Page 16/28
Moeller HPL0211-2007/2008
Contents 16/1
Miniature circuit-breakers
Residual-current circuit-breakers
Fuse bases,
Fuse switch-disconnectors
Miniature circuit-breakers,
residual-current circuit-breakers
Page
System overview 16/2
Ordering
FAZ-B miniature circuit-breakers 16/4
FAZ-C miniature circuit-breakers 16/6
FAZ-D miniature circuit-breakers 16/6
FAZ-PN miniature circuit-breakers 16/8
Miniature circuit-breakers for DC applications 16/9
AZ miniature circuit-breakers 16/10
Residual-current protective modules for FAZ and AZ 16/12
PKNM combined RCD/MCB devices (type A) 16/13
Residual current device FI, type A 16/14
Residual current device FI, type U, S/A, B 16/15
FI residual-current circuit-breakers for export (type AC) 16/16
Add-on functions: Auxiliary contacts, voltage releases, MCB lock 16/17
Busbars 16/18
Mounting accessories, miniature circuit-breakers, residual current
circuit-breakers 16/19
Remote switching modules 16/20
Engineering
Tripping characteristics 16/30
Let-through characteristics 16/32
Technical data
Miniature circuit-breakers 16/35
Residual-current circuit-breakers 16/36
Auxiliary contacts, voltage releases 16/37
Remote switching modules 16/39
Dimensions
Miniature circuit-breakers, residual-current circuit-breakers 16/46
Shunt release, undervoltage release, remote switching module 16/47
Busbars 16/48
Page
Ordering
Fuse bases 16/20
Mounting accessories, fuse material 16/21
Busbar mount switch-disconnector 16/22
Fuse switch-disconnector, fuse sets 16/23
Fuse switch-disconnector 16/25
LV h.b.c. fuse bases, LV h.b.c. fuse switch-disconnectors 16/26
Mounting accessories low-voltage h.b.c. fuse bases, low-voltage
h.b.c. fuse-switch disconnectors 16/27
Low-voltage h.b.c. switch-fuse units 16/28
Mounting accessories fuse-load switch units 16/29
Engineering
Let-through characteristics 16/34
Technical data
Fuse material 16/39
Fuse switch-disconnectors 16/41
Low-Voltage h.b.c. Fuse Switch-Disconnectors 16/42
Low-voltage h.b.c. switch-fuse units 16/43
Low-voltage h.b.c. fuse bases 16/45
Dimensions
Fuse bases, fuse switch-disconnectors 16/48
Fuse bases 16/49
Low-voltage h.b.c. switch-fuse units 16/51
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/2
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
System overview
Miniature circuit-breakers, residual-current circuit-breakers
FAZ
pole
X
pole
X
FAZ
X
XUA
AZ
XHI11
AZ-3N
AZ-3
XFSM
XFSM
FAZ-3
FAZ-2
AZ-2
AZ
AZ XAA
XPM0
FIP-4
FAZ-4
FAZ-2
FILS
4
5
5
3
2
3
10
12
1
9
1
1
1
11
11
6
13
7
9
6
6
6
8
11
AZFIM-4-125-0,3
FAZ
pole
X
FAZ
pole
X
FAZ
pole
X
FAZ
pole
X
pole
X
FAZ
pole
X
pole
X
FIM
PKNM
pole
X
FI-40
FI
pole
X
FI-40
pole
X
pole
X
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/3
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
System overview
Miniature circuit-breakers, residual-current circuit-breakers
Base units
Miniature circuit-breakers FAZ 1
Characteristics/rated curent ranges
B/4 63 A; C/0,5 63 A; D/6 40 A
Switching capacity:
15 kA to IEC/EN 60947-2
B, C, D characteristic
1-, 1N-, 2-, 3-, 3N-, 4-pole
Special miniature circuit-breakers for
auxiliary circuits (1 and 2 pole)
Special miniature circuit-breaker for DC-
applications up to 500 V DC
apage 16/4
FAZ-PN miniature circuit-breakers 2
Characteristic/rated current ranges
B/6 40 A; C/2 … 40 A
Switching capacity:
6 kA to IEC/EN 60898
B, C characteristic
1 N pole
apage 16/8
Residual current protective modules
for attachment to FAZ 3
Protection in the event of fault current
Rated current range 40 … 63 A
Rated fault current 30 mA, 300 mA
apage 16/12
Residual current protective modules
for attachment to AZ 12
Protection in the event of fault current
Rated current range 80 … 125 A
Rated fault current 30 mA, 300 mA
apage 16/12
PKNM combined RCD/MCB device 4
Overload, short-circuit protection and
protection with fault currents
Characteristic/rated current ranges
B/6-40 A; C/6-40 A; 1N pole
Switching capacity:
10 kA to IEC/EN 60898
Rated fault current 30 mA, 300 mA
apage 16/13
Residual-current circuit-breakers 5
AC current sensitive
2 pole 16 80 A
4 pole 25 80 A
Pulsed current sensitive
2 pole 16 40 A
4 pole 25 125 A
AC/DC
4 pole 40 125 A
Rated fault current
30 mA, 100 mA, 300 mA, 500 mA
4 pole selective, 63 80 A
Rated fault current
100 mA, 300 mA
4 pole frequency-inverter immune 40,
63 A
100 mA, 300 mA
apage 16/14
Miniature circuit-breakers AZ 6
Characteristic/rated current ranges C/20-
125 A; D/50-100 A
Switching capacity: 15 25 kA to IEC/
EN 60947-2, 1-, 2-, 3-, 3N-, 4-pole
apage 16/10
Add-on functions
Auxiliary contacts FAZ 7
Standard auxiliary contacts
Trip-indicating auxiliary contact
Auxiliary contacts
apage 16/17
Auxiliary contacts AZ 8
Standard auxiliary contacts
apage 16/17
FAZ voltage releases 9
Undervoltage release
Shunt release
Can be fitted to FAZ or FAZ-FIM
apage 16/17
Voltage releases AZ 10
Shunt release
apage 16/17
Residual-current auxiliary contact 13
Auxiliary contacts
apage 16/17
Remote switching module 11
Suitable for remote switching and auto-
matic restart of a miniature circuit-brea-
ker or RCCB, for remote trip testing of a
RCCB in conjunction with a remote test
module
a page 16/20
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/4
Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering Ordering
Miniature circuit-breakers Miniature circuit-breakers
1 pole 2 pole 3 pole 4 pole 2 pole 4 pole
With 2 protected poles With 3 protected poles With 4 protected poles With 1 protected pole, N
switching with pole With 3 protected poles, N
switching with poles
Rated current
Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Notes
I
n
A
Miniature circuit-breakers FAZ
Characteristic B
Instantaneous release
response current 3 … 5
x InSwitching capacity
15 kA (IEC/EN 60947-2)
4FAZ-B4/1-HS
279274 12 off FAZ-B4/2-HS
279275 1off
5FAZ-B5/1
278528
6FAZ-B6/1
278529 FAZ-B6/2
278728 FAZ-B6/3
278841 1 off FAZ-B6/4
279029 1 off FAZ-B6/1N
278642 1 off FAZ-B6/3N
278943 1 off
8FAZ-B8/1
278530 FAZ-B8/2
278729 FAZ-B8/3
278842 FAZ-B8/4
279030 FAZ-B8/1N
278643 FAZ-B8/3N
278944
10 FAZ-B10/1
278531 FAZ-B10/2
278730 FAZ-B10/3
278843 FAZ-B10/4
279031 FAZ-B10/1N
278644 FAZ-B10/3N
278945
12 FAZ-B12/1
278532 FAZ-B12/2
278731 FAZ-B12/3
278844 FAZ-B12/4
279032 FAZ-B12/1N
278645 FAZ-B12/3N
278946
13 FAZ-B13/1
278533 FAZ-B13/2
278732 FAZ-B13/3
278845 FAZ-B13/4
279033 FAZ-B13/1N
278646 FAZ-B13/3N
278947
15 FAZ-B15/1
278534 FAZ-B15/2
278733 FAZ-B15/3
278846 FAZ-B15/4
279034 FAZ-B15/1N
278647 FAZ-B15/3N
278948
16 FAZ-B16/1
278535 FAZ-B16/2
278734 FAZ-B16/3
278847 FAZ-B16/4
279035 FAZ-B16/1N
278648 FAZ-B16/3N
278949
20 FAZ-B20/1
278536 FAZ-B20/2
278735 FAZ-B20/3
278848 FAZ-B20/4
279036 FAZ-B20/1N
278649 FAZ-B20/3N
278950
25 FAZ-B25/1
278537 FAZ-B25/2
278736 FAZ-B25/3
278849 FAZ-B25/4
279037 FAZ-B25/1N
278650 FAZ-B25/3N
278951
32 FAZ-B32/1
278538 FAZ-B32/2
278737 FAZ-B32/3
278850 FAZ-B32/4
279038 FAZ-B32/1N
278651 FAZ-B32/3N
278952
40 FAZ-B40/1
278539 FAZ-B40/2
278738 FAZ-B40/3
278851 FAZ-B40/4
279039 FAZ-B40/1N
278652 FAZ-B40/3N
278953
50 FAZ-B50/1
278540 FAZ-B50/2
278739 FAZ-B50/3
278852 FAZ-B50/4
279040 FAZ-B50/1N
278653 FAZ-B50/3N
278954
63 FAZ-B63/1
278541 FAZ-B63/2
278740 FAZ-B63/3
278853 FAZ-B63/4
279041 FAZ-B63/1N
278654 FAZ-B63/3N
278955
2
1
2
1
4
3
246
135
46
53
2
1
8
7
2
1N
N
246
5
N
N31
Switching capacity
(IEC/EN 60898) 10 kA
Switching capacity
(IEC/EN 60947-2) 15 kA
Accessories
Auxiliary contacts a16/17
Voltage releases
Mounting accessories a16/18
FAZ-B4/1-HS, FAZ-B4/2-HS special miniature
circuit-breakers with much reduced let-throu-
gh energy to prevent contact welding of auxi-
liary contacts
1 pole
Depth 71 mm
Width 17.5 mm
2-pole; 1N-pole
Depth 71 mm
Width 35 mm
3 pole
Depth 71 mm
Width 52.5 mm
4-pole; 3-pole + N
Depth 71 mm
Width 70 mm
16/5
FAZ-B FAZ-B
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/6
Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering Ordering
Miniature circuit-breakers Miniature circuit-breakers
1 pole 2 pole 3 pole 4 pole 2 pole 4 pole
With 2 protected poles With 3 protected poles With 4 protected poles With 1 protected pole,
N switching with pole With 3 protected poles, N
switching with poles
Rated current Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Std.
