177 FIBER SENSORS Digital Fiber Sensor FX-300 SERIES Related Information LASER SENSORS General terms and conditions............ F-17 SC-GU1-485................................. P.935~ General precautions...................... P.1405 Sensor selection guide..................... P.3~ Glossary of terms........................ P.1359~ Korea's S-mark.............................. P.1410 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Conforming to EMC Directive Recognition AREA SENSORS Certified LIGHT CURTAINS NPN output types of connector type only PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS * Passed the UL 991 Environment Test * UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: UL 61010C-1] [Additional test / evaluation standards as per intended use: UL 991, SEMI S2-0200] PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS PNP output type available WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide panasonic-electric-works.net/sunx Constant advances achieving significant improvement of sensing performance Stable sensing over long and short periods FX-301 FX-301-HS FX-305 In addition to a "four-chemical emitting element" which suppresses changes in the light emitting element over time so that a stable level of light emission can be * * maintained over long periods, a "APC (Auto Power * Control) circuit" has also been adopted afreshly. The light emitting amount can be controlled in minute degrees so that even changes occurring over very short periods can be handled, allowing stable sensing performance by suppressing deviations in light emitting amounts caused by changes in the ambient environment that could not previously be suppressed. Timer Interference Light intensity monitor prevention Automatic sensitivity setting The digital fiber sensor FX-301(P) has been modified since its production in June 2004. Even greater sensing range All models Adoption of a "double coupling lens" that increases emission efficiency to its maximum limits and greatly increases sensing range. Sensing ranges with small diameter fibers and ultra-small diameter fibers, which have become very popular due to the miniaturization of chip components, have been increased by 50 % over previous values achieved with other amplifiers. * Conventional fiber sensors (Without lens) Stable sensing comparison Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Light emitting amount Fibers Short-term stability Disperses the light reduces emitting efficiency. Deviation * Double coupling lens Long-term stability Time FX-301 FX-301-HS FX-305 Three-chemical emitting element, Without APC The lens concentrates the light, greatly increasing emitting efficiency. Digital Fiber Sensor FX-300 SERIES APPLICATIONS 178 FIBER SENSORS Detecting the presence or absence of labels Detecting the presence or absence of ICs on a tray The light-emitting amount selection function can even stabilize detection of transparent labels that saturate the light-receiving level. You can set upper and lower limits for the threshold values using the window comparator mode and turn ON / OFF the incident light intensity within that limit. Detecting the passage of small objects The differential sensing mode will only detect rapid changes in the amount of light, which makes it possible for small objects to be detected. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS FX-301 FX-301-HS FX-305 Light-emitting amount selection If the light receiving level becomes saturated during close-range sensing or when sensing transparent or minute objects, you can adjust the light emitting amount of the sensor to stabilize sensing without needing to change the response time. Sensing that previously required the response time or fibers to be changed can now be set much more easily using this function. [Light receiving level saturated] A 4000 Actual digit difference: C Upper display limit B Saturated digit difference: D , A , B Actual digit difference: C' Level 3 WIRE-SAVING SYSTEMS Level 2 MEASUREMENT SENSORS STATIC CONTROL DEVICES Level 1 ENDOSCOPE OFF Light emitting amount can be changed without changing response time FX-305 Ultra high-speed 35 s response FX-301-HS Large display with 4 digits (9999). With a greater difference in digit value than previous models, threshold values can be set in units of 1 digit up to maximum 9999. Threshold setting can now be done more easily and accurately. Ultra high-speed 35 s response. Even small objects moving at high speeds can be sensed. In addition, at 65 s the FX-301 standard 4 times as fast type and FX-305 highas before function type is also twice as fast as previous models. Large display 9999 (During STDF, LONG and U-LG modes) 2.5 times previous models Digit difference comparison Example Digit difference between object A and object B Previous models FX-305 4000 9999 35 s Ultra high-speed type FX-301-HS (H-SP mode) 35 s Standard type FX-301, High-function type FX-305 65 s Digit difference: Large LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 (H-SP mode) Digit difference: Small SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Level 4 [Stable sensing] Light emitting amount changed PARTICULAR USE SENSORS Previous model 150 s FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 179 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Digital Fiber Sensor FX-300 SERIES FX-305 Simplified systems using new operating modes A window comparator mode and differential sensing mode have been added. These modes make it easy to carry out sensing tasks that previously required multiple sensors or involved complex threshold settings. Window comparator mode Differential sensing mode LIGHT CURTAINS PARTICULAR USE SENSORS Tray absent IC present Tray present OFF ON OFF SENSOR OPTIONS Upper and lower limits for threshold values can be set so that the incident light intensity can turn on and off within those ranges. Single output is used, so that only one cable is required, and no PLC processing is required either. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Incident light intensity Lower light amounts due to dust Incident light intensity PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Because sensing is not possible at normal sensitivity settings, sensitivity must be reset. ON ON Sensing of only sudden changes in light amounts Only the target objects are sensed. No need to reset the sensitivity. FX-305 Equipped with 5 types timers The FX-305 includes the same ON-delay / OFF-delay / ONE SHOT timer as the FX-301(-HS), as well as an ON-delay * OFF-delay timer and an ON-delay * ONE SHOT timer. A wide variety of timer control operations can be carried out by these fiber sensors alone. Timer period Output 1: 0.5 to 9,999 ms (variable) Output 2: 0.5 to 500 ms (variable) Time chart MACHINE VISION SYSTEMS ON-delay * OFF-delay Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F ON-delay * ONE SHOT RUN TEACH ADJ RUN RUN TEACH ADJ TEACH RUN TEACH ADJ ADJ T1 ON OFF T1 ON T1 OFF T1 T1 T2 T2 ON OFF ON OFF All models Even beginners can quickly learn how to use the MODE NAVI MODE NAVI uses six indicators to display the amplifier's basic operations. The current operating mode can be confirmed at a glance, so even a first time user can easily operate the amplifier without becoming confused. OFF T1 OFF-delay ONE SHOT ON T1 ON-delay UV CURING SYSTEMS Beamreceived Beaminterrupted Sensing condition FA COMPONENTS Selection Guide For L-ON L / D L / D ON TIMER This mode allows the selection of output operation as either PRO Light-ON or Dark-ON. This is the sensing mode. Incident light level is displayed in the digital display. L / D TIMER TIMER This mode permits the choice of using or not PRO using the timer. This mode is for setting the threshold value. L / D PRO TIMER This mode allows the selection of further advanced functions, such as the copying of PRO individual settings and the memory functions. In this mode, the threshold value, once set, may be fine-tuned. FX-301 FX-301-HS FX-305 Easy confirming of threshold value settings The threshold value can be confirmed by turning the jog switch even during RUN mode. Jog switch is turned Left: FX-301(-HS) Right: Output 2 for Output 1 for FX-305 FX-305 The threshold value is displayed Digital Fiber Sensor FX-300 SERIES All models The use of only two switches makes for very simple operations Only two switches, the large jog switch and the large MODE key, are required for operation. You can operate it simply by the 3 steps shown on the right. Large MODE key Large jog switch 1 180 FIBER SENSORS LASER SENSORS 2 3 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Pressing the switch selects or cancels the operating mode Moving the switch from side to side allows items to be selected Pressing the switch then confirms the selected setting A quick-connection cable saves wiring and Connector type work-hours An optical communication function allows up to *16 sensors FX-301 FX-305 to be adjusted simultaneously One unit can be used as either a main unit or sub unit The optical communication function allows the data that is currently set to be copied and saved all at once for all amplifiers connected together from the right side. This greatly reduces troublesome setup tasks and makes setup much smoother.In addition, troublesome adjustment operations at times such as when replacing sensors can also be carried out easily and data can also be Single copy & save operation for all amplifiers copied and stored using the optical communication function. The amplifier unit can be used as either a main unit or a sub unit. This feature allows for easy mounting in the side-by-side configuration. The main and sub unit functions are distinguished only by the proper use of the main cable and the sub cable. Moreover, inventory management and maintenance is simplified. Identical part numbers eliminate the need for costly inventory management labor * Use the optical communication function for only the same types of sensors. Furthermore, the FX-301-HS is not equipped with optical communication function capability. Settings can be entered directly using numerical input All models Sub cable FX-305 FX-301(-HS) FX-301B/G/H Main cable (4-core) CN-74-C Every function can be directly set merely by the input of a four digit code (numbers) from the code table. This convenient feature is easy to set up. In the event that settings are accidentally changed at the operating site, merely entering the correct code can restore the original settings. This results in easy and quick maintenance. First digit: Settings for response time and hysteresis Sub cable (2-core) CN-72-C Second digit: Settings for L/D ON and display mode Main cable (3-core) Main cable CN-73-C LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sub cable (1-core) CN-71-C Fourth digit: Timer period settings Third digit: Settings for Adjust lock and timer Communication unit improves equipment starting up and maintenance External input unit for digital sensor FX-CH2 Teaching and changing settings can be performed by using the PLC and touch panel. FX-301 FX-305 Upper communication unit for digital sensor SC-GU1-485 Fibers Amplifiers We now offer remote maintenance for digital sensors! Various settings and switching of up to 16 units of digital fiber sensors can be accomplished at once without operating the actual sensors themselves, but via external signals, such as the PLC, touch panel, and push buttons. The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching) to be carried out via a PLC or a personal computer, and also allows confirming of the incident light intensity an output status for the fiber sensors. This greatly improves workability during equipment starting up and maintenance.
