G3MB G3MB
2
Note: Data shown are of initial value.
Type G3MB-202P G3MB-202PL
G3MB-202PEG G3MB-202PLEG
Operate time 1/2 of load power source 1 ms max.
cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.60 V (RMS) max.
Leakage current 1 mA max. at 100 VAC, 1.50 mA at 200 VAC
Non-repetitive peak surge 30 A
Output PIV (VDRM) 600 V
di/dt 40 A/µs
dv/dt 100 V/µs
I2t4 A
2s
Junction temperature (Tj) 125°C (257°F) max.
Insulation resistance 1,000 MΩ min. at 500 VDC
Dielectric strength 2500 VAC, 50/60 Hz for 1 minute; 3750 VAC max., 1 second
Vibration Malfunction 10 to 55 Hz, 0.75 mm (0.03 in) double amplitude, approx. 5 G
Shock Malfunction Approx. 100 G
Ambient temperature Operating -30° to 80°C (-22° to 176°F) with no icing
Storage -30° to 100°C (-22° to 212°F) with no icing
Humidity Operating 45% to 85% RH
Weight Approx. 5 g (0.18 oz)
■CHARACTERISTICS
■INPUT RATING
Models with input resistor
Specifications
Rated voltage Operating range Input impedance
5 VDC 4 to 6 VDC 440 Ω ±20%
12 VDC 9.60 to 14.40 VDC 1k Ω, ±20%
24 VDC 19.20 to 28.80 VDC 2.20k Ω, ±20%
■OUTPUT RATING
Model Rated load voltage Load voltage range Load current Surge current
G3MB-202 100 to 240 VAC 75 to 264 VAC 0.10 to 2 A 30 A (60 Hz, 1 cycle)
■LED DRIVE DATA
Models without input resistor
LED forward current 50 mA max.
Repetitive peak LED forward current 1 A max.
LED reverse voltage 5 V max.
■RECOMMENDED LED OPERATING CONDITIONS
Models without input resistor
Min. Standard Max.
LED forward current 5 mA 10 mA 20 mA
Must drop voltage 0 — 1 V