pack Notes
I
n
A
Miniature circuit-breakers FAZ
Characteristic C
Instantaneous release
response current 5 … 10
x I
n
Switching capacity 15
kA (IEC/EN 60947-2)
0.5 FAZ-C0,5/1
278544 12 off FAZ-C0,5/2
278743 1 off FAZ-C0,5/3
278856 1 off FAZ-C0,5/4
279044 1 off FAZ-C,5/1N
278657 1 off FAZ-C0,5/3N
278958 1 off
1FAZ-C1/1
278546 FAZ-C1/2
278745 FAZ-C1/3
278858 FAZ-C1/4
279046 FAZ-C1/1N
278659 FAZ-C1/3N
278960
1.6 FAZ-C1,6/1
278548 FAZ-C1,6/2
278747 FAZ-C1,6/3
278860 FAZ-C1,6/4
279048 FAZ-C1,6/1N
278661 FAZ-C1,6/3N
278962
2FAZ-C2/1
278549 FAZ-C2/2
278748 FAZ-C2/3
278861 FAZ-C2/4
279049 FAZ-C2/1N
278662 FAZ-C2/3N
278963
3FAZ-C3/1
278551 FAZ-C3/2
278750 FAZ-C3/3
278863 FAZ-C3/4
279051 FAZ-C3/1N
278664 FAZ-C3/3N
278965
4FAZ-C4/1
278553 FAZ-C4/2
278752 FAZ-C4/3
278865 FAZ-C4/4
279053 FAZ-C4/1N
278666 FAZ-C4/3N
278967
6FAZ-C6/1
278555 FAZ-C6/2
278754 FAZ-C6/3
278867 FAZ-C6/4
279055 FAZ-C6/1N
278668 FAZ-C6/3N
278969
8FAZ-C8/1
278556 FAZ-C8/2
278755 FAZ-C8/3
278868 FAZ-C8/4
279056 FAZ-C8/1N
278669 FAZ-C8/3N
278970
10 FAZ-C10/1
278557 FAZ-C10/2
278756 FAZ-C10/3
278869 FAZ-C10/4
279057 FAZ-C10/1N
278670 FAZ-C10/3N
278971
13 FAZ-C13/1
278559 FAZ-C13/2
278758 FAZ-C13/3
278871 FAZ-C13/4
279059 FAZ-C13/1N
278672 FAZ-C13/3N
278973
16 FAZ-C16/1
278561 FAZ-C16/2
278760 FAZ-C16/3
278873 FAZ-C16/4
279061 FAZ-C16/1N
278674 FAZ-C16/3N
278975
20 FAZ-C20/1
278562 FAZ-C20/2
278761 FAZ-C20/3
278874 FAZ-C20/4
279062 FAZ-C20/1N
278675 FAZ-C20/3N
278976
25 FAZ-C25/1
278563 FAZ-C25/2
278762 FAZ-C25/3
278875 FAZ-C25/4
279063 FAZ-C25/1N
278676 FAZ-C25/3N
278977
32 FAZ-C32/1
278564 FAZ-C32/2
278763 FAZ-C32/3
278876 FAZ-C32/4
279064 FAZ-C32/1N
278677 FAZ-C32/3N
278978
40 FAZ-C40/1
278565 FAZ-C40/2
278764 FAZ-C40/3
278877 FAZ-C40/4
279065 FAZ-C40/1N
278678 FAZ-C40/3N
278979
50 FAZ-C50/1
278566 FAZ-C50/2
278765 FAZ-C50/3
278878 FAZ-C50/4
279066 FAZ-C50/1N
278679 FAZ-C50/3N
278980
63 FAZ-C63/1
278567 FAZ-C63/2
278766 FAZ-C63/3
278879 FAZ-C63/4
279067 FAZ-C63/1N
278680 FAZ-C63/3N
278981
Characteristic D
Instantaneous release
response current 10 … 20
x I
n
Switching capacity 15
kA (IEC/EN 60947-2)
6FAZ-D6/1
278578 12 off FAZ-D6/2
278777 1 off FAZ-D6/3
278890 1 off FAZ-D6/4
279078 1 off FAZ-D6/3N
278992 1 off
8FAZ-D8/1
278579 FAZ-D8/2
278778 FAZ-D8/3
278891 FAZ-D8/4
279079 FAZ-D8/3N
278993
10 FAZ-D10/1
278580 FAZ-D10/2
278779 FAZ-D10/3
278892 FAZ-D10/4
279080 FAZ-D10/3N
278994
13 FAZ-D13/1
278582 FAZ-D13/2
278781 FAZ-D13/3
278894 FAZ-D13/4
279082 FAZ-D13/3N
278996
16 FAZ-D16/1
278584 FAZ-D16/2
278783 FAZ-D16/3
278896 FAZ-D16/4
279084 FAZ-D16/3N
278998
20 FAZ-D20/1
278585 FAZ-D20/2
278784 FAZ-D20/3
278897 FAZ-D20/4
279085 FAZ-D20/3N
278999
25 FAZ-D25/1
278586 FAZ-D25/2
278785 FAZ-D25/3
278898 FAZ-D25/4
279086 FAZ-D25/3N
279000
32 FAZ-D32/1
278587 FAZ-D32/2
278786 FAZ-D32/3
278899 FAZ-D32/4
279087 FAZ-D32/3N
279001
40 FAZ-D40/1
278588 FAZ-D40/2
278787 FAZ-D40/3
278900 FAZ-D40/4
279088 FAZ-D40/3N
279002
2
1
2
1
4
3
246
135
46
53
2
1
8
7
2
1N
N
246
5
N
N31
Switching capacity
(IEC/EN 60898) 10 kA
Switching capacity
(IEC/EN 60947-2) 15 kA
Accessories Page
Auxiliary contacts,
voltage releases a 16/17
Mounting accessories a 16/18
1 pole
Depth 71 mm
Width 17.5 mm
2 pole; 1 N pole
Depth 71 mm
Width 35 mm
3 pole
Depth 71 mm
Width 52.5 mm
4 pole; 3N pole
Depth 71 mm
Width 70 mm
16/7
FAZ-C, FAZ-D FAZ-C, FAZ-D
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/8
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Miniature circuit-breakers
2 pole
With 1 protected pole, N
switching with pole
Rated current Part no.
Article no. Price
see price list Std. pack
In
A
FAZ-PN miniature circuit-breakers
Characteristic B Instantaneous release
response current 3 … 5 x InSwitching
capacity 6 kA (IEC/EN 60898)
6FAZ-PN-B6/1N
279146 12 off
10 FAZ-PN-B10/1N
279147
13 FAZ-PN-B13/1N
279148
16 FAZ-PN-B16/1N
279149
20 FAZ-PN-B20/1N
279150
25 FAZ-PN-B25/1N
279151
32 FAZ-PN-B32/1N
279152
40 FAZ-PN-B40/1N
279153
Characteristic C Instantaneous release
response current 5 … 10 x InSwitching
capacity 6 kA (IEC/EN 60898)
2FAZ-PN-C2/1N
279154 12 off
4FAZ-PN-C4/1N
279155
6FAZ-PN-C6/1N
279156
10 FAZ-PN-C10/1N
279157
13 FAZ-PN-C13/1N
279158
16 FAZ-PN-C16/1N
279159
20 FAZ-PN-C20/1N
279160
25 FAZ-PN-C25/1N
279161
32 FAZ-PN-C32/1N
279162
40 FAZ-PN-C40/1N
279163
2
1N
N
Accessories
Auxiliary contacts a16/17
Voltage releases
1 N pole
Depth 71 mm
Width 17.5 mm
FAZ-PN
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/9
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Miniature circuit-breaker for DC application
1 pole 2 pole
With 2 protected poles
Rated current Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price
list
Std.
pack
In
A
FAZ miniature circuit-breakers for DC
applicationsCharacteristic C
Instantaneous release response current 5
… 10 x In
Switching capacity 10 kA (IEC/EN 60947-
2) (L/R = 4 ms)
Rated voltage 250 V DC per pole
2FAZ-C2/1-DC
279122 12 off FAZ-C2/2-DC
279134 1 off
3FAZ-C3/1-DC
279123 FAZ-C3/2-DC
279135
4FAZ-C4/1-DC
279124 FAZ-C4/2-DC
279136
6FAZ-C6/1-DC
279125 FAZ-C6/2-DC
279137
10 FAZ-C10/1-DC
279126 FAZ-C10/2-DC
279138
13 FAZ-C13/1-DC
279127 FAZ-C13/2-DC
279139
16 FAZ-C16/1-DC
279128 FAZ-C16/2-DC
279140
20 FAZ-C20/1-DC
279129 FAZ-C20/2-DC
279141
25 FAZ-C25/1-DC
279130 FAZ-C25/2-DC
279142
32 FAZ-C32/1-DC
279131 FAZ-C32/2-DC
279143
40 FAZ-C40/1-DC
279132 FAZ-C40/2-DC
279144
50 FAZ-C50/1-DC
279133 FAZ-C50/2-DC
279145
Note Circuit design notes
Note polarity!
1 pole
2 pole
+
1
2
+
+
3
4
1
2
Accessories
Auxiliary contacts a16/17
Voltage releases
Mounting accessories a16/18
1 pole
Depth 71 mm
Width 17.5 mm
2-pole; 1N-pole
Depth 71 mm
Width 35 mm
+
1
2
+
0 V/L–
+250 V/L+
+
+250 V/L+
0 V/L–
+
+
3
4
1
2
+
+
0 V/L–
+500 V/L+
+
+500 V/L+
0 V/L– +
FAZ...-DC
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/10
Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering Ordering
Miniature circuit-breakers Miniature circuit-breakers
1 pole 2 pole 3 pole 4 pole 4 pole
With 2 protected poles With 3 protected poles With 4 protection poles
With 3 protection poles, N switching
with poles
Notes
Rated current Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price
list
Std. pack Part no.
Article no. Price
see price list Std. pack Part no.
Article no. Price
see price list Std. pack
I
n
A
Miniature circuit-breakers AZ
Characteristic C
Instantaneous release
response current 5 … 10
x I
n
Switching capacity
15 … 25 kA (IEC/EN
60947-2)
20 AZ-C20
211769 12 off AZ-2-C20
211770 2 off AZ-3-C20
211771 1 off AZ-4-C20
211772 1 off AZ-3N-C20
211773 1 off
25 AZ-C25
211774 AZ-2-C25
211775 AZ-3-C25
211776 AZ-4-C25
211777 AZ-3N-C25
211778
32 AZ-C32
211779 AZ-2-C32
211780 AZ-3-C32
211781 AZ-4-C32
211782 AZ-3N-C32
211783
40 AZ-C40
211784 AZ-2-C40
211785 AZ-3-C40
211786 AZ-4-C40
211787 AZ-3N-C40
211788
50 AZ-C50
211789 AZ-2-C50
211790 AZ-3-C50
211791 AZ-4-C50
211792 AZ-3N-C50
211793
63 AZ-C63
211794 AZ-2-C63
211795 AZ-3-C63
211796 AZ-4-C63
211797 AZ-3N-C63
211798
80 AZ-C80
211799 AZ-2-C80
211800 AZ-3-C80
211801 AZ-4-C80
211802 AZ-3N-C80
211803
100 AZ-C100
211804 AZ-2-C100
211805 AZ-3-C100
211806 AZ-4-C100
211807 AZ-3N-C100
211808
125 AZ-C125
211809 AZ-2-C125
211810 AZ-3-C125
211811 AZ-4-C125
211812 AZ-3N-C125
211813
Characteristic D
Instantaneous release
response current 10 …
20 x I
n
Switching
capacity 15 … 25 kA
(IEC/EN 60947-2)
50 AZ-D50
211814 12 off AZ-2-D50
211815 2 off AZ-3-D50
211816 1 off AZ-3N-D50
211817 1 off
63 AZ-D63
211818 AZ-2-D63
211819 AZ-3-D63
211820 AZ-3N-D63
211821
80 AZ-D80
211822 AZ-2-D80
211823 AZ-3-D80
211824 AZ-3N-D80
211825
100 AZ-D100
211826 AZ-2-D100
211827 AZ-3-D100
211828 AZ-3N-D100
211829
2
1
2
1
4
3
246
135
46
53
2
1
8
7
246
5
N
N31
For switching capacity refer to Technical
Data
Accessories
Auxiliary contacts, Volta-
ge releases a16/17
Mounting accessories a16/18
1 pole
Depth 75 mm
Width 27 mm
2 pole
Depth 75 mm
Width 54 mm
3 pole
Depth 75 mm
Width 81 mm
4-pole; 3N-pole
Depth 75 mm
Width 108 mm
16/11
AZ AZ
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/12
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Residual-current protective modules for FAZ and AZ
2 pole 4 pole
Rated
uninterrupted
current
Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Part no.
Article no. Price
see price
list
Std.
pack
Iu
A
Residual-current protective
modules for FAZ
Rated fault
current IDN = 30
mA
40 FIM-40/2/0,03-A
278510 1 off FIM-40/4/0,03-A
278514 1 off
63 FIM-63/2/0,03-A
278512 1 off FIM-63/4/0,03-A
278516 1 off
Rated fault
current IDN =
300 mA
40 FIM-40/2/0,3-A
278511 1 off FIM-40/4/0,3-A
278515 1 off
63 FIM-63/2/0,3-A
278513 1 off FIM-63/4/0,3-A
278517 1 off
2 pole 4 pole 4 pole
Selective
Rated
uninterrupted
current
Part no.
Article no. Price
see price
list
Std.
pack Part no.
Article no. Price
see price
list
Part no.
Article no. Price
see price
list
Std.
pack
Iu
A
Residual-current protective
modules for AZ
Rated fault
current IDN = 30
mA
80 AZFIMP-4-80-0,03
255484 1 off
125 AZFIMP-4-125-0,03
255488 1 off
Rated fault
current IDN =
300 mA
80 AZFIMP-2-80-0,3
255477 1 off AZFIMP-4-80-0,3
255485 AZFIMS-4-80-0,3
255492 1 off
125 AZFIMP-2-125-0,3
255481 1 off AZFIMP-4-125-0,3
255489 AZFIMS-4-125-0,3
255495 1 off
Notes FIM-.../2/... FIM-.../4/... AZFIMP-2-... AZFIMP-4-...
AZFIMS-4-...
2' 4'
24 H
T
2' 4' 6' 8'N
2468N H
T
1' 3'/N 13
2' 4'/N 14
H
T
1' 7'/N 13
2'
3'
4'
5'
6' 8'/N 14
H
T
FIM, AZFIMP, AZFIMS
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/13
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Combined RCD/MCB devices
2 pole 2 pole
Rated current Part no.
Article no. Price
see price list Part no.
