IS01DBFRGB Version (1)
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 2
DISTINCTIVE CHARACTERISTICS
• High resolution of 64 x 32 pixels
• 64 colors of backlighting can be controlled dynamically
• Display with LCD, RGB LED backlighting
• General brightness of backlight is dynamically controlled in eight steps from dark to bright
• Operated by commands and data supplied via serial communications (SPI)
• Can display as many as four lines of text with ten characters each
• Incorporates bitmap display function
• Programmable display graphics for alphanumeric characters and animated sequences
• Dual image VRAM for quick change of displayed images
• Low energy consumption
• Dust tight construction
Viewing area: 13.9mm x 10.6mm (horizontal x vertical)
Bracket has crimped legs to ensure secure PC mounting
and prevent dislodging during wave soldering
Actual Size
SMARTSWITCHTM
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 3
LCD SPECIFICATIONS
Characteristics of Display
Display Operation Mode FSTN positive; background colors, black & white
Display Condition Transective with built-in LED backlight
Viewing Angle Direction 6 o’clock
Viewing Area 13.9mm x 10.6mm (horizontal x vertical)
Pixel Format 64 x 32 pixels (horizontal x vertical)
Pixel Size 0.18mm x 0.24mm (horizontal x vertical)
*Operating Temperature Range –15°C ~ +50°C (+5°F ~ +122°F)
Storage Temperature Range –20°C ~ +60°C (–4°F ~ +140°F)
Backlight LED RGB: red/green/blue
* In a low temperature environment (below 0°C), speed and contrast decrease when image changes. The non-indicator dot may become dense in
a high temperature environment (about +50°C).
Absolute Maximum Ratings
Items Symbols Ratings
Supply Voltage VDD –0.3V to +7.0V
Input Voltage VI–0.3V to VDD +0.3V
Output Voltage VO–0.3V to VDD +0.3V
Recommended Operating Conditions
Items Symbols Minimum Typical Maximum
Supply Voltage VDD 4.9V 5.0V 5.1V
Input Voltage VI0V –– VDD
SPI Clock Frequency fSCK –– –– 8MHz
Current Consumption IDD ** 10mA –– *** 50mA
** 10mA: Backlighting LED is off
*** 50mA: Backlighting LEDs (Red, Green, Blue) are maximum brightness
Optical Characteristics (Temperature at 25°C)
Items Symbols Min Typical Max
Contrast Ratio Cr –– 3.0 ––
Viewing
Angle
(Cr ≥ 1.1)
Up & Down q–– 90° ––
Right & Left f–– 90° ––
DISPLAY DESCRIPTION
Terminals LCD Mode LED Color LCD/LED
Straight PC Black & White
FSTN Positive Red/Green/Blue
SMARTSWITCHTM
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 4
BLOCK DIAGRAM & PIN CONFIGURATIONS
TYPICAL DISPLAY DIMENSIONS
(17.2)
.677
(10.7)
.421
(17.8)
.701
(14.4)
.567
(12.78)
.503
See
Pixel Detail
(13.9)
.547
(8.3)
.327 (10.6)
.417
(9.9)
.390 (3.0)
.118
(16.8)
.661
(0.4)
.016 Typ
(0.5)
.020 Sq Typ
(0.7)
.028
(4.0)
.157
(1.3)
.051
(2.0)
.079
Typ
(2.0)
.079
(15.0)
.591
(14.7)
.579
(0.65)
.026
(10.0)
.394
Typ
(3.1)
.122
21
65
Key
C
L
(2.0)
.079 Typ
(2.0)
.079
(15.0)
.591
(14.7)
.579
(10.0)
.394
(3.1)
.122
(4.0)
.157
(16.8)
.661
(0.9)
.035
3x
(0.9)
.035
4x (0.8)
.031
6x
Dia
Dia
Dia
12
56
FootprintPixel Detail
Terminal numbers are not on the device.
Pin No. Symbol Name Function
SCK Serial Clock Clock line for SPI that synchronizes commands and data
SS Slave Select Chip select for SPI; line is active low
SDO Data Out Data output line for SPI
SDI Data In Data input line for SPI
GND Ground
VDD Power Power source for logic circuit and LCD
6
5
4
3
2
1
DD
V
Shift Register
64bit
seg1.......seg64
64 x 32 Dot Matrix
Common Driver
Shift Register
32bit
Com1......Com32
LCD Panel
Red
Green
Blue
Display Controller
Backlight LED
6
5
GND
SCK 1
SPI
2
SS
3
SDI 4
SDO
Segment Driver
RAM #1
256Byte
RAM #2
256Byte
LED Driver
(0.02)
.0008
(0.18)
.007
Typ
(0.24)
.009
High Resolution SMARTDISPLAYTM
with RGB LED and
Black and White LCD Mode
SMARTSWITCHTM
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 5
SPI Timing Chart (SS Using) SPI Timing Chart (SS Low Level Fixed)
SDI and SCK shall be kept high when idle.