* Batch teaching * Key lock setting * Batch loading / saving of the data bank * Sensor incident light intensity * Sensor settings verification * Sensor output status * Threshold value settings, etc. FX-301(P) FX-305(P) PLC Refer to our website for details Selection Guide Compatible with all PLCs equipped with RS-485 compatible units SC-GU1-485 RS-485 communication Refer to SC-GU1-485 pages for details FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 181 Amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately. Type MICRO PHOTOELECTRIC SENSORS Appearance Model No. FX-301 AREA SENSORS FX-301BP PNP open-collector transistor FX-301G NPN open-collector transistor NPN open-collector transistor FX-301HP High-speed type PNP open-collector transistor FX-301-HS NPN open-collector transistor FX-301P-HS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F CN-73-C2 2 m 6.562 ft CN-73-C5 5 m 16.404 ft CN-71-C1 1 m 3.281 ft CN-71-C2 2 m 6.562 ft CN-71-C5 5 m 16.404 ft CN-74-C1 1 m 3.281 ft CN-74-C2 2 m 6.562 ft CN-74-C5 5 m 16.404 ft CN-72-C1 1 m 3.281 ft CN-72-C2 2 m 6.562 ft CN-72-C5 5 m 16.404 ft PNP open-collector transistor PLC / TERMINALS FX-305 High-function type MACHINE VISION SYSTEMS 1 m 3.281 ft Red LED LASER MARKERS FA COMPONENTS CN-73-C1 PNP open-collector transistor Infrared LED MEASUREMENT SENSORS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Length Green LED FX-301H WIRE-SAVING SYSTEMS HUMAN MACHINE INTERFACES Model No. Main cable (3-core) Standard type NPN open-collector transistor Blue LED FX-301GP SIMPLE WIRE-SAVING UNITS ENDOSCOPE PNP open-collector transistor FX-301B SENSOR OPTIONS STATIC CONTROL DEVICES Quick-connection cables Type NPN open-collector transistor FX-301P PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS Output Red LED LIGHT CURTAINS INDUCTIVE PROXIMITY SENSORS Emitting element Sub cable (1-core) PHOTOELECTRIC SENSORS ORDER GUIDE Main cable (4-core) LASER SENSORS FX-300 SERIES Sub cable (2-core) FIBER SENSORS Digital Fiber Sensor NPN open-collector transistor Red LED FX-305P PNP open-collector transistor Digital Fiber Sensor FX-300 SERIES ORDER GUIDE 182 FIBER SENSORS Quick-connection cables LASER SENSORS For FX-301(-HS)/B/G/H Quick-connection cable is not supplied with the amplifier. Please order it separately. Main cable PHOTOELECTRIC SENSORS Type Main cable (3-core) Sub cable (1-core) Model No. CN-73-C1 Description Length: 1 m 3.281 ft CN-73-C5 0.15 mm2 3-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.0 mm o0.118 in Length: 5 m 16.404 ft CN-71-C1 Length: 1 m 3.281 ft CN-73-C2 CN-71-C2 CN-71-C5 MICRO PHOTOELECTRIC SENSORS * CN-73-C 0.15 mm2 1-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.0 mm o0.118 in Length: 5 m 16.404 ft AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS Sub cable INDUCTIVE PROXIMITY SENSORS * CN-71-C PARTICULAR USE SENSORS SENSOR OPTIONS For FX-305 Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Main cable (4-core) Sub cable (2-core) Model No. CN-74-C1 Description CN-74-C5 CN-72-C1 Length: 1 m 3.281 ft CN-72-C2 CN-72-C5 Main cable WIRE-SAVING SYSTEMS * CN-74-C MEASUREMENT SENSORS Length: 1 m 3.281 ft 0.15 mm2 4-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.0 mm o0.118 in Length: 5 m 16.404 ft CN-74-C2 SIMPLE WIRE-SAVING UNITS 0.15 mm2 2-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.0 mm o0.118 in Length: 5 m 16.404 ft STATIC CONTROL DEVICES ENDOSCOPE Sub cable LASER MARKERS * CN-72-C PLC / TERMINALS HUMAN MACHINE INTERFACES End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade. Appearance Model No. MS-DIN-E ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Description MACHINE VISION SYSTEMS When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. UV CURING SYSTEMS Two pcs. per set Selection Guide OPTIONS Fibers Amplifiers Amplifier mounting bracket Model No. Amplifier mounting bracket MS-DIN-2 Mounting bracket for amplifier FX-300 FX-410 FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quickconnection cable. Fiber amplifier protection seal Description FX-500 Designation Note: Fiber amplifier protection seals are supplied with the FX-301(P) and FX-305(P). * MS-DIN-2 FX-100 FX-311 FX-301-F7/ FX-301-F Fiber amplifier protection seal * FX-MB1 Communication window seal Connector seal 183 FIBER SENSORS Digital Fiber Sensor FX-300 SERIES LIST OF FIBERS LASER SENSORS FX-301 / FX-305 (Red LED type) sensing range (Note 1) PHOTOELECTRIC SENSORS Thru-beam type (one pair set) MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode) Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 2) Model No. Red LED U-LG FT-30 LONG STDF 210 8.268 STD 150 5.906 Dimensions FAST 450 17.717 310 12.205 110 4.331 FT-31 440 17.323 290 11.417 200 7.874 142 5.591 105 4.134 FT-40 1,300 51.181 900 35.433 600 23.622 450 17.717 330 12.992 FT-41 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 FT-42 1,100 43.307 800 31.496 550 21.654 400 15.748 285 11.220 FT-A8 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,300 129.921 1,500 59.055 1,100 43.307 FT-A30 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) H-SP S-D 60 2.362 P.90 58 2.283 49 1.929 P.90 180 7.087 180 7.087 P.90 150 5.906 130 5.118 P.90 160 6.299 150 5.906 P.90 1,080 42.520 750 29.528 P.90 3,000 118.110 3,500 137.795 (Note 3) P.90 60 2.362 FT-AFM2 850 33.465 650 25.591 380 14.961 330 12.992 220 8.661 100 3.937 115 4.528 P.90 FT-AFM2E 800 31.496 590 23.228 350 13.780 290 11.417 200 7.874 90 3.543 100 3.937 P.90 1,600 62.992 1,100 43.307 700 27.559 530 20.866 400 15.748 200 7.874 180 7.087 P.90 20 0.787 18 0.709 13 0.512 10 0.394 8 0.315 3 0.118 3 0.118 P.91 FT-B8 FT-E12 FT-E13 20 0.787 13 0.512 9 0.354 6 0.236 5 0.197 2 0.079 2 0.079 P.91 FT-E22 130 5.118 80 3.150 60 2.362 50 1.969 36 1.417 18 0.709 15 0.591 P.91 FT-E23 95 3.740 65 2.559 42 1.654 31 1.220 22 0.866 12 0.472 12 0.472 P.91 FT-FM2 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 150 5.906 130 5.118 P.91 FT-FM2S 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 150 5.906 130 5.118 P.91 FT-FM2S4 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 150 5.906 130 5.118 P.91 19,500 767.717 (Note 4) 19,500 767.717 (Note 4) 19,500 767.717 (Note 4) 14,000 551.180 10,000 393.700 3,500 137.795 3,800 149.606 P.91 FT-FM10L FT-H13-FM2 1,200 47.244 880 34.646 550 21.654 440 17.323 300 11.811 150 5.906 155 6.102 P.91 FT-H20-J20-S (Note 5) 530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.92 FT-H20-J30-S (Note 5) 530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.92 FT-H20-J50-S (Note 5) 530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.92 FT-H20-M1 750 29.528 550 21.654 320 12.598 280 11.024 200 7.874 85 3.346 90 3.543 P.92 FT-H20-VJ50-S (Note 5) 840 33.071 550 21.654 370 14.567 280 11.024 200 7.874 90 3.543 90 3.543 P.92 FT-H20-VJ80-S (Note 5) 840 33.071 550 21.654 370 14.567 280 11.024 200 7.874 90 3.543 90 3.543 P.92 FT-H20W-M1 420 16.535 310 12.205 180 7.087 140 5.512 100 3.937 40 1.575 50 1.969 P.92 FT-H30-M1V-S (Note 6) 350 13.780 250 9.843 150 5.906 125 4.921 90 3.543 50 1.969 40 1.575 P.92 FT-H35-M2 750 29.528 550 21.654 330 12.992 280 11.024 200 7.874 85 3.346 90 3.543 P.92 FT-H35-M2S6 750 29.528 550 21.654 330 12.992 280 11.024 200 7.874 85 3.346 90 3.543 P.92 FT-HL80Y FT-K8 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,000 118.110 2,000 78.740 1,800 70.866 1,350 53.150 900 35.433 450 17.717 480 18.898 P.92 1,500 59.055 1,000 39.370 800 31.496 300 11.811 350 13.780 P.93 FT-KV1 600 23.622 500 19.685 300 11.811 250 9.843 180 7.087 90 3.543 100 3.937 P.93 FT-KV8 3,000 118.110 2,000 78.740 1,500 59.055 1,000 39.370 800 31.496 300 11.811 350 13.780 P.93 FT-L80Y 3,500 137.795 3,500 137.795 2,000 78.740 1,500 59.055 1,000 39.370 500 19.685 530 20.866 P.93 FT-NFM2 400 15.748 270 10.630 200 7.874 140 5.512 100 3.937 55 2.165 49 1.929 P.93 FT-NFM2S 400 15.748 270 10.630 200 7.874 140 5.512 100 3.937 55 2.165 49 1.929 P.93 FT-NFM2S4 400 15.748 270 10.630 200 7.874 140 5.512 100 3.937 55 2.165 49 1.929 P.93 FT-P2 350 13.780 280 11.024 160 6.299 120 4.724 90 3.543 40 1.575 42 1.654 P.93 FT-P40 350 13.780 250 9.843 150 5.906 100 3.937 75 2.953 30 1.181 35 1.378 P.93 FT-P60 550 21.654 400 15.748 250 9.843 190 7.480 140 5.512 70 2.756 80 3.150 P.93 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long. 4) The fiber cable length practically limits the sensing range to 19,500 mm 767.717 in long. 5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. 6) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Digital Fiber Sensor FX-300 SERIES LIST OF FIBERS FIBER SENSORS FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode) Thru-beam type (one pair set) Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Red LED LONG STDF STD Dimensions FAST LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 2) Model No. U-LG 184 H-SP S-D FT-P80 900 35.433 650 25.591 400 15.748 320 12.598 230 9.055 100 3.937 110 4.331 P.93 FT-P81X 900 35.433 650 25.591 380 14.961 320 12.598 230 9.055 100 3.937 110 4.331 P.94 FT-PS1 100 3.937 80 3.150 50 1.969 40 1.575 30 1.181 13 0.512 17 0.669 P.93 FT-R80 740 29.134 530 20.866 320 12.598 230 9.055 150 5.906 75 2.953 80 3.150 P.94 FT-S20 450 17.717 310 12.205 210 8.268 150 5.906 110 4.331 60 2.362 60 2.362 P.94 FT-S21 440 17.323 290 11.417 200 7.874 142 5.591 105 4.134 58 2.283 49 1.929 P.94 FT-S30 1,300 51.181 900 35.433 600 23.622 450 17.717 330 12.992 180 7.087 180 7.087 P.94 FT-SFM2 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 150 5.906 130 5.118 P.94 FT-SFM2L AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 2,000 78.740 1,600 62.992 820 32.283 800 31.496 580 22.835 170 6.693 280 11.024 P.94 FT-SFM2SV2 550 21.654 400 15.748 240 9.449 200 7.874 140 5.512 65 2.559 70 2.756 P.94 FT-SNFM2 400 15.748 270 10.630 200 7.874 140 5.512 100 3.937 55 2.165 49 1.929 P.95 FT-T80 1,000 39.370 780 30.709 500 19.685 400 15.748 280 11.024 150 5.906 130 5.118 P.95 FT-V10 2,350 92.520 2,000 78.740 1,400 55.118 1,000 39.370 800 31.496 340 13.386 350 13.780 P.95 STATIC CONTROL DEVICES FT-V22 410 16.142 390 15.354 220 8.661 180 7.087 125 4.921 60 2.362 63 2.480 P.95 ENDOSCOPE FT-V41 220 8.661 175 6.890 100 3.937 80 3.150 60 2.362 25 0.984 27 1.063 P.95 1,000 39.370 800 31.496 500 19.685 400 15.748 280 11.024 120 4.724 140 5.512 P.95 FT-W4 220 8.661 160 6.299 100 3.937 80 3.150 55 2.165 25 0.984 28 1.102 P.95 FT-W8 750 29.528 570 22.441 350 13.780 290 11.417 200 7.874 90 3.543 100 3.937 P.95 FT-WA8 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,300 129.921 1,500 59.055 1,100 43.307 1,080 42.520 750 29.528 P.95 FT-WA30 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,000 118.110 3,500 137.795 (Note 3) P.95 FT-V80Y FT-WKV8 2,200 86.614 1,700 66.929 1,000 39.370 700 27.559 600 23.622 280 11.024 300 11.811 P.96 FT-WR80 750 29.528 570 22.441 350 13.780 290 11.417 200 7.874 90 3.543 100 3.937 P.96 1,500 59.055 1,200 47.244 750 29.528 600 23.622 420 16.535 200 7.874 210 8.268 P.96 FT-WS3 780 30.709 570 22.441 340 13.386 290 11.417 200 7.874 90 3.543 100 3.937 P.96 FT-WS4 220 8.661 160 6.299 100 3.937 80 3.150 55 2.165 25 0.984 28 1.102 P.96 FT-WR80L FT-WS8 750 29.528 570 22.441 350 13.780 290 11.417 200 7.874 90 3.543 100 3.937 P.96 FT-WS8L 1,500 59.055 1,200 47.244 750 29.528 600 23.622 420 16.535 200 7.874 210 8.268 P.96 FT-WV42 120 4.724 90 3.543 55 2.165 40 1.575 30 1.181 13 0.512 15 0.591 P.96 300 11.811 200 7.874 140 5.512 100 3.937 70 2.756 40 1.575 40 1.575 P.96 220 8.661 150 5.906 105 4.134 75 2.953 50 1.969 30 1.181 30 1.181 P.97 FT-WZ7 660 25.984 440 17.323 308 12.126 220 8.661 150 5.906 80 3.150 80 3.150 P.97 FT-WZ7HB 870 34.252 580 22.835 406 15.984 290 11.417 210 8.268 110 4.331 110 4.331 P.97 FT-WZ8 950 37.402 700 27.559 420 16.535 330 12.992 240 9.449 100 3.937 120 4.724 P.97 FT-WZ8E 2,100 82.677 1,500 59.055 950 37.402 700 27.559 500 19.685 200 7.874 210 8.268 P.97 FT-WZ8H 3,500 137.795 2,500 98.425 1,600 62.992 1,200 47.244 850 33.465 400 15.748 410 16.142 P.97 1,100 43.307 800 31.496 500 19.685 400 15.748 300 11.811 120 4.724 140 5.512 P.97 FT-WZ4 FT-WZ4HB FT-Z8 FT-Z8E 1,850 72.835 1,600 62.992 950 37.402 800 31.496 600 23.622 250 9.843 280 11.024 P.97 FT-Z8H 3,100 122.047 2,700 106.299 1,550 61.024 1,400 55.118 1,000 39.370 420 16.535 490 19.291 P.97 FT-Z802Y 3,500 137.795 3,500 137.795 3,000 118.110 1,500 59.055 1,000 39.370 500 19.685 530 20.866 P.97 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 185 FIBER SENSORS Digital Fiber Sensor FX-300 SERIES LIST OF FIBERS LASER SENSORS FX-301 / FX-305 (Red LED type) sensing range (Note 1) PHOTOELECTRIC SENSORS Retroreflective type MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 2, 3) HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 Red LED Model No. U-LG FR-KV1 LONG STDF STD Dimensions FAST H-SP S-D 15 to 370 0.591 to 14.567 15 to 330 0.591 to 12.992 15 to 240 0.591 to 9.449 15 to 210 0.591 to 8.268 15 to 170 0.591 to 6.693 15 to 80 0.591 to 3.150 15 to 90 0.591 to 3.543 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 P.98 FR-KZ21E 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 P.98 FR-WKZ11 100 to 910 3.937 to 35.827 100 to 730 3.937 to 28.740 100 to 600 3.937 to 23.622 100 to 520 3.937 to 20.472 100 to 460 3.937 to 18.110 - - P.98 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21 and FR-KZ21E is specified for the attached reflector RF-003. The sensing range of FR-KV1 is specified for the attached reflector. 3) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode) Reflective type Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 2, 3) Model No. Red LED U-LG FD-30 FD-31 FD-40 FD-41 FD-60 FD-61 FD-A15 FD-AFM2 FD-AFM2E FD-B8 FD-E12 FD-E22 FD-EG1 FD-EG2 FD-EG3 FD-EN500S1 FD-ENM1S1 170 6.693 150 5.906 170 6.693 150 5.906 500 19.685 440 17.323 230 9.055 290 11.417 290 11.417 600 23.622 15 0.591 65 2.559 50 1.969 40 1.575 20 0.787 6.5 0.256 50 1.969 LONG 110 4.331 95 3.740 110 4.331 95 3.740 350 13.780 320 12.598 200 7.874 220 8.661 220 8.661 480 18.898 11 0.433 45 1.772 38 1.496 25 0.984 15 0.591 5 0.197 38 1.496 STDF 70 2.756 63 2.480 70 2.756 63 2.480 240 9.449 205 8.071 150 5.906 135 5.315 135 5.315 280 11.024 8 0.315 28 1.102 25 0.984 14 0.551 9 0.354 3 0.118 20 0.787 STD 50 1.969 45 1.772 50 1.969 45 1.772 160 6.299 145 5.709 150 5.906 110 4.331 110 4.331 220 8.661 6 0.236 23 0.906 18 0.709 12 0.472 8 0.315 3 0.118 18 0.709 Dimensions FAST 40 1.575 35 1.378 40 1.575 35 1.378 130 5.118 105 4.134 100 3.937 78 3.071 78 3.071 160 6.299 4 0.157 17 0.669 14 0.551 9 0.354 5 0.197 2 0.079 14 0.551 H-SP 20 0.787 17 0.669 20 0.787 17 0.669 70 2.756 65 2.559 45 1.772 35 1.378 35 1.378 85 3.346 2 0.079 8 0.315 5 0.197 3 0.118 2.5 0.098 Cannot use 5 0.197 S-D 18 0.709 16 0.630 18 0.709 16 0.630 70 2.756 60 2.362 50 1.969 39 1.535 39 1.535 75 2.953 1 0.039 7 0.276 6 0.236 5 0.197 3 0.118 Cannot use 6 0.236 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.100 P.100 P.100 P.100 P.100 P.100 P.100 FD-F4 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] P.100 FD-F41 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] P.100 FD-F41Y o4 mm o0.157 in form Protective tube: fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted - - - - - - - P.101 P.101 P.101 P.101 P.101 P.101 P.102 P.102 P.101 P.102 P.102 P.102 FX-300 FD-F8Y FX-410 FD-FA90 Applicable pipe diameter: Outer dia. o8 mm o0.315 in or more transparent pipe (When used with the tying bands: o8 to o80 mm o0.315 to o3.150 in) [PFA (fluorine resin), including translucent] Liquid absent: Beam received, Liquid present: Beam interrupted FX-311 FD-FM2 FD-FM2S FD-FM2S4 FD-G4 FD-G6 FD-G6X FD-G40 FD-G60 FD-H13-FM2 FD-H18-L31 410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 370 14.567 270 10.630 170 6.693 110 4.331 85 3.346 370 14.567 270 10.630 170 6.693 110 4.331 85 3.346 150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 150 5.906 90 3.543 48 1.890 45 1.772 35 1.378 150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394 1 to 8 0.039 to 0.315 FX-301-F7/ FX-301-F P.98 FR-KZ21 LASER MARKERS PLC / TERMINALS The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode) 55 2.165 47 1.850 45 1.772 39 1.535 45 1.772 39 1.535 15 0.591 19 0.748 15 0.591 19 0.748 12 0.472 20 0.787 15 0.591 19 0.748 55 2.165 47 1.850 55 2.165 47 1.850 Cannot use 2 to 6 0.079 to 0.236 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode. 2) The standard sensing objects of the sensing ranges vary depending on the fibers. 3) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. P.101 Digital Fiber Sensor FX-300 SERIES LIST OF FIBERS FIBER SENSORS FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode) Reflective type Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Red LED U-LG FD-HF40Y FD-L4 FD-L41 LONG STDF STD Dimensions FAST LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 2, 3) Model No. FD-H20-21 FD-H20-M1 FD-H25-L43 FD-H25-L45 FD-H30-KZ1V-S (Note 4) FD-H30-L32 FD-H30-L32V-S (Note 4) FD-H35-20S FD-H35-M2 FD-H35-M2S6 186 H-SP S-D 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 3 to 28 0.118 to 1.102 3 to 25 0.118 to 0.984 4 to 23 0.157 to 0.906 4 to 20 0.118 to 0.787 4 to 19 0.118 to 0.748 4 to 16 0.118 to 0.630 4 to 16 0.118 to 0.630 - - - 5 to 42 0.197 to 1.654 6 to 41 0.236 to 1.614 6 to 40 0.236 to 1.575 7 to 38 0.276 to 1.496 20 to 300 0.787 to 11.811 20 to 200 0.787 to 7.874 20 to 150 0.787 to 5.906 25 to 130 0.984 to 5.118 30 to 100 1.181 to 3.937 Cannot use Cannot use 0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394 1 to 8 0.039 to 0.315 Cannot use 2 to 6 0.079 to 0.236 0 to 11 0 to 0.433 0 to 8 0 to 0.315 1.5 to 6 0.059 to 0.236 1.5 to 5 0.059 to 0.197 2 to 4 0.079 to 0.157 Cannot use Cannot use 190 7.480 160 6.299 80 3.150 80 3.150 57 2.244 20 0.787 26 1.024 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 o4 mm o0.157 in form Protective tube: fluorine resin, length:500 mm 19.685 in (allowable cutting) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted 2 to 20 0.079 to 0.787 2.5 to 18 0.098 to 0.709 4 to 12 0.157 to 0.472 4 to 12 0.157 to 0.472 4.5 to 11 0.177 to 0.433 5 to 8.5 0.197 to 0.335 4.8 to 9.5 0.189 to 0.374 (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) 2 to 19 0.079 to 0.748 2.5 to 18 0.098 to 0.709 3 to 16 0.118 to 0.630 3 to 16 0.118 to 0.630 3.5 to 15 0.138 to 0.591 Cannot use Cannot use (Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315) P.102 P.102 P.103 P.103 P.103 P.103 P.103 P.104 P.104 P.104 AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS P.104 SIMPLE WIRE-SAVING UNITS P.104 WIRE-SAVING SYSTEMS P.104 MEASUREMENT SENSORS - - - - - 0 to 7 0 to 0.276 0 to 4.5 0 to 0.177 0 to 36 0 to 1.417 10 to 33 0.394 to 1.299 (Note 5) 0 to 6.5 0 to 0.256 0 to 4 0 to 0.157 0 to 33 0 to 1.299 10 to 32 0.394 to 1.260 (Note 5) 0 to 23 0 to 0.906 0 to 6 0 to 0.236 0 to 4 0 to 0.157 0 to 30 0 to 1.181 10 to 32 0.394 to 1.260 (Note 5) - 0 to 8.2 0 to 0.323 0 to 4.7 0 to 0.185 0 to 50 0 to 1.969 10 to 33 0.394 to 1.299 (Note 5) 0 to 5.7 0 to 0.224 0 to 3.8 0 to 0.150 0 to 30 0 to 1.181 10 to 32 0.394 to 1.260 (Note 5) 0 to 5 0 to 0.197 0 to 3 0 to 0.118 0 to 15 0 to 0.591 13 to 18 0.512 to 0.709 (Note 5) 0 to 5.2 0 to 0.205 0 to 3.5 0 to 0.138 0 to 21 0 to 0.827 13 to 18 0.512 to 0.709 (Note 5) 12.5 to 37.5 0.492 to 1.476 30 1.181 90 3.543 90 3.543 90 3.543 50 1.969 36 1.417 90 3.543 90 3.543 220 8.661 185 7.283 185 7.283 110 4.331 95 3.740 270 10.630 100 3.937 90 3.543 90 3.543 270 10.630 55 2.165 190 7.480 30 1.181 65 2.559 20 to 480 0.787 to 18.898 6.5 to 14 0.256 to 0.551 (Convergent point 8 0.315) 15 to 36 0.591 to 1.417 30 1.181 60 2.362 60 2.362 60 2.362 30 1.181 20 0.787 55 2.165 55 2.165 130 5.118 100 3.937 110 4.331 70 2.756 63 2.480 170 6.693 55 2.165 60 2.362 60 2.362 170 6.693 30 1.181 110 4.331 18 0.709 37 1.457 20 to 300 0.787 to 11.811 7 to 14 0.276 to 0.551 (Convergent point 8 0.315) 15 to 35 0.591 to 1.378 30 1.181 45 1.772 45 1.772 45 1.772 25 0.984 18 0.709 45 1.772 45 1.772 100 3.937 80 3.150 85 3.346 50 1.969 45 1.772 110 4.331 45 1.772 45 1.772 45 1.772 110 4.331 25 0.984 90 3.543 15 0.591 32 1.260 20 to 230 0.787 to 9.055 7 to 12 0.276 to 0.472 (Convergent point 8 0.315) 16 to 29 0.630 to 1.142 Cannot use Cannot use 1 to 28 0.039 to 1.102 2 to 27 0.079 to 1.063 2 to 27 0.079 to 1.063 35 1.378 16 0.630 16 0.630 35 1.378 16 0.630 16 0.630 35 1.378 16 0.630 16 0.630 19 0.748 7.5 0.295 9 0.354 14 0.551 5.5 0.217 6 0.236 30 1.181 13 0.512 16 0.630 30 1.181 13 0.512 16 0.630 70 2.756 30 1.181 35 1.378 60 2.362 30 1.181 35 1.378 60 2.362 25 0.984 30 1.181 40 1.575 20 0.787 18 0.709 35 1.378 17 0.669 16 0.630 85 3.346 45 1.772 39 1.535 32 1.260 15 0.591 16 0.630 35 1.378 16 0.630 16 0.630 35 1.378 16 0.630 16 0.630 85 3.346 45 1.772 39 1.535 17 0.669 8 0.315 9 0.354 60 2.362 25 0.984 32 1.260 12 0.472 4.5 0.177 5 0.197 25 0.984 10 0.394 11 0.433 20 to 170 0.787 to 6.693 25 to 90 0.984 to 3.543 25 to 100 0.984 to 3.937 7.5 to 12 0.295 to0.472 Cannot use Cannot use (Convergent point 8 0.315) P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.106 P.106 P.106 P.106 P.106 P.106 P.106 P.106 P.106 P.106 P.107 P.107 P.107 P.107 FD-WL41 12 to 50 0.472 to 1.969 30 1.181 140 5.512 140 5.512 140 5.512 80 3.150 50 1.969 130 5.118 130 5.118 300 11.811 270 10.630 240 9.449 170 6.693 150 5.906 370 14.567 170 6.693 140 5.512 140 5.512 370 14.567 80 3.150 250 9.843 40 1.575 85 3.346 20 to 660 0.787 to 25.984 6.5 to 14.5 0.256 to 0.571 (Convergent point 8 0.315) P.107 FX-300 FD-WL48 FD-WS8 FD-WSG4 FD-WT4 FD-WT8 FD-WV42 FD-WZ4 FD-WZ4HB FD-WZ7 FD-WZ7HB 0.5 to 8.5 0.020 to 0.335 250 9.843 85 3.346 40 1.575 250 9.843 20 0.787 1 to 50 0.039 to 1.969 1 to 70 0.039 to 2.756 200 7.874 0.5 to 270 0.020 to 10.630 0.5 to 7.5 0.020 to 0.295 190 7.480 65 2.559 30 1.181 190 7.480 15 0.591 1.5 to 34 0.059 to 1.339 1 to 46 0.039 to 1.811 120 4.724 0.5 to 180 0.020 to 7.087 1 to 6.5 0.039 to 0.256 110 4.331 37 1.457 18 0.709 110 4.331 8.5 0.335 2 to 24 0.079 to 0.945 1 to 32.2 0.039 to 1.268 1 to 84 0.039 to 3.307 1 to 126 0.039 to 4.961 1 to 5.5 0.039 to 0.217 90 3.543 32 1.260 15 0.591 90 3.543 7 0.276 3 to 17 0.118 to 0.669 2.5 to 23 0.098 to 0.906 1 to 60 0.039 to 2.362 1 to 90 0.039 to 3.543 1 to 5 0.039 to 0.197 Cannot use Cannot use 60 2.362 25 0.984 32 1.260 25 0.984 10 0.394 11 0.433 12 0.472 4.5 0.177 5 0.197 60 2.362 25 0.984 32 1.260 5 0.197 Cannot use Cannot use - - 3 to 10 0.118 to 0.394 2.5 to 15 0.098 to 0.591 3 to 7 0.118 to 0.276 3 to 7 0.118 to 0.276 1.5 to 35 0.059 to 1.378 2.5 to 18 0.098 to 0.709 2.5 to 18 0.098 to 0.709 1 to 70 0.039 to 2.756 1 to 35 0.039 to 1.378 1 to 35 0.039 to 1.378 P.107 P.107 P.107 P.107 P.107 P.108 P.108 P.108 P.108 P.108 FX-410 FD-L43 FD-L44 FD-L44S FD-L45 FD-L45A FD-L46 FD-L47 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-P2 FD-P40 FD-P50 FD-P60 FD-P80 FD-P81X FD-R80 FD-S30 FD-S31 FD-S80 FD-SFM2SV2 FD-SNFM2 FD-T40 FD-T80 FD-V41 FD-W8 FD-W44 FD-WG4 FD-WKZ1 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode. 2) The standard sensing objects of the sensing ranges vary depending on the fibers. 3) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 5) Sensing distance varies depending on the sensing object's inclination. P.104 P.104 P.104 P.104 STATIC CONTROL DEVICES ENDOSCOPE P.105 LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-311 FX-301-F7/ FX-301-F 187 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers Digital Fiber Sensor FX-300 SERIES SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED Thru-beam type (One pair set) Fibers are listed in alphabetic order. Refer to p.5~ for details of each fiber. Sensing range (mm in) (Note 1) FX-301B Model No. LONG FT-30 55 2.165 STD 28 1.102 FX-301G FAST 18 0.709 LONG 28 1.102 STD 13 0.512 FX-301H (Note 2) FAST 9 0.354 LONG 25 0.984 STD 13 0.512 Dimensions FAST 9 0.354 P.90 FT-31 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 23 0.906 11 0.433 8 0.315 P.90 FT-40 155 6.102 76 2.992 45 1.772 90 3.543 40 1.575 26 1.024 80 3.150 43 1.693 27 1.063 P.90 FT-41 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 50 1.969 25 0.984 18 0.709 P.90 FT-42 150 5.906 75 2.953 40 1.575 80 3.150 35 1.378 24 0.945 75 2.953 40 1.575 25 0.984 P.90 FT-A8 600 23.622 300 11.811 220 8.661 300 11.811 150 5.906 110 4.331 220 8.661 110 4.331 80 3.150 P.90 FT-A30 2,400 94.488 1,200 47.244 700 27.559 1,200 47.244 600 23.622 350 13.780 800 31.496 400 15.748 240 9.449 P.90 FT-AFM2 120 4.724 60 2.362 40 1.575 60 2.362 30 1.181 20 0.787 48 1.890 24 0.945 18 0.709 P.90 FT-AFM2E 120 4.724 60 2.362 40 1.575 60 2.362 30 1.181 20 0.787 48 1.890 24 0.945 18 0.709 P.90 FT-B8 220 8.661 110 4.331 75 2.953 110 4.331 40 1.575 30 1.181 P.90 100 3.937 50 1.969 1 0.039 - 55 2.165 - 4 0.157 2 0.079 1 0.039 - - 2 0.079 1 0.039 FT-E12 3 0.118 2 0.079 FT-E13 2 0.079 1 0.039 FT-E22 14 0.551 7 0.276 4 0.157 6 0.236 3 0.118 2 0.079 10 0.394 5 0.197 3 0.118 P.91 FT-E23 8 0.315 4 0.157 3 0.118 4 0.157 2 0.079 1 0.039 10 0.394 5 0.197 3 0.118 P.91 FT-FM2 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 50 1.969 25 0.984 18 0.709 P.91 FT-FM2S 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 50 1.969 25 0.984 18 0.709 P.91 24 0.945 50 1.969 25 0.984 18 0.709 P.91 1,000 39.370 2,400 94.488 (Note 3) 1,200 47.244 (Note 3) 900 35.433 (Note 3) P.91 1 0.039 - 1.5 0.059 - P.91 P.91 FT-FM2S4 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 FT-FM10L 5,400 212.598 2,700 106.299 1,900 74.803 2,800 110.236 1,400 55.118 FT-H13-FM2 72 2.835 36 1.417 FT-H20-J20-S (Note 4) 60 2.362 20 0.787 - 35 1.378 - - 20 0.787 - - P.92 FT-H20-J30-S (Note 4) 60 2.362 20 0.787 - 35 1.378 - - 20 0.787 - - P.92 60 2.362 20 0.787 - 35 1.378 - - 20 0.787 - - P.92 100 3.937 50 1.969 FT-H20-J50-S (Note 4) FT-H20-M1 26 1.024 35 1.378 32 1.260 50 1.969 16 0.630 25 0.984 10 0.394 18 0.709 - P.92 85 3.346 30 1.181 85 3.346 30 1.181 - FT-H20W-M1 44 1.732 22 0.866 FT-H30-M1V-S (Note 5) 40 1.575 20 0.787 FT-H35-M2 100 3.937 50 1.969 35 1.378 50 1.969 25 0.984 18 0.709 550 21.654 280 11.024 160 6.299 P.92 FT-H35-M2S6 100 3.937 50 1.969 35 1.378 50 1.969 25 0.984 18 0.709 550 21.654 280 11.024 160 6.299 P.92 FT-K8 - 160 6.299 P.91 FT-H20-VJ80-S (Note 4) FT-HL80Y 50 1.969 280 11.024 25 0.984 FT-H20-VJ50-S (Note 4) 14 0.551 - 550 21.654 35 1.378 - - 50 1.969 - 70 2.756 22 0.866 20 0.787 11 0.433 - 7 0.276 - 30 1.181 - - P.92 30 1.181 - - P.92 220 8.661 20 0.787 100 3.937 - 70 2.756 - P.92 P.92 80 3.150 40 1.575 25 0.984 110 4.331 55 2.165 40 1.575 1,100 43.307 550 21.654 350 13.780 P.92 400 15.748 200 7.874 130 5.118 200 7.874 100 3.937 65 2.559 150 5.906 75 2.953 40 1.575 P.93 - - - - - - FX-500 FT-KV1 80 3.150 35 1.378 10 0.394 FX-100 FT-KV8 400 15.748 200 7.874 130 5.118 200 7.874 100 3.937 65 2.559 150 5.906 75 2.953 40 1.575 P.93 FX-300 FT-L80Y 160 6.299 80 3.150 50 1.969 160 6.299 80 3.150 50 1.969 400 15.748 200 7.874 150 5.906 P.93 FX-410 FT-NFM2 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 16 0.630 8 0.315 5 0.197 P.93 FX-311 FT-NFM2S 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 16 0.630 8 0.315 5 0.197 P.93 FT-NFM2S4 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 16 0.630 8 0.315 5 0.197 P.93 FT-P2 36 1.417 18 0.709 14 0.551 20 0.787 10 0.394 8 0.315 18 0.709 9 0.354 7 0.276 P.93 FT-P40 32 1.260 13 0.512 12 0.472 18 0.709 9 0.354 7 0.276 14 0.551 7 0.276 5 0.197 P.93 FT-P60 50 1.969 25 0.984 18 0.709 26 1.024 13 0.512 8 0.315 20 0.787 10 0.394 7 0.276 P.93 FX-301-F7/ FX-301-F P.93 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with varying humidity. 3) Sensing range when fiber length is 2 m 6.562 ft. When fiber length is 10 m 32.81 ft, the beam attenuates and cannot be used. 4) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. 5) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Digital Fiber Sensor FX-300 SERIES SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED 188 FIBER SENSORS LASER SENSORS Thru-beam type (One pair set) Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 1) MICRO PHOTOELECTRIC SENSORS FX-301B Model No. FX-301G FAST LONG STD FX-301H (Note 2) FAST LONG STD Dimensions LONG STD FAST FT-P80 130 5.118 65 2.559 45 1.772 70 2.756 35 1.378 25 0.984 56 2.205 28 1.102 20 0.787 P.93 FT-P81X 130 5.118 64 2.520 45 1.772 64 2.520 32 1.260 25 0.984 56 2.205 28 1.102 20 0.787 P.94 FT-PS1 14 0.551 7 0.276 4 0.157 6 0.236 3 0.118 2 0.079 14 0.551 7 0.276 4 0.157 P.93 FT-R80 85 3.346 42 1.654 28 1.102 44 1.732 22 0.866 16 0.630 32 1.260 16 0.630 12 0.472 P.94 FT-S20 55 2.165 28 1.102 18 0.709 28 1.102 13 0.512 9 0.354 25 0.984 13 0.512 9 0.354 P.94 FT-S21 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 23 0.906 11 0.433 8 0.315 P.94 FT-S30 155 6.102 76 2.992 45 1.772 90 3.543 40 1.575 26 1.024 80 3.150 43 1.693 27 1.063 P.94 FT-SFM2 FT-SFM2L FT-SFM2SV2 FT-SNFM2 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 50 1.969 25 0.984 18 0.709 P.94 400 15.748 200 7.874 130 5.118 200 7.874 100 3.937 65 2.559 155 6.102 77 3.031 55 2.165 P.94 80 3.150 40 1.575 28 1.102 40 1.575 20 0.787 14 0.551 30 1.181 15 0.591 12 0.472 P.94 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 8 0.315 16 0.630 8 0.315 5 0.197 P.95 FT-T80 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 50 1.969 25 0.984 18 0.709 P.95 FT-V10 400 15.748 200 7.874 130 5.118 200 7.874 100 3.937 65 2.559 150 5.906 75 2.953 40 1.575 P.95 FT-V22 50 1.969 25 0.984 16 0.630 26 1.024 13 0.512 8 0.315 44 1.732 22 0.866 15 0.591 P.95 FT-V41 28 1.102 14 0.551 10 0.394 14 0.551 7 0.276 5 0.197 10 0.394 5 0.197 3 0.118 P.95 120 4.724 60 2.362 35 1.378 80 3.150 40 1.575 25 0.984 75 2.953 38 1.496 24 0.945 P.95 FT-V80Y FT-W4 16 0.630 8 0.315 5 0.197 10 0.394 5 0.197 3 0.118 8 0.315 4 0.157 2.5 0.098 P.95 FT-W8 90 3.543 45 1.772 30 1.181 56 2.205 28 1.102 20 0.787 42 1.654 21 0.827 15 0.591 P.95 FT-WA8 600 23.622 300 11.811 220 8.661 300 11.811 150 5.906 110 4.331 220 8.661 110 4.331 80 3.150 P.95 FT-WA30 2,400 94.488 1,200 47.244 700 27.560 1,200 47.244 600 23.622 350 13.780 800 31.496 400 15.748 240 9.449 P.95 FT-WKV8 300 11.811 150 5.906 100 3.937 160 6.299 80 3.150 60 2.362 150 5.906 75 2.953 45 1.772 P.96 FT-WR80 90 3.543 45 1.772 30 1.181 56 2.205 28 1.102 20 0.787 48 1.890 22 0.866 14 0.551 P.96 240 9.449 120 4.724 90 3.543 120 4.724 60 2.362 40 1.575 42 1.654 P.96 FT-WR80L FT-WS3 90 3.543 45 1.772 30 1.181 56 2.205 28 1.102 20 0.787 FT-WS4 16 0.630 8 0.315 5 0.197 10 0.394 5 0.197 3 0.118 FT-WS8 FT-WS8L FT-WV42 132 5.197 - 8 0.315 65 2.559 - 4 0.157 - 2.5 0.098 P.96 P.96 90 3.543 45 1.772 30 1.181 56 2.205 28 1.102 20 0.787 42 1.654 21 0.827 15 0.591 P.96 240 9.449 120 4.724 90 3.543 120 4.724 60 2.362 40 1.575 110 4.331 55 2.165 35 1.378 P.96 - - - - - - - - - P.96 AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide FT-WZ4 35 1.378 15 0.591 9 0.354 18 0.709 8 0.315 4.8 0.189 43 1.693 15 0.591 9 0.354 P.96 FT-WZ4HB 32 1.260 15 0.591 9.6 0.378 16 0.630 9 0.354 5.4 0.213 40 1.575 15 0.591 12 0.472 P.97 FT-WZ7 80 3.150 40 1.575 24 0.945 54 2.216 27 1.063 16.2 0.638 54 2.126 27 1.063 16.2 0.638 P.97 100 3.937 50 1.969 30 1.181 56 2.205 28 1.102 16.8 0.661 56 2.205 28 1.102 16.8 0.661 P.97 FX-500 80 3.150 40 1.575 25 0.984 40 1.575 20 0.787 13 0.512 36 1.417 18 0.709 12 0.472 P.97 FX-100 FT-WZ8E 240 9.449 120 4.724 80 3.150 120 4.724 60 2.362 40 1.575 100 3.937 50 1.969 30 1.181 P.97 FX-300 FT-WZ8H 400 15.748 200 7.874 140 5.512 200 7.874 100 3.937 70 2.756 180 7.087 90 3.543 65 2.559 P.97 FX-410 120 4.724 60 2.362 40 1.575 60 2.362 30 1.181 22 0.866 46 1.811 23 0.906 16 0.630 P.97 FX-311 FT-Z8E 400 15.748 200 7.874 140 5.512 200 7.874 100 3.937 65 2.559 140 5.512 70 2.756 50 1.969 P.97 FT-Z8H 560 22.047 280 11.024 200 7.874 200 7.874 100 3.937 65 2.559 180 7.087 90 3.543 65 2.559 P.97 FT-Z802Y 320 12.598 160 6.299 120 4.724 160 6.299 80 3.150 60 2.362 320 12.598 160 6.299 120 4.724 P.97 FT-WZ7HB FT-WZ8 FT-Z8 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with varying humidity. Fibers Amplifiers FX-301-F7/ FX-301-F 189 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Digital Fiber Sensor FX-300 SERIES SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED Retroreflective type Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 1, 2) FX-301B Model No. FR-KV1 FX-301G FX-301H LONG STD FAST LONG STD FAST LONG STD FAST - - - - - - - - - P.98 20 to 70 0.787 to 2.756 - P.98 20 to 90 0.787 to 3.543 - - P.98 100 to 340 3.937 to 13.386 - - P.98 FR-KZ21 20 to 200 0.787 to 7.874 20 to 120 0.787 to 4.724 20 to 90 0.787 to 3.543 20 to 130 0.787 to 5.118 20 to 80 0.787 to 3.150 FR-KZ21E 20 to 160 0.787 to 6.299 20 to 100 0.787 to 3.937 20 to 60 0.787 to 2.362 20 to 110 0.787 to 4.331 - - - - FR-WKZ11 Dimensions - - - - 20 to 50 0.787 to 1.969 20 to 130 0.787 to 5.118 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Reflective type Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 1, 2) FX-301B Model No. LONG FD-30 FD-31 FD-40 FD-41 FD-60 FD-61 FD-A15 FD-AFM2 FD-AFM2E FD-B8 FD-E12 FD-E22 FD-EG1 FD-EG2 FD-EG3 FD-EN500S1 FD-ENM1S1 FD-F4 FD-F41 FD-F41Y FD-F8Y FD-FA90 FD-FM2 FD-FM2S FD-FM2S4 FD-G4 FD-G6 FD-G6X FD-G40 FD-G60 FD-H13-FM2 FD-H18-L31 FD-H20-21 FD-H20-M1 STD FX-301G FAST LONG FX-301H STD FAST LONG STD Dimensions FAST 19 0.748 9 0.354 6 0.236 9 0.354 4.5 0.177 2.5 0.098 8 0.315 4 0.157 2.5 0.098 P.99 18 0.709 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 7 0.276 3 0.118 2 0.079 P.99 19 0.748 9 0.354 6 0.236 9 0.354 4.5 0.177 2.5 0.098 8 0.315 4 0.157 2.5 0.098 P.99 18 0.709 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 7 0.276 3 0.118 2 0.079 P.99 55 2.165 28 1.102 18 0.709 30 1.181 15 0.591 10 0.394 30 1.181 15 0.591 10 0.394 P.99 48 1.890 24 0.945 16 0.630 26 1.024 13 0.512 8 0.315 27 1.063 12 0.472 8 0.315 25 0.984 15 0.591 40 1.575 20 0.787 13 0.512 18 0.709 9 0.354 5 0.197 12 0.472 6 0.236 4 0.157 P.99 40 1.575 20 0.787 13 0.512 18 0.709 9 0.354 5 0.197 12 0.472 6 0.236 4 0.157 P.99 80 3.150 40 1.575 26 1.024 42 1.654 21 0.827 14 0.551 26 1.024 13 0.512 9 0.354 2 0.079 1 0.039 6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 6 0.236 3 0.118 2 0.079 6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 10 0.394 5 0.197 3 0.118 P.100 5 0.197 2 0.079 1 0.039 2 0.079 1 0.039 6 0.236 3 0.118 2 0.079 P.100 2 0.079 - 1 0.039 - - - - - - 1 0.039 1 0.039 - - - - - - - - - - - 1 0.039 3 0.118 - - - 1.5 0.059 - - - 1 0.039 - 6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 4 0.157 2 0.079 1.5 0.059 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] o4 mm o0.157 in form Protective tube: fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted - - - - - - - - - Applicable pipe diameter: Outer dia. o8 mm o0.315 in or more transparent pipe (When used with the tying bands: o8 to o80 mm o0.315 to o3.150 in) [PFA (fluorine resin), including translucent] Liquid absent: Beam received, Liquid present: Beam interrupted 46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 4 0.157 7 0.276 22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 4 0.157 7 0.276 33 1.299 11 0.433 6 0.236 12 0.472 6 0.236 4 0.157 22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 46 1.811 23 0.906 15 0.591 24 0.945 20 0.787 11 0.433 7 0.276 20 0.787 - - - - P.99 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.101 P.101 P.101 P.101 7 0.276 P.101 10 0.394 7 0.276 P.101 3.5 0.138 2 0.079 P.101 3.5 0.138 2 0.079 P.102 7 0.276 3.5 0.138 2 0.079 P.102 4 0.157 7 0.276 3.5 0.138 2 0.079 P.101 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 P.102 11 0.433 7 0.276 25 0.984 12 0.472 8 0.315 - - - 10 0.394 P.99 P.99 - - P.102 P.102 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 P.102 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 P.102 Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Digital Fiber Sensor FX-300 SERIES SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED FIBER SENSORS Reflective type LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 1, 2) FX-301B Model No. LONG - FD-H25-L43 - FD-H25-L45 FD-H30-KZ1V-S (Note 3) 30 to 40 1.181 to 1.575 - FD-H30-L32 - FD-H30-L32V-S (Note 3) 22 0.866 FD-H35-20S 36 1.417 FD-H35-M2 36 1.417 FD-H35-M2S6 FD-HF40Y FD-L4 FD-L41 FD-L43 FD-L44 FD-L44S FD-L45 FD-L45A FD-L46 FD-L47 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-P2 FD-P40 FD-P50 FD-P60 FD-P80 FD-P81X FD-R80 FD-S30 FD-S31 FD-S80 FD-SFM2SV2 FD-SNFM2 FD-T40 FD-T80 FD-V41 FD-W8 FD-W44 FD-WG4 FD-WKZ1 FD-WL41 FD-WL48 FD-WS8 FD-WSG4 FD-WT4 FD-WT8 FD-WV42 FD-WZ4 FD-WZ4HB FD-WZ7 FD-WZ7HB 190 FX-301G FX-301H Dimensions STD FAST LONG STD FAST LONG STD FAST - - - - - - - - P.103 - - - - - - - - P.103 - - - - - - - - P.103 - - - - - - - - P.103 - - - - - - - - P.103 11 0.433 7 0.276 12 0.472 6 0.236 4 0.157 80 3.150 40 1.575 28 1.102 P.104 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 P.104 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 o4 mm o0.157 in form Protective tube: fluorine resin, length:500 mm 19.685 in (allowable cutting) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted 4.5 to 9.5 0.177 to 0.374 5 to 9 0.197 to 0.354 5.5 to 8 0.217 to 0.315 5 to 9 0.197 to 0.354 5.5 to 8 0.217 to 0.315 - 4.5 to 9.5 0.177 to 0.374 - - (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) - - - - - - - - - P.104 - - - - - - - P.104 - - P.104 - - 1 to 4.3 0.039 to 0.169 - - P.104 - - - - - - P.104 - - - - - - P.105 - - - - - - - P.105 - - - - - - - P.105 - 1 to 3 0.039 to 0.118 - - - - - - - - - - INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS P.104 - 1 to 3 0.039 to 0.118 PRESSURE / FLOW SENSORS P.104 1 to 4.3 0.039 to 0.169 0 to 3.5 0 to 0.138 LIGHT CURTAINS SENSOR OPTIONS - 1 to 4.5 0.039 to 0.177 1.5 to 3.8 0.059 to 0.150 1 to 4.6 0.039 to 0.181 2.5 to 3 0.098 to 0.118 AREA SENSORS P.104 - 0 to 5.7 0 to 0.224 MICRO PHOTOELECTRIC SENSORS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE 16 0.630 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 6 0.236 3 0.118 2 0.079 P.105 16 0.630 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 6 0.236 3 0.118 2 0.079 P.105 16 0.630 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 6 0.236 3 0.118 2 0.079 P.105 8 0.315 4 0.157 2.5 0.098 4 0.157 2 0.079 1.5 0.059 7 0.276 3.5 0.138 5 0.197 2.5 0.098 1.5 0.059 3 0.118 1.5 0.059 1 0.039 2 0.079 1 0.039 20 0.787 10 0.394 6 0.236 10 0.394 5 0.197 3 0.118 8 0.315 4 0.157 2.5 0.098 P.105 20 0.787 10 0.394 6 0.236 10 0.394 5 0.197 3 0.118 8 0.315 4 0.157 2.5 0.098 P.105 40 1.575 20 0.787 13 0.512 20 0.787 10 0.394 7 0.276 18 0.709 9 0.354 6 0.236 P.105 32 1.260 16 0.630 10 0.394 16 0.630 8 0.315 5 0.197 18 0.709 9 0.354 6 0.236 P.106 32 1.260 16 0.630 10 0.394 16 0.630 8 0.315 5 0.197 10 0.394 5 0.197 3 0.118 P.106 19 0.749 9 0.354 6 0.236 9 0.354 4.5 0.177 2.5 0.098 8 0.315 4 0.157 2.5 0.098 P.106 18 0.709 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 7 0.276 3 0.118 2 0.079 P.106 46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 14 0.551 7 0.276 4 0.157 7 0.276 3.5 0.138 16 0.630 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 6 0.236 3 0.118 2 0.079 P.106 16 0.630 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 6 0.236 3 0.118 2 0.079 P.106 Selection Guide 46 1.811 23 0.906 15 0.591 24 0.945 7 0.276 P.106 Fibers P.106 Amplifiers - 3 0.118 12 0.472 - - 8 0.315 - 4 0.157 20 0.787 - 10 0.394 - 10 0.394 - 6 0.236 3 0.118 23 0.906 11 0.433 8 0.315 14 0.551 7 0.276 4 0.157 11 0.433 5.5 0.217 5 0.197 2.5 0.098 1.5 0.059 3 0.118 1.5 0.059 1 0.039 2 0.079 1 0.039 11 0.433 5 0.197 3 0.118 6 0.236 3 0.118 2 0.079 5 0.197 2.5 0.098 2 0.079 - 7 0.276 - - 3 0.118 - 1.5 0.059 P.105 P.105 P.106 P.107 P.107 - - - - - - - P.107 - - - - - - - - - P.107 - - - - - - 0.5 to 3.5 0.020 to 0.138 - - P.107 23 0.906 11 0.433 8 0.315 14 0.551 7 0.276 4 0.157 11 0.433 5.5 0.217 3 0.118 P.107 11 0.433 5 0.197 3 0.118 6 0.236 3 0.118 2 0.079 5 0.197 2.5 0.098 1.5 0.059 P.107 5 0.197 2.5 0.098 1.5 0.059 3 0.118 1.5 0.059 1 0.039 2 0.079 1 0.039 23 0.906 11 0.433 8 0.315 14 0.551 7 0.276 4 0.157 11 0.433 5.5 0.217 - - - - - - P.107 P.107 - - - P.108 - - - - - - 5 to 8 0.197 to 0.315 - - P.108 4 to 9 0.157 to 0.354 - - - - - 4 to 12 0.157 to 0.472 - - P.108 4 to 15 0.157 to 0.591 - - - - - 5 to 8 0.197 to 0.315 - - P.108 3 to 28 0.118 to 1.102 3 to 14 0.118 to 0.551 4 to 8.4 0.157 to 0.331 3 to 16 0.118 to 0.630 4 to 8 0.157 to 0.315 4.8 0.189 3 to 18 0.118 to 0.709 - - P.108 Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS P.107 - 3 0.118 PLC / TERMINALS P.106 - - LASER MARKERS FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 191 Digital Fiber Sensor FIBER OPTIONS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS FX-300 SERIES Lens (for thru-beam type fiber) Designation Model No. Description MICRO PHOTOELECTRIC SENSORS Sensing range for red LED type (mm) [Lens on both sides] (Note 3) AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS Expansion lens (Note 1) INDUCTIVE PROXIMITY SENSORS FX-LE1 PARTICULAR USE SENSORS FX-311 FX-301-F7/ FX-301-F 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 2,500 1,300 1,000 FT-R80 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 2,300 1,600 800 750 FT-W8 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 2,900 2,000 1,000 900 FT-P80 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 2,500 1,100 1,000 FT-P60 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 1,500 900 800 * Ambient temperature: -60 to +350 C -76 to +662 F (Note 5) For thru-beam type fiber Superexpansion lens (Note 1) Tremendously increases the sensing range with large diameter lenses. FX-LE2 FT-P81X 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 2,500 2,000 1,300 1,100 950 1,500 750 700 900 500 400 1,100 900 600 * Ambient temperature: -60 to +350 C -76 to +662 F (Note 5) Mode U-LG LONG STDF STD FAST S-D H-SP FT-B8 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-FM2 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-R80 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-W8 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-P80 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-P60 