Article no. Price
see price list Std. pack
In
ARated fault current IDN = 30 mA Rated fault current IDN = 300 mA
PKNM conbination switch, type A
Characteristic B
Switching capacity
10 kA
6PKNM-6/1N/B/003-A-DW
238580 PKNM-6/1N/B/03-A-DW
238582 1 off
10 PKNM-10/1N/B/003-A-DW
238640 PKNM-10/1N/B/03-A-DW
238642
13 PKNM-13/1N/B/003-A-DW
238701 PKNM-13/1N/B/03-A-DW
238703
16 PKNM-16/1N/B/003-A-DW
238773 PKNM-16/1N/B/03-A-DW
238775
20 PKNM-20/1N/B/003-A-DW
238807 PKNM-20/1N/B/03-A-DW
238809
25 PKNM-25/1N/B/003-A-DW
238837 PKNM-25/1N/B/03-A-DW
238839
32 PKNM-32/1N/B/003-A-DW
238867 PKNM-32/1N/B/03-A-DW
238869
40 PKNM-40/1N/B/003-A-DW
238896 PKNM-40/1N/B/03-A-DW
238898
Characteristic C
Switching capacity
10 kA
6PKNM-6/1N/C/003-A-DW
238590 PKNM-6/1N/C/03-A-DW
238592
10 PKNM-10/1N/C/003-A-DW
238650 PKNM-10/1N/C/03-A-DW
238652
13 PKNM-13/1N/C/003-A-DW
238713 PKNM-13/1N/C/03-A-DW
238715
16 PKNM-16/1N/C/003-A-DW
238785 PKNM-16/1N/C/03-A-DW
238787
20 PKNM-20/1N/C/003-A-DW
238817 PKNM-20/1N/C/03-A-DW
238819
25 PKNM-25/1N/C/003-A-DW
238847 PKNM-25/1N/C/03-A-DW
238849
32 PKNM-32/1N/C/003-A-DW
238877 PKNM-32/1N/C/03-A-DW
238879
40 PKNM-40/1N/C/003-A-DW
238906 PKNM-40/1N/C/03-A-DW
238908
N1
N2
H
N1
N2
H
PKNM
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/14
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Residual-current circuit-breakers
2 pole 4 pole
Rated
uninterrupted
current
Part no.
Article no. Price
see price list Std. pack Part no.
Article no. Price
see price list Std. pack
Iu
A
Residual current device F1, Type A
Rated fault current IDN = 30 mA 16 FI-16/2/003-A
279183 1 off
25 FI-25/2/003-A
279184 1 off FI-25/4/003-A
279213 1 off
40 FI-40/2/003-A
279187 1 off FI-40/4/003-A
279217
63 FI-63/4/003-A
279221
80 FI-80/4/003-A
279225
100 FI-100/4/003-A/-
102936
125 FI-125/4/003-A
279165
Rated fault current IDN = 100 mA 25 FI-25/2/01-A
279185 1 off FI-25/4/01-A
279214 1 off
40 FI-40/2/01-A
279188 1 off FI-40/4/01-A
279218
63 FI-63/4/01-A
279222
Rated fault current IDN = 300 mA 25 FI-25/2/03-A
279186 1 off FI-25/4/03-A
279215 1 off
40 FI-40/2/03-A
279189 1 off FI-40/4/03-A
279219
63 FI-63/4/03-A
279223
80 FI-80/4/03-A
279226
100 FI-100/4/03-A/-
102937
125 FI-125/4/03-A
279167
Rated fault current IDN = 500 mA 25 FI-25/4/05-A
279216 1 off
40 FI-40/4/05-A
279220
63 FI-63/4/05-A
279224
80 FI-80/4/05-A
279227
100 FI-100/4/05-A/-
102938
125 FI-125/4/05-A
279169
Notes F 100 A 125 A
N
N
T
H
2
1
N
N
462
135
T
H
7
8
351
246
T
H
FI...-A
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/15
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Residual-current circuit-breakers
4 pole
Rated
uninterrupted
current
Part no.
Article no. Price
see price list Std. pack Notes
Iu
A
Suitable for frequency inverters, type U
Rated fault current IDN = 100 mA 40 FI-40/4/01-U
279234 1 off
63 FI-63/4/01-U
279236
Rated fault current IDN = 300 mA 40 FI-40/4/03-U
279235
63 FI-63/4/03-U
279237
Selective and surge-proof 5 kA, type S/A
Rated fault current IDN = 100 mA 63 FI-63/4/01-S/A
279228 1 off
Rated fault current IDN = 300 mA 63 FI-63/4/03-S/A
279229
FI-80/4/03-S/A
279230
Sensitive to AC/DC, B type
Rated fault current IDN = 30 mA 40 FI-40/4/003-B
240710 1 off
For us in 50 Hz AC current systems with electrical equipment such
as frequency inverters, UPS systems of switched-mode power
supplies.
During a malfunction electrical equipment can cause AC fault
currents and pulsed DC fault currents as well as smooth pulsating
d.c. fault current, where RCCB's of type C will not trip. The residual
current devices FI-B detects all fault current types in accordance
with the tripping characteristic B of the IEC 60755, i.e. even
pulsating d.c. fault current
Caution: In some countries the insurance companies place
special demands on RCCS's.
Contact position display red-green
Position independent function
Trip occurs independent of the mains voltage (currents type AC
and A)
30 V AC necessary for detection of type B current
Mains connection side top
Type S/B 40 ms delay and selective switch off
Auxiliary contacts on request
63 FI-63/4/003-B
240711
80 FI-80/4/003-B
240712
1251) FI-125/4/003-B
240717
Rated fault current IDN = 100 mA 40 FI-40/4/01-B
279170
63 FI-63/4/01-B
279171
80 FI-80/4/01-B
279172
1251) FI-125/4/01-B
240722
Rated fault current IDN = 300 mA 40 FI-40/4/03-B
279173
63 FI-63/4/03-B
279174
80 FI-80/4/03-B
279175
1251) FI-125/4/03-B
240727
AC/DC, selective, B type
Rated fault current IDN = 300 mA 40 FI-40/4/03-S/B
281022 1 off
63 FI-63/4/03-S/B
281023
80 FI-80/4/03-S/B
281024
Notes 1) Neutral pole right, at 125 A neutral pole on left
N
N
462
135
T
H
N
N
462
135
T
H
I >
7
8
1
2
5
6
3
4
T
FI...-U, FI...-S/A, FI...-B
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/16
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Residual current devices FI for export
2 pole 4 pole 4 pole
Selective and surge-proof 5
kA
Rated
uninterrupted
current
Part no.
Article no. Price
see price list Std. pack Part no.
Article no. Price
see price list Std. pack Part no.
Article no. Price
see price list Std. pack
Iu
A
FI residual-current circuit-breakers,
only for export (AC type)
Rated fault current IDN
= 30 mA 16 FI-16/2/003
279176 1 off
25 FI-25/2/003
279177 FI-25/4/003
279196 1 off
40 FI-40/2/003
279180 FI-40/4/003
279200
63 FI-63/2/003
279190 FI-63/4/003
279204
80 FI-80/2/003
279192 FI-80/4/003
279208
Rated fault current IDN
= 100 mA 25 FI-25/2/01
279178 1 off FI-25/4/01
279197 1 off
40 FI-40/2/01
279181 FI-40/4/01
279201
63 FI-63/2/01
279191 FI-63/4/01
279205 FI-63/4/01-S
279210 1 off
80 FI-80/2/01
279193 FI-80/4/01
279231
Rated fault current IDN
= 300 mA 25 FI-25/2/03
279179 1 off FI-25/4/03
279198 1 off
40 FI-40/2/03
279182 1 off FI-40/4/03
279202
63 FI-63/4/03
279206 FI-63/4/03-S
279211 1 off
80 FI-80/4/03
279209 FI-80/4/03-S
279212 1 off
Rated fault current IDN
= 500 mA 25 FI-25/4/05
279199
40 FI-40/4/05
279203
63 FI-63/4/05
279207
Notes
N
N
T
H
2
1
N
N
462
135
T
H
FI
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/17
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Auxiliary contacts, voltage releases, MCB lock
Contacts Contact
sequence Space units 1 SU
= 18 mm Part no.
Article no. Price
see price list Std. pack
Number SU
Auxiliary contacts and voltage releases
Auxiliary contacts for FAZ, AZ, PKNM
FAZ
PKNM Up to 63 A 1 N/O/1 N/C 0.5 FAZ-XHIN11
286054 10 off
1 C/O 0.5 FAZ-XHINW1
286055 10 off
AZ Up to 125 A 1 N/O/1 N/C 0.5 AZ-XHI11
212067 10 off
Trip-indicating auxiliary contact for FAZ, PKNM1)
FAZ
PKNM Up to 63 A 2 C/O 0.5 FAZ-XAM002
262414 10 off
Auxiliary contact for FI
FI Up to 100 A 1 N/O/1 N/C 0.5 FIP-XHI11
225121 10 off
FI2) From 125 A and
Type B 1 N/O/1 N/C 0.5 FIPA-XAM011
262578 10 off
Shunt releases for FAZ, AZ, PKNM
FAZ
PKNM Up to 63 A 1 FAZ-XAA-C-12-110VAC
278518 10 off
FAZ
PKNM Up to 63 A 1 FAZ-XAA-C-110-415VAC
278519 10 off
AZ Up to 125 A 1.5 AZ-XAA(110-415VAC)
212059 10 off
AZ Up to 125 A 1.5 AZ-XAA(12-60VAC)
212061 10 off
Undervoltage releases for FAZ
FAZ 1 FAZ-XUA(115VAC)
212049 10 off
FAZ 1 FAZ-XUA(230VAC)
212051 10 off
FAZ 1 FAZ-XUA(400VAC)
212053 10 off
Lockout
device for
FAZ/FIP
IS/SPE-1TE
101911 10 off
Notes 1) The device is supplied with the groove in the yellow selector button in the horizontal: Changeover contact 4.11 … 4.12/4.14
switches when tripped manually or electrically. Turning the yellow selector button by 90° results in contact 4.11 … 4.12/4.14
responding only to electrical tripping: the contact 4.11 … 4.12/4.14 remains closed when tripped by hand.
2) The device is supplied with the “Auxiliary contact” function set such that both contacts switch on manual and electrical tripping. A
change of function to “Signalling switch” means that both contacts switch only under fault conditions.
AC-11, 230 V DC/6 A
DC-11, 230 V DC/1 A
Minimum voltage: 12 V AC/DC
Minimum current: 100 mA
Terminal capacity: 1 x 2.5 mm2, 2 x 1.5 mm2
Max. tightening torque: 0.8 Nm
14 22
2113
12 14
11
1.13 1.21
1.14 1.22
1.14 4.141.12
1.11
4.12
4.11
1.13 1.21
1.14 1.22
1.141.12
1.11
1.21
1.22
C2
C1
C2
C1
C2
C1
C2
C1
D2
U
D1
FAZ-X, AZ-X, FIP-X
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/18
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Busbars
Phases Devices Part no.
Article no. Price
see price list Std. pack Notes
Number Number
Euro-Vario busbars (fork connector)
For FAZ…, FI…
16 mm2
No end covers required
do not shorten
12EVG-16/1PHAS/2MODUL
291464 40 off
16EVG-16/1PHAS/6MODUL
291465
112EVG-16/1PHAS/12MODUL
291466
24EVG-16/2PHAS/4MODUL
291467
26EVG-16/2PHAS/6MODUL
291468
212EVG-16/2PHAS/12MODUL
291469
36EVG-16/3PHAS/6MODUL
291470
39EVG-16/3PHAS/9MODUL
291471
312EVG-16/3PHAS/12MODUL
291472
316EVG-16/3PHAS/16MODUL
291473
320EVG-16/3PHAS/20MODUL
291474
48EVG-16/4PHAS/8MODUL
291475
412EVG-16/4PHAS/12MODUL
291476
For combined use of 4 pole residual-current-operated circuit-breakers with
circuit-breakers
34 + 5EVG-16/3PHAS/N/5MODUL/LS
291477
34 + 8EVG-16/3PHAS/N/8MODUL/LS
291478
For use with auxiliary contacts
12EVG-16/1PHAS/2MODUL/HI
291479
16EVG-16/1PHAS/6MODUL/HI
291480
19EVG-16/1PHAS/9MODUL/HI
291481
22EVG-16/2PHAS/4MODUL/HI
291482
23EVG-16/2PHAS/6MODUL/HI
291483
25EVG-16/2PHAS/10MODUL/HI
291484
32EVG-16/3PHAS/6MODUL/HI
291485
34EVG-16/3PHAS/12MODUL/HI
291486
3 x 16 EVG-16/3X1PHAS/6MODUL/HI
291487
3 x 18 EVG-16/3X1PHAS/8MODUL/HI
291488
3 x 19 EVG-16/3X1PHAS/9MODUL/HI
291489
LL
17.8
LNLNLN
L1 L2 L3 L1 L2 L3
L1 L2 L3 N L1 L2 L3 N
L1 L2 L3 L1 L2 L1 L2L3
L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2
26.8
LL
LN LN
27
L1 L2 L3 L1 L2 L3
L1 L2 L3
EVG-16
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/19
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Mounting accessories
Rated
operational
current
No. of
poles Cross-section Length Part no.
Article no. Price
see price list Std. pack
Ie
Amm
2m
Mounting accessories
1-phase, 80 A 80 1 16 1 Z-GV-16/1P-1TE
271061 50 off
3-phase, 63 A 63 3 10 1 Z-GV-10/3P-3TE
271060 20 off
End caps for Z-GV-10/3P-3ST 3 10 Z-AK-10/2+3P
271069 10 off
80 3 16 1 Z-GV-16/3P-3TE
271064 20 off
–316
Z-AK-16/2+3P
271070 10 off
80 4 16 1 Z-GV-16/3P+N-4TE
271066 15 off
–416
Z-AK-16/4P
271071 10 off
Feeder block
With end feeder max. 80 A
with center feeder max. 125 A ––1 x 25
1 x 50 FAZ/FIP-XVS-KL
212109 12 off
Incoming terminals
4,3 Nm, touch-proof busbar connection to miniature
circuit-breaker ––25FAZ-XK25
212116 50 off
M5: 3.0 Nm, M8: 4.3 Nm Touch-proof connection to
FAZ-XIS... busbar ––35
FAZ-XK35
212119 10 off
Protective covers
For shrouding unused terminals on the busbar ZV-BS-G
104903 1 off
Bracket for securing the covers 2 off required per group of
MCB's ––
REG-BB
212106 20 off
Rated operational
current Length Part no.
