ATV320U07M2B Product data sheet Characteristics Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Variable speed drive, Altivar Machine ATV320, 0.75 kW, 200...240 V, 1 phase, book Main Range of product Altivar Machine ATV320 Product or component type Variable speed drive Product specific application Complex machines Variant Standard version Standard version Mounting mode Cabinet mount Communication port protocol Modbus serial CANopen Option card Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, Profinet Communication module, Ethernet Powerlink Communication module, Ethernet/IP Communication module, DeviceNet [Us] rated supply voltage 200...240 V - 15...10 % Nominal output current 4.8A Motor power kW 0.75kW for heavy duty EMC filter Class C2 EMC filter integrated IP degree of protection IP20 Complementary Discrete input number 7 Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0...30kHz, 24 V DC (30 V) Discrete input logic Positive logic (source) Negative logic (sink) Discrete output number 3 Discrete output type Open collector DQ+ 0...1kHz 30 V DC 100mA Apr 16, 2021 1 Open collector DQ- 0...1kHz 30 V DC 100mA Analogue input number 3 Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits Analogue output number 1 Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470Ohm, resolution 10 bits Relay output type Configurable relay logic R1A 1 NO electrical durability 100000cycles Configurable relay logic R1B 1 NC electrical durability 100000cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000cycles Configurable relay logic R2C Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7ms: 2A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7ms: 2A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5A at 30 V DC Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5mA at 24 V DC Method of access Slave CANopen 4 quadrant operation possible True Asynchronous motor control profile Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points Synchronous motor control profile Vector control without sensor Maximum output frequency 0.599kHz Transient overtorque 170...200% of nominal motor torque Acceleration and deceleration ramps Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Motor slip compensation Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points) Switching frequency 2...16 kHz adjustable 4...16 kHz with derating factor Nominal switching frequency 4 kHz Braking to standstill By DC injection Brake chopper integrated True Line current 10.1A at 200 V (heavy duty) 8.5A at 240 V (heavy duty) Maximum input current 10.1A Maximum output voltage 240V Apparent power 2.0kVA at 240 V (heavy duty) Network frequency 50...60 Hz Relative symmetric network frequency tolerance 5% Prospective line Isc 1kA Base load current at high overload 17.0A Power dissipation in W Fan: 46.0W at 200 V, switching frequency 4 kHz With safety function Safely Limited Speed (SLS) True With safety function Safe brake management (SBC/SBT) False 2 With safety function Safe Operating Stop (SOS) False With safety function Safe Position (SP) False With safety function Safe programmable logic False With safety function Safe Speed Monitor (SSM) False With safety function Safe Stop 1 (SS1) True With sft fct Safe Stop 2 (SS2) False With safety function Safe torque off (STO) True With safety function Safely Limited Position (SLP) False With safety function Safe Direction (SDI) False Protection type Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive Width 45.0mm Height 325.0mm Depth 245.0mm Net weight 2.4kg Environment Operating position Vertical +/- 10 degree Product certifications CE ATEX NOM GOST EAC RCM KC Marking CE ATEX UL CSA EAC RCM Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 s - 8/20 s surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Environmental class (during operation) Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 Maximum acceleration under shock impact (during operation) 150 m/s at 11 ms Maximum acceleration under vibrational stress (during operation) 10 m/s at 13...200 Hz Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3 Volume of cooling air 11.3m3/h Overvoltage category III Regulation loop Adjustable PID regulator Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Pollution degree 2 Ambient air transport temperature -25...70C 3 Ambient air temperature for operation -10...50C without derating 50...60C with derating factor Ambient air temperature for storage -25...70C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 2.26kg Package 1 Height 8.5cm Package 1 width 27.5cm Package 1 Length 32.5cm Unit Type of Package 2 P06 Number of Units in Package 2 24 Package 2 Weight 68.83kg Package 2 Height 80cm Package 2 width 80cm Package 2 Length 60cm Offer Sustainability Sustainable offer status Green Premium product REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Upgradeability Upgraded components available 4 Product data sheet Dimensions Drawings ATV320U07M2B Dimensions Bottom, Right and Front View 5 Product data sheet Mounting and Clearance ATV320U07M2B Mounting and Clearance (1) (2) Minimum value corresponding to thermal constraints. Optional GV2 circuit-breaker 6 Product data sheet Mounting and Clearance ATV320U07M2B Option: Protection Device, GV2 circuit-breaker NOTE: The product overall height dimension, including GV2 adapter and EMC plate mounted, becomes 424 mm (16.7 in.) instead of 325mm (12.80in.) (1) Ground screw (HS type 2 - 5x12) 7 Product data sheet Connections and Schema ATV320U07M2B Connection Diagrams Diagram with Line Contactor Connection diagrams conforming to standards ISO13849 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) (2) Line choke (if used) Fault relay contacts, for remote signaling of drive status Diagram with Switch Disconnect Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) (2) Line choke (if used) Fault relay contacts, for remote signaling of drive status 8 Product data sheet Connections and Schema ATV320U07M2B Control Connection Diagram in Source Mode (1) (2) (3) (4) Analog output Analog inputs Reference potentiometer (10 kOhm maxi) Digital inputs 9 Product data sheet Connections and Schema ATV320U07M2B Digital Inputs Wiring The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. Switch SW1 set to "Source" position and use of the output power supply for the DIs. Switch SW1 set to "Source" position and use of an external power supply for the DIs. Switch SW1 set to "Sink Int" position and use of the output power supply for the DIs. Switch SW1 set to "Sink Ext" position and use of an external power supply for the DIs. 10 Product data sheet Performance Curves ATV320U07M2B Derating Curves Derating curve for the nominal drive current (In) as a function of temperature and switching frequency (SF). In : SF : 40 C (104 F) - Mounting type A, B and C 50 C (122 F) - Mounting type A, B and C 60 C (140 F) - Mounting type B and C Nominal Drive Current Switching Frequency 11