tsSS
tcycCK thwCK
thSS
tsDI thDI
tdDO
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0
SS
SCK
SDI
SDO
tcycCK thwCK
tsDI thDI
D7 D6 D5 D4 D3 D2 D1 D0
tdDO
D7 D6 D5 D4 D3 D2 D1 D0
SS
SCK
SDI
SDO
Low
Circuit Example
TIMING SPECIFICATIONS
SPI Characteristics (See Timing Diagram)
(Temperature at –15°C ~ +50°C and VDD = 5.0V ± 2%)
Items Symbols Minimum Maximum
SPI_SS Set Up Time tsSS 10ns
SPI_SS Hold Time thSS 10ns
SPI_CLK Cycle tcycCK 8MHz
SPI_CLK Width thwCK 10ns
SPI_DI Set Up Time tsDI 10ns
SPI_DI Hold Time thDI 10ns
SPI_DO Delay Time tdDO 10ns
BITMAP
Segment
Common 1 2 3 4 5 6 7 8 9 • • • 16 • • • • • 49 • • • 56 57 58 59 60 61 62 63 64
Byte8 Byte7 • • • Byte2 Byte1
COM1 D0 D1 D2 D3 D4 D5 D6 D7 D0 • • • D7 • • • D0 • • • D7 D0 D1 D2 D3 D4 D5 D6 D7
Byte16 Byte9
COM2 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7
Byte256 • • • • • • Byte249
COM32 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7
Transferring Display Data/Displaying LCD Command and Data Sequence
Command Data (256 Bytes)
0 x 55 Byte1 Byte2 • • • Byte255 Byte256
0 1 0 1 0 1 0 1 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 • • • D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
Notes: Display RAM has two screen areas. The rst area is for the display on current LCD; the second area is for the data to be displayed next.
The screens are changed when the second area is fully stored.
SMARTSWITCHTM
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 6
COMMANDS & DATA
Transferring Display Data/Displaying on LCD
Command Data Remarks
Hex Binary
0 x 55 01010101 256 Bytes (64 x 32 = 2,048 bits) See below for details of bitmap data
LED (Backlight) Color Set
Command Data Remarks
Hex Binary
R R G G B B 1 1
2 bits x 3
For each of RGB:
0 x 40 01000000 00 = off
01 = 1/4
10 = 1/2
11 = full
LED (Backlight) Brightness Set
Command Data Remarks
Hex Binary
For leading 3bits:
0 x 41 01000001 * * * 1 1 1 1 1
3 bits
000 = 1/20
(dark)
001 = 1/10
010 = 1/7
011 = 1/5
100 = 1/3
101 = 1/2
110 = 2/3
111 = full
(bright)
Reset (Returning to Initial Status at Power Activation)
Command Data Remarks
Hex Binary
0 x 5E 01011110 00000011 Returning to initial status at power activation
• Transferring display data/displaying on LCD: command (1 Byte) + data (256 Bytes)
• Others: command (1 Byte) + data (1 Byte)
• Commands can be accepted only when all bits coincide; otherwise, they are not acknowledged
• Additional commands will not be received until the communication of commands (1 Byte) and data (256 or 1 Byte) is completed
• There is no time limit from the beginning to end of data receipt
• Commands may be executed consecutively (no need to wait between commands)
• Irregular commands or data are not recognized
• Initial status at power activation: LCD display off, LED off (brightness 1/20, color off)
SMARTSWITCHTM
NKK Switches • email: smartswitch@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkksmartswitch.com 7
Handling
1. The IS Series devices are electrostatic sensitive.
2. The IS series devices are not process sealed.
3. If the LCD is accidentally broken, avoid contact with the liquid and wash off any liquid spills to the skin or
clothing.
4. Clean cap surface with dry cloth. If further cleaning is needed, wipe with dampened cloth using neutral
cleanser and dry with clean cloth. Do not use organic solvent.
5. Recommended soldering time and temperature limits: 5 seconds maximum @ 270°C maximum
6. Do not exceed 60°C at the LCD level.
Storage
1. Store in original container and away from direct sunlight.
2. Keep away from static electricity.
3. Avoid extreme temperatures, high humidity, gaseous substances, and all forms of chemical contamination.
PRECAUTIONS FOR HANDLING & STORAGE OF LCD DEVICES
ATTENTION
ELECTROSTATIC
SENSITIVE DEVICES