Article no. Price
see price list Std. pack
Ie
Am
Extension terminals, 80 A
Same extension terminal, turned by 180°
L1, N 80 ZV-L1/N-80A-10
263950 10 off
L1, N 80 ZV-L1/N-80A-36
263951 36 off
L1, N 80 ZV-L1/N-80A-100
263952 100 off
L2, L3 80 ZV-L2/L3-80A-10
263953 10 off
L2, L3 80 ZV-L2/L3-80A-36
263954 36 off
L2, L3 80 ZV-L2/L3-80A-100
263955 100 off
Busbars
1m long.
50 1 ZV-SS
263956 10 off
80 1 ZV-SS-80A
263957 10 off
Shroud section
1m long, for 50 and 80 A.
––ZV-ADP
263958 100 off
End cap for shroud
––ZV-AEK
263959 10 off
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/20
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Remote switching modules, fuse bases
Part no.
Article no. Price
see price list Std. pack
Remote switching modules
IEC/EN 60669-2-2
For remote switching and automatic miniature circuit-breakers FAZ and residual current devices FI up to 80 A
with the exception ot type B
Mechanically lockable and sealable
Operating and alarm display via LED
Mechanical switching capability up to FAZ-…63 or FI-80… with the exception of type B (-XFSM)
…25 °C/+40 °C
Rated operational voltage 24 … 240 V AC, 24 … 48 V DC
Terminal capacity 2 x 1.5 mmB, 1 x 2.5 mmB; 0.4 Nm
Mechanical/electrical live 10,000 switching operations
Power consumption 5 W
220 … 240 V AC FAZ/FIP-XAWM
262514 1 off
48 V DC FAZ/FIP-XDWM
274404 1 off
Remote test module
External test module with test resistor for RCCB devices
Version adapted for rated fault currents with stipulated “external” test button function
0.01 A Z-FW/001
248297 4 off
0.03 A Z-FW/003
248298 4 off
0.1 A Z-FW/010
248299 4 off
0.3 A Z-FW/030
248300 4 off
0.5 A Z-FW/050
248301 4 off
Pole Rated
operational
current
Rated
operational
voltage
Fuse
cartridge Part no.
Article no. Price
see price
list
Std. pack Notes
IeUe
AV ACSize
Fuse base
1 pole 16 D01 D01-SO/16/1
102752 1 off Equipment supplied:
Empty, without
screw on cover
1 pole 63 D02 D02-SO/63/1
102675 1 off
3 pole 16 D01 D01-SO/16/3
102674 1 off
3 pole 63 D02 D02-SO/63/3
102676 1 off
FAZ-FIP, Z-FW, D0…-SO
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/21
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Ordering
Mounting accessories
For use with Terminal
capacity for
round
conductor
Part no.
Article no. Price
see price
list
Std. pack Notes
mm2
Covers for 1-pole fuse bases
Standard dimension 45 mm
S...-1/... P-E14
086182 20 off
S...-1/... P-E18
088555 20 off
S...-1/... P-E27
090928 10 off
S...-1/... P-E33
093301 10 off
Transparent shroud
With cable entry knockouts top and bottom H-S27-1
029118 10 off
Busbar connector 63 A
For fuse bases, 3 pole D0.../3 Z-SV-16/3P
271072 20 off
Cover
For busbar block Z-SV-16/3P Z-AK-16/2+3P
271070 10 off
Notched phase busbars, can be cut to length
For gauge ring (gauge screw: /FORMP)
990 mm long, for max. 36 fuse bases, rated current 100 A
S14-1/C KS14
050502 5 off
990 mm long, for max. 36 fuse bases, rated current 160 A
S18-1/C KS18
052875 5 off
980 mm long, for max. 22 fuse bases, rated current 100 A
S27-1/C KS27
055248 5 off
960 mm long, for max. 18 fuse bases, rated current 160 A
S33-1/C KS33
059994 5 off
Terminals
For gauge ring (gauge screw: /FORMP)
For round conductors up to 35 mm2 or flat conductors 6 x 9 x 0.8
KS14 – KS33 K35-AB
064339 20 off
For retrofitting as PE/N terminal
S27/1 a 1.5 – 6 K6/1
002270 100 off Terminal capacity
a solid
s stranded
q flexible with
ferrule
S33/1 a 4 … 16
s 4 … 16
q 4 … 10
K16/1
002272 25 off
Dimensions (W x H x D) Rated operational
current Cu factor Part no.
Article no. Price
see price
list
Std. pack
Ie
mm A
Busbars
Flat copper busbars, tinned
12 x 5 Supplied in lengths of 1500 mm 160 0,81 CU12X5
034121 10 off
20 x 5 Supplied in lengths of 1500 mm 250 1,34 CU20X5
044092 10 off
20 x 10 Supplied in lengths of 1500 mm 400 2,68 CU20X10
041719 5 off
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/22
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Busbar mounting switch-disconnector
Fuse cartridge Rated uninterrupted
current Part no.
Article no. Price
see price
list
Std. pack
Iu
Size A
Busbar mounting switch-disconnector
With fuses D02-S/63/3-RS for 60 mm distance
between busbar centres
3 pole, 36 mm
Supplied empty and without screw on cover
D02 max. 63 D02-S/63/3-RS
284649 1 off
Fuses, utilisation class gG (gL)
Snap-fit on DIN rail
in a plastic box in the colour of the indicator
D01 2 Z-D01/SE-2
288934 12 off
4Z-D01/SE-4
288935 12 off
6Z-D01/SE-6
288936 12 off
10 Z-D01/SE-10
288937 12 off
13 Z-D01/SE-13
288938 12 off
16 Z-D01/SE-16
288939 12 off
D02 20 Z-D02/SE-20
288940 12 off
25 Z-D02/SE-25
288941 12 off
32 Z-D02/SE-32
288942 12 off
35 Z-D02/SE-35
288943 12 off
40 Z-D02/SE-40
288944 12 off
50 Z-D02/SE-50
288945 12 off
63 Z-D02/SE-63
288946 12 off
Gauge ring
D01 for fuse base D02 and fuse switch-
disconnector D02
Snap-fit on DIN rail
in a plastic box in the colour of the indicator
D01 2 Z-D01/PE-2
288909 12 off
4Z-D01/PE-4
288910 12 off
6Z-D01/PE-6
288911 12 off
10, 13 Z-D01/PE-10
288912 12 off
D02 20 Z-D02/PE-20
288913 12 off
25 Z-D02/PE-25
288914 12 off
35, 32 Z-D02/PE-35
288915 12 off
40 Z-D02/PE-40
288916 12 off
50 Z-D02/PE-50
288917 12 off
D01 for fuse base D02 and fuse switch-
disconnector D02
Snap-fit on DIN rail
in a plastic box in the colour of the indicator
D02-D01 2 Z-D02-D01/PE-2
263112 12 off
4Z-D02-D01/PE-4
263113 12 off
6Z-D02-D01/PE-6
263150 12 off
10, 13 Z-D02-D01/PE-10
263151 12 off
16 Z-D02-D01/PE-16
263152 12 off
Screw cap D01 max. 16 Z-D01/SK
100650 1 off
D02 max. 63 Z-D02/SK
100651 1 off
Spring
For inserting D01 fues links in the screw cap Z-
D02/SK
D02-D01 Z-D02/SIKA-HF
263149 50 off
D02, Z-D0...
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/23
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Fuse switch-disconnector, fuse sets
Pole Rated uninterrupted
current Fuse cartridge Part no.
Article no. Price
see price list Std. pack
Iu
ASize
fuse switch-disconnector
Standard, empty 1 max. 63 D02, D01 Z-SLS/NEOZ/1
248235 12 off
1 + N Z-SLS/NEOZ/1+N
248237 6 off
2 Z-SLS/NEOZ/2
248233 6 off
3 Z-SLS/NEOZ/3
248234 4 off
3 + N Z-SLS/NEOZ/3+N
248236 3 off
With fuse monitoring, empty 1 + HS Z-SLK/NEOZ/1
248238 6 off
1 + N + HS Z-SLK/NEOZ/1+N
248242 4 off
2 + HS Z-SLK/NEOZ/2
248239 4 off
3 + HS Z-SLK/NEOZ/3
248240 3 off
3 + N + HS Z-SLK/NEOZ/3+N
248241 2 off
Security sets
For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK
With flashing function
Snap-fit on DIN rail
1 set consists of: 3 fuse links, 3 current codings, 1 plastic box in the colour of the indicator
Rated operational voltage 24 V AC/
DC 1Z-SLS/B-24-1A
268994 12 off
2Z-SLS/B-24-2A
268995 12 off
4Z-SLS/B-24-4A
268996 12 off
6Z-SLS/B/24-6A
268997 12 off
10 Z-SLS/B/24-10A
268998 12 off
13 Z-SLS/B/24-13A
289975 12 off
16 Z-SLS/B/24-16A
268999 12 off
20 Z-SLS/B/24-20A
269000 12 off
25 Z-SLS/B/24-25A
269001 12 off
32 Z-SLS/B/24-32A
289976 12 off
35 Z-SLS/B/24-35A
269002 12 off
40 Z-SLS/B/24-40A
289977 12 off
50 Z-SLS/B/24-50A
269003 12 off
63 Z-SLS/B/24-63A
269004 12 off
Z-SLS, Z-SLK
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/24
http://catalog.moeller.net
Miniature circuit-breakers
Ordering
Fuse sets
Rated uninterrupted
current Fuse cartridge Part no.
Article no. Price
see price list Std. pack
Iu
ASize
Fuse sets
Rated operational voltage 60 … 400 V
AC 1Z-SLS/B-1A
268983 12 off
2Z-SLS/B-2A
268984 12 off
4Z-SLS/B-4A
268985 12 off
6Z-SLS/B-6A
268986 12 off
10 Z-SLS/B-10A
268987 12 off
13 Z-SLS/B-13A
289972 12 off
16 Z-SLS/B-16A
268988 12 off
20 Z-SLS/B-20A
268989 12 off
25 Z-SLS/B-25A
268990 12 off
32 Z-SLS/B-32A
289973 12 off
35 Z-SLS/B-35A
268991 12 off
40 Z-SLS/B-40A
289974 12 off
50 Z-SLS/B-50A
268992 12 off
63 Z-SLS/B-63A
268993 12 off
Dissconnector kit
For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK
Snap-fit on DIN rail
1 set consists of: 3 switch conversion sets, 3 current codings, 1 plastic box
The fuse switch-disconnector is thus converted to a switch-disconnector.
63 Z-SLS/TR-SET
100660 1 off
Switch-on inhibits
For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK
Only 1 stop required per device
Stop with metal lock Z-SLZ/SC
268980 12 off
Stop with plastic lock Z-SLZ/SP
268981 12 off
Incoming double terminal
For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK
•2 x 3 x 35 mm2
Z-SLZ/KL
268982 15 off
Z-SLS, Z-SLZ
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/25
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Fuse switch-disconnector
Pole Part no.
Article no. Price
see price list Std. pack
Fuse switch-disconnectors, empty
For cylindrical fuses
Size 14 x 51, up to 50 A
Without flashing function 1 VLC14-1P
285361 12 off
1 + N VLC14-1P+N
285362 12 off
2VLC14-2P
285363 12 off
3VLC14-3P
285364 12 off
3 + N VLC14-3P+N
285365 12 off
With flashing function 1 VLC14-1P/L
285371 12 off
1 + N VLC14-1P+N/L
285372 12 off
2VLC14-2P/L
285373 12 off
3VLC14-3P/L
285374 12 off
3 + N VLC14-3P+N/L
285375 12 off
Size 22 x 58, up to 100 A
Without flashing function 1 VLC22-1P
285366 12 off
1 + N VLC22-1P+N
285367 12 off
2VLC22-2P
285368 12 off
3VLC22-3P
285369 12 off
3 + N VLC22-3P+N
285370 12 off
With flashing function 1 VLC22-1P/L
285376 12 off
1 + N VLC22-1P+N/L
285377 12 off
2VLC22-2P/L
285378 12 off
3VLC22-3P/L
285379 12 off
3 + N VLC22-3P+N/L
285380 12 off
VLC
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/26
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
LV h.b.c. fuse bases, LV h.b.c. fuse switch-disconnectors
Interval
between
busbar
centres
Busbar
size Rated
operational
current
Max. fuse Part no.
