EC 26 www.recom-international.comAugust 2002
Selection Guide
ECONOLINE - DC/DC-Converter
RK and RH Series, 1 Watt, SIP7, 3kV/4kV (Single & Dual Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Part Input Output Output Efficiency
Number Voltage Voltage Current
SIP 7 (4kV) (VDC) (VDC) (mA) (%)
RK-XX1.8S (H) 1.8, 3.3, 5, 9, 12, 15, 24 1.8 555 70
RK-XX3.3S (H) 1.8, 3.3, 5, 9, 12, 15, 24 3.3 303 75
RK-XX05S (H) 1.8, 3.3, 5, 9, 12, 15, 24 5 200 70-78
RK-XX09S (H) 1.8, 3.3, 5, 9, 12, 15, 24 9 111 70-80
RK-XX12S (H) 1.8, 3.3, 5, 9, 12, 15, 24 12 84 78-82
RK-XX15S (H) 1.8, 3.3, 5, 9, 12, 15, 24 15 66 78-82
RK-XX24S (H) 1.8, 3.3, 5, 9, 12, 15, 24 24 42 74-83
RH-XX1.8D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±1.8 ±278 70
RH-XX3.3D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±3.3 ±152 70
RH-XX05D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±5 ±100 70-78
RH-XX09D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±9 ±56 75-80
RH-XX12D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±12 ±42 78-84
RH-XX15D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±15 ±33 80-84
RH-XX24D (H) 1.8, 3.3, 5, 9, 12, 15, 24 ±24 ±21 80-84
Input Voltage ±10%
Input Filter Capacitor Type
Output Voltage Accuracy ±5%
Line Voltage Regulation 1,2%/1% V Input
Load Voltage Regulation 1.8V, 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Ripple and Noise (20MHz limited) Single output types 100mVp-p max.
Dual output types ±75mVp-p max.
Efficiency at Full Load 70% min.
Isolation Voltage 3.000VDC min.
(also available with 4.000VDC, Suffix ‘H’)
Isolation Resistance (Viso = 500VDC) 15 GΩmin.
Isolation Capacitance 20pF min./65pF max.
Short Circuit Protection 1 Second
Switching Frequency at Full Load 57kHz min. / 105kHz max.
Operating Temperature –40°C to +85°C (see Graph)
Storage Temperature -55°C to +125°C
Package Weight 2.8g
●3kVDC (4kVDC Option) Isolation
●Power Sharing on Dual Output
●Efficiency to 78%
●1.8, 3.3, 5V, 9V, 12V, 15V and 24V
Output
●Custom Solutions Available
●UL94V-0 Package Material
Features