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-P81X 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) FT-H35-M2 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-H20W-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,500 1,600 (Note 2) FT-H20-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) FT-H13-FM2 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) Sensing range for red LED type (mm) [Lens on both sides] (Note 3) Beam axis is bent by 90. Side-view lens FX-SV1 Expansion lens for vacuum fiber (Note 1) Vacuum resistant side-view lens (Note 1) * Ambient temperature: -60 to +300 C -76 to +572 F (Note 5) Mode STD FAST S-D FT-B8 1,450 1,100 660 530 400 186 180 FT-FM2 1,800 1,200 810 600 440 210 210 Fiber Amplifiers FX-410 1,000 FT-T80 Fiber Fibers FX-300 1,300 Sensing range for red LED type (mm) [Lens on both sides] (Note 3) Selection Guide FX-100 2,500 FT-H20-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) MACHINE VISION SYSTEMS FX-500 1,000 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) FT-FM2 FA COMPONENTS UV CURING SYSTEMS H-SP 1,000 3,000 FT-H20W-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) STATIC CONTROL DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS S-D 2,000 FT-H35-M2 3,500 (Note 2) 3,500 (Note 2) MEASUREMENT SENSORS HUMAN MACHINE INTERFACES FAST Increases the sensing range by 5 times or more. WIRE-SAVING SYSTEMS PLC / TERMINALS STD 3,500 (Note 2) 3,500 (Note 2) SIMPLE WIRE-SAVING UNITS LASER MARKERS U-LG LONG STDF FT-B8 SENSOR OPTIONS ENDOSCOPE Mode 2,500 Fiber U-LG LONG STDF H-SP FT-T80 1,800 1,200 810 600 440 210 210 FT-W8 1,300 900 600 450 330 160 160 FT-P80 1,800 1,200 810 600 440 210 210 FT-P60 850 650 400 300 200 130 120 FT-P81X 1,800 1,200 810 600 440 200 200 FT-H35-M2 840 550 370 280 200 90 90 FT-H20W-M1 400 310 180 140 100 50 50 FT-H20-M1 840 550 370 280 200 90 90 FV-LE1 Sensing range increases Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4) by 4 times or more. Mode U-LG LONG STDF STD FAST S-D H-SP * Ambient temperature: Fiber -60 to +350 C FT-H30-M1V-S 1,600 1,200 650 450 300 150 200 -76 to +662 F (Note 5) FV-SV2 Beam axis is bent by Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4) 90. Mode U-LG LONG STDF STD FAST S-D H-SP * Ambient temperature: Fiber -60 to +300 C FT-H30-M1V-S 1,600 1,200 650 450 300 150 200 -76 to +572 F (Note 5) Notes: 1) B e careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have adjusted it sufficiently. 2) T he fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-P81X, FT-H20W-M1 and FT-H20-M1: 1,600 mm 62.992 in). 3) T he sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers. 4) T he fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in U-LG and LONG modes take into account the length of the FT-J8 atmospheric side fiber. 5) Refer to p.76~ for the ambient temperatures of fibers to be used in combination. Digital Fiber Sensor FX-300 SERIES 192 FIBER OPTIONS FIBER SENSORS Lens (for reflective type fiber) Designation Pinpoint spot lens LASER SENSORS Model No. Pinpoint spot of o0.5 mm o0.020 in. Enables detection of minute objects or small marks. * Distance to focal point: 6 1 mm 0.236 0.039 in * Applicable fibers: FD-WG4, FD-G4 * Ambient temperature: - 40 to +70 C - 40 to +158 F (Note 2) FX-MR1 The spot diameter is adjustable Sensing range for red LED type (Note 1) from o0.7 to o2 mm o0.028 to o0.079 in according to how Distance to focal point Screw-in depth much the fiber is screwed in. 7 mm 0.276 in o18.5 mm o0.728 in approx. * Applicable fibers: FD-WG4, FD-G4 12 mm 0.472 in o27 mm o1.063 in approx. * Ambient temperature: Spot - 40 to +70 C o43 mm o1.693 in approx. 14 mm 0.551 in diameter - 40 to +158 F (Note 2) * Accessory: MS-EX-3 (mounting bracket) Screw-in depth For reflective type fiber Zoom lens Finest spot lens FX-MR2 Distance to focal point FX-MR3 Distance to focal point Spot diameter Finest spot lens FX-MR6 Screw-in depth Zoom lens Side-view type FX-MR5 PHOTOELECTRIC SENSORS Description Distance to focal point Spot diameter Extremely fine spot of o0.3 mm o0.012 in approx. achieved. * Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 * Ambient temperature: - 40 to +70 C - 40 to +158 F (Note 2) Sensing range for red LED type (Note 1) Extremely fine spot of o0.1 mm o0.004 in approx. achieved. * Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 * Ambient temperature: -20 to +60 C - 4 to +140 F (Note 2) Sensing range for red LED type (Note 1) Distance to focal point Fiber Spot diameter o0.7 mm o0.028 in o1.2 mm o0.047 in o2.0 mm o0.079 in Spot diameter 7.5 0.5 mm 0.295 0.020 in o0.15 mm o0.006 in approx 7.5 0.5 mm 0.295 0.020 in o0.2 mm o0.008 in approx FD-EG1 7.5 0.5 mm 0.295 0.020 in o0.3 mm o0.012 in approx FD-WG4/G4/G6X/G6 7.5 0.5 mm 0.295 0.020 in o0.5 mm o0.020 in approx Spot diameter FD-EG3 7 0.5 mm 0.276 0.020 in o0.1 mm o0.004 in approx FD-EG2 7 0.5 mm 0.276 0.020 in o0.15 mm o0.006 in approx FD-EG1 7 0.5 mm 0.276 0.020 in o0.2 mm o0.008 in approx FD-WG4/G4/G6X/G6 7 0.5 mm 0.276 0.020 in o0.4 mm o0.016 in approx FX-MR2 is converted into a Sensing range for red LED type (Note 1) side-view type and can be Screw-in depth Distance to focal point mounted in a very small space. * Applicable fibers: 13 mm 0.512 in approx. 8 mm 0.315 in FD-WG4, FD-G4 15 mm 0.591 in approx. 10 mm 0.394 in * Ambient temperature: - 40 to +70 C 30 mm 1.181 in approx. 14 mm 0.551 in - 40 to +158 F (Note 2) Spot diameter o0.5 mm o0.020 in o0.8 mm o0.031 in o3.0 mm o0.118 in Notes: 1) The sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifier. 2) Refer p.76~ for the ambient temperatures of fibers to be used in combination. Others Designation Model No. Description FTP-500 (0.5 m 1.641 ft) For M4 Protective tube FTP-1500 (1.5 m 4.922 ft) thread (For thru-beam FTP-N500 (0.5 m 1.641 ft) For type fiber) FTP-N1000 (1 m 3.281 ft) M3 FTP-N1500 (1.5 m 4.922 ft) thread FT-42 FT-B8 FT-FM2 FT-FM2S FDP-500 (0.5 m 1.641 ft) For FDP-1000 (1 m 3.281 ft) M6 Protective tube FDP-1500 (1.5 m 4.922 ft) thread (For reflective FDP-N500 (0.5 m 1.641 ft) For type fiber) FDP-N1000 (1 m 3.281 ft) M4 FDP-N1500 (1.5 m 4.922 ft) thread Fiber bender FB-1 MS-AJ1-F Universal sensor mounting stand (Note 2) MS-AJ2-F Single core FX-AT15A holder Applicable fibers FTP-1000 (1 m 3.281 ft) FT-FM2S4 FT-H13-FM2 FT-P60 FT-P80 The protective FT-31 FT-P40 tube, made of FT-NFM2 FT-T80 noncorrosive FT-NFM2S FD-P40 stainless steel, FT-NFM2S4 FD-T40 protects the FD-61 FD-FM2S4 inner fiber FD-B8 FD-H13-FM2 cable from FD-FM2 FD-P80 any external FD-FM2S forces. FD-41 FD-T80 FD-NFM2 FD-NFM2S FD-NFM2S4 The fiber bender bends the sleeve part of the fiber head at the proper radius. (Note 1) Horizontal mounting type Mounting stand assembly for fiber Vertical mounting type (For M3,M4 or M6 threaded head fiber) The incident light intensity may vary when using a multi-core fiber or a thin type sharp bending fiber. This holder suppresses the variation in the incident light intensity. Brown. Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber. 2) Refer to the universal sensor mounting stand MS-AJ series pages for details. Protective tube Fiber bender * FTP- * FDP- * FB-1 Using the arm which enables adjustment in the horizontal direction, sensing can also be done from above an assembly line. Swivel: 360 rotation * MS-AJ1-F SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifiers FX-500 FX-100 FX-410 Height adjustment: 150 mm 5.906 in approx. 20 Mounting hole for M6 screw 20 Angle adjustment: 20 Swivel: 360 rotation Forward / back adjustment: 130 mm 5.118 in approx Single core holder * FX-AT15A Height adjustment: 150 mm 5.906 in approx. 360 PARTICULAR USE SENSORS FX-300 Forward / back adjustment: 130 mm 5.118 in approx * MS-AJ2-F INDUCTIVE PROXIMITY SENSORS Fibers Universal sensor mounting stand 360 PRESSURE / FLOW SENSORS SENSOR OPTIONS FD-EG3 Distance to focal point AREA SENSORS LIGHT CURTAINS FD-EG2 Fiber MICRO PHOTOELECTRIC SENSORS 20 20 Angle adjustment: 20 Mounting hole for M6 screw FX-311 FX-301-F7/ FX-301-F 193 Digital Fiber Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Type AREA SENSORS Model No. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS FX-300 SERIES Item FX-301 FX-301B FX-301G FX-301H FX-301-HS FX-305 FX-301BP FX-301GP FX-301HP FX-301P-HS FX-305P Power consumption Output PARTICULAR USE SENSORS SENSOR OPTIONS ENDOSCOPE Response time Sensitivity setting PLC / TERMINALS Digital display MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 Selectable either Light-ON or Dark-ON, with jog switch Incorporated 35 s or less (H-SP), 65 s or less [H-SP (Red LED type only)], 150 s or less (FAST), 150 s or less (FAST), 250 s or less [STD / S-D (Red LED type only)], 250 s or less (STD / S-D), 2 ms or less (LONG), 2 ms or less (LONG), selectable with jog switch selectable with jog switch Timer function Light emitting amount selection function Automatic interference prevention function Ambient temperature 65 s or less (H-SP), 150 s or less (FAST), 250 s or less (STD), 700 s or less (STDF), 2.5 ms or less (LONG), 4.5 ms or less (U-LG), selectable with jog switch Normal mode: 2-point teaching / Limit teaching / Full-auto teaching / Max. sensitivity teaching / Manual adjustment Window comparator mode: Teaching (1-point / 2-point / 3-point) / Manual adjustment 2-point teaching / Limit teaching / Manual adjustment / Full-auto teaching / Max. sensitivity teaching Orange LED (lights up when the output is ON) - Green LED (lights up under stable light received condition or stable dark condition) RUN: Green LED, TEACH * ADJ * L/D ON * TIMER * PRO: Yellow LED 4 digit red LED display Fine sensitivity adjustment function Incorporated Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. Timer period: Red LED type; 0.5 ms approx., 1 to 9999 ms (Blue LED, Green LED, Infrared LED type; approx. 0.5 to 500 ms) Incorporated (Red LED type only) (Note 3) FAST, STD, LONG: 4 level, H-SP: 3 level, S-D: 2 level Incorporated (Up to four sets of fiber heads can be mounted close together. However, H-SP mode is 2 fiber heads.) (Note 4) Incorporated with variable ON-delay / OFF-delay / ONE SHOT / ON-delay * OFF-delay / ON-delay * ONE SHOT timer, switchable either effective or ineffective. (Timer period: Output 1; 0.5 ms, 1 to 9999 ms, Output 2; 0.5 ms, 1 to 500 ms) Incorporated (Note 3) FAST, STD, LONG: 4 level H-SP, S-D: 2 level Incorporated (Note 3) FAST, STD, STDF, LONG, U-LG: 4 level H-SP: 3 level - Incorporated [Up to four sets of fiber heads can be mounted close together. (However, U-LG mode is 8 fiber heads, H-SP mode is 2 fiber heads.)] (Note 5) -10 to +55 C +14 to +131 F (If 4 to 7 units are connected in cascade: -10 to +50 C +14 to +122 F, if 8 to 16 units are connected in cascade: -10 to +45 C +14 to +113 F) (No dew condensation or icing allowed), Storage: -20 to +70 C - 4 to +158 F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 x at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 6) Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 6) Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Emitting element (modulated) 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Red LED Blue LED Green LED Infrared LED Red LED Red LED Peak emission wavelength 650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil 940 nm 0.037 mil 650 nm 0.026 mil Material FX-410 Connecting method FX-311 Cable length FX-301-F7/ FX-301-F PNP open-collector transistor 2 outputs PNP open-collector transistor * Maximum source current: 50 mA each (Note 2) * Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) * Applied voltage: 30 V DC or less (between output and +V) * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less [at 50 mA (Note 2)] * Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) source current.] MODE indicator Environmental resistance FA COMPONENTS NPN open-collector transistor NPN open-collector transistor 2 outputs * Maximum sink current:100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) * Maximum sink current: 50 mA each (Note 2) * Applied voltage: 30 V DC or less (between output and 0 V) * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) sink current.] * Residual voltage: 1.5 V or less [at 50 mA (Note 2)] Operation indicator Stability indicator ENERGY CONSUMPTION VISUALIZATION COMPONENTS Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode: 430 mW or less (Current consumption 18 mA or less at 24 V supply voltage) Short-circuit protection LASER MARKERS HUMAN MACHINE INTERFACES 12 to 24 V DC 10 % Ripple P-P 10 % or less Output operation WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES High-function type FX-301P Supply voltage SIMPLE WIRE-SAVING UNITS High-speed Green LED Infrared LED type PNP output PRESSURE / FLOW SENSORS MEASUREMENT SENSORS Blue LED NPN output LIGHT CURTAINS INDUCTIVE PROXIMITY SENSORS Standard type Red LED Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-301B/G/H: Acrylic) Connector (Note 7) Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable. Weight Accessory 650 nm 0.026 mil Net weight: 20 g approx., Gross weight: 25 g approx. FX-MB1 (amplifier protection seal): 1 set - FX-MB1 (amplifier protection seal): 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) 50 mA per output. 25 mA if five, or more, amplifiers are connected in cascade. 3) The light emitting amount can be zero (emission halt) in all modes. 