Article no. Price
see price list Std. pack
Ie500 V 690 V Size
mm mm A A A
Low-voltage h.b.c. fuse bases
3-pole
160 160 100 NH00 GS00-160
026741 1 off
250 250 200 NH1 GSU1
289016 1 off
400 400 315 NH2 GSU2
289017 1 off
630 630 500 NH3 GSU3
289018 1 off
Lowvoltage h.b.c. fuse switchdisconnectors
for fitting to mounting plate, MR25
1 pole
Without hand
guard
160 160 100 NH00 GSTA00-160-1P1)
225000 1 off
3 pole
Without hand
guard
160 160 100 NH00 GSTA00-160
095558 1 off
250 250 200 NH1 GSTA1
017250 1 off
400 400 315 NH2 GSTA2
021996 1 off
630 630 500 NH3 GSTA3
026742 1 off
For mounting on busbars, flat busbars
3 pole
Without hand
guard
3-pole
60 12 … 30
x 5 … 10 100 100 NH000 LTS-100/C00/3-R
284690 1 off
Without hand
guard
Connection
top and
bottom
40/50/60 12 … 30
x 5 … 10 160 160 100 NH00 GST00-160-40-60-AOU
224550 1 off
For mounting on busbars
3 pole
With hand guard
Connection at
bottom 60 20 … 30
x 5 … 10 250 250 200 NH1 GST1-AU
107251 1 off
400 400 315 NH2 GST2-AU
107253 1 off
630 630 500 NH3 GST3-AU
107255 1 off
Connection at
top 250 250 200 NH1 GST1-AO
107250 1 off
400 400 315 NH2 GST2-AO
107252 1 off
630 630 500 NH3 GST3-AO
107254 1 off
Notes 1) Can be fitted to GSTA00-160 for 4-pole low-voltage h.b.c. fuse switch-disconnector
Two devices can be combined to make a 2-pole low-voltage h.b.c. fuse switch-disconnector
GS…, GST…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/27
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
NH fuse mounting accessories
For use with Part no.
Article no. Price
see price list Std. pack
Clip set
Can be retrofitted, adjustable
For latching on to two top-hat rails to IEC/EN 60715 (35 mm)
For distances of 100 to 125 mm between busbar centres
GSTA00-160 C-GSTA00
040922 5 off
Sets of clamp-type terminals
One set comprises 3 clamptype terminals
Terminal range 1 x (70 150) mmB Cu/Al GSU1, GST...1 PSK1
038734 1 off
Terminal range 1 70 150) mmB Cu/Al GSU2, GST...2 PSK2
043480 1 off
Terminal range 1 x (120 300) mmB Cu/Al GSU3, GST...3 PSK3
048226 1 off
Sets of double clamp-type terminals
One set comprises of 3 double clamptype terminals.
Terminal range 2 x (70 95) mmB Cu/Al GSU1, GST...1 PSK12
041107 1 off
Terminal range 2 x (120 150) mmB Cu/Al GSU2, GST...2 PSK22
045853 1 off
Terminal range 2 x (120 240) mmB Cu/Al GSU3, GST...3 PSK32
050599 1 off
Hand guard for fuse switch-disconnectors
Provides additional protection for the operator during actuation of the fuse-switch disconnector
GST00...
GSTA00... ZBS-GSTA00
014411 10 off
GSTA1 ZBS-GSTA1
082800 10 off
GSTA2 ZBS-GSTA2
082801 5 off
GSTA3 ZBS-GSTA3
082802 1 off
Insulating surround for fuse switch-disconnectors
For compensation between the GA… protective cover and the device
(for use in the CI insulated distribution board system)
GST00 B-GST00-40-60/CI/1
224553 5 off
C-GST, PSK, ZBS
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/28
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
Low-voltage h.b.c. switch-fuse units
Rated operational current Fuse cartridge Part no.
Article no. Price
see price list Std. pack
Ie
ASize
Low-voltage h.b.c. switch-fuse units NH-SLS, 3 pole
With connection area cover
Mounting without holes with spike type terminal
Equipment supplied
NH-SLS-00/160(-SI): with spike-type terminal and clamp terminal
NH-SLS-00/160-60(-SI): with clamp terminal
NH-SLS Größen 1, 2, 3: without spike-type terminal, without clamp terminal
Busbar mounting
For size 00:
NH-SLS-00/160(-SI) clearance 100 mm, mounting without holes or screw mounting
NH-SLS-00/160-60(-SI) clearance 60 mm, mounting without holes
Sizes 1, 2, 3: clearance 185 mm, mounting without holes or screw mounting
Without fuse monitoring 160 00 NH-SLS-00/160
106210 0 off
160 00 NH-SLS-00/160-60
106211
250 1 NH-SLS-1/250
106212
400 2 NH-SLS-2/400
106213
630 3 NH-SLS-3/630
106214
With fuse monitoring 160 00 NH-SLS-00/160-SI
106215
160 00 NH-SLS-00/160-60-SI
106216
250 1 NH-SLS-1/250-SI
106217
400 2 NH-SLS-2/400-SI
106218
630 3 NH-SLS-3/630-SI
106219
Part no.
Article no. Price
see price list Std. pack
Adapter
Single adapter 100/185 Z-NH-SLS-00-SAD
106220 0 off
Double adapter 100/185 Z-NH-SLS-00-SADD
106221
Single adapter 100/185 for mounting without holes Z-NH-SLS-00-SAD-KR
106222
Terminal shroud/size adapter to NH-SLS
For NH-SLS-00/160
Z-NH-SLS-KA
106223 0 off
Claw-terminal
For connection at bottom Z-NH-SLS-KRU
106224 0 off
For connection at top Z-NH-SLS-KRO
106225
V terminals
Up to 240 mm2 for stranded sector conductor, up to 300 mm2 for solid sector conductor
For size 1, 2 Z-NH-SLS-1+2-VAK
106226 0 off
For size 3 Z-NH-SLS-3-VAK
106227
NH-SLS, Z-NH
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/29
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Ordering
NH fuse mounting accessories
Transformer ratio Part no.
Article no. Price
see price list Std. pack
K
N
A
Termination expansion for 2 cable lugs
For size 1, 2 Z-NH-SLS-1+2-AE
106239 0 off
For size 3 Z-NH-SLS-3-AE
106240
Device carrier with DIN rail for terminals etc.
Cover Z-NH-SLS-1+2+3-GTAB
106231 0 off
Lower section Z-NH-SLS-1+2+3-GT
106230
Current transformer
NH-SLS-00
Fix on Z-NH-SLS-00-SAD… with fixing clip Z-NH-SLS-00BC.
NH-SLS size 1, 2, 3
Swing into the standard rail, no additional space requirement.
Mounting of spike type terminal still possible
Fix current transformer cables with fixing clip Z-NH-SLS-1+2+3-BC.
150/5 Z-WAS-150/5A-1
106232 0 off
200/5 Z-WAS-200/5A-1
106233
250/5 Z-WAS-250/5A-1
106234
300/5 Z-WAS-300/5A-1
106235
400/5 Z-WAS-400/5A-1
106236
500/5 Z-WAS-500/5A-1
106237
600/5 Z-WAS-600/5A-1
106238
Fixing clip
Fixing for current transformer on the busbar adapter in
185 mm busbar system (size 00) Z-NH-SLS-00-BC
106229 0 off
Fixing of the (current transformer) cables to the rear of
the NH rails for sizes 1, 2, 3 Z-NH-SLS-1+2+3-BC
106228 0 off
Z-NH, Z-WAS
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/30
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Engineering
Miniature circuit-breakers, tripping characteristic
Influence of the ambient temperature on the thermal trip behaviour Load carrying capacity with side-by-side miniature circuit-breakers
Corrected values of the rated current dependent on the ambient temperature
Ambient temperature T [°C]
In [A] –25 –20 –10 0 10 20 30 35 40 45 50 55 60
0.16 0.20 0.19 0.19 0.18 0.17 0.17 0.16 0.16 0.15 0.15 0.15 0.14 0.14
0.25 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.25 0.24 0.24 0.23 0.23 0.22
0.5 0.61 0.60 0.58 0.56 0.54 0.52 0.50 0.49 0.48 0.47 0.46 0.45 0.44
0.75 0.92 0.90 0.87 0.84 0.81 0.78 0.75 0.74 0.73 0.71 0.69 0.68 0.66
11.2 1.2 1.2 1.1 1.1 1.0 1.0 0.99 0.97 0.95 0.93 0.90 0.89
1.5 1.8 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.5 1.4 1.4 1.4 1.3
1.6 2.0 1.9 1.9 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.5 1.4 1.4
22.4 2.4 2.3 2.2 2.2 2.1 2.0 2.0 1.9 1.9 1.9 1.8 1.8
2.5 3.1 3.0 2.9 2.8 2.7 2.6 2.5 2.5 2.4 2.4 2.3 2.3 2.2
33.7 3.6 3.5 3.4 3.3 3.1 3.0 3.0 2.9 2.8 2.8 2.7 2.7
3.5 4.3 4.2 4.1 3.9 3.8 3.7 3.5 3.4 3.4 3.3 3.2 3.2 3.1
44.9 4.8 4.7 4.5 4.3 4.2 4.0 3.9 3.9 3.8 3.7 3.6 3.5 Influence of the mains frequency
Influence of the mains frequency on the tripping behaviour IMA of the instantaneous
release
56.1 6.0 5.8 5.6 5.4 5.2 5.0 4.9 4.8 4.7 4.6 4.5 4.4
67.3 7.2 7.0 6.7 6.5 6.3 6.0 5.9 5.8 5.7 5.6 5.4 5.3
89.8 9.6 9.3 9.0 8.7 8.4 8.0 7.9 7.7 7.6 7.4 7.2 7.1
10 12 12 12 11 11 10 10 9.9 9.7 9.5 9.3 9.0 8.9 Mains frequency f [Hz]
12 15 14 14 13 13 13 12 12 12 11 11 11 11 16N50 60 100 200 300 400
13 16 16 15 15 14 14 13 13 13 12 12 12 12 IMA(f)/IMA (50 Hz) [%] 91 100 101 106 115 134 141
15 18 18 17 17 16 16 15 15 15 14 14 14 13
16 20 19 19 18 17 17 16 16 15 15 15 14 14
20 24 24 23 22 22 21 20 20 19 19 19 18 18
25 31 30 29 28 27 26 25 25 24 24 23 23 22
32 39 38 37 36 35 33 32 32 31 30 30 29 28
40 49 48 47 45 43 42 40 39 39 38 37 36 35
50 61 60 58 56 54 52 50 49 48 47 46 45 44
63 77 76 73 71 68 66 63 62 61 60 58 57 56
Residual-current circuit-breakers
FI-…-B
Frequency response of the tripping current
30 mA
100 mA 300 mA
Number of circuit-breakers
12 34
0.70 0.80 0.90 1.00
5678
Rated diversity factor
1011
10
100
1000
10000
100 1000 10000 100000 1000000
30 mA
[mA]
[Hz]
Fault current
Frequency
1011
10
100
1000
10000
100 1000 10000 100000 1000000
100 mA
[mA]
[Hz]
Fault current
Frequency
1011
10
100
1000
10000
100 1000 10000 100000 1000000
300 mA
[mA]
[Hz]
Fault current
Frequency
FAZ, FI
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/31
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Engineering
Tripping characteristic for miniature circuit-breakers
Miniature circuit-breakers Miniature circuit-breakers
FAZ... AZ...
Tripping characteristic at 30 °C:
B, C, D to IEC/EN 60898 Tripping characteristic at 30°C:
C, D according to IEC/EN 60898
Combined RCD/MCB devices
PKNM-...
Tripping characteristic at 30°C:
B, C according to IEC/EN 61009
0.0005123456789101520304050
0.001
0.002
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10
t [s]
30
60
120
300
600
1200
3600
7200
1.13
1.45
BC D
1
2
5
b
g
a
a
c
d
e
f
X rated current
Specified non-tripping current
I
nt
= 1.13 X I
n
for t > 1 h
Specified tripping current
I
t
= 1.45 X I
n
for t < 1 h
a 2.55 X I
n
: t = 1 – 60 s (I
n
< 32 A)
t = 1 – 120 s (I
n
> 32 A)
b Type B: 3 X I
n
: t > 0.1 s
c Type B: 5 X I
n
: t < 0.1 s
d Type C: 5 X I
n
: t > 0.1 s
e Type C: 10 X I
n
: t < 0.1 s
f Type D: 10 X I
n
: t > 0.1 s
g Type D: 20 X I
n
: t < 0.1 s
0.0005
12345678910 15 20 30 40 50
0.001
0.002
0.005
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
t
[s]
30
60
DC
120
300
600
1200
3600
1.13
1.45
7200 Specified
non-tripping current
nt
= 1.13
n
for t > 1 h
Specified
tripping current
t
= 1.45
n
for t < 1 h
I
I
I
I
rated current
0.000512345678910
BC
15 20 30 40 50
0.001
0.002
0.005
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
t
[s]
30
60
120
300
600
1200
3600
7200
1.13
1.45
Specified
non-tripping current
nt
= 1.13
n
for t > 1 h
Specified
tripping current
t
= 1.45
n
for t < 1 h
I
I
I
I
rated current
FAZ, AZ, PKNM
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/32
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Engineering
Let-through characteristics
Miniature circuit-breakers
FAZ...
Let-through energy J
According to IEC/EN 60898 Let-through current xD
According to IEC/EN 60898
2 A
1 A
0.5 A
10 A
13 A
16 A
20 A
25 A
32 A
40 A
50 A
63 A
4 A
3 A
6 A
0.5
1.5 1512345678910
10
3
10
4
10
5
8
6
4
2
1.5
8
6
4
2
8
6
4
3
1.5
2
.
2
i dt
[A s]
FAZ-B
FAZ-C
FAZ-...-B4HI
Icc rms [kA]
1 A
2 A
3 A
10 A
13 A
16 A
20 A
25 A32 A
40 A50 A
63 A
4 A
6 A
0.5 1.5 1512345678910
103
104
[A]
1.5
2
3
4
5
6
7
8
9
2
5
FAZ-B
FAZ-C
Î
D
0.5 A
Icc rms [kA]
10 A
13 A
16 A
20 A
25 A
32 A
40 A
6 A
0.5 1.5 1512345678910
10
4
10
5
8
6
4
2
1.5
8
6
4
2
1.5
8
6
4
10
3
2
.
2
i dt
[A s]
FAZ-D
Icc rms [kA]
10 A
13 A
16 A
20 A
25 A
32 A
40 A
6 A
10
3
1.5
2
3
4
5
6
7
8
9
5
10
4
D
[A]
Î
FAZ-D
0.5 1.5 151234
5678910
2
Icc rms [kA]
FAZ
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/33
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Engineering
Let-through characteristics
Miniature circuit-breakers
AZ...
Let-through energy JLet-through current xD
105
AZ-C
1.5
8
6
4
3
2
1.5
8
6
4
3
2
1.5
104
103
50.5 1 1.5 2 3 4 6 7 8 9 10 15 25205
125 A 100 A
80 A 63 A
40 A
50 A
32 A
20 A
i2 dt
[A2s]
25 A
1
st
half-wave t = 10 ms
cc rms [kA]
I
125 A100 A 50 A
63 A
80 A
40 A
32 A
25 A
20 A
0.5 1.5 151 2 20 25345678910
103
104
Î
D
[A]
8
6
4
3
2
5
1.5
AZ-C
Icc rms [kA]
10
5
1.5
10
4
10
3
50.5 1 1.5 2 3 4 6 7 8 9 10 15 25205
100 A 80 A 63 A
50 A
∫ i
2
dt
[As]
8
6
4
3
2
1.5
8
6
4
3
2
1.5
AZ-D
1
st
half-wave t = 10 ms
cc rms
[kA]
I
0.5 1.5 151 2 20 25
100 A
80 A 50 A
63 A
345678910
10
3
10
4
I
D
[A]
8
6
4
3
2
5
1.5
AZ-D
cc rms
[kA]
I
AZ
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/34
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Engineering
Let-through characteristics
Combined RCD/MCB devices
PKNM-...
Let-through energy J
According to IEC/EN 60898 Let-through energy J
According to IEC/EN 60898
Fuse Fuse
Z-D0.../S... Z-D0.../S...
Let-through current characteristic curve Time current curve
10 A
13 A
16 A
20 A
25 A
32 A
40 A
0.5
1.5 1512345678910
10
3
10
4
10
5
8
6
4
2
1.5
8
6
4
2
8
6
4
3
1.5
PKNM.../B...
6 A
i2dt
[A2s]
cc rms [kA]
I
10 A
13 A
16 A
6 A
0.5
1.5 1512345678910
10
3
10
4
10
5
8
6
4
2
1.5
8
6
4
2
8
6
4
3
2
i dt
[A s]
PKNM.../C...
2
20 A
25 A
32 A
40 A
2
1.5
cc rms [kA]
I
2I
P
2I
P
2
20
10
4
2
1
0.4
0.2
0.10.1 0.2 0.4 12410 20 100
2
4
6
10
16
20
25
35
50
63
Possible peak short-circuit currents With large DC element
Without DC element
Let-through current I
D
in kA
Short-circuit current I
P
in kA
Rated current I
N
in A
10
3
10
2
10
1
10
0
10
-1
10
-2
10-
3
2410
1
2410
2
2410
3
2410
4
246 10162025355063
Fusing time in s
Unconditional current I
P
in A
Rated current I
N
in A
PKNM, Z-DO
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/35
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Miniature circuit-breakers
FAZ FAZ-…-DC FAZ-PN AZ
Electrical
Standards IEC/EN 60947-2
IEC/EN 60898 IEC/EN 61131-2 IEC/EN 60898 IEC/EN 61131-2
Rated operational voltage
V AC 230/400 230 230/400
V DC 48 (per pole) 250 (per pole) 48 (per pole) 60 (per pole)
Rated switching capacity kA 15 10 625
Operational switching capacity kA 7.5 20
Characteristic B, C, D CB, C Similar: D, C
Max. back-up fuse A gL/gG 125 100 100 200
Selectivity Class 333Compliant with Class 3
Lifespan Operations > 10000 > 10000 > 4000 > 10000
Direction of incoming supply As required Polarity dependent As required As required
Mechanical
Standard front dimension mm 45
Enclosure height mm 80 80 80 90
Terminal protection Finger and back-of-hand proof to BGV A2
Mounting width per pole mm 17.5 17.5 17.5 27
Mounting IEC/EN 60715 top-hat rail
Protection type IP20, IP40 (when fitted)
Terminals top and bottom Twin-purpose terminals Lift terminals
Terminal capacities
Solid mm21 x 25 1 x 25 1 x 16 2.5 … 50
flexible mm22 x 10 2 x 10
Thickness of busbar material mm 0.8 … 2 0.8 … 2
Mounting position As required
FAZ, AZ
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/36
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Residual current device
PKNM FIM AZFIMP FI F 100 A
FI 125 A and type B
Electrical
Standards IEC/EN 61009 IEC/EN 61009 IEC/EN 61131-2 IEC/EN 61008 IEC/EN 61008
Tripping A 250 (8/20m) non-delayed surge resistent Non-delayed, S
Rated operational voltage
U
eV AC 230 230/400 230/400 230/400 230/400
Limit values of the operating
voltage V AC 196 … 253 196 … 440 196 … 440 184 … 440 184 … 440
Rated frequency
f
Hz 50
Rated fault currents IDnmA 30, 300 30, 300 30, 300 30, 100, 300, 500 30, 100, 300, 500
Rated non-tripping current 0.5 x I dn0.5 x I dn0.5 x I dn0.5 x I dn0.5 x I dn
Rated fault switching
capacity IDmAIn = 16…40 A: 500
In = 63 A: 630
In = 80 A: 800
In = 100A: 1000
In = 125 A: 1250
for Type B:
60. 80 A: 800
40 A: 500
125 A: 1250
230 V kA 6
400 V kA 3
Sensitivity DC and pulsed current Pulsed current and
AC/DC
Rated switching capacity
I
cn kA 10 As fitted FAZ As fitted AZ 10 10
Operational switching
capacity
I
cs kA As fitted FAZ
Rated ultimate short-circuit
breaking capacity
I
cu As fitted AZ As fitted AZ
Rated short-circuit switching
capacity = Icu
Rated current IeA6 … 40 40, 63 80, 125 16 … 100 40 … 125
Rated impulse withstand
voltage
U
imp kV 6 (1.2/50 ms) 4 (1.2/50 ms) 6 6
Characteristic B, C
Maximum max. as short-
circuit protective device A gL 100 In = 16…63 A: 63
In = 80 A: 80
In = 100 A: 100
In = 125 A: 125
for Type B:
In F 80: 100
In = 125: 125
Selectivity Class 3
Lifespan
Electrical Operations > 4000 > – > 1500 > 4000 > 2000
Mechanical Operations > – > – > 10000 > 20000 > 5000
Mechanical
Standard front dimension mm 45 45 45 45 45
Enclosure height mm 80 90 90 80 85
Terminal protection Protection against electric shock to IEC 536
Mounting width mm 35 (2 space units) 70 (2-pole), 125 (4-
pole) 95 (5.5 space unit) 35 (2 space unit), 70
(4 space units) 70 (4 space unit)
Mounting Permanent screw
connection with
FAZ
Screwed on to AZ
(2- to 4-pole) Top-hat rail IEC/EN
60715 Top-hat rail IEC/EN
60715
Degree of protection
Switch IP 20
Integrated IP40 IP40 IP40 IP40 IP40
Terminals top and bottom Twin-purpose
terminals Lift terminals Lift terminals Twin-purpose
terminals Twin-purpose
terminals
Terminal capacities
Solid mm21 x 25 1 x (1 – 25) 2.5 … 50 1.5 … 35 1.5 … 50
flexible mm21 x (0.75 – 16) 2 x 16 2 x (1.5 – 16)
Thickness of busbar material mm 0.8 … 2 0.8 … 2 0.8 … 2 0.8 … 2
Admissible ambient
temperature range °C -25 … +40 -25 … +40 -25 … +40 -25 … +40 -25 … +40
Climatic proofing IEC/EN 61009 IEC/EN 61009 IEC/EN 60068-2 IEC/EN 61008 IEC/EN 61008
PKNM, FIM, AZFIMP, FI
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/37
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Auxiliary contacts, voltage releases
FAZ-XHIN11 FAZ-XHINW1 FAZ-XAM002 FAZ-XAA-C FAZ-XUA
Electrical
Rated operational voltage UeV AC 250 250 250 115, 230, 400
Contact function 1 NO + 1 NC 1 W 2 C/O
Voltage range V AC –––12 … 110
110 … 415
Closing threshold x
U
n––––0.8
Tripping threshold x
U
––––0.5
Rated frequency
f
Hz 50/60 50/60 50/60 50/60 50/60
Rated current IeA 6 6 4
Conventional free air thermal current Ith A 6 6 4
Rated operational current
AC-12
I
eA3 (250 V AC) 3 (250 V AC) 3 (250 V AC)
AC-15
I
eA2 (250 V AC) 2 (250 V AC) 2 (250 V AC)
DC-13
I
eA0.5 (110 V DC) 0.5 (110 V DC) 0.5 (110 V DC)
Rated insulation voltage UiV AC 250 250 250
Minimum operating voltage per contact
U
min V DC 555––
Rated impulse withstand voltage (1.2/50 ms)
U
imp kV 2.5 2.5 2.5
Rated conditional short-circuit current
With 6 A back-up fuse
I
sc kA 111––
Max. admissible back-up fuse A gL 664
Mechanical
Standard front dimension mm 45 45 45 45 45
Enclosure height mm 80 80 80 80 80
Mounting width mm 8.8 (0.5 space 8.8 (0.5 space 8.8 (0.5 space 17.5 (1 space 17.5 (1 space
Mounting max. 2 x on
MCB max. 2 x on
MCB On MCB IEC/EN 60715
top-hat rail IEC/EN 60715
top-hat rail
Degree of protection
Integrated IP40
Terminal protection Protection against electric shock to IEC 536
Terminals Lift terminals Lift terminals Lift terminals Twin-purpose
terminals Twin-purpose
terminals
Terminal capacities
Solid mm20.5 … 2.5 0.5 … 2.5 0.5 … 2.5 1 … 2.5 2 x (1 – 2.5)
flexible mm20.5 … 2.5 0.5 … 2.5 0.5 … 2.5 1 … 2.5 2 x (1 – 2.5)
Tightening torque of terminal screws Nm F 1.2 F 1.2 0.8 … 1.0 2.4 0.8
FAZ-XHIN, FAZ-X…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/38
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Auxiliary contacts, voltage releases
AZ-XHI11 AZ-XAA FI-XHI11 F 100 A FIPA-XAM011
125 A RCCB and
type B
Electrical
Contact function 1 M + 1 B 1 M + 1 B 1 C/O + 1 B
Voltage range V AC 12 … 110
110 … 415
Voltage range V DC 12 … 60
110 … 220
Min. operating voltage UeV/mA 24/50 24/50
Rated operational current
AC–-14
230 V IeA 6 6 6
AC–-13
250 V IeA 6 6
400 V IeA 2 2
DC–11
24 V IeA 4 1
DC-13
60 V IeA 4 4
110 V IeA 2 2
230 V IeA0.5 0.5
Rated insulation voltage UiV AC 440 440 440 440
Minimum operating voltage per contact
U
min V DC
Rated impulse withstand voltage (1.2/50 ms)
U
imp kV
Rated conditional short-circuit current With 6 A
back-up fuse
I
sc kA
Max. admissible back-up fuse A gL 6Inherently short-
circuit-proof 6 6
Lifespan
Mechanical Operations > 6000 > 4000 > 6000
Inrush current
AC A 38
Pick up time AC ms 2.1
DC A 34
Pick up time DC ms 2
Mechanical
Standard front dimension mm 45 45 45 45
Enclosure height mm 90 90 90 90
Mounting width mm 8.8 (0.5 space unit) 17.5 (1 space unit) 8.8 (0.5 space unit) 8.8 (0.5 space unit)
Mounting IEC/EN 60715 top-hat rail
Degree of protection
Integrated IP40
Switch IP 20
Terminal capacities
Solid mm21 x (1 – 25)
2 x (1 – 4) 1 x (1 – 25)
2 x (1 – 4) 2 x (0.5 – 2.5)
1 x (0.5 – 2.5) 2.5
flexible mm21 x (1 – 25)
2 x (1 – 4) 1 x (1 – 25)
2 x (1 – 4) 2 x (0.5 – 2.5)
1 x (0.5 – 2.5) 2.5
Tightening torque of terminal screws Nm 0.8 30.8 0.8
AZ-X…, FI-X…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/39
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Remote switching module, fuse material
FAZ/FIP-XAWM FAZ/FIP-XDWM
Electrical
Operational voltage range
V AC 220 … 240
V DC 48
Rated frequency
f
Hz 50/60
Relay output for alarm, 250 V AC, potential-free A 5 5