4) When the power supply is switched on, the light emission timing is automatically set for interference prevention. 5)When the interference prevention function " " is set, the number of mountable fiber heads becomes double. Furthermore, take care that the response time also becomes double. 6) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. 7)The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below. Main cable (3-core) for FX-301(P)(-HS): CN-73-C1 (Cable length 1 m 3.281 ft), CN-73-C2 (Cable length 2 m 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 ft) Sub cable (1-core) for FX-301(P)(-HS): CN-71-C1 (Cable length 1 m 3.281 ft), CN-71-C2 (Cable length 2 m 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 ft) Main cable (4-core) for FX-305(P): CN-74-C1 (Cable length 1 m 3.281 ft), CN-74-C2 (Cable length 2 m 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 ft) Sub cable (2-core) for FX-305(P): CN-72-C1 (Cable length 1 m 3.281 ft), CN-72-C2 (Cable length 2 m 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 ft) Digital Fiber Sensor FX-300 SERIES I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS FX-301(-HS) NPN output type I/O circuit diagram Sensor circuit D 1 3 Tr Terminal No. (Brown) +V (Note 1) (Black) Output 2 Load + - Load Black 12 to 24 V DC 10 % + Users' circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers, or more, are connected together. Sensor circuit 1 ZD INDUCTIVE PROXIMITY SENSORS 1 +V 3 Output 2 0V PARTICULAR USE SENSORS Tr 3 D 2 + - (Black) Output + Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers, or more, are connected together. - Load Blue (Note) Terminal arrangement diagram Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor 1 +V 3 Output 2 0V D 1 Tr1 3 Tr2 ZD1 4 ZD2 2 Terminal No. Wiring diagram Color code of quick-connection cable Load (Black) Output Load (White) Output 2 50 mA max. (Note 2) + - Load Load + - White 50 mA max. (Note 2) Users' circuit 12 to 24 V DC 10 % Fibers 1 +V 3 Output 1 2 0V Amplifiers 4 Output 2 FX-500 PNP output type Terminal No. 4 (Brown) +V (Note 1) 50 mA max. (Note 2) D Internal circuit 2 (White) Output 2 Color code of quick-connection cable Brown (Note) ZD2 (Black) Output 1 50 mA max. (Note 2) Tr2 Wiring diagram Color code of quick-connection cable 3 Tr1 UV CURING SYSTEMS Selection Guide FX-305P 1 FA COMPONENTS MACHINE VISION SYSTEMS Terminal arrangement diagram Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor ZD1 ENERGY CONSUMPTION VISUALIZATION COMPONENTS Note: T he quick-connection sub cable does not have brown lead wire and blue lead wire. Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max., if five amplifiers, or more, are connected together. I/O circuit diagram ENDOSCOPE Blue (Note) (Blue) 0 V (Note 1) Internal circuit Color code of quick-connection cable Black 12 to 24 V DC 10 % STATIC CONTROL DEVICES HUMAN MACHINE INTERFACES Brown (Note) (Brown) +V (Note 1) MEASUREMENT SENSORS PLC / TERMINALS NPN output type I/O circuit diagram SIMPLE WIRE-SAVING UNITS LASER MARKERS FX-305 Sensor circuit 12 to 24 V DC 10 % Note: T he quick-connection sub cable does not have brown lead wire and blue lead wire. Users' circuit SENSOR OPTIONS WIRE-SAVING SYSTEMS Black 12 to 24 V DC 10 % Load (Blue) 0 V (Note 1) Internal circuit Color code of quick-connection cable Brown (Note) (Brown) +V (Note 1) 100 mA max. (Note 2) AREA SENSORS PRESSURE / FLOW SENSORS Wiring diagram Color code of quick-connection cable MICRO PHOTOELECTRIC SENSORS Terminal arrangement diagram PNP output type Terminal No. PHOTOELECTRIC SENSORS LIGHT CURTAINS FX-301P(-HS) I/O circuit diagram LASER SENSORS Note: T he quick-connection sub cable does not have brown lead wire and blue lead wire. Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor Sensor circuit 12 to 24 V DC 10 % - Blue (Note) (Blue) 0 V (Note 1) Internal circuit Color code of quick-connection cable Brown (Note) 100 mA max. (Note 2) ZD Wiring diagram Color code of quick-connection cable 194 Load Load + - (Blue) 0 V (Note 1) Users' circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max., if five amplifiers, or more, are connected together. Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor + White Load Load - 12 to 24 V DC 10 % Blue (Note) Note: T he quick-connection sub cable does not have brown lead wire and blue lead wire. Terminal arrangement diagram 1 +V 3 Output 1 2 0V FX-300 FX-410 FX-311 Black 12 to 24 V DC 10 % FX-100 4 Output 2 FX-301-F7/ FX-301-F SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS Thru-beam type Parallel deviation PHOTOELECTRIC SENSORS FT-A8 FT-WA8 MICRO PHOTOELECTRIC SENSORS Horizontal direction PARTICULAR USE SENSORS ENDOSCOPE LASER MARKERS 400 15.748 UV CURING SYSTEMS Selection Guide Fibers STDF STD H-SP 0 200 7.874 100 0 100 3.937 3.937 Down Up Center Operating point (mm in) FT-P81X Thru-beam type STD H-SP 500 19.685 0 800 31.496 200 7.874 Fiber head L Fiber head FT-W4 FT-WS4 Thru-beam type Fiber head L Fiber head 800 31.496 White non-glossy paper L Fiber U-LG head 600 23.662 STDF 400 15.748 200 7.874 Amplifiers Reflective type STD H-SP 0 100 3.937 FX-500 STD 0 400 15.748 100 0 100 200 3.937 3.937 7.874 Left Right Center Operating point (mm in) FD-B8 STDF H-SP U-LG Fiber head L Fiber head STD 100 3.937 H-SP 0 40 1.575 200 0 200 400 7.874 7.874 15.748 Left Right Center Operating point (mm in) Fiber head L Fiber head L Fiber head U-LG H-SP 0 400 15.748 STD 200 0 200 400 7.874 7.874 15.748 Left Right Center Operating point (mm in) FT-W8 FT-WS8 Thru-beam type U-LG 600 23.662 STDF Fiber head STDF 500 19.685 400 0 400 800 15.748 15.748 31.496 Left Right Center Operating point (mm in) 200 7.874 U-LG 500 19.685 Reflective type Sensing fields Setting distance L (mm in) MACHINE VISION SYSTEMS 8 mm 0.315 in approx. Fiber head 1,000 39.370 U-LG 200 7.874 HUMAN MACHINE INTERFACES FA COMPONENTS L 1,000 39.37 1,000 39.37 800 31.496 PLC / TERMINALS ENERGY CONSUMPTION VISUALIZATION COMPONENTS 1,000 39.37 STDF Setting distance L (mm in) STATIC CONTROL DEVICES H-SP 0 200 7.874 FT-NFM2 FT-NFM2S Thru-beam FT-NFM2S4 FT-SNFM2 type Fiber head 1,500 59.06 STDF 400 15.748 STD H-SP 200 7.874 0 200 7.874 20 0 20 40 0.787 0.787 1.575 Left Right Center Operating point (mm in) Fiber head L Fiber head 100 0 100 200 3.937 3.937 7.874 Left Right Center Operating point (mm in) Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.) FD-FM2 Reflective type 200 7.874 U-LG 400 15.748 STDF 200 7.874 White nonglossy paper L Fiber head STD STDF 100 3.937 0 20 0.787 50 0 50 100 1.969 1.969 3.937 Left Right Center Operating point (mm in) Reflective type White non-glossy paper U-LG L Fiber head 150 5.906 50 1.969 H-SP 0 100 3.937 50 0 50 100 1.969 1.969 3.937 Left Right Center Operating point (mm in) FD-G4 FD-G6X 200 7.874 Setting distance L (mm in) MEASUREMENT SENSORS STD 2,000 78.74 FT-FM2 FT-FM2S FT-FM2S4 Thru-beam type FT-SFM2 FT-T80 U-LG Setting distance L (mm in) WIRE-SAVING SYSTEMS L Fiber head 100 0 100 200 3.937 3.937 7.874 Left Right Center Operating point (mm in) Setting distance L (mm in) SIMPLE WIRE-SAVING UNITS 0 200 7.874 SENSOR OPTIONS Fiber head H-SP 1,000 39.37 STDF 3,000 118.11 STD 2,000 78.74 Thru-beam type 2,000 78.74 U-LG Setting distance L (mm in) INDUCTIVE PROXIMITY SENSORS STDF Setting distance L (mm in) PRESSURE / FLOW SENSORS 4,000 157.48 U-LG 3,000 118.11 FT-B8 Vertical direction Setting distance L (mm in) LIGHT CURTAINS Setting distance L (mm in) AREA SENSORS 4,000 157.48 The following sensing characteristics pertain to the FX-300 red LED type.Please contact our office for the sensing characteristics pertaining corresponding to types other than the red LED or to types not mentioned here. Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.) Thru-beam type Setting distance L (mm in) LASER SENSORS FX-300 SERIES Setting distance L (mm in) Digital Fiber Sensor Setting distance L (mm in) 195 White non-glossy paper L Fiber U-LG head 150 5.906 100 3.937 STD 50 1.969 H-SP STDF STD H-SP 40 1.575 10 0 10 20 0.394 0.394 0.787 Left Right Center Operating point (mm in) Reflective type 20 0 20 40 0.787 0.787 1.575 Left Right Center Operating point (mm in) FX-100 200 7.874 400 15.748 White non-glossy paper U-LG L Fiber head 150 5.906 STDF 100 3.937 50 1.969 STD H-SP 0 20 0.787 10 0 10 20 0.394 0.394 0.787 Left Right Center Operating point (mm in) White non-glossy paper L U-LG Fiber head 300 11.811 200 7.874 STDF 100 3.937 H-SP 0 100 3.937 Reflective type STD 50 0 50 100 1.969 1.969 3.937 Left Right Center Operating point (mm in) FD-W8 FD-WS8 FD-WT8 400 15.748 White non-glossy paper U-LG L Fiber head 300 11.811 200 7.874 100 3.937 0 40 1.575 Reflective type STDF STD H-SP 20 0 20 40 0.787 0.787 1.575 Left Right Center Operating point (mm in) FD-WG4 FD-WSG4 Reflective type White non-glossy paper L Fiber U-LG head 100 3.937 Setting distance L (mm in) FD-P81X Setting distance L (mm in) FX-311 FX-301-F7/ FX-301-F FD-NFM2 FD-NFM2S FD-NFM2S4 Reflective type FD-SNFM2 FD-T40 Setting distance L (mm in) FX-410 Setting distance L (mm in) FX-300 STDF STD 50 1.969 H-SP 10 0.394 5 0 5 10 0.197 0.197 0.394 Left Right Center Operating point (mm in) Digital Fiber Sensor PRECAUTIONS FOR PROPER USE Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * The digital fiber sensor FX-301(P) has been modified since its production in June 2004. The explanations below are about the modified product. Mounting 35 mm 1.378 in width DIN rail Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. Fiber installation * Insert the fiber into the amplifier after attaching the attachment. Refer to the "Instruction Manual" included with the fiber for details. ush the fiber lock lever down. P Slowly insert the fiber into the insertion slot until it stops. (Note 1) Push the fiber lock lever back up until it stops. Fiber lock lever Fiber Notes: 1) N ote that if the fiber is not fully inserted, the sensing distance will decrease. Also note that the flexible fiber may bend during insertion. 2) In case of coaxial reflective type fibers (FD-G4, FD-FM2, etc.), mount the central fiber (single-core) to the emitter part and the peripheral fiber (multi-core) to the receiver. Note that sensing precision will deteriorate when done in reverse. Connection * Make sure that the power supply is off while connecting or disconnecting the quick-connection cable. Connection method Holding the connector of the quick-connection cable, align its projection with the groove at the top portion of the amplifier connector. Insert the connector till a click is felt. Disconnection method Pressing the projection at the top of the quick-connection cable, pull out the connector. Groove Projection Quick-connection cable 196 FIBER SENSORS LASER SENSORS Projection Note: Take care that if the connector is pulled out without pressing the projection, the projection may break. Do not use a quick-connection cable whose projection has broken. Further, do not pull by holding the cable, as this can cause a cable-break. Cascading How to mount the amplifier F it the rear part of the mounting section of the amplifier on a 35 mm 1.378 in width DIN rail. P ress down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the 35 mm 1.378 in width DIN rail. How to remove the amplifier Push the amplifier forward. Lift up the front part of the amplifier to remove it. FX-300 SERIES * Make sure that the power supply is off while adding or removing the amplifiers. * Make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade. * In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail. * When the amplifiers move on the DIN rail depending on the attaching condition or the amplifiers are mounted close to each other in cascade, fit them between the optional end plates (MS-DIN-E) mounted at the two ends. * Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.) * When connecting more than two amplifiers in cascade, use the sub cable (CN-71-C / CN-72-C) as the quick-connection cable for the second amplifier onwards. * When connecting amplifiers not close to each other in parallel, be sure to mount the optional end plate (MS-DIN-E) at both sides of each amplifier or affix the communication window seal of the accessory amplifier protection seal (FX-MB1) to the communication windows. * The settings other than the interference prevention function cannot be transmitted between FX-301(P) FX-301B/G/H(P), FX-305(P). Therefore, in case both models of amplifiers are mounted in cascade, be sure to mount identical models together. However, the interference prevention function is not incorporated in the FX-301(P)-HS. Take care when the sensors are mounted in cascade. * If the FX-301(P) updated version unit or the FX-305(P) is mounted with the FX-301(P) previous version unit or the FX-301B/G/H(P) in cascade, place the FX-301(P) updated version units and the FX-305(P) units to the right side (seen from the connector side) of the previous version units. For details, refer to "Cautions on sensor connection in cascade". For a difference between the updated version unit and the previous version unit, refer to "A difference between the updated version unit and the previous version unit". * The communication function of this product and that of the FX-301(P)-F / F7 is different. If these models are mounted in cascade, affix the accessory fiber amplifier protection seal (FX-MB1) included in the FX-301(P) and FX-305(P) to the communication windows of the amplifiers. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 197 Digital Fiber Sensor PRECAUTIONS FOR PROPER USE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Cascading method Mount the amplifiers, one by one, on the 35 mm 1.378 in width DIN rail. Slide the amplifiers next to each other, and connect the quickconnection cables. Mount the optional end plates (MS-DIN-E) at both the ends to hold the amplifiers between their flat sides. Tighten the screws to fix the end plates. FX-500 FX-100 FX-300 FX-410 Sub cable (CN-71/72-C) (Optional) Display [PRO4]. Slide ong press the [Jog Switch] and L [MODE key] at the same time. (Note 3) Main cable (CN-73/74-C) (Optional) End plate (MS-DIN-E) (Optional) Group B's Communication Specification Group A's Communication Specification