Function Automatic control
Function selector Automatic 5 x, OFF/RESET
Mechanical
Standard front dimension mm 45 45
Enclosure height mm 80 80
Mounting width mm 70 70
Mounting Top-hat rail to IEC/EN 60715
Degree of protection
Integrated IP40
Terminal protection Protection against electric shock to IEC 536
Terminals Lift terminals
Terminal capacities
Solid mm22 x 1.5
1 x 2.5 2 x 1.5
1 x 2.5
flexible mm22 x 1.5
1 x 2.5 2 x 1.5
1 x 2.5
D01-S0/ D02-S0/ D02-S/63/3-RS
Electrical
Number of poles 1P
3P 1P
3P 3P
Rated operating voltage
U
eV AC 400 400 400
V DC 250 250
Rated short-circuit current tested with links IekA 50 (AC) / 8 (DC) 50 (AC) / 8 (DC) 50
Rated frequency
f
Hz 40…60
Rated operational current IeA16 63 63
Conventional thermal current with fuse links Ith A63
Rated operating mode Uninterrupted operation
Overvoltage category III
Utilization category AC 23 B
Rated impulse withstand voltage Uimp kV ––8
Current heat loss per contact at IeW––0.5
Power loss
Heat dissipation per contact with fuse link at IeW––7.5
Max. permissible heat losses of the fuse links W 5.5
Utilization category gG (gL) gG (gL)
Mechanical
Standard front dimension mm 45 45
Enclosure height mm 68 68 212
Mounting width mm 27 (per pole) 27 (per pole) 36
Weight g 1P 76
3P 230 1P 76
3P 230 260
Electrical hoist E14 E18 E18
Mounting Quick attachment for top-hat rail IEC/EN 60715 Busbar with 60 mm
clearance
Degree of
protection Integrated IP30
Terminals Double function terminals Lift terminals
Terminal
capacities Solid mm21.5 … 35 1.5 … 35 1.5 … 25 Cu
Temperature range °C -25 … +55
Specified tightening torque for terminal screws Nm 2.5 … 3 2.5 … 3 max. 2.6
Pollution degree 3
Creepage resistance CTI 200 CTI 200
FAZ-FIP, D01-S, D02-S
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/40
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Fuse material
Z-SLS/NE0Z Z-SLK/NE0Z
Electrical
Number of poles 1P
1P+N
2P
3P
3P+N
1P
1P+N
2P
3P
3P+N
Rated operational voltage V DC 1P up to 110V / 2P up to 220V
Rated operating voltage
U
eV AC 400 400
Rated operational current IeA63 63
Rated uninterrupted current IuA63 63
Rated short-circuit making capacity 50 kAeff 50 kAeff
N/O 5A/250V
Switching category AC 22 B, DC 21 B AC 22 B, DC 21 B
Overvoltage category IV IV
Rated impulse withstand voltage Uimp kV 6 6
Current heat loss per contact at IeW0.5 0.5
Power loss
Heat dissipation per contact with fuse link at IeW7.5 7.5
Relay section electrical
Operating voltage range V AC 24 … 240
Operational voltage tolerance g10%
Power consumption VA 5
Frequency Hz 50…60
Function display Mains: 1 LED
Fault: 1 LED
Duty factor % 100
Response delay/On-delay ms 100
Recovery time tWms Approx.100
Relay contacts 2 changeover contacts,
5A/250V
Overvoltage category III
Auxiliary contacts
Rated impulse withstand voltage
U
imp kV 4
Mechanical
Standard front dimension mm 45 45
Enclosure height mm 86 86
Mounting width mm 27/per pole (1.5 SU) 27/per pole (1.5 SU) + 27
Weight g1P 113
1P+N 225
2P 224
3P 450
3P+N 472
1P 224
2P 345
3P 450
3P+N 472
Mounting Quick attachment for top-hat rail IEC/EN 60715
Integrated IP20 IP20
Terminals Lift terminals Lift terminals
Terminal capacities
Solid mm21.5 … 35 1.5 … 35
Temperature range °C -25 … +60 -25 … +60
Flammability classification to EN 60730 V0, glow-wire test 960°C
Specified tightening torque for terminal screws max. 4.5 max. 4.5
Pollution degree 3 3
Creepage resistance CTI 600 CTI 600
Relay section mechanical
Terminals Lift terminals Lift terminals
Terminal capacities
Solid mm20.14…4
flexible mm20.14…2.5
Specified tightening torque for terminal screws 0.5…0.7
Z-SLS, Z-SLK
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/41
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
Fuse switch-disconnectors, safety material
VLC14 VLC22
Electrical
Number of poles 1P
1P+N
2P
3P
3P+N
1P
1P+N
2P
3P
3P+N
Rated operating voltage
U
eV AC 690 690
Rated operational current IeA50 100
Rated conditional short-circuit current IekA 100 100
Rated frequency
f
Hz 50 50
Utilization category AC 22 B AC 21 B
Rated impulse withstand voltage Uimp kV 8 8
Fuse W gG: 5, aM: 3 gG: 9.5, aM: 7
Mechanical
Standard front dimension mm 45 45
Enclosure height mm 94 121
Mounting width mm 27/per pole 36/per pole
Weight g 1P 100
1P+N 222
2P 201
3P 308
3P+N 437
1P 160
1P+N 355
2P 310
3P 480
3P+N 680
Mounting Quick attachment for top-hat rail IEC/EN 60715
Degree of protection
Integrated IP20
Terminals Lift terminals
Terminal capacities
Solid mm21.5…10 2.5…35
Temperature range °C -25 … +60 -25 … +60
Specified tightening torque for terminal screws
Tightening torque Nm max. 2 max. 2.5
Pollution degree 1 1
Creepage resistance CTI 400 CTI 400
Z-D01/SE Z-D02/SE
Electrical
Rated operating voltage
U
eV AC 400 400
V DC 220 220
Utilization category gG (gL) gG (gL)
Rated frequency
f
Hz 45…65 45…65
Rated insulation voltage UiV2500 2500
Rated short-circuit switching capacity 50 kA (AC)
8 kA (DC) 50 kA (AC)
8 kA (DC)
Z-SLS/B Z-SLS/B24 Z-SLS/TR-SET
Electrical
Rated operational voltage V DC 24
Rated operating voltage
U
eV AC 60 … 400 24 400
Utilization category gG (gL) gG (gL)
Test voltage kV 555
Rated uninterrupted current IuA––63
VLC, Z-D0…, Z-SLS…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/42
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
NH fuse switch-disconnector
LTS-100/C00/3-R GST…00-160 GST…1 GST…2 GST…3
General
Standards IEC/EN 60947-3
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclical, to IEC 60068-2-30
Ambient temperature °C -25 … +55 -25 … +55 -25 … +55 -25 … +55 -25 … +55
Altitude m 2000 2000 2000 2000 2000
Mounting position Vertical, horizontal
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3
Degree of protection, from the front
Operational state IP20 IP20 IP20 IP20 IP20
Front cover open IP10 IP10 IP10 IP10 IP10
Direction of incoming supply As required
Weight kg 0.57 0.72 GSTA
0.93 GST 2.5 GSTA
4.4 GST 3.3 GSTA
5.3 GST 4.6 GSTA
6.6 GST
Contacts
Rated operational voltage UeV AC 500 500
690 500
690 500
690 500
690
Rated operational voltage UeV DC
220 220
440 220
440 220
440 220
440
Rated operational current IeA100 160
100 250
200 400
315 630
500
Rated frequency Hz 40 – 60 40 – 60 40 – 60 40 – 60 40 – 60
Rated conditional short-circuit current AC kArms 50 50 50 50 50
Rated conditional shortcircuit current DC kArms 25 25 25 25 25
Utilization category AC22B
Rated making capacity A 300 480
300 750
600 1200
945 1890
1500
Rated breaking capacity A 300 480
300 750
600 1200
945 1890
1500
Utilization category DC21B
Rated making capacity A 400 150 300 475 750
Rated breaking capacity A 400 150 300 475 750
Lifespan, electrical Switching operations 300 300 200 200 200
Lifespan, mechanical Switching operations 1700 1700 1400 800 800
Heat dissipation at Ith AC, without NH-SE W 11.5 6.9
2.7 12.9
8.3 27
16.7 52
32.8
Heat dissipation at Ith DC, without NH-SE W 7.7 4.6
1.8 8.6
5.5 18
11.2 34.7
21.8
Rated insulation voltage UiV AC 500 750 750 750 750
Max. fuse
Size NH000 NH00 NH1 NH2 NH3
Max. rated current gG/g A 100 160 250 400 630
Max. admissible heat dissipation NH-SE P
v
W7.5 12 23 34 48
Terminal capacity
Box terminal
Stranded mm21.5 – 50 1.5 – 70
Copper strip
Number of segments
x
width
x
thickness
mm 6 x 9 x 0.8 6 x 9 x 0.8
Tightening torque Nm 2.6 2.6
Box terminal
Stranded 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Copper strip mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Tightening torque mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Tightening torque Nm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Box terminal
Stranded copper mm21.5 … 70 25 … 150 25 … 240 25 … 300
Copper braid
Number of segments
x
width
x
thickness
mm 6 x 16 x 0.8 10 x 16 x 0.8 11 x 21 x 1
Tightening torque Nm 9.5 23 23
Clamp-type terminal
Stranded aluminium/copper mm270 … 150 120 … 240 120 … 300
Tightening torque Nm 4.5 11 11
Double clamp-type terminal
Stranded aluminium/copper mm22 x (70 …
95) 2 x (120 …
150) 2 x (120 …
240)
Tightening torque Nm 4.5 11 11
LTS…, GST…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/43
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical data
Low-voltage h.b.c. switch-fuse units
NH-SLS-00/160(-60) NH-SLS-1/250 NH-SLS-2/400 NH-SLS-3/630
Electrical
Technical data to IEC/EN 60947-3
Size 00 1 2 3
Number of poles/phases 3 3 3 3
Conventional free-air current
with low-voltage h.b.c fuse links Ith A160 250 400 630
Max. permissible rated heat dissipation
of the low-voltage h.b.c. fuse links W 12 23 34 48
Utilization category AC 23 B
Rated operational voltage UeV AC 400 500 500 500
Rated operational current IeA160 250 400 630
Rated conditional short-circuit current
with fuse protection kA 50 100 100 100
Utilization category AC 22 B, AC 21 B
Rated operational voltage UeV AC 690 690 690 690
Rated operational current IeA160 250 400 630
Rated conditional short-circuit current
with fuse protection kA 50 100 100 100
Rated insulation voltage UiV1000 1000 1000 1000
Overvoltage category III III III III
Rated impulse withstand voltage Uimp kV 812 12 12
Rated frequency Hz 50…60 50…60 50…60 50…60
Rated operating mode Uninterrupted operation1)
Power consumption without low-voltage h.b.c. fuse links 20 W at 160 A 30 W at 250 A 67 W at 400 A 116 W at 630 A
Mechanical
Mounting on busbars
Spike terminal for busbar thickness mm 10 (5 … 10) 10 10 10
Screw for busbar thickness mm 5 … 10
M8 (without screws) 5 … 10
M12 5 … 10
M12 5 … 10
M12
Standard connection screw M8 M10 M10 M12
Cable lug – Cu conductor according to rated currents to
IEC/EN 60947-1 mm21 x 70 120 240 2 x 185
Current busbar max. width mm 20 30 30 30
Ambient temperature range °C –5 … +40 –5 … +40 –5 … +40 –5 … +40
Degree of protection IP30 IP30 IP30 IP30
Pollution degree 3 3 3 3
Notes 1) With uninterrupted operation of several adjaced devices the rated diversity factor to EN 60439-1, Tabel 1 must be observed.
The distance to earthed parts must be at least 50/100 mm at the top and 25/50 mm on the sides with sizes 00/1-3.
NH-SLS
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/44
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Technical data
Low-voltage h.b.c. switch-fuse units
NH-SLS-00/160(-60)-SI NH-SLS-1/250-SI NH-SLS-2/400-SI NH-SLS-3/630-SI
Electrical
Technical data to IEC/EN 60947-3
Size 00 1 2 3
Number of poles/phases 3 3 3 3
Conventional free-air current
with low-voltage h.b.c fuse links Ith A160 250 400 630
Max. permissible rated heat dissipation
of the low-voltage h.b.c. fuse links W 12 23 34 48
Utilization categories AC 23 B, AC 22 B, AC 21 B
Rated operational voltage UeV AC 400 400 400 400
Rated operational current IeA160 250 400 630
Rated conditional short-circuit current
with fuse protection kA 50 100 100 100
Rated insulation voltage UiV400 400 400 400
Rated impulse withstand voltage Uimp kV 4 4 4 4
Rated frequency Hz 50…60 50…60 50…60 50…60
Rated operating mode Uninterrupted operation1)
Overvoltage category III III III III
Power consumption without low-voltage h.b.c. fuse
links 20 W at 160 A 30 W at 250 A 67 W at 400 A 116 W at 630 A
Mechanical
Mounting on busbars
Spike terminal for busbar thickness mm 10 (5…10) 10 10 10
Screw for busbar thickness mm 5…10
M8 (without screws) 5…10
M12 5…10
M12 5…10
M12
Standard connection screw M8 M10 M10 M12
Cable lug – Cu conductor according to rated cur-
rents to IEC/EN 60947-1 mm21 x 70 120 240 2 x 185
Current busbar max. width mm 20 30 30 30
Ambient temperature range °C –5…+40 –5…+40 –5…+40 –5…+40
Degree of protection IP30 IP30 IP30 IP30
Pollution degree 3 3 3 3
Electronic fuse monitoring
Electrical
Rated voltage V AC 3 x 400
Rated frequency Hz 50…60
Rated insulation voltage UiV400
Overvoltage category III
Rated impulse withstand voltage Uimp kV 4
Relay contacts
2 changeover contacts 1 A, 250 V
Mechanical
Terminals Lift terminals
Terminal cross-section
Solid mm22 x 2.5
Flexible mm22 x 1.5
Tightening torque of terminal screws Nm 0.8
Notes 1) With uninterrupted operation of several adjaced devices the rated diversity factor to EN 60439-1, Tabel 1 must be observed.
The distance to earthed parts must be at least 50/100 mm at the top and 25/50 mm on the sides with sizes 00/1-3.
NH-SLS…-SI
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/45
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Technical Data
LV h.b.c. fuse bases
GS00-160 GSU1 GSU2 GSU3
General
Standards IEC/EN 60 269-2-1;
VDE0636-201
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclical, to IEC 60068-2-30
Ambient temperature °C -25 … +55 -25 ... +55 -25 ... +55 -25 ... +55
Altitude m 2000 2000 2000 2000
Mounting position Vertical, horizontal Vertical, horizontal Vertical, horizontal Vertical, horizontal
Overvoltage category/pollution degree III/3 III/3 III/3 III/3
Degree of protection, from the front
Operational state IP00 IP00 IP00 IP00
Direction of incoming supply As required As required As required As required
Weight kg 0.4 1.7 2.1 2.7
Contacts
Rated operational voltage UeV AC 690 690 690 690
Rated operational voltage UeV DC
440 440 440 440
Rated operational current IeA160 250 400 630
Rated frequency Hz 40 – 60 40 – 60 40 – 60 40 – 60
Heat dissipation at Ith AC, without NH-SE W 6.9 12.9 27 52
Heat dissipation at Ith DC, without NH-SE W 4.6 8.6 18 34.7
Rated insulation voltage UiV AC 750 750 750 750
Max. fuse
Size NH00 NH1 NH2 NH3
Max. rated current gG/g A 160 250 400 630
Max. admissible heat dissipation NH-SE P
v
W12 23 34 48
Terminal capacity
Box terminal
Stranded mm2
Copper strip Number of segments x
width x thickness mm
Tightening torque Nm
Box terminal
Stranded 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Copper strip mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Tightening torque mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Tightening torque Nm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8
Box terminal
Stranded copper mm21.5 … 70 25 – 150 25 – 240 25 – 300
Copper braid Number of segments x
width x thickness mm 6 x 9 x 0.8 6 x 16 x 0.8 10 x 16 x 0.8 11 x 21 x 1
Tightening torque Nm 2.6 9.5 23 23
Clamp-type terminal
Stranded aluminium/copper mm270 – 150 120 – 240 120 – 300
Tightening torque Nm 4.5 11 11
Double clamp-type terminal
Stranded aluminium/copper mm22 x 70 … 95 2 x 120 … 150 2 x 120 … 240
Tightening torque Nm 4.5 11 11
GS…, GSU…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/46
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Miniature Circuit-Breakers, Residual-Current Circuit-Breakers
Miniature circuit-breakers
FAZ... FAZ-PN-...
Miniature circuit-breakers
AZ...
Residual-current protective modules Combined RCD/MCB devices
FIM-... PKNM-...
Residual-current protective modules
AZFIM...
Residual current device
FI-...
70
45
8
60
44
5.552.535
17.5
80
45
9.5
60
44
5.5
17.5
80
108
45
60
44
5.5
15
8154
27
90
70
90
45
9.5
5.5
60
44
125
90
45
9.5
5.5
60
44
35
80
94.5
45
5.5
60
44
90
108
94.5
90
54
70
45
10.5
5.5
60
44
80
35
72
45
9.5
31
6
60
44
85
FAZ, AZ, FIM, PKNM, AZFIM
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/47
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Shunt releases, undervoltage releases, restarting module
Auxiliary contacts
FAZ-XHIN11 FAZ-XAM002
AZ-XHI11 FIP-XHI11 FIPA-XAM011
Shunt releases Shunt releases Undervoltage releases
FAZ-XAA-C... AZ-XAA... FAZ-XUA...
Restarting module
FAZ/FIP-... Z-FW-LP
Z-FW-LPD
Z-FW-MO
45
80
44
60
5.5
8.8
45
80
44
60
5.5
8.8
9
90
445.5
60
45
8.8
80
235.5
44
60
45
8.8
80
85
5.5 44
60
45
80
45
17.5
26.2 44
60
5.5 30.5 4.5 9.6
27
90
39.1
44 155.5
60
45
17.5
80
445.5
60
45
7018.4
80
44 11.85.5
60
70
45
70
18.4
80
44
FT
70
5.5
45
11.8
44
35
FT
80
45
FAZ-X, AZ-X, FAZ/FIP, FIP(A), Z-FW
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/48
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Busbars, fuse bases, fuse switch-disconnector
Busbars
EVG-16/...
Extension terminals
ZV-...-80A-...
Type a b b1 c
EVG-16/1PHAS/2MODUL 33 25.9 14 3.4
EVG-16/1PHAS/6MODUL 105 25.9 14 3.4
EVG-16/1PHAS/12MODUL 210 25.9 14 3.4
EVG-16/2PHAS/4MODUL 75.5 30.9 19 7.3
EVG-16/2PHAS/6MODUL 105 30.9 19 7.3
EVG-16/2PHAS/12MODUL 209.5 30.9 19 7.3
EVG-16/3PHAS/6MODUL 102.5 30.9 19 10.3
EVG-16/3PHAS/9MODUL 156 30.9 19 10.3
EVG-16/3PHAS/12MODUL 209.5 30.9 19 10.3
EVG-16/3PHAS/16MODUL 285 30.9 19 10.3
EVG-16/3PHAS/20MODUL 353 30.9 19 10.3
EVG-16/4PHAS/8MODUL 138 30.9 19 13.3
EVG-16/4PHAS/12MODUL 209.5 30.9 19 13.3
EVG-16/3PHAS/N/5MODUL/LS 156 30.9 19 10.3
EVG-16/3PHAS/N/8MODUL/LS 209.5 30.9 19 10.3
EVG-16/1PHAS/2MODUL/HI 60 25.9 14 3.4
EVG-16/1PHAS/6MODUL/HI 156.5 25.9 14 3.4
EVG-16/1PHAS/9MODUL/HI 237 25.9 14 3.4
EVG-16/2PHAS/4MODUL/HI 75.5 30.9 19 7.3
EVG-16/2PHAS/6MODUL/HI 120 30.9 19 7.3
EVG-16/2PHAS/10MODUL/HI 209.5 30.9 19 7.3
EVG-16/3PHAS/6MODUL/HI 115 30.9 19 10.3
EVG-16/3PHAS/12MODUL/HI 237 30.9 19 10.3
EVG-16/3x 1PHAS/6MODUL/HI 152 30.9 19 10.3
EVG-16/3x 1PHAS/8MODUL/HI 209.5 30.9 19 10.3
EVG-16/3x 1PHAS/9MODUL/HI 229 30.9 19 10.3
c
b1
b
a
1.5
65
17
46
Fuse base Busbar mounting switch-disconnector
D01-SO/...
D02-SO/... D02-S/63/3-RS
fuse switch-disconnector With fuse monitoring, empty
Standard, empty
Z-SLS/NEOZ/... Z-SLK/NEOZ/...
60
68
45
55627 81
36 77
5 – 10
3221
60
194
212
20 – 30
31.5
60
27 46
60
70
86
45
27 27 46
70
86
45
60
EVG-16, ZV, D0…-S, Z-SLS, Z-SLK
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/49
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Fuse base, fuse switch-disconnector
Fuse switch-disconnectors, empty
VLC14... VLC22...
27 42.55.2
54.6
70
45
90
94
36 42.56.2
54.6
70
45
117
121
Low-voltage h.b.c. fuse base
GSU1 GSU2 GSU3 GS00-160
Low-voltage h.b.c. fuse switch-disconnectors
1 pole 3 pole
GSTA00-160-1P GSTA00-160 GSTA1 GSTA2 GSTA3
30
25
50
o 5.5
o 5.5
o 10.5
7s
t
i
gg
q
h
r
c
b
a
d
e
f
o
32.5 32.5
104
88
o 7.5
25
58
136
Type a b c d e f g h i o q r s t
GSU1 175 200 248 M10 35 2 66 200 34 107 191 164 150 100
GSU2 200 225 248 M10 35 2 66 200 34 115 191 164 150 100
GSU3 210 250 273 M10 35 3 84 254 40 132.5 245 200 186 136
9
135
o 10.5
220.5
270
91
430
96
147
30.5
Part no. a a1 b b1 b2 b3 b4 b5 c c3 d e f
GSTA00-160-1P 49 - 169 79 149 120 - - 86.5 - 7 - -
GSTA00-160 106 66 169 79 149 120 25 26 86.5 197 7 50 -
GSTA1 182 116 250 115 230 184 30 23 111 294 5.5 150 -
GSTA2 208 132 275 128 256 217 30 19,5 125 330.5 5.5 175 25
GSTA3 254 164 283 135 270 238 30 16 142 348 5.5 200 50
VLC, GS…, GST…
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
Moeller HPL0211-2007/2008
16/50
http://catalog.moeller.net
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Fuse bases, fuse switch-disconnectors
Low-voltage h.b.c. fuse switch-disconnectors
Drilling dimensions LTS-100/C00/3-R
GSTA00-160-1P GSTA2
GSTA1 GSTA3
60 60
194
63 5 – 10
31.5 32
60
101
12 – 30 31.5
e
d
25
d
50
e
f
Part no. a a1 b b1 b2 b3 b4 b5 c c3 d e f
GSTA00-160-1P 49 - 169 79 149 120 - - 86.5 - 7 - -
GSTA00-160 106 66 169 79 149 120 25 26 86.5 197 7 50 -
GSTA1 182 116 250 115 230 184 30 23 111 294 5.5 150 -
GSTA2 208 132 275 128 256 217 30 19,5 125 330.5 5.5 175 25
GSTA3 254 164 283 135 270 238 30 16 142 348 5.5 200 50
GST00-160-40-60-AOU
GST1-... GST2-...
151
229
4
112
158
12/20/30
40/50/6040/50/60
106.4
194
33 31
GUV
5 – 15 32
35
10140
60
135
12
105.5
33
.../ES00
G0V
GU/195
G0/195
k
a
c
b
g
e
.../A0
l
l1
h6060
F 30
d
j
kF 10 i .../AU
.../ES00
f
Part no.abcdefghijkll1
GST1-… 184 230 247 70 121 16.5 115 42 27 55 58 151 161
GST2-… 210 256 272 83 135 16.5 128 53 27 55 66 165 175
GS00160, GST(A), LTS
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616
16/51
http://catalog.moeller.net Moeller HPL0211-2007/2008
Miniature circuit-breakers
Residual-current circuit-breakers
Dimensions
Fuse switch-disconnectors, NH fuse switch-disconnectors
Low-voltage h.b.c. fuse switch-disconnectors
GST3-...
NH-SLS-00/160
NH-SLS-00/160-SI NH-SLS-00/160-60
NH-SLS-00/160-60-SI
NH-SLS-1/250
NH-SLS-1/250-SI
NH-SLS-2/400
NH-SLS-2/400-SI
NH-SLS-3/630
NH-SLS-3/630-SI
a NH-SLS…-SI
(with safety monitoring)
82 82
254
5 – 10 54
117
119.5
170.5
430
350
80
141 60 60
20 – 30
216 134
33 5.533
84.5
50 31 67.5
120
289
455
26.5
26.5
F 238
a 610
33 5.533
100.5
50 15 83.5
136
26.5
26.5
289
455
a 610
50
99
58
F 457
197
148
145
14.5
764
57
322 258
16.5580
610
a 908
GST, NH-SLS