Optical communications Optical communications are possible are impossible Group A Group B Group B Group A Group A FX-301(P): Previous version unit (Note 1), FX-301G(P)/B(P)/H(P), FX-41(P), LS-401(P) (Note 2) Group B FX-301(P): Updated version unit (Note 1), FX-305(P) Notes: 1) For the difference between the updated version unit and the previous version unit, refer to "A difference between the updated version unit and the previous version unit". 2) W hen LS-401(P) is connected with the digital fiber amplifier in cascade, be sure to locate LS-401(P) at the left-most position (when viewed from the connector side). * When the units of the group A and the group B are connected in cascade as
shown above, optical communications cannot be done. When the optical communications function is used, connect them as
shown above. If the units cannot be placed as
, the following measure 1 or 2 should be taken. 1 2 Optical Communication Stop Notes: 3) E very time the [Jog Switch] and the [MODE key] is simultaneously long pressed, the display changes in this sequence: " "" "" "" "" ". * When the units in the group A and the group B shown in the table below are connected in cascade, connect them in cascade as
shown below. FX-311 FX-301-F7/ FX-301-F Sub unit Cautions on sensor connection in cascade UV CURING SYSTEMS Amplifiers Main unit How to change the communication specification of Group B * Change the communication specification of Group B according to the following procedures. Make sure to set the communication specification to " (Group A communication specification)" or " (Optical Communication Stop)". W hen you release the [Jog Switch] and [MODE key], the communication specification will be set and "PRO4" will be displayed. Slide MACHINE VISION SYSTEMS Fibers Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. 35 mm 1.378 in width DIN rail Dismantling Loosen the screws of the end plates. Remove the end plates. Slide the amplifiers and remove them one by one. FA COMPONENTS Selection Guide FX-300 SERIES ffix the communication window seal of the accessory A fiber amplifier protection seal (FX-MB1) to the communication window of the FX-301(P) updated version unit or FX-305(P). If the measure 1 described above cannot be taken, change the optical communications spec. of the group B units. Notes: 4) When the communication specification is set to " (Group A communication specification)", make sure to tightly attach the products. Also make sure to take note of the following: * There are instances when the optical communication function cannot be used due to the usage environment, etc. * Do not perform batch channel loading or saving. Part description MODE indicator / L/D ON (Yellow) MODE indicator / TIMER (Yellow) Stability indicator (Green)(Note2) Operation indicator (Orange) (Note1) MODE indicator / RUN (Green) MODE indicator / PRO (Yellow) MODE indicator / TEACH (Yellow) MODE indicator / ADJ (Yellow) MODE key Jog switch Digital display (Red) Notes: 1) FX-305(P); Output 1 operation indicator (Orange) 2) FX-305(P); Output 2 operation indicator (Orange) Operation procedure * When the power supply is switched on, communication self-check is carried out and normal condition is displayed [MODE indicator / RUN (green)] lights up and the digital display shows the incident light intensity. * When the MODE key is pressed, the mode will change as shown in the following diagram. Power ON Communication self-check RUN Press MODE key Press MODE key [Teaching] TEACH (P.198) Press MODE key [Threshold value fine adjust] (P.199) ADJ PRO Press MODE key [PRO mode] (P.202) TIMER [Timer operation setting] (P.199) Press MODE key Press MODE key L/D [Output operation setting] (P.199) When Jog switch is pressed, the setting is confirmed. When MODE key is pressed for 2 sec., or more, the sensor returns to the `RUN' mode. Cancellation is possible by pressing MODE key during setting. Digital Fiber Sensor PRECAUTIONS FOR PROPER USE Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. For FX-305(P) In case of full auto-teaching The FX-305(P) is equipped with two independent outputs, but the items that can be set in output 1 and output 2 respectively are only the following. The items other than those are common. 1 Threshold value 2 Output operation 3 Timer operation and Timer period 4 Sensing mode Teaching * The threshold values can be set by 2-point teaching, limit teaching, full-auto teaching or window comparator mode (1-point, 2-point, 3-point teaching) [only for FX-305(P)], when the MODE indicator / TEACH (yellow) lights up. In case of 2-point teaching * This is the method of setting the threshold value by teaching two levels, corresponding to the object present and object absent conditions. Normally, setting is done by this method. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-305(P), select either Output 1 " " or Output 2 " " beforehand, press jog switch in the object present condition. If the teaching is accepted, the read incident light intensity blinks in the digital display. Thru-beam type Reflective type Mark Beam blocked condition Background MODE indicator / TEACH (yellow) blinks. Press jog switch in the object absent condition. Thru-beam type Reflective type Mark Beam incident condition FX-300 SERIES Background If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the midvalue between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. * In case stable sensing is possible: " " is displayed. * In case stable sensing is not possible: " " blinks. The threshold value is displayed. " " blinks in the digital display. (only FX-301B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. 2) In case a reflective-type fiber is used, maximum sensitivity will be set if the jog switch is pushed while in no work status in procedure and . * Full auto-teaching is used when it is desired to set the threshold value without stopping the assembly line, with the object in the moving condition. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-305(P), select either Output 1 " " or Output 2 " " beforehand, press the jog switch continuously for 0.5 sec. or more with the object moving on the assembly line. (The incident light intensity is displayed during sampling.) " " is displayed on the digital display. Release the jog switch when the object has passed. 198 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the midvalue between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. * In case stable sensing is possible: " " is displayed. * In case stable sensing is not possible: " " blinks. SIMPLE WIRE-SAVING UNITS The threshold value is displayed. ENDOSCOPE " " blinks in the digital display. (only FX-301B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) The threshold value's shift amount can be selected in PRO mode. Refer to the "PRO Mode Operation Guide" for more details pertaining to setting instructions. (Increments of 5 % between -45 and 45 % for setting possible. 0 % default.) 2) D o not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 199 FIBER SENSORS LASER SENSORS Digital Fiber Sensor FX-300 SERIES PRECAUTIONS FOR PROPER USE Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. MICRO PHOTOELECTRIC SENSORS In case of limit teaching * This is the method of setting the threshold value by teaching only the object absent condition (stable incident light condition). This is used for detection in the presence of a background body or for detection of small objects. AREA SENSORS Step PHOTOELECTRIC SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Description Thru-beam type Reflective type Background body Beam incident condition STATIC CONTROL DEVICES If jog switch is turned to the "+" side, " " scrolls (twice) the display from right to left (Note 1), and the threshold level is shifted to a value approx. 15 % higher (lower sensitivity) than that set at . (Note 2) This is used in case of reflective type fibers. If jog switch is turned to the "-" side, " " scrolls (twice) the display from left to right, and the threshold level is shifted to a value approx. 15 % lower (higher sensitivity) than that set at . (Note 2) This is used in case of thru-beam type fibers. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide High OFF Threshold value PLC / TERMINALS 100 % Low 0 ON 15 % Threshold value Incident light intensity with object absent 15 % ON OFF Threshold value Turn to "+" side Turn to "-" side After this, the judgment on whether the setting shift amount can be shifted or not is displayed. * I n case shifting is possible: " " blinks. * I n case shifting is not possible: " " blinks. Fibers Amplifiers The threshold value is displayed. FX-500 " " blinks in the digital display. (only FX-301B/G/H) FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Display - For FX-305(P), select either Output 1 " " or Output 2 " " beforehand, in case the threshold value is to be increased (sensitivity to be reduced), turn the jog switch to the "+" side to increase the threshold value slowly. If the jog switch is turned continuously to the "+" side, the threshold value increases rapidly. In case the threshold value is to be decreased (sensitivity to be increased), turn the jog switch to the "-" side to decrease the threshold value slowly. If the jog - switch is turned continuously to the "-" side, the threshold value decreases rapidly. When jog switch is pressed, the threshold value is confirmed. For FX-305(P), select either Output 1 " " or Output 2 " " beforehand, press jog switch in the object absent condition. If the teaching is accepted, the read incident light intensity blinks in the display. MODE indicator / TEACH (yellow) blinks. Turn jog switch to the "+" side or "-" side. LASER MARKERS Description Press MODE key to light up MODE indicator / ADJ (yellow). Display MEASUREMENT SENSORS ENDOSCOPE Step Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Threshold value fine adjustment The incident light intensity appears in the digital display and the setting is complete. Notes: 1) Scrolling display is not available in FX-301B/G/H. 2) The approx. 15 % amount of shift is the initial value. The amount of shift can be changed in the PRO mode from approx. 5 to 80 % (5 % step). Refer to the "PRO Mode Operation Guide" for more details pertaining to setting instructions. 3) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. Please download the instruction manual from our website for setting of threshold value when used in combination with liquid level sensing fiber FD-F8Y and with pipe-mountable liquid level sensing fiber FD-F4. For the wind comparator mode teaching in FX-305(P), refer to the separately prepared "PRO Mode Operation Guide". or - Output operation setting Step Description Press MODE key to light up MODE indicator / L/D ON (yellow). For FX-305(P), select either Output 1 " or Output 2 " " beforehand, if the jog switch is turn to - the "+" or "-" direction, the output operation setting will change. When jog switch is pressed, the threshold value is confirmed. Display Displays present setting " Light state Dark state Displays selected setting Timer operation setting * The setting for whether the timer is used or not can be done when MODE indicator / TIMER (yellow) lights up. For FX-301B/G/H, the timer type can be set in PRO mode. * Further, an OFF-delay (initial value) which is useful when the response of the connected device is slow, etc., an ON-delay which is useful to detect only objects taking a long time to travel, and ONE SHOT, which is useful when the input specifications of the connected device require a signal of a fixed width, are possible with the FX-301(-HS). FX-305(P) is also equipped with ON-delay * OFF-delay and ON-delay * ONE SHOT timers. Refer to the "PRO Mode Operation Guide" for the setting method of the OFF-delay, ON-delay and ONE SHOT timer intervals. Digital Fiber Sensor PRECAUTIONS FOR PROPER USE FX-300 SERIES Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. Wiring FIBER SENSORS LASER SENSORS Key-lock function * Make sure that the power supply is off while wiring. * Verify that the supply voltage variation is within the rating. * Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. * If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. * In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. * Take care that short circuit of the load wrong wiring may burn or damage the product. * Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. * Make sure to use an isolation transformer for the DC power supply. If an autotransformer (single winding transformer) is used, this product or the power supply may get damaged. * Make sure to use the optional quick-connection cable for the connection of the amplifier. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (5-8 unit expansion: 50 m 164.042 ft, 9-16 unit expansion: 20 m 65.617 ft) However, in order to reduce noise, make the wiring as short as possible. * Note that the residual voltage will increase when the cable is extended. 200 * If jog switch and MODE key are pressed for more than 2 sec. at the same time in `RUN' mode condition, the key operations are locked, and only the threshold value confirmation function or the adjust function (valid only when the adjust lock function is canceled) is valid. To cancel the lock function, press both the keys for more than 2 sec. once again. Note: 3 seconds or more for FX-301B/G/H(P). PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS Others * When the emission halt of the light emitting amount selection function is set from "OFF" to "ON", the output may be unstable. Do not use the output control for 0.5 sec. after starting emission. * Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. * Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc. , as it may affect the sensing performance. * Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in contact with corrosive gas. * Take care that the product does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. * This sensor cannot be used in an environment containing inflammable or explosive gases. * Never disassemble or modify the sensor. INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Function table for FX-300 series MACHINE VISION SYSTEMS Previous models Standard type FX-301(P) (Previous version unit) New models High-function type High-speed type FX-302(P) Standard type High-speed type High-function type FX-303(P) FX-301(P) (Updated version unit) FX-301(P)-HS FX-305(P) Four-chemical emitting element + APC circuit No No No Yes Yes Yes Four-chemical emitting element only Yes (Note) Yes Yes - - - Light emitting amount selection function No No No Yes Yes Yes Reduced intensity mode (S-D) Yes (Note) Yes No Yes Yes - 9,999 digit display UV CURING SYSTEMS Selection Guide Fibers Amplifiers No No No No No Yes Response time (Max. speed) 150 s 300 s 90 s 65 s 35 s 65 s FX-500 Interference prevention function (Effective no. of units) Incorporated (4) Incorporated (8) Not incorporated (0) Incorporated (4) Not incorporated (0) Incorporated (16) FX-100 Independent 2 outputs No No No No No Yes Alarm output function No No No No No Yes FX-300 Error output function No No No No No Yes Differential sensing No No No No No Yes Window comparator mode No Yes No No No Yes Peripheral units that can be combined Bank selection unit FX-CH(-P) Yes Yes No No No No External input unit FX-CH2(-P) No No No Yes No Yes Upper communication unit SC-GU1-485 No No No Yes No Yes Note: Except FX-301B/G/H. FX-410 FX-311 FX-301-F7/ FX-301-F 201 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Digital Fiber Sensor FX-300 SERIES PRECAUTIONS FOR PROPER USE Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. A difference between the updated version unit and the previous version unit for FX-301(P) (Red LED type) * The product has been modified as shown below since its production in June 2004. Changes in appearance Before change Top view After change Top view Name plate Display Uses special parts Side view Display changes Change in shape of jog switch SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS * "NAVI" is printed only on the both sides FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F * "NAVI" is printed only on a side 1. Checking blinking of sensitivity surplus The stable surplus display method after teaching has been changed. Previous version unit: Sensitivity surplus is indicated by the number of blinks of the stability indicator. After change Digital display only * Checking minor changes between previous and updated models can be done by checking whether the printing is on both sides or only one side. 1. Response times added An ultra high-speed mode (H-SP) has been added to the existing 4 response time modes [high-speed (FAST), reduced intensity (S-D), standard (STD) and long range (LONG)]. This is changed using " " in " " Before change 4 steps 2. Initial direct code value changed The factory default settings for the direct codes have been changed. Previous version unit 0000 Upgraded functions HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 1. Timer selection method Previous version unit: Timer type was changed using PRO1 mode. The "TIMER" setting in NAVI mode could only be turned on or off. After change: T he type of timer can be changed using the "TIMER" function in NAVI mode. 2. Checking threshold value in RUN mode The threshold values can be checked by turning the jog switch. Added to name plate Side view Changes in operation After change After change 0004 *T he default setting for the timer period is 10 ms, and the direct code for 10 ms is "4", so this has been changed. Internal circuit changes 1. Addition of an APC circuit A four-chemical emitting element which provides stable sensing over* long* periods* has been added, as well as an APC (Auto Power Control) circuit that improves stability during short periods. Cautions on sensor connection in cascade 5 steps 150 s (FAST) 65 s (added) (H-SP) 250 s (S-D) 150 s (FAST) 250 s (STD) 250 s (S-D) 2 ms (LONG) 250 s (STD) 2 ms (LONG) 2. Extension of timer period The setting range for the timer period was previously 500 ms, but this has been extended to a new range of 9,999 ms. 3. Light emitting amount selection function The light emitting amount can be changed to one of 4 levels (5 levels when emission halt is included). 4. Backup, copy lock and key lock functions added Backup: This selects whether or not threshold values set by teaching are written to (stored in) an EEPROM. Copy lock: This selects whether copy function and data bank function communication are possible or not. Key lock: This disables input using switches to prevent accidental changing of settings. When connecting the previous version unit (including FX-301B/G/H) and updated version unit to be used in a cascade, refer to "Cautions on sensor connection in cascade". Digital Fiber Sensor PRECAUTIONS FOR PROPER USE FX-300 SERIES Refer to General precautions, p.80~ for fiber precautions, and to the "PRO mode operation guide" on our website for details pertaining to operating instructions for the amplifier. 202 FIBER SENSORS Diagram of functions and settings LASER SENSORS The amplifier features and settings are generally classified into two main modes; the "NAVI mode" for items and settings that are frequently reconfigured, and the "PRO mode" that contains more detailed settings. PHOTOELECTRIC SENSORS RUN TEACH Run This indicates normal sensing operation. NAVI mode PRO Teaching The "threshold value" can be set by utilizing either "2-point teaching", "limit teaching", or "full-auto teaching". * When the FX-305(P) is in window comparator mode, the "threshold value" can be set by either "1-point teaching", "2-point teaching" or "3-point teaching". TIMER Pro Allows various detailed settings to be configured, such as optical communications, save / load and other settings. ADJ Allows fine adjustment of the "threshold value". Configures operation of the timer. AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS L/D Timer Adjust MICRO PHOTOELECTRIC SENSORS L-ON / D-ON Sets output operation either Light-ON, or Dark-ON. INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Response Time Change PRO1 Switches among response times. Configures timer operation. Light Emitting Amount Selection Changes the light emitting amount selection setting. [FX-301(P)(-HS), FX-305(P) only] Allows selection of different content to be indicated in the digital display. Sets hysteresis level. Shift Shifts the "threshold value" by a certain percentage increment in "limit teaching". Digital Display Setting PRO2 Hysteresis Timer Setting Stability Permits selection of stability indicator response levels for changes in the range for lighting up. [excluding the FX-305(P)] Digital Display Inversion Sets the viewing orientation of the digital display. ECO Mode Sets the digital display to turn ON / OFF. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS PRO3 PRO mode Data Bank Load Data Bank Save HUMAN MACHINE INTERFACES Loads configuration setting from the data bank. Saves configuration setting into the data bank. ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Copy PRO4 * The FX-301(P)-HS is not equipped with a PRO4 setting function. Using optical communications, configuration settings from the main unit are copied to connected sub units all at once. Backup Allows not to save the threshold value, by teaching via external input in EEPROM. [FX-301(P), FX-305(P) only] Remote Data Bank Load Remote Data Bank Save Using optical communication, configuration settings can be loaded from respective data banks all at once. Using optical communication, current configuration settings can be saved into respective data banks all at once. Communication Change To Permit / Not to Permit When using optical communication for carrying out copy / load / save operations all at once, this function allows optical communication to pass through the unit. Verifies whether optical communications have been properly established. (FX-301B/G/H only) Code PRO5 Available only in FX-305(P) Allows fine adjustment of the "threshold value" to be directly performed during RUN mode. Normal Mode PRO6 Sets a threshold value for ON / OFF operation. Reset All settings, except for data bank information, revert to factory settings. Interference Prevention Switching Switches the number of units for which interference prevention switching is enabled. * FX-305(P) only. The items that can be set are different for output 1 and output 2. Rising Differential Mode Window Comparator Mode Output 1 Judges if set two threshold values are within the required range or not. This can be selected in 1-point / 2-point / 3-point teaching. Sensing mode that cancels out slight changes in light intensity so that only sudden increases in incident light intensity are sensed. Output 2 Error Output Alarm Output Trailing Differential Mode Output when overcurrent occurs or when a communication error occurs from connected incompletely. Be used as alarm output when the threshold value for output 2 is linked to output 1 and the light amount drops. Sensing mode that cancels out slight changes in light intensity so that only sudden decreases in incident light intensity are sensed. UV CURING SYSTEMS Test Adjust Lock Allows basic configuration information to be set in a single step, by inputting a 4-digit code. MACHINE VISION SYSTEMS * The 0-ADJ setting function equipped on the FX-301 and FX-305(P) has been deleted since the production in May 2005. Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 203 FIBER SENSORS LASER SENSORS Digital Fiber Sensor DIMENSIONS (Unit: mm in) AREA SENSORS LIGHT CURTAINS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES MODE key Jog switch 3 0.118 10 0.394 64.5 2.539 Communication window Beamemitting part 7 0.276 Beamreceiving part 10.5 0.413 7 0.276 3 0.118 13.5 0.531 * Length L UV CURING SYSTEMS Selection Guide 3.95 0.156 Suitable for 35 mm 1.378 in width DIN rail 36.5 1.437 Main cable (Optional) Length L CN-73/74-C1 1,000 39.370 CN-73/74-C2 2,000 78.740 CN-73/74-C5 5,000 196.850 2.65 0.104 (Note 2) 50 1.969 o3 o0.118 cable 14 (0.551 ) 2.54 0.100 (Note 1) CN-71-CCN-72-C Sub cable (Optional) * Length L L Model No. FA COMPONENTS MACHINE VISION SYSTEMS (Note 3) Notes: 1) FX-305; Output 1 operation indicator (Orange) 2) FX-305; Output 2 operation indicator (Orange) 3) FX-301; 3-pin, FX-305; 4-pin LASER MARKERS ENERGY CONSUMPTION VISUALIZATION COMPONENTS 3.3 0.130 7 0.276 27.8 1.094 30.5 1.201 CN-73-CCN-74-C HUMAN MACHINE INTERFACES 0.7 0.028 Digital display (Red) ENDOSCOPE PLC / TERMINALS 12 0.472 Stability indicator (Green) (Note 2) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Amplifier 48.2 26.3 1.898 1.0352.5 0.098 8.3 Operation indicator (Orange) (Note 1) 0.327 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS The CAD data in the dimensions can be downloaded from our website. FX-301FX-305(P) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS FX-300 SERIES 2.9 (0.114 ) 10 0.394 6 0.236 2.54 0.100 CN-71/72-C1 1,000 39.370 CN-71/72-C2 2,000 78.740 CN-71/72-C5 5,000 196.850 7 0.276 10 0.394 13.6 0.535 3 0.118 (Note 2) 14 (0.551 ) 3 0.118 2.9 (0.114 ) 10 0.394 6 0.236 ( ) 12 10.5 (0.472 ) 0.413 2.54 0.100 2.65 0.104 7.2 0.283 50 1.969 o3 o0.118 cable 2.54 0.100 (Note 1) 0.2 0.008 Notes: 1) CN-74-C only 2) CN-73-C; 3-core Length L ( ) 12 10.5 (0.472 ) 0.413 L Model No. 0.2 0.008 Notes: 1) CN-72-C only 2) CN-71-C: 1-core 7 0.276 10 0.394 13.6 0.535 3 0.118 7.2 0.283 Fibers Amplifiers FX-500 FX-100 MS-DIN-2 Amplifier mounting bracket (Optional) 10 0.394 3.2 0.126 FX-410 FX-311 End plate (Optional) 2.75 0.108 3.2 0.126 8.5 0.335 FX-300 FX-301-F7/ FX-301-F 21.6 0.850 16 0.630 5.2 0.205 MS-DIN-E 0.4 0.016 o1.8 o0.071 7.5 0.295 4.2 0.165 5.2 0.205 35 1.378 2 0.079 2 0.079 2-o3.2 o0.126 holes Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) 5 0.197 15 0.591 60 2.362 3 0.118 5.6 M3 square nut 0.220 24.7 0.972 t1 t 0.039 27 1.063 M3 (length 18 mm 0.709 in) pan head screws 3 0.118 1.6 0.063 32 1.260 Material: Polycarbonate 4 0.157 Suitable for 35 mm 1.378 in width DIN rail